• Title/Summary/Keyword: Improved operating characteristics

Search Result 330, Processing Time 0.031 seconds

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim, Kyeong-Hwa;Young, Myung-Joong
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.88-98
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet(PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF., resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

A Study on the Perception of Small Library Operations in Seoul (서울시 작은도서관 운영에 대한 인식조사 연구)

  • Han, Mun-Seong;Noh, Younghee;Lee, Keun Hwa;Choi, Man-Ho
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.28 no.2
    • /
    • pp.185-217
    • /
    • 2017
  • The purpose of this study was to investigate the status of the operation of small libraries in Seoul and to assess the perception of their importance and satisfaction. For this purpose, 861 small libraries in Seoul were surveyed on the overall operational satisfaction, operational improvement, and the importance of operation. As a result, it was discovered that there is a demand for increased operational support for small libraries, enhanced publicity, improved education and treatment of volunteers, improved quality of the book collection, and continuously improved space and facilities. Furthermore, the public and private libraries should be classified to reflect operational characteristics of the operating entity, rather than implementing the uniform budget support and guidance management.

A Design of the Improved Data Conversion Process for System Upgrade Project

  • Kim, Hee Wan
    • International journal of advanced smart convergence
    • /
    • v.10 no.2
    • /
    • pp.187-193
    • /
    • 2021
  • Data conversion refers to the process of extracting the data existing in the existing system, that is, the past data accumulated by the old information system or other methods and transferring it to the improved table of the new system. The person in charge of data conversion refers to the entire process of converting to the final destination table according to the rules designed/planned in advance. In most cases, data conversion design should be consider when the old system replace or the data of another existing system is converted and applied to a newly constructed information system. The goal of data conversion is to understand the current database system of operating environment, understand the characteristics of the DBMS in use, maintain the optimal database structure, and make the new system perform at its best. Data conversion methods are largely divide into a method using a tool and a conversion method using a program preparation. In this paper, we examine the advantages and disadvantages of the data conversion method, and try to derive the problems of the existing data conversion method. Based on this, an improved data conversion method for the system upgrade project was proposed, and verified through a questionnaire of an IT expert to prove its effectiveness

Coupled Field Circuit Analysis for Characteristic Comparison in Barrier Type Switched Reluctance Motor

  • Lee J.Y.;Lee G.H.;Hong J.P.;Hur J.;Kim Y.K.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.3
    • /
    • pp.267-271
    • /
    • 2005
  • This paper deals with two kinds of novel shape switched reluctance motors (SRM) with magnetic barriers in order to improve operating performances of prototype. The magnetic barriers make rotor poles more saturated, and consequently inductance profiles are distorted. The changed inductance affects input current shape and eventually torque characteristics. In order to analyze the complicated flux pattern of the SRM with magnetic barriers and its terminal characteristics simultaneously, coupled field circuit modeling method is used. The finite element method is used to model the nonlinear magnetic field, and coupled to the circuit model of the SRM overall system. After experimental results are presented to prove the accuracy of the method, the several analysis results are compared, and the improved rotor shape is presented.

A Study on the Combustion Characteristics of Ultra High Pressure Fuel Injection System in a Diesel Engine(I) (초고압 연료분사장치 디젤기관의 연소특성에 관한 연구(I))

  • Choi, D.S.;Rhee, Kyung-Tai
    • Journal of ILASS-Korea
    • /
    • v.4 no.1
    • /
    • pp.34-44
    • /
    • 1999
  • The purposes of this study were to evaluate engine performance and to analyze smoke emission characteristics for varied injection pressures and engine operating conditions of an electronically-controlled ultra high pressure fuel injection system(UHPFIS). It was discovered that the engine performance with the present UHPFIS was far better than what was initially expected. And the UHPFIS permitted engine operation at air/fuel ratios richer than 20 : 1 without increasing smoke emissions. It was discovered that the indicated mean effective pressure was increased, while the specific fuel consumption and the amount of soot were decreased, as the fuel rail pressures were improved atomization of the fuel spray. As the intake air temperature was increased from $38\sim205^{\circ}C$ in 38 degree increments, the indicated mean effective pressure was dropped while the specific fuel consumption was increased.

  • PDF

Plasma treatments of indium tin oxide(ITO) anodes in argon/oxygen to improve the performance and morphological property of organic light-emitting diodes(OLED) ($O_2$ : Ar 혼합가스 플라즈마로 ITO표면 처리한 OLED의 동작특성 향상과 표면개질에 관한 연구)

  • Seo, Yu-Suk;Moon, Dae-Gyu;Jo, Nam-Ihn
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04a
    • /
    • pp.67-68
    • /
    • 2008
  • A simple bi-layer structure of organic light emitting diode (OLED) was used to study the characteristics of anode preparation. Indium tin oxide (ITO) anode surface treatment of OLEDs was performed to get the optimum condition for the ITO anode. The ITO surface was treated by $O_2$ or $O_2$ / Ar mixed gas plasma with different processing time. The electrical characteristics of OLED were improved by plasma treatment. The operating voltage of OLED with $O_2$ or $O_2$/Ar mixed gas plasma treated anodes decreases from 8.2 to 3.4 V and 3.2V, respectively. The $O_2$ /Ar mixed gas plasma treatment results in better electrical property.

  • PDF

Experimental study on GM-type pulse tube refrigerator with neon as working fluid (네온을 작동유체로 하는 GM형 맥동관 냉동기의 실험적 연구)

  • Kim, Hyo-Bong;Park, Jong-Ho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.3
    • /
    • pp.31-35
    • /
    • 2011
  • This paper describes experimental study on GM-type pulse tube refrigerator with neon as a working fluid instead of helium. Neon gas has similar compression characteristics with helium gas because it is a monoatoimc gas. In experiments, a cooling performance test was performed with same compressor and pulse tube refrigerator for neon and helium as working gas. From experimental results, a PTR with neon show the improved cooling performance than a PTR with helium. Cooling performance and operating characteristics of a PTR were discussed and compared for two different working gas.

Embodiment of Low Operating Voltage in Positive Column AC-PDPs

  • Kim, Hyun;Tae, Heung-Sik;Chien, Sung-Il
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.95-98
    • /
    • 2003
  • The positive column discharge characteristics in the long gap (440 ${\mu}m$) are investigated based on the voltage distribution among three electrodes. In particular, the effects of the amplitude and width of the short pulse applied to the address electrode on the positive column discharge characteristics are examined intensively. By proper controlling of the amplitude and width of the address short pulse, it is found that the positive column discharge in the long gap is well constructed. As a result, under the stable static voltage margin condition, the firing and sustaining voltages are as low as those of conventional short gap(60 ${\mu}m$) discharge($V _f=220V$, $V_s=150V$) and the color purity is improved. Moreover, the luminous efficiency increases up to 60% in comparison with the conventional case.

  • PDF

Experimental Study on the Mean Flow Characteristics of Forward-Curved Centrifugal Fans

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1728-1738
    • /
    • 2001
  • Measurements have been made in an automotive HVAC b1ower for two different centrifugal fans. This work is directed at improving the performance of a conventional forward-curved centrifugal fan for a given small blower casing. Mean velocities and pressure have been measured using a miniature five-hole probe and a pressure scanning unit connected to an online data acquisition system. First, we obtained the fan performance versus flow rates showing a significant attenuation of unstable nature achieved with the new fan rotor in the surging operation range. Second, aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage for different fan operating conditions. The measurements stowed that performance coefficients are strongly influenced by flow characteristics at the throat region. The main flow features ware common in both fans, but improved performance is achieved with tole new fan rotor, particularly in lower flow rate legions. Based on the measured results, design improvements were carried out in an acceptable operation range, which gave considerable insight into what features of flow behavior ware most important.

  • PDF

Radiation Characteristics of a Dual Mode Inductor Loaded Patch Antenna (이중 모드 Inductor Loaded 패치 안테나의 방사 특성)

  • Kwak, Eun-Hyuk;Yoon, Young-Min;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.7
    • /
    • pp.28-34
    • /
    • 2011
  • Radiation characteristics of a dual-mode inductor loaded patch antenna using zeroth order resonance and half wavelength resonance are investigated. The isolation between two radiation patterns from the two different modes is improved by increasing the forward radiation and decreasing the horizontal radiation of half wavelength resonance mode. The frequency difference between the two resonant frequencies increases as the dielectric constant of the antenna substrate decreases and the operating frequency increases.