Impact of lattice versus solid structure of 3D-printed multiroot dental implants using Ti-6Al-4V: a preclinical pilot study

  • Lee, Jungwon;Li, Ling;Song, Hyun-Young;Son, Min-Jung;Lee, Yong-Moo;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • 제52권4호
    • /
    • pp.338-350
    • /
    • 2022
  • Purpose: Various studies have investigated 3-dimensional (3D)-printed implants using Ti6Al-4V powder; however, multi-root 3D-printed implants have not been fully investigated. The purpose of this study was to explore the stability of multirooted 3D-printed implants with lattice and solid structures. The secondary outcomes were comparisons between the 2 types of 3D-printed implants in micro-computed tomographic and histological analyses. Methods: Lattice- and solid-type 3D-printed implants for the left and right mandibular third premolars in beagle dogs were fabricated. Four implants in each group were placed immediately following tooth extraction. Implant stability measurement and periapical X-rays were performed every 2 weeks for 12 weeks. Peri-implant bone volume/tissue volume (BV/TV) and bone mineral density (BMD) were measured by micro-computed tomography. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were measured in histomorphometric analyses. Results: All 4 lattice-type 3D-printed implants survived. Three solid-type 3D-printed implants were removed before the planned sacrifice date due to implant mobility. A slight, gradual increase in implant stability values from implant surgery to 4 weeks after surgery was observed in the lattice-type 3D-printed implants. The marginal bone change of the surviving solid-type 3D-printed implant was approximately 5 mm, whereas the value was approximately 2 mm in the lattice-type 3D-printed implants. BV/TV and BMD in the lattice type 3D-printed implants were similar to those in the surviving solid-type implant. However, BIC and BAFO were lower in the surviving solid-type 3D-printed implant than in the lattice-type 3D-printed implants. Conclusions: Within the limits of this preclinical study, 3D-printed implants of double-rooted teeth showed high primary stability. However, 3D-printed implants with interlocking structures such as lattices might provide high secondary stability and successful osseointegration.

치과임플랜트 매식후 조기기능이 임플랜트 주위골조직에 미치는 영향에 관한 연구 (A STUDY ON THE EFFECTS OF EARLY LOADING ON THE SURROUNDING BONE TISSUE OF THE DENTAL IMPLANTS)

  • 박희운;양재호;이선형
    • 대한치과보철학회지
    • /
    • 제31권1호
    • /
    • pp.101-127
    • /
    • 1993
  • The purpose of this study was to observe the effects of early loading on the surrounding bone tissue of the implants. 12 ITI HS implants (8 mm) were inserted on the mandible at 3 mongrel dogs. The implants were divided into two groups; the functional group was functioned with crown, and nonfunctional group was functioned without crown. After 3 and 5 months animals were sacrificed and specimens were examined using radiography, light microscopy, scanning electron microscopy. The following results were obtained. 1. On light microscopic and scanning electron microscopic examination, the difference in the amounts of bone attachment between 3 months loaded and unloaded implants were a little. Sometimes more bone attachment were observed in loaded implants. 2. Many osteoids surrounded the fibrous connective tissues indicating of bone remodeling were observed along the outer surface of the implants. 3. On clinical, radiographic, microscopic examination, epithelial downgrowths were not observed and bone attachments to the outer surface of the implants were observed in 3 months loaded and unloaded implants with good oral hygiene. 4. Epithelial downgrowths and crater-like bone resorptions were observed on 5 months loaded and unloaded implants with poor oral hygiene. 5. Many inflammatory cells in the epithelial tissue were packed in the hollow on 5 months loaded implants.

  • PDF

Cumulative survival rate of Astra Tech implants: a retrospective analysis

  • Kim, Jung-Soo;Sohn, Joo-Yeon;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Lee, Jae-Hoon;Shim, June-Sung;Lee, Keun-Woo;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제41권2호
    • /
    • pp.86-91
    • /
    • 2011
  • Purpose: The aim of this study was to analyze the short-term predictability and reliability of Astra Tech implants according to the demographical distribution of patients and condition of implant sites and location of implants. Methods: Among patients treated with Astra Tech implant (Astra Tech AB) in the Department of Periodontology at the Dental Hospital of Yonsei University of College of Dentisry and K Dental Clinic from May 2004 to March 2009, 195 implants in 98 patients which had been restored more than 6 months ago were reviewed in this study. Following data were reviewed from patient charts and implants success rate was examined: 1) patient type and implant location, 2) bone status at the implant site, 3) diameter and length of the placed implants, 4) presence or absence of bone augmentation and types of the augmentation. Results: The results from this study are as follows: 1) most implants were placed in the molar area, especially 1st molar area of maxilla, 2) most implants were placed at $D_2$ and $D_3$ bone type, 3) most implants were placed in areas of B and C bone quantity, 4) autogenous and alloplastic bone graft and artificial membrane were used for placement of 74 implants. Conclusions: Short-term survival rate of Astra Tech implants was 100%.

The feasibility of immediately loading dental implants in edentulous jaws

  • Henningsen, Anders;Smeets, Ralf;Wahidi, Aria;Kluwe, Lan;Kornmann, Frank;Heiland, Max;Gerlach, Till
    • Journal of Periodontal and Implant Science
    • /
    • 제46권4호
    • /
    • pp.234-243
    • /
    • 2016
  • Purpose: Immediate loading of dental implants has been proved to be feasible in partially edentulous jaws. The purpose of this retrospective investigation was to assess the feasibility of immediately loading dental implants in fully edentulous jaws. Methods: A total of 24 patients aged between 53 and 89 years received a total of 154 implants in their edentulous maxillae or mandibles. Among the implants, 45 were set in fresh extracted sockets and 109 in consolidated alveolar bones. The implants were provisionally managed with chair-side made provisional resin bridges and exposed to immediate loading. Implants were followed up for 1-8 years, including radiographic imaging. Marginal bone levels were evaluated based on radiographic imaging. Results: A total of 148 out of the 154 implants survived over the follow-up period of 1 to 8 years, giving a survival rate of 96%. The time or region of the implantation, the pre-implant augmentation, and the length and diameter of the implants had no statistically significant influence on the survival or the success rate. The marginal bone level remained stable with only minimal loss of 0.3 mm after 60 months of loading. Conclusions: Within the limitations of this study, immediate loading is feasible for dental implants in edentulous jaws.

A retrospective clinical study of single short implants (less than 8 mm) in posterior edentulous areas

  • Kim, Sang-Yun;Ku, Jeong-Kui;Kim, Hyun-Suk;Yun, Pil-Young;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.191-196
    • /
    • 2018
  • PURPOSE. The goal of this study was to evaluate the clinical outcome of single short implants, less than 8 mm in length, placed in the posterior area. MATERIALS AND METHODS. A total of 128 patients (75 male and 53 female, mean age: $52.6{\pm}11.2years$) with 154 implants participated. Implant marginal bone loss, and survival and success rates were measured. RESULTS. The mean follow-up period was $51.35{\pm}24.97months$. A total of 128 implants, 8 mm in length, were placed in patients who had mean marginal bone loss of 0.75 mm. These implants had a survival rate of 95.3%. Twenty-six implants, 7 mm in length, were placed in areas with a mean marginal bone loss of 0.78 mm and had a survival rate of 96.2%. Both marginal bone loss and survival rate were not statistically different among the groups. In the maxilla, 34 implants showed a mean marginal bone loss of 0.77 mm and a survival rate of 97.1%. In the mandible, 120 implants showed a mean marginal bone loss of 0.75 mm and a survival rate of 95.0%. The average marginal bone loss around all implants was $0.76{\pm}0.27mm$ at the last follow-up review after functional loading. The survival rate was 95.6% and success rate was 93.5%. CONCLUSION. In our study, single short implants less than 8 mm in length in the posterior areas had favorable clinical outcomes.

하악구치부에서 Bicon 임플란트에 의해 지지되는 고정성 국소의치의 광탄성 응력분석 (A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH BICON IMPLANTS ON MANDIBULAR POSTERIOR AREA)

  • 강종운;김난영;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.412-424
    • /
    • 2004
  • Statement of problem: Several prosthetic options are available for the restoration of multiple adjacent implants. A passively fitting prosthesis has been considered a prerequisite for the success and maintenance of osseointegration. Passivity is a particular concern with multiple implants because of documented inaccuracies in the casting and soldering process. One way to avoid this problem is to restore the implants individually, however, the restorations of individual adjacent impants requires careful adjustment of interproximal contacts. Purpose: The purpose of this study was to compare the stress distribution pattern and amount surrounding Bicon implants with individual crowns and splinted restorations. Material and method: A photoelastic model of a human partially edentulous left mandible with 3 Bicon implants($4{\times}11mm$) was fabricated. For non-splinted restorations, individual crowns were fabricated on 3 abutments ($4{\times}0.65mm,\;0^{\circ}$, 2.0 mm post, Bicon Inc., Boston, USA) After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal ($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m)$), and heavy($80{\mu}m$). Splinted 3-unit fixed partial dentures were fabricated and cemented to the model. Changes in stress distribution under simulated non-loaded and loaded conditions(7.5, 15, 30 lb) were analyzed with a circular polaricope. Results: 1. Stresses were distributed around the entire body of fin in Bicon implants. 2. Splinted restorations were useful for distribution of stress around implants especially with higher loads. 3. By increasing the contact tightness between the individually restored three implants, the stress increased in the coronal portion of implants. Conclusions: Ideal adjustment of the contact tightness was important to reduce the stresses around individually restored Bicon implants.

Association between dental implants in the posterior region and traumatic occlusion in the adjacent premolars: a long-term follow-up clinical and radiographic analysis

  • Lee, Jae-Hong;Kweon, Helen Hye-In;Choi, Seong-Ho;Kim, Young-Taek
    • Journal of Periodontal and Implant Science
    • /
    • 제46권6호
    • /
    • pp.396-404
    • /
    • 2016
  • Purpose: The aim of this retrospective study was to determine the association between dental implants in the posterior region and traumatic occlusion in the adjacent premolars, using data collected during from 2002 to 2015. Methods: Traumatic occlusion in the adjacent premolars was assessed by examining clinical parameters (bleeding on probing, probing pocket depth, fremitus, and tooth mobility) and radiographic parameters (loss of supporting bone and widening of the periodontal ligament space) over a mean follow-up of 5 years. Clinical factors (gender, age, implant type, maxillary or mandibular position, opposing teeth, and duration of functional loading) were evaluated statistically in order to characterize the relationship between implants in the posterior region and traumatic occlusion in the adjacent premolars. Results: The study inclusion criteria were met by 283 patients, who had received 347 implants in the posterior region. The incidence of traumatic occlusion in the adjacent premolars was significantly higher for splinted implants (P=0.004), implants in the maxillary region (P<0.001), and when implants were present in the opposing teeth (P<0.001). The other clinical factors of gender, age, and duration of functional loading were not significantly associated with traumatic occlusion. Conclusions: This study found that the risk of traumatic occlusion in the adjacent premolars increased when splinted implants were placed in the maxillary molar region and when the teeth opposing an implant also contained implants.

Assessing changes of peri-implant bone using digital subtraction radiography

  • Kwon Ji-Yung;Kim Yung-Soo;Kim Chang-Whe
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.273-281
    • /
    • 2001
  • Digital subtraction radiography may be one of the most precise and noninvasive methods for assessing subtle density changes in peri-implant bone, providing additional diagnostic information on implant tissue integration in overall maintenance. The aims of this study were to evaluate density changes after first, second surgery of dental implant and to measure the amount of marginal bone loss 9 months after second surgery using digital subtraction radiography. Bone change around 30 screw-shaped implants in 16 patients were assessed on radiographs. 17 Branemark implants of 3.75mm in diameter(Nobel Biocare, Goteborg, Sweden), 2 Branemark implants of 5.0mm in diameter, 11 $Replace^{TM}$ implants of 4.3mm in diameter(Nobel Biocare, Goteborg, Sweden) were used. To standardize the projection geometry of serial radiographs of implants, customized bite block was fabricated using XCP film holder(Rinn Corporation, Elgin, IL.) with polyether impression material of Impregum(ESPE, Germany) and direct digital image was obtained. Qualitative and quantitative changes on radiographs were measured with Emago software(The Oral Diagnostic System, Amsterdam, Netherlands). The results were as follows: 1. The peri-implant bone density of 69.2% implants did not change and the peri-implant bone density of 30.8% implants decreased after 3 months following first surgery. 2. The crestal bone density of 53.9% implants decreased first 3 months after second surgery. The crestal bone density of 58.8% implants increased 9 months after second surgery. No density change was observed around the midportion of the implants after second surgery, 3. The amount of marginal bone loss between different kinds of implants showed no statistically significant differences (p>0.05). 4. More than 90% of total marginal bone loss recorded in a 9-month period occurred during the first 3 months.

  • PDF

Histomorphometry and stability analysis of early loaded implants with two different surface conditions in beagle dogs

  • Kim, Dong-Seok;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.10-18
    • /
    • 2009
  • STATEMENT OF PROBLEM. Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. PURPOSE. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions. MATERIAL AND METHODS. A total of 36 solid screw implants(diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed. RESULTS. Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels(P=.46) and RFA values. The mean BIC % in the Mg-implants was $54.5{\pm}8.4%$. The mean BIC % in the turned implant was $45.3{\pm}12.2%$. These differences between the Mg-implant and control implant were statistically significant(P=.005). CONCLUSIONS. The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact(BIC) in early loading conditions. CLINICAL IMPLICATIONS. The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.

Comparion of stability in titanium implants with different surface topographies in dogs

  • Kim, Nam-Sook;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.47-55
    • /
    • 2009
  • STATEMENT OF PROBLEM. A few of studies which compared and continuously measured the stability of various surface treated implants in the same individual had been performed. PURPOSE. We aim to find the clinical significance of surface treatments by observing the differences in the stabilization stages of implant stability. MATERIAL AND METHODS. Eight different surface topographies of dental implants were especially designed for the present study. Machined surface implants were used as a control group. 4 nano-treated surface implants(20 nm $TiO_2$ coating surface, heat-treated 80 nm $TiO_2$ coating surface, CaP coating surface, heat treated CaP coating surface) and 3 micro-treated surface implants [resorbable blast media(RBM) surface, sandblast and acid-etched(SAE) surface, anodized RBM surface] were used as experiment groups. All 24 implants were placed in 3 adult dogs. $Periotest^{(R)}$ & ISQ values measured for 8 weeks and all animals were sacrificed at 8 weeks after surgery. Then the histological analyses were done. RESULTS. In PTV, all implants were stabilized except 1 failed implants. In ISQ values, The lowest stability was observed at different times for each individual. The ISQ values were showed increased tendency after 5 weeks in every groups. After 4 to 5 weeks, the values were stabilized. There was no statistical correlation between the ISQ values and PTV. In the histological findings, the bone formation was observed to be adequate in general and no differences among the 8 surface treated implants. CONCLUSIONS. In this study, the difference in the stability of the implants was determined not by the differences in the surface treatment but by the individual specificity.