Effects of Static Magnetic Fields of Earphones and Headphones on Pacemakers and Implantable Cardioverter Defibrillators (이어폰 및 헤드폰의 정자기장이 인공심장 박동기 및 이식형 제세동기에 미치는 영향)

  • Chung, J.W.;Choi, S.B.;Park, J.S.;Kim, D.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.31-36
    • /
    • 2015
  • In this study, we evaluated the effects of static magnetic fields of earphones and headphones on pacemakers and implantable cardioverter defibrillators(ICDs). Five pacemakers and three ICDs were subjected to in-vitro test with three headphones which were an in-ear earphone, clip-on headphone, and closed-back headphone. Each implantable device was placed in close proximity(within 3 mm) to the ear-pad of each of the earphone and headphones for 3 min. As a result, no effects were observed on the pacemakers for the earphone and headphones during the test, but an effect was observed on one ICD for the clip-on and closed-back headphone during the test. When the ICD was placed in close proximity to the headphones, the ICD temporarily suspended functions of tachyarrhythmia detection and therapy. The effect was not observed in this study when the headphones were at least 2 cm from the ICD. Based on these findings, patients with ICDs should be advised to keep earphones and headphones at least 2 cm apart from their ICDs.

Development of a wireless telemetry system based on MICS standard (MICS 표준에 기반한 무선 텔레메트리 시스템 개발)

  • Lee, Seung-Ha;Park, Il-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.

Pinch-Off Syndrome, a Rare Complication of Totally Implantable Venous Access Device Implantation: A Case Series and Literature Review

  • Ilhan, Burak Mehmet;Sormaz, Ismail Cem;Turkay, Rustu
    • Journal of Chest Surgery
    • /
    • v.51 no.5
    • /
    • pp.333-337
    • /
    • 2018
  • Background: Pinch-off syndrome (POS) is a rare complication after totally implantable venous access device (TIVAD) implantation. In cancer patients, it is important to prevent this rare complication and to recognize it early if it does occur. We present a case series of POS after TIVAD implantation and the results of a literature search about this complication. Methods: From July 2006 to December 2015, 924 permanent implantable central venous catheter implantation procedures were performed. The most common indication was vascular access for chemotherapy. Results: POS occurred in 5 patients in our clinic. Two patients experienced POS within 2 weeks, and the other 3 patients were admitted to department of surgery, Istanbul Faculty of Medicine at 6 to 14 months following implantation. The catheters were found to be occluded during medication administration, and all patients complained of serious pain. The transected fragments of the catheters had migrated to the heart. They were successfully removed under angiography with a single-loop snare. Conclusion: POS is a serious complication after TIVAD implantation. It is important to be aware of this possibility and to make an early diagnosis in order to prevent complications such as drug extravasation and occlusion events.

Implantable Drug Delivery Systems-Design Process

  • Vincent, Croquet;Benolt, Raucent;Onori, Mauro
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.4
    • /
    • pp.40-46
    • /
    • 2006
  • The market of programmable implantable pumps has bound to a monopolistic situation, inducing high device costs, thus making them inaccessible to most patients. Micro-mechanical and medical innovations allow improved performances by reducing the dimensions. This affects the consumption and weight, and, by reducing the number of parts, the cost is also affected. This paper presents the procedure followed to design an innovative implantable drug delivery system. This drug delivery system consists of a low flow pump which shall be implanted in the human body to relieve pain. In comparison to classical known solutions, this pump presents many advantages of high interest in both medical and mechanical terms. The first section of the article describes the specifications which would characterize a perfect delivery system from every points of view. This concerns shape, medication, flow, autonomy, biocompatibility, security and sterilization ability. Afterwards, an overview of existing systems is proposed in a decisional tree. Positive displacement motorized pumps are classified into three main groups: the continuous movement group, the fractioned translation group and the alternative movement group. These systems are described and the different problems which are specific to these mechanisms are presented. Since none of them fully satisfy the specifications, an innovation is justified.. The decisional tree is therefore extended by adding new principles: fractioned refilling and fractioned injection within the fractioned translation movement group, spider guiding system within the alternative translation movement group, rotational bearing guided device and notch hinge guided device in the alternative rotation movement group.

Development and Evaluation of a Novel Electro-mechanical Implantable Ventricular Assist System (전기-기계식 이식형 좌심실 보조 시스템의 개발 및 평가)

  • 조한상;김원곤;이원용;곽승민;김삼성;김재기;김준택;류문호;류은숙
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.349-358
    • /
    • 2001
  • A novel electro-mechanical implantable ventricular assist system is developed as a bridge to transplantation or recovery for patients with end-stage heart failure. The developed system is composed of an implanted blood pump, an external monitoring system which stores data, and a wearable system including a portable external driver and a portable power supply system. The blood pump is designed to be implanted into the left upper abdominal space and provides blood flow from the left ventricular apex to the aorta. The pulsatile blood flow is generated by a double cylindrical cam. There was mo excessive heat emission from the blood pump into the temperature-controlled chamber in the heat test and no stagnated flow within the blood sac by the observation in the flow visualization test. Animal experiments were performed using sheep and calves. The maximum assist flow rate reached 7.85L/min in the animal experiment. The evaluation results showed that the developed system was feasible for the implantable ventricular assist system. The long-term in vitro durability test and mid-term in vivo experiments are in progress and mow the modified next model is under development.

  • PDF

Incomplete Removal of Totally Implantable Venous Devices : Report of 2 Cases (Totally Implantable Venous Devices (TIVD)의 불완전 제거 2예)

  • Son, Sang-Yong;Lee, Han-Byoel;Kim, Soo-Hong;Park, Taejin;Jung, Kyuhwan;Kim, Hyun-Young;Kim, Woong-Han;Jung, Sung-Eun
    • Advances in pediatric surgery
    • /
    • v.18 no.1
    • /
    • pp.18-23
    • /
    • 2012
  • Totally implantable venous devices (TIVD)는 장기간 항암 화학 요법이나 총 정맥 영양, 수액치료가 필요한 환자에서 많이 사용된다. TIVD는 매우 유용하고 안전한 장치이지만, 이와 관련된 다양한 합병증이 보고 되어 왔다. 저자들은 카테터의 혈관 내 유착에 의해 TIVD의 제거가 불완전하게 된 2예를 경험하였기에 보고하는 바이다.

  • PDF

Design of Implantable Wireless Sensor Node to Monitor the Livestock Body Temperature (가축의 실시간 체온 측정을 위한 이식형 무선 센서 노드 설계)

  • Kim, Hyun-Joong;Yang, Hyun-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.585-588
    • /
    • 2009
  • Wireless Sensor Network (WSN) is consisted of lots of tiny sensor nodes with limited processing power and computing resources. Thus, the most critical and fundamental element of WSN technology is sensor node, which gathers environmental information and transmits it to the user application systems. Due to the technological advancement, sensor nodes are become smaller and more intelligent, hence, expand their application area. Specifically, implantable wireless sensor node technology, to monitor and treat disease by implanting tiny sensor nodes into human body or livestock, shows further directions of WSN. In this paper, we have designed an implantable wireless sensor node to monitor livestock body temperature in real time. We also discussed on the additional considerations to implement real time bio-monitoring systems.

  • PDF

Performance Analysis of 403.5MHz CMOS Ring Oscillator Implemented for Biomedical Implantable Device (생체 이식형 장치를 위해 구현된 403.5MHz CMOS 링 발진기의 성능 분석)

  • Ferdousi Arifa;Choi Goangseog
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.19 no.2
    • /
    • pp.11-25
    • /
    • 2023
  • With the increasing advancement of VLSI technology, health care system is also developing to serve the humanity with better care. Therefore, biomedical implantable devices are one of the amazing important invention of scientist to collect data from the body cell for the diagnosis of diseases without any pain. This Biomedical implantable transceiver circuit has several important issues. Oscillator is one of them. For the design flexibility and complete transistor-based architecture ring oscillator is favorite to the oscillator circuit designer. This paper represents the design and analysis of the a 9-stage CMOS ring oscillator using cadence virtuoso tool in 180nm technology. It is also designed to generate the carrier signal of 403.5MHz frequency. Ring oscillator comprises of odd number of stages with a feedback circuit forming a closed loop. This circuit was designed with 9-stages of delay inverter and simulated for various parameters such as delay, phase noise or jitter and power consumption. The average power consumption for this oscillator is 9.32㎼ and average phase noise is only -86 dBc/Hz with the source voltage of 0.8827V.

Implementation of Fitting Software for Fully Implantable Middle Ear Hearing Device (완전 이식형 인공중이용 적합 소프트웨어의 구현)

  • Lee, J.W.;Jung, E.S.;Lim, H.K.;Lee, J.H.;Seong, K.W.;Kim, M.N.;Cho, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.3 no.1
    • /
    • pp.21-25
    • /
    • 2009
  • Generally, fully implantable middle ear hearing device (F-IMEHD) is implanted under the skin nearby human temporal bone with all components including implantable microphone and vibration transducer. The microphone and transducer have different characteristic before and after implant. Fitting process is performed for this characteristic change of them and proper performance of hearing aids for each patient. Conventional hearing aids and partially implantable hearing aids, they have wired connector for fitting process. However in case of F-IMEHD, it is difficult this wired connection, because all components of F-IMEHD is implanted. In this paper, fitting software that can be apply wireless fitting hardware for F-IMEHD has been designed and implemented. It can find out proper fitting parameter reflecting characteristics of the microphone and transducer for patients who has difficulty in hearing.

  • PDF

Design of External Coil System for Reducing Artifact of MR Image due to Implantable Hearing Aid (이식형 보청기에 의한 자기공명 영상의 인공음영 축소를 위한 외부 코일 시스템 설계)

  • Ahn, Hyoung Jun;Lim, Hyung-Gyu;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.375-385
    • /
    • 2016
  • Recently, several implantable hearing aids such as cochlear implant, middle ear implant, etc., which have a module receiving power and signal from outside the body, are frequently used to treat the hearing impaired patients. Most of implantable hearing aids are adopted permanent magnet pairs to couple between internal and external devices for the enhancement of power transmission. Generally, the internal device which containing the magnet in the center of receiving coil is implanted under the skin of human temporal bone. In case of MRI scanning of a patient with the implantable hearing aid, however, homogeneous magnetic fields of the MRI might be interfered by the implanted magnet. For the above reasons, the MR image is degraded by large area of artifact, so that diagnostics are almost impossible in deteriorated region. In this paper, we proposed an external coil system that can reduce the artifact of MR image due to the internal coupling magnet. By finite element analysis estimating area of MR artifact according to varying current and shape of the external coil, optimal coil parameters were extracted. Finally, the effectiveness of the proposed external coil system was verified by confirming the artifact at real MRI scan.