정밀 축진동 측정에 사용되는 비접촉식 진동센서의 측정오차 (Measurement Errors of Non-contact Type Vibration Sensors Used for Precision Measurement of Shaft Vibration)

  • 전오성;김동혁;최병천
    • 소음진동
    • /
    • 제1권2호
    • /
    • pp.107-113
    • /
    • 1991
  • When non-contact type vibration probes are used for the precision measurement of shaft vibration, they can induce the measurement errors due to the shaft curvature since they have been calibrated for the flat plate. In this study the errors due to the shaft radius and the misalignment between the shaft and probe centerlines are analyzed, and an in-situ calibration tool, which can be conveniently used for calibration independent of the shaft curvature and material, is introduced.

  • PDF

Fundamental approach to development of plastic scintillator system for in situ groundwater beta monitoring

  • Lee, UkJae;Choi, Woo Nyun;Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1828-1834
    • /
    • 2019
  • The performance of a plastic scintillator for use in an in situ measurement system was analyzed using simulation and experimental methods. The experimental results of four major pure beta-emitting radionuclides, namely $^3H$, $^{14}C$, $^{32}P$, and $^{90}Sr/^{90}Y$, were compared with those obtained using a Monte Carlo N-particle (MCNP) code simulation. The MCNP simulation and experimental results demonstrated good agreement for $^{32}P$ and $^{90}Sr/^{90}Y$, with a relative difference of 1.95% and 0.43% between experimental and simulation efficiencies for $^{32}P$ and $^{90}Sr/^{90}Y$, respectively. However, owing to the short range of beta particles in water, the efficiency for $^{14}C$ was extremely low, and $^3H$ could not be detected. To directly measure the low-energy beta radionuclides considering their short range, a system where the source could flow directly to the scintillator was developed. The optimal thickness of the plastic scintillator was determined based on the suggested diameter. Results showed that the detection efficiency decreases with an increase in the depth of the water. The detection efficiency decreased drastically to approximately 10 cm, and the tendency was gradually constant.

스탠딩컬럼웰형(SCW) 지중열교환기의 열성능 측정에 관한 실험적 연구 (An Experimental Study on the Thermal Performance Measurement of Standing Column Well type Borehole Heat Exchanger)

  • 이상훈;최용석;안근묵
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.122.2-122.2
    • /
    • 2010
  • Knowledge of ground thermal properties is most important for the proper design of BHE(borehole heat exchanger) systems. The configure type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for in-situ determination of design data for Standing Column Well apply. The main purpose has been to determine in-situ values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a sub-circulation pump, a boiler, temperature sensors, flow meter and a data logger for recording the temperature and circulation fluid flow data. A constant heating power is injected into the SCW through the test rig and the resulting temperature change in the SCW is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective in-situ values of rock thermal conductivity and thermal resistance of SCW.

  • PDF

확산음장의 물리적 평가 - 확산체 설계이론과 방법론 - (Objective evaluation of scattered sound field: Theory and methodology of diffuser design)

  • 사토신이치;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.979-982
    • /
    • 2007
  • The effect of a scattering wall surfaces on sound diffusion can be assessed by determining the scattering and diffusion coefficients in the laboratory. However, the sound field in a concert hall including scattered reflections is different from the laboratory measurement condition. Therefore, there is a need for objective investigation of diffusion in real sound fields. In this paper, possible acoustical parameters of in-situ measurements are discussed.

  • PDF

한반도 3차원 지중응력의 분포와 이를 고려한 터널해석에 대한 연구 (Three Dimensional In-situ Stress Distribution in the Southern Korean Peninsula and Its Application in Tunnel Analysis)

  • 김동갑;박종관
    • 한국지반공학회논문집
    • /
    • 제18권2호
    • /
    • pp.65-74
    • /
    • 2002
  • 지중응력의 측정은 터널 및 지하구조물의 변위와 응력분포를 예측하는데 중요하다. 본 연구에서는 남부 한반도 지역의 지중응력 분포를 음력해방법과 수압파쇄법으로 측정된 새로운 380개의 자료를 통하여 재평가와 이를 고려한 삼차원 터널해석을 실시하였다. 지중응력분포의 결과에 의하면 변성암과 화강암지역의 수평응력분포는 퇴적암과 화산암의 분포에 비하여 불규칙한 경향을 보이고 있다. 화산암 지역에서는 수직응력에 대한 수평음력의 비(측압계수, K)는 150m 깊이 이상 심도에서 1보다 작다. 또한, 국내에서는 처음으로 측정된 지중응력에 대한 삼차원 방향과 크기를 동시에 그림으로 나타내었다. 삼차원 터널 해석에 의하면, 터널 주변의 변위에 대한 방향과 크기는 최대수평음력과 최소수평응력의 차이에 의하여 주로 영향을 받고 있다.

기계화 경작로의 포장공법 개발(지반공학) (Development of Pavement method for Farm Roads)

  • 송창섭;리신호;오무영;성찬용
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.431-437
    • /
    • 2000
  • The aim of the work described in this paper is to develope a pavement method for farm road. To this ends, a series of material test are conducted on in-situ soil which was mixed additives-coarse aggregate, polypropylene fiber, excellent soil compound etc. With the laboratory test results, in-situ pavement test was conducted during two years. The serious problem of the pavement is not appeared up to this time. And the measurement of field data is continued presently. The majority merits of this pavement method is low cost and using environmental materials.

  • PDF

INFRARED ABSORPTION MEASUREMENT DURING LOW-TEMPERATURE PECVD OF SILICON-OXIDE FILMS

  • Inoue, Yasushi;Sugimura, Hiroyuki;Takai, Osamu
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.297-302
    • /
    • 1999
  • In situ measurement of infrared absorption spectra has been performed during low-temperature plasma-enhanced chemical vapor depositiion of silicon-oxide films using tetramethoxysilane as a silicon source. Several absorption bands due to the reactant molecules are clearly observed before deposition. In the plasma, these bands completely disappear at any oxygen mixing ratio. This result shows that most of the tetramethoxysilane molecules are dissociated in the rf plasma, even C-H bonds. Existence of Si-H bonds in vapor phase and/or on the film surface during deposition has been found by infrared diagnostics. We observed both a decrease in Si-OH absorption and an increase in Si-O-Si after plasma off, which means the dehydration condensation reaction continues after deposition. The rate of this reaction is much slower than the deposition ratio of the films.

  • PDF

Dichromatic 투사광선에 따른 나노 미터 해상도의 점접촉 유막 두께 측정 연구 (Study on the Measurement Technology of Fluid Film Thickness with Nanometer Scale by Dichromatic Incident Light)

  • 공현상;장시열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.686-689
    • /
    • 2003
  • Many technologies are applied to the measurement of elastohydrodynamic lubrication (EHL) film thickness. In particular, optical in-situ interferometric method has many advantages in making the actual contact behaviors realized with the experimental apparatus. Careful selection of incident lights greatly enhances the fringe resolution up to nanometer scale by using image processing technology. In this work, it is found that dichromatic incident light can provide much finer resolution of EHL film thickness than monochromatic incident light, because it has much more variables of color components to be discriminated among the wavelengths of colors according the variations of EHL film thickness. Some simulated interferometric images are shown how the film thickness is resolutionized in nanometer scale

  • PDF

USING MODIS DATA TO ESTIMATE THE SURFACE HEAT FLUXES OVER TAIWAN'S CHIAYI PLAIN

  • Ho, Han-Chieh;Liou, Yuei-An;Wang, Chuan-Sheng
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.317-319
    • /
    • 2008
  • Traditionally, it is measured by using basin or empirical formula with meteorology data, while it does not represent the evaportransporation over a regional area. With the advent of improved remote sensing technology, it becomes feasible to assess the ET over a regional scale. Firstly, the IMAGINE ATCOR atmospheric module is used to preprocess for the MODIS imagery. Then MODIS satellite images which have been corrected by radiation and geometry in conjunction with the in-situ surface meteorological measurement are used to estimate the surface heat fluxes such as soil heat flux, sensible heat flux, and latent heat flux. In addition, the correlation coefficient between the derived latent heat and the in-situ measurement is found to be over 0.76. In the future, we will continue to monitor the surface heat fluxes of paddy rice field in Chiayi area.

  • PDF

역해석에 의한 지하구조체의 거동예측에 관한 연구 (A Study on the Behavior Prediction of Underground Structures by Back Analysis)

  • 장정범;김문겸
    • 터널과지하공간
    • /
    • 제8권2호
    • /
    • pp.139-145
    • /
    • 1998
  • The reliable estimation of the system parameters and the accurate prediction of the system behavior are important to design underground structures safely and economically. Especially, the elastic modulus and the in-situ stresses are very important parameters in predicting the behavior of the underground structure. Therefore, the back analysis using the field measurement data is developed to determine accurately the elastic modulus and the in-situ stresses of the underground structural system in this study. A back analysis using the combined finite and boundary element is developed. It can consider the far field boundary condition and is efficient in computation. In this study, a back analysis is performed to predict behaviors of underground structures for the real construction site. The comparison between the results of the back analysis with field measurement data and the obtained material properties from the field test shows good agreement for the real construction site.