• Title/Summary/Keyword: Implant-supported fixed-prosthesis

Search Result 136, Processing Time 0.024 seconds

Implant Fixture Installation in the Anterior Mandible by Use of a Mucosa Supported Surgical Template Based on Computer Assisted Treatment Planning (컴퓨터보조 기반 점막지지 서지컬템프레이트를 이용한 하악전치부 임플란트 식립)

  • Lee, Jee-Ho;Kim, Soung-Min;Kim, Myung-Joo;Park, Jung-Min;Seo, Mi-Hyun;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.2
    • /
    • pp.158-165
    • /
    • 2011
  • A 73-year-old Korean female patient with a fully edentulous mandible was planned to have five implant fixtures installed in the anterior mandible for the fixed prosthesis. After 3-dimensional (3D) computed tomographic scanning was transferred to OnDemand3D$^{(R)}$ (Cybermed Co., Seoul, Korea) software program for the virtual planning, five fixtures of MK III Groovy RP implants of Branemark System$^{(R)}$ (Nobel Biocare AB Co., Goteborg, Sweden) were installed in the anterior mandible between both mental foramens using In2Guide$^{(R)}$ (CyberMed Co., Seoul, Korea) mucosa-supported surgical template with Quick Guide Kit$^{(R)}$ (Osstem Implant Co., Seoul, Korea) systems. Fixture installations were completed successfully without any complications, such as mental nerve injury, bony bleedings, fenestrations and other unexpected events. Postoperative computed tomographic scans were aligned and fused to the planned implant, then angular and linear deviations were compared with the planned virtual implants. The mean angular deviation between the planned and actual implant axes was $3.42{\pm}1.336^{\circ}$. The mean distance between the planned and actual implant at the neck area was $0.544{\pm}0.290$ mm horizontally and $0.118{\pm}0.079$ mm vertically. The average distance between the planned and actual implant at the apex area was $1.166{\pm}0.566$ mm horizontally and $0.14{\pm}0.091$ mm vertically. These results could be considered more precise and accurate than previous reports, and even our recent results. The entire procedures of this case are reported and reviewed.

Sinus floor elevation and implant-supported fixed dental prosthesis in the posterior area, with full-digital system: a case report (완전 디지털 시스템을 이용한 상악동 거상술 및 구치부 임플란트 고정성 보철 수복 증례)

  • Gang Soo Park;Sunjai Kim;Se-Wook Pyo;Jae-Seung Chang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.157-164
    • /
    • 2024
  • A variety of digital technologies are being used throughout the entire implant treatment process of diagnosis, surgery, impression, design, and fabrication of prostheses. In this case, using a digital surgical guide, sinus floor elevation was performed without complications, and the implants were placed in the planned position. After the healing period for osseointegration, CAD-CAM (Computer-aided design-Computer-aided manufacturing) customized abutments and provisional prostheses were delivered. While using the provisional prosthesis, occlusal change was observed. To transfer the intermaxillary relationship and abutment position that reflect occlusal change and axial displacement, double scanning and abutment-level digital impressions were taken. Abutment superimposition was used to capture the subgingival margin without gingival retraction. Then, the definitive prosthesis was designed and fabricated with digital system. We report a case applying digital system, to achieve the predictable result as well as the efficient treatment process from implant surgery to fabricating prosthesis in the posterior area.

Implant assisted removable partial denture using bilateral single implant-supported surveyed crown: a case report (양측성 단일 임플란트 지지 서베이드 크라운을 이용한 하악 임플 란트 보조 국소의치 수복 증례)

  • Seojune Choi;Hong Seok Moon;Jaeyoung Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Implant assisted removable partial denture (IARPD) has been practiced in various forms for a long time, and among them, implant surveyed crown RPD is gaining predictability as well as being considered as a treatment option for patients with anatomical and financial disadvantages. The position of implant could be divided as posterior placement or anterior placement according to the purpose of the treatment and should be planned in consider to the alveolar ridge of patient, anticipated prognosis of remaining teeth, and opposing dentition. This case report describes a treatment for mandibular Kennedy class I partial edentulous patient with two implant-supported surveyed crown and implant assisted removable partial denture. Given the difficulty of posterior placement in this patient and the prognosis of the residual teeth, the plan was to place two implants in close proximity to the residual teeth, which were placed in the planned position, angle, and depth using guided surgery. The process of fabricating the fixed prosthesis was carried out in parallel with the maxillary edentulous tooth arrangement process to increase predictability, and when fabricating the localized tooth, the implant was designed in a form that allows the patient to perform functional movements by preventing excessive loading as the last supporting tooth, and was fabricated through a secondary impression process. Each treatment procedure was proceeded as planned, with aesthetically and functionally satisfactory results for both patient and operator.

Narrow-diameter implants with conical connection for restoring the posterior edentulous region

  • Woo, In-Hee;Kim, Ju-Won;Kang, So-Young;Kim, Young-Hee;Yang, Byoung-Eun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.31.1-31.7
    • /
    • 2016
  • Background: The objective of this retrospective study was to show results from platform-switched narrow-diameter implants in the posterior edentulous region, which we followed up for more than 1 year after functional loading. Methods: Ninety-eight narrow implants were inserted into 66 patients. After healing, fixed implant-supported prostheses were delivered to the patients, and Periotest and radiographic examinations were performed. After the first year of loading, the implant outcome was again evaluated clinically and radiographically using the Periotest analysis. Crestal bone loss and Periotest values (PTVs) were used to evaluate the effect of surgery, prosthesis, implant, and a host-related factor. A general linear model was used to statistically detect variables statistically associated with crestal bone loss and Periotest value. Results: We followed up on the implants over 1 to 4 years after loading; their survival rate was 100 %, and pronounced differences from PTVs were noted among jaw location, bone quality, and loading period. No difference was detected in bone loss among the variables studied. Bone loss after functional loading was $0.14{\pm}0.39mm$. The stability value from the Periotest was $-3.29{\pm}0.50$. Conclusions: Within the limitations of this study, judicious use of platform-switched narrow implants with a conical connection must be considered an alternative for wide-diameter implants to restore a posterior edentulous region.

Korea Academy of Prosthodontics criteria for longevity studies of dental prostheses (보철물 수명 연구를 위한 대한치과보철학회 표준 방안: KAP Criteria)

  • Yoon, Joon-Ho;Park, Young-Bum;Youn, Seung-Hwan;Oh, Nam-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.341-353
    • /
    • 2016
  • Purpose: The most important factor in longevity studies of dental prostheses is objective and consistent evaluation of the prosthesis. The Korean Academy of Prosthodontics suggested developing a standardized method for longevity studies of dental prostheses. The purpose of this study is to evaluate previously-used criteria and to develop new criteria, in the form of a procedure flowchart and an evaluation sheet. These new criteria may be able to provide a unified standard for future longevity studies of dental prostheses. Materials and methods: A literature review was performed about the evaluation of dental prostheses. Taking into account the strengths and weaknesses of previously used criteria, a novel, intuitive and objective method was developed for assessment of dental prostheses. Then, a pilot survey was performed with the newly developed flowchart and evaluation sheet to determine problems and implement possible improvements. Results: Thirty cases of fixed dental prosthesis (FDP), 25 cases of removable dental prosthesis (RDP), and 13 cases of implant supported prosthesis (ISP) were evaluated. The average life expectancy estimate was 12.82 years for FDP, 5.96 years for RDP, and 4.82 years for ISP with Kaplan-Meier survival analysis. Additionally, possible improvements discovered by the pilot survey were reflected in the flowchart and evaluation sheet. Conclusion: The newly developed KAP criteria, flowchart and evaluation sheet enabled objective and consistent results in trial longevity studies of dental prostheses. It is expected that future studies will not only use the KAP criteria but also further improvement will be made on them.

An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level (임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구)

  • Shin, Dong-Hwan;Cho, Kyoo-Sung;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

Analysis of implant strain value exerted using different screw tightening protocols in screw-retained 3-unit prostheses (3본 나사 유지형 임플란트 보철물의 고정 방식에 따른 임플란트 고정체 치경부에 발생하는 변형율 비교분석)

  • Kim, Sang-Beom;Lee, Du-Hyeong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.321-327
    • /
    • 2020
  • Purpose: The purpose of this study was to measure and compare the strain value exerted on the cervical area using different screw tightening protocols in implant-supported, screw-retained 3-unit prostheses. Materials and methods: Strain gauges were attached to four implants: two external and two internal. Thereafter, two study model were designed each type using acrylic resin. CAD-CAM was used to design hex and nonhex abutments for each group (EH, ENH, IH, and INH group) and Screw-cement-retained prostheses were also designed using a nonprecious base metal. Abutment was fixed with 10 Ncm torque, and the prosthesis was cemented. Screws were fixed with 30 Ncm torque using different three protocols. After 5 min, the strain gauge level was measured, and group analysis was performed (α=.05). Results: External group showed significantly lower strain values than internal group and the EH group showed significantly lower strain values than the ENH group (P<.05). There was no difference in strain value based on the types of screw tightening protocols in same group (P>.05). The IH group exhibited significantly higher strain values than the INH group and the IH group showed a significant difference in strain values based on the types of screw tightening protocols used (P<.05). Conclusion: There was no significant effect on the external type in the implant-supported, screw-retained prostheses. However, strain values were high in the internal type, and the types of screw tightening protocol significantly affected these implants.

Clinical outcomes of implant supported fixed-hybrid prostheses in the fully edentulous arches (완전무치악 환자에서 고정성 임플란트 하이브리드 수복물의 임상성적)

  • Huh, Yoon-Hyuk;Yi, Yang-Jin;Kwon, Min-Jung;Kim, Young-Kyun;Cha, Min-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.183-189
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate clinical outcomes of implant supported fixed-hybrid prostheses (FHP) in the fully edentulous arches. Materials and methods: Patients in this retrospective study were restored with fixed-hybrid prostheses supported by 4 to 6 implants and functioned more than 1 year of loading. Outcome measures were marginal bone change of implant related with sex, anatomical location (maxilla vs. mandible), opposing teeth, loading time of patients, tilting of posterior implant by Mann- Whitney U test and cantilever length of superstructure by regression analysis, and complication rates. Significance level was set P<.05. Results: A total number of 84 implants (16 restorations) placed in 16 patients were observed for 28 months and mean marginal bone loss was $0.53{\pm}0.39mm$. There were no differences of marginal bone loss according to sex, anatomical location (maxilla vs. mandible), opposing teeth, loading time of patients (P>.05), and cantilever length was not significantly related with a marginal bone loss of implant next to cantilever (P>.05). Complication was shown in 11 patients and veneer fracture and dislodging of artificial teeth were most prevalent. Conclusion: Within the limitations of this study, although marginal bone loss of FHP was very little, complication rates were high. Irrespective of tilting of most posterior implants, marginal bone loss of most posterior implants next to cantilever was less than those of the other implants positioned anteriorly. Cantilever length (<17 mm) did not affect a marginal bone loss of most posterior implants.

A case of oral rehabilitation using implant fixed prosthesis (skeletal class III malocclusion patient) (골격성 III급 부정교합을 가진 환자에서 임플란트 지지 고정성 보철을 이용한 구강회복 증례)

  • Minjung Kang;Minji Sun;Hong Seok Moon;Jong-Eun Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.125-134
    • /
    • 2023
  • When the patient with class III malocclusion needs extensive oral rehabilitation due to multiple missing teeth, accurate diagnosis, and careful analysis, such as the patient's occlusal relationship, facial changes, and evaluation of the temporomandibular joint are essential. Orthognathic surgery is often performed for aesthetic improvement, depending on the patient's chief complaint. If it is not possible due to certain circumstances, partial aesthetic improvement can be achieved through minimal elevation of the vertical dimension. As this patient may have unexpected issues, such as temporomandibular joint disorder, oral habits like bruxism, and masticatory muscle tension, it was determined whether the patient could adjust to a reversible temporary removable partial denture. After this, the maxillary implant-supported fixed prostheses and the mandibular fixed prostheses were used to achieve stable posterior support and to partially improve the maxillary anterior esthetics. The patient was satisfied with the results both aesthetically and functionally. The prognosis is expected to be good if regular check-ups are conducted.

Rehabilitation using milled-bar with attachment maxilla overdenture in a patient with peri-implantitis fixed prosthesis: A case report (임플란트 주위염이 발생한 고정성보철 환자에 상악 Milled-bar와 부착장치를 이용한 피개의치로 수복한 증례)

  • Joon-Myung Lee;So-Yeun Kim;Du-Hyeong Lee;Kyu-Bok Lee;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.123-130
    • /
    • 2024
  • There are various methods for restoring the dentition of completely edentulous patients. Removable complete dentures have the advantage of being relatively economical, but they can be uncomfortable to wear. With the introduction of implant prosthodontics, various options such as implant-supported overdentures and hybrid prostheses have become available. If there is inadequate remaining ridge or limited financial resources, an overdenture supported by a few implants with additional attachments may be more suitable. In this case, due to severe peri-implantitis and other complications, the implants were removed. Subsequently, four implants (two on each side) were placed in the maxilla and a milled-bar with attachment was fabricated for each side of the maxilla.