• Title/Summary/Keyword: Impression taking method

Search Result 37, Processing Time 0.026 seconds

Comparison of the accuracy of implant digital impression coping (임플란트 디지털 인상용 코핑의 정확성 비교)

  • Ahn, Gyo-Zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.29-40
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the accuracy of impression taking method using the encoded healing abutment, scan body and pick-up impression coping with different implant angulations. Materials and Methods: Master model was fabricated by 3D printer and three implants were placed into the model with 0°, 10° and 20° mesial angulation. The abutments were secured to each implants and master model was scanned to make a reference model. Group P model was fabricated using pick-up impression copings and model was scanned after securing the abutments. Encoded healing abutment (Group E) and scan body (Group S) were secured on the master model and digital impression was taken using intraoral scanner 15 times each. Each STL files of test groups were superimposed with reference model using best fit alignment and root mean square (RMS) value was analyzed. Results: The RMS values were lowest in Group P, followed by Group S and Group E. Group P showed significant difference with Group S and E (P < 0.05) while there was no significant difference between Group S and E. Correlation between implant angulation and RMS value was significant in Group E (P < 0.05). Conclusion: The pick-up impression coping method showed higher accuracy and there was no significant difference in accuracy between the healing abutment and the scan body. The clinical use of the encoded healing abutment is possible, but it should be used with caution in the case of angulated implant.

Implant prosthesis using intraoral scanner: Case Report (구강스캐너를 이용한 임플란트 보철물 제작 증례)

  • Kang, Byeong-Gil;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.256-261
    • /
    • 2015
  • Accuracy is the most important thing in implant prosthesis, for this reason it is essential procedure to check the accuracy of impression taking. However, impression material has its own error and the error occurs in model-making procedure. As an alternative way to this, using intraoral scanner can be suggested and many studies were issued reporting that there's no statistically significant difference in accuracy between intraoral scanner and conventional impression. Therefore, the purpose of this study is to report the process of making of implant prosthesis using intraoral scanner, which is more convenient, fast, accurate compared with conventional method.

Digital impression taking for full-arch implant restoration to a patient with microstomia (디지털 인상채득을 이용한 소구증을 가진 환자의 전악 임플란트 수복)

  • Shim, Ji Suk;Ryu, Jae Jun
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.616-621
    • /
    • 2018
  • This clinical case highlights the failure of long length implants, and the prosthodontic procedures necessary to rehabilitate the maxillary dentition of a patient with microstomia. The integrated digital technology of intra-oral scanning, computer-aided design, and three-dimensional printing can provide an alternative method to make conventional impressions for patients with microstomia who cannot insert the appropriate tray in their mouths.

  • PDF

STUDY ON DENTINAL TUBULES SEALING EFFECTS OF DENTIN BONDING AGENTS (DENTIN BONDING AGENTS들의 상아세관 밀봉 효과에 관한 연구)

  • Kown, O-Teak;Park, Dong-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.483-496
    • /
    • 1993
  • Dentin hypersensitivity medicaments such as Gluma, Scotchbond 2, All-Bond 2, which are resin adhesives, were used to compare the sealing effects of dentinal tubule under mechanical stress. Topical application of above medicaments on the dentin surfaces of extracted teeth followed by artificial tooth brushing for 6 weeks was performed for the comparison. The following conclusions on the degree of dentinal tubule exposure versus time by were reached by using polyvinyl siloxane impression material for taking the impression, epoxy resin for the duplication and SEM for observing the surface. 1. SEM was used to compare the accuracy of the duplicated surface, but no differences were found when teeth samples and the duplicated surfaces were observed. 2. After comparing the degree of dentinal tubules exposure with varnish applied contrast group, resin adhesive materials showed much less exposure as time went by. 3. The results indicated that AU-Bond 2 adhesive, under mechanical stress, showed lesser exposure of dentinal tubules comparing with Gluma and Scotchbond 2 adhesives After the results were put together, it was demonstrated that resin replica method is an useful way to evaluate the treatment effects of the dentinal tubule hypersensitivity medicaments. Also, it was noticed that under mechanical stress, All-Bond 2, classified as fourth generation, illustrated the best dentinal tubules sealing effects.

  • PDF

Manufacturing of metal-framework for maxillary removable partial dentures using milling wax-blocks (Wax-block milling을 이용한 상악 가철성 국소의치 금속구조물 제작 증례)

  • Seo, A-Ra;Kwon, Soon-Suk
    • Journal of Technologic Dentistry
    • /
    • v.44 no.1
    • /
    • pp.24-30
    • /
    • 2022
  • This research introduces the manufacturing process of the metal-framework of one of the maxillary partial dentures, the "obturator", using milling wax-blocks, for patients with palate loss due to oral cancer. It explains the protocol of taking the patient's oral impression, preparation of a working cast, scanning, designing using a computer-aided design program, investing the milling wax-blocks, and completing the obturator. This method does not follow the traditional wax and agar process thereby reducing the errors arising during the manufacturing process and decreasing the time, material, and labor required. Moreover, the retention, stability, and compatibility of the metal framework were observed to be high in both the working cast and oral cavity.

Retrospective study of implant stability according to the implant length, diameter and position (임플란트 길이, 직경 및 식립 위치에 따른 임플란트 안정성에 관한 후향적 연구)

  • Kim, Ji-Hye;Jeon, Jin-Yong;Heo, Yu-Ri;Son, Mee-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.269-275
    • /
    • 2013
  • Purpose: The aim of this retrospective study was to evaluate the influence of implant diameter, length and placement to implant stability. Materials and methods: Total 90 implants (US II plus$^{TM}$, Osstem co, Busan, Korea) of 72 patients were determined as experimental samples. The factors of diameters(${\phi}$ 4 mm, ${\phi}$ 5 mm), lengths (10 mm, 11.5 mm, 13 mm), and implant placement (maxilla, mandible) were analyzed. The stability of the implants was measured by resonance frequency analysis (RFA) at the time of implant placement and impression taking. The difference of ISQ values according to patient's gender was evaluated by Independent t-test. ISQ values were compared between implant diameter, length and placement using one-way ANOVA and Tukey HSD test (${\alpha}=.05$). To compare ISQ values between at the time of surgery and impression taking, paired t-tests were used (${\alpha}=.05$). Results: The change of implant length did not show significant different on the ISQ value (P>.05). However, 5 mm diameter implants had higher ISQ values than 4 mm diameter implants (P<.05). Implants placed on the mandible showed significantly higher ISQ values than on the maxilla (P<.05). Conclusion: In order to increase implant stability, it is better to select the wider implant, and implants placed on mandible are possible to get higher stability than maxilla. ISQ values at impression taking showed higher implant stability than ISQ values at implant placement, it means that RFA is clinically effective method to evaluate the change of implant stability through the osseointegration. The consideration of the factors which may affect to the implant stability will help to determine the time of load applying and increase the implant success rate.

DESIGN & DELIVERY OF SPACE MAINTAINERS WHEN PREMATURE EXTRACTION OF PRIMARY MOLAR UNDER GENERAL ANESTHESIA : A CASE REPORT (전신마취하에서 유치 조기발거시 간격유지장치의 설계 및 장착에 대한 증례보고)

  • Kang, Dug-Il;Jung, Moon-Young;Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.3
    • /
    • pp.704-709
    • /
    • 1997
  • Space maintainers needs following extraction of primary molars, due to severe dental caries under general anesthesia. Delivery of conventional space maintainers has three of the disadvantages of the method, there being a impression taking and time consuming due to laboratory procedure, and delivery problem due to relaxed tongue. For this problem improved, modified space maintainer is prefabricated before procedure, and adjust, delivery in operation room, favorable results were obtained. The following results were obtained. 1. Delivery time is very reduced than conventional space maintainers. 2. After space maintainer delivery, follow check-up, without impingement of soft tissue, distortion of wire. After space maintainer delivery, continuous research is required so that space maintainer delivery is applied to usual dental treatment, and it is necessary of long term research.

  • PDF

Complete denture fabricated by Jiro Abe's method for edentulous patient with severe alveolar ridge resorption: a case report (심한 치조제 흡수를 보이는 무치악 환자에서 Jiro Abe법에 의한 완전틀니 제작 증례)

  • Jun, Daejeon;Yang, Dong-Hun;Vang, Mongsook;Yang, Hongso;Park, Sangwon;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.338-345
    • /
    • 2014
  • Fabrication of complete denture by Jiro Abe's method was introduced that enhance the retention and stability of denture by sealing around the denture border with mucous membrane to make negative pressure at the inner surface of denture base when swallowing or occlusion. In this case, taking impression and fabricating complete denture by the Jiro Abe's method for an edentulous patient with severe mandibular alveolar bone resorption allowed us to obtain clinically enhance stability of denture and improve satisfaction of patient.

Complete denture rehabilitation of fully edentulous patient with severe bone resorption and class II jaw relation using piezography (심한 골 흡수와 2급 악간관계를 보이는 완전 무치악 환자의 Piezography를 이용한 총의치 수복)

  • Kwon, Wooil;Song, Young-Gyun;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.445-450
    • /
    • 2016
  • Piezography, prosthetic space recorded by pronunciation, can be used as a reference for arrangement of artificial teeth and polishing surface of a denture. In this case, a 67 year old female patient was presented for new dentures. Old dentures had class II relationship and poor retention. For fabrication of stable dentures, using piezography and lingualized occlusion was planned. After taking impressions with conventional method, conventional denture bases with wax rim were fabricated. Then, additional mandibular denture base was fabricated for piezography. With fast setting silicon impression material, piezography was recorded by using six pronunciations, 'si', 'so', 'me', 'te', 'de', and 'mu'. According to the piezographic space, mandibular artificial teeth were arranged and modified for lingualized occlusion. As a result, the patient was satisfied with new dentures functionally and esthetically.

Maxillary complete denture fabrication cases with posterior palatal seal considering palatal form and tissue displacement (구개 형태 및 조직 변위를 고려하여 후방 구개 폐쇄를 형성한 상악 총의치 제작 증례)

  • Kim, Seon-A;Son, Mee-Kyung;Heo, Yu-Ri
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.152-159
    • /
    • 2022
  • The role of the posterior palatal seal is important in retention of the maxillary complete denture. After taking the final impression, additional retention can be given to the maxillary denture through a mechanical method of forming a groove on master cast, but this is often overlooked in the clinical process. As a result, the posterior palatal seal is formed in a uniform way by the technician without considering the individual characteristics of the patient. Until now, various types of posterior palatal seal have been introduced by many people. This case report describes the process of manufacturing the maxillary complete denture by determining the position and form of an appropriate posterior palatal seal after considering the patient's anatomical palatal form and tissue displacement during function.