• Title/Summary/Keyword: Impulse testing

Search Result 94, Processing Time 0.022 seconds

Solid Core Suspension Disc Insulators Preventing Puncture Caused by Steep Front Surge Voltage

  • Sangkasaad, Samruay
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.5
    • /
    • pp.165-170
    • /
    • 2003
  • This paper presents development of solid core suspension disc insulators (cap and cap suspension disc insulator) for replacing cap and pin suspension disc insulators in overhead transmission and distribution lines which expose to lightning discharges. By this means the punctured problem caused by steep front surge voltage created by lightning discharge on the lines can be solved. The solid core suspension insulator was designed and constructed based on the dimensions of conventional suspension disc insulators (cap and pin insulators). The insulators are made of alumina porcelain. The electrical and mechanical characteristics of the solid core suspension insulators were carried out. The puncture test was performed in the air by applying steep front impulse voltage with amplitude about 2.5 per unit of 50% flashover (CFO) of the insulator unit at negative standard lightning impulse $1.2/50\;\mu\textrm{s}$ with steepness up to $9200\;kV/\mu\textrm{s}$. The testing results show that solid core suspension disc insulators are not punctured eventhough the steepness of the steep front impulse voltage was increased up to $9200\;kV/\mu\textrm{s}$.

Affecting of Online Comments on Impulse Buying in E-Distribution

  • Tri Cuong, DAM
    • Journal of Distribution Science
    • /
    • v.21 no.3
    • /
    • pp.61-69
    • /
    • 2023
  • Purpose: This study's purpose is to conduct empirical research on online comments affect Vietnamese consumers' impulsive buying in e-distribution. This study also considers affecting of browsing toward the urge to buy, and the urge to buy toward impulse buying in e-distribution. Research design, data and methodology: This study used the non-probability method to assemble data from 273 customers' online buying experiences via a Google Forms online survey. By using SmartPLS, the data were examined for reliability, convergent validity, discriminant validity of the variables, and proposed hypothesis testing. Results: The empirical study discovered that internet comments with utilitarian and hedonistic values had a positive effect on browsing, the urge to buy, and impulse purchases in e-distribution. Additionally, the result revealed that browsing had a positive influence on the urge to purchase. Likewise, the findings also disclosed that the urge to buy had a favorable effect on impulse buying. Conclusions: This study offered a thorough conceptual model of internet feedback influencing browsing, urge to buy, and impulsive purchases in e-distribution. Also, to increase impulsive buying, this study will assist e-distribution managers in concentrating on developing innovative marketing strategies and action plans that take into consideration consumers' internet reviews, browsing, and urge to buy.

Effect of process conditions on crystal structure of Al PEO coating. II. Bipolar and electrolyte (알루미늄 PEO 코팅의 결정상에 미치는 공정 조건에 대한 연구 II. Bipolar 펄스와 전해액)

  • Kim, Bae-Yeon;Ham, Jae-Ho;Lee, Deuk Yong;Kim, Yong-Nam;Jeon, Min-Seok;Kim, Kiyoon;Choi, Ji-Won;Kim, Sung Youp;Kim, Kwang Youp
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.2
    • /
    • pp.65-69
    • /
    • 2014
  • Crystallographic phases of Plasma electrolytic oxidized Al alloy, A1100, A5052, A6061, A6063, A7075, were investigated. Two types of electrolyte $Na_2Si_2O_3$ and Na2P2O7 were also compared. Bipolar pulse, $2000{\mu}sec$ with $400{\mu}sec+420V$ impulse and $300{\mu}sec$ - impulse were applied for 20 min. ${\alpha}-alumina$, ${\gamma}-alumina$, ${\eta}-alumina$, $Al_{4.95}Si_{1.05}O_{9.52}$, and $(Al_{0.9}Cr_{0.1})_2O_3$ were mainly observed. Si, component of electrolyte, were moved into the PEO layer by bipolar pulse. Glassy phase was also observed at the surface of $Na_2Si_2O_3$ electrolyte treated PEO layer, and increased with the Mg content of Al alloy. It is concluded that at first glassy phase was formed by the micro plasma, and the high temperature of plasma turns glassy phase to several crystalline phases. And we could expect that many other crystalline phase could be formed by PEO process.

Study of the radial Turbine for Wave Energy Conversion (파력발전용 레이디얼터빈성능에 관한 연구)

  • Kim Tae-Ho;Kim Heuy-Dong;Setoguchi Toshiaki
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.549-552
    • /
    • 2002
  • The objective of this study is to clarify the detailed performances of the impulse type radial turbine and to present an optimum configuration of the turbine. The impulse type radial turbine has been manufactured and investigated experimentally under steady and sinusoidally oscillating flow conditions by model testing. Then, the starting characteristics under sinusoidally flow conditions have been evaluated by a numerical simulation using a quasi-steady analysis. As a result, the running and starting characteristics of the impulse type radial turbine for wave energy conversion have been clarified. Furthermore, the recommended configuration is presented, especially for setting angles of inner and outer guide vanes.

  • PDF

Life Analysis of High Pressure Hydraulic Hose Assemblies by Impulse Test (충격압력을 이용한 고압용 유압호스 조립체의 수명분석)

  • Lee Y.B.;Kim H.E.;Yoo Y.C.;Park J.H.;Ko J.M.;Kwak D.H.;Lee J.K.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.1
    • /
    • pp.10-16
    • /
    • 2004
  • The failures such as leakage and burst stemmed from the repetitive motions of bending and stretching of the assembly of hydraulic hose in construction machines, agriculture machines, vehicles, and industrial heavy machines can induce big troubles. Therefore, the hydraulic hose itself eventually requires an estimation of life to operate the hydraulic system safely. In this research, we have qualitatively selected the efficient test items by the analysis of the life and potential failures of hydraulic hose. We have used more than seven of hydraulic hoses simultaneously for the research. We have applied impulse pressure and half omega flexing motions to the accelerated life testing Test results have been expressed by employing weibull plot.

  • PDF

Life Prediction of High Pressure Hydraulic Hose Assemblies by the Impulse Test

  • KIM, Hyoung-Eui;LEE, Yong-Bum;Kwon, Young-Il
    • Corrosion Science and Technology
    • /
    • v.3 no.5
    • /
    • pp.209-215
    • /
    • 2004
  • Flexible hydraulic hose assembly that consists of hose and joints is used widely on various construction heavy equipments, agricultural machines, motor vehicles, and industrial heavy machines that require flexibility on hydraulic pipelines. It is classified by the maximum usage pressure which is determined by the winding layers of coiling steel wire and the inner diameter of the hoses. In this paper, we designed and performed an accelerated life test for assessing the reliability of a flexible hydraulic hose assembly. In the proposed accelerated life test, typical impulse pressure testing method is applied with the half omega flexing operation to simulate the practical flexing motion of the hose assembly.

Effects of lower extremity stability by kinesio taping method in elite speed skating athletes' one-leg jumping (엘리트 빙상 선수들의 외발점프 훈련 시 키네시오 테이핑요법이 하지관절 안정성에 미치는 영향)

  • Lee, Young-Seok;Kwak, Chang-Soo;Lee, Chung-Il;Kim, Tae-Gyu
    • Journal of Digital Convergence
    • /
    • v.13 no.8
    • /
    • pp.495-502
    • /
    • 2015
  • The purpose of this study was to investigating the effect of taping knee by testing the difference on kinetic variables of lower extremity when speed skating athletes jump on one leg. The results were as follows. The height of jumping after taping was higher, but the vertical height was not different according to taping. On take-off(TO), the horizontal and anterior-posterior maximum impulse force were decreased while the vertical maximum impact force was increased after taping. On landing(LD), the anterior-posterior maximum impulse force was decreased but the horizontal and vertical maximum impulse force were increased. TO, the impulse showed low after taping and the impulse dropped largely LD. The knee's moment of extension, eversion were reduced after tapping TO. LD, the flection moment of knee was decreased, but the inversion moment was increased after tapping. This study implies that the knee tapping helps injury prevention and performance enhancement, sports medicine convergence are needed.

Improved dynamic model of the impact hammer (개선된 충격해머의 동역학적 모델)

  • Lim, Byoung-Duk;Park, Jung-Hyun;Heo, Joon-Hyeok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.372.1-372
    • /
    • 2002
  • Although impact hammer is widely used as a convenient excitation tool in structural modal testing, little is known about the dynamic charateristics of its impulse mechanism. Transmission of the impulsive force to the structure depends on the dynamic properties of the impact hammer as well as the stiffness of the tip. An improved dynamic model of the impact hammer is proposed in this study with numerical simulations based on this model. (omitted)

  • PDF

A Study on the Step Response Characteristics in Shielded Resistor Divider for Switching Impulse Voltage (개폐 충격전압 측정용 쉴드 저항분압기의 직각파 특성에 관한 연구)

  • Kim, Ik-Su;Lee, Hyeong-Ho;Jo, Jeong-Su;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.777-784
    • /
    • 1999
  • Since the ultra-high voltage power apparatus are recommended to withstand switching surge generated from the electric power system, the switching impulse voltage is generally used to verify this requirement at the testing laboratories. Recently, the international standard(IEC 60060-2) related to the high voltage measurement techniques is revised requiring a traceability of measuring system for high voltage measurements. In this paper, a reference divider for switching impulse voltage is developed satisfying the revised. IEC standard and the possibility of applications has been investigated. Therefore, the characteristics of the high and low voltage side resistor and the shielding ring have been analyzed including the step response characteristics of the prototype divider. Throughout various efforts, it is confirmed that our measuring device has shown compatible characteristics as a reference divider.

  • PDF

Ultrasound Imaging Improvement using Higher Harmonics of Impluse Sound (고조파음원에 의한 초음파영상의 해상도 개선)

  • Chang, Jee-Won;Yang, Jeong-Won;Kim, Dong-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.4
    • /
    • pp.292-300
    • /
    • 1993
  • Acoustical imaging has made brilliant progress in the medical science field, and has also made much progress in the nondestructive testing and under water acoustics applications since doctor Dussik brother has studied about possibilities of making images of brain by recording variations in the intensity of ultrasonic beam from head in 1937. In this paper an acoustical image is reconstructed with the power spectra analysed by impulse ultrasound wave generated by electrodynamic transducer(EDT). The EDT generates the impulse ultrasound of 77KHz in center frequency and 120KHz in bandwidth at -20dB by 1200V exciter in this experiment. The impulse ultrasound has the dominant frequency components of 47KHz, 177KHz, 110KHz and 155KHz. The U shape object is adopted in making an acoustical image. The resulted spectral acoustical images are different from the optical view of the U shape object. However the image reconstructed from 110KHz spectrum is very similar to the original optical shape of the object. Even KHz level impulse sound of 70$\mu$sec pulse width is found to be useful in reconstructing acoustical imaging improvement.

  • PDF