• 제목/요약/키워드: Implant type and surface

검색결과 158건 처리시간 0.024초

A retrospective study on related factors affecting the survival rate of dental implants

  • Jang, Hee-Won;Kang, Jeong-Kyung;Lee, Ki;Lee, Yong-Sang;Park, Pil-Kyoo
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.204-215
    • /
    • 2011
  • PURPOSE. The aim of this retrospective study is to analyze the relationship between local factors and survival rate of dental implant which had been installed and restored in Seoul Veterans Hospital dental center for past 10 years. And when the relationship is found out, it could be helpful to predict the prognosis of dental implants. MATERIALS AND METHODS. A retrospective study of patients receiving root-shaped screw-type dental implants placed from January 2000 to December 2009 was conducted. 6385 implants were placed in 3755 patients. The following data were collected from the dental records and radiographs: patient's age, gender, implant type and surface, length, diameter, location of implant placement, bone quality, prosthesis type. The correlations between these data and survival rate were analyzed. Statistical analysis was performed with the use of Kaplan-Meier analysis, Chi-square test and odds ratio. RESULTS. In all, 6385 implants were placed in 3755 patients (3120 male, 635 female; mean age $65{\pm}10.58$ years). 108 implants failed and the cumulative survival rate was 96.33%. There were significant differences in age, implant type and surface, length, location and prosthesis type (P<.05). No significant differences were found in relation to the following factors: gender, diameter and bone quality (P>.05). CONCLUSION. Related factors such as age, implant type, length, location and prosthesis type had a significant effect on the implant survival.

방사선 조사 후 매식한 임프란트의 표면 종류와 스테로이드 관주에 따른 골 치유 효과에 대한 조직 형태학적 연구 (HISTOMORPHOMETRIC STUDY ON THE INFLUENCE OF STEROID TOPICAL IRRIGATION AND IMPLANT SURFACE ON BONE HEALING IN THE IRRADIATED RABBIT TIBIA)

  • 신성수;박양호;박준우;이건주;김현만;고재승
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권6호
    • /
    • pp.455-464
    • /
    • 2004
  • The purpose of this study was to evaluate and compare the influence of Steroid topical irrigation and implant surface on bone healing in the irradiated rabbit tibia. Implant to bone contact surface ratio and the pattern of bone healing around hydroxyapatite(HA) coated implant and pure titanium (Ti) implant which were inserted into the irradiated rabbit tibia were compared. 16 Korean house mature male rabbits were used as experimental animal. Each rabbit received 15 Gy of irradiation. 4 weeks after the irradiation, two holes were prepared in the irradiated tibia of each rabbits, where two surface type of implants were inserted :1) HA coated type and 2) pure Ti type. Right before placing implants, one group of rabbit received steroid irrigation and the other group did saline. After the irrigation, two implants of HA coated type and pure Ti type were inserted into the tibia of each rabbits. Each rabbit were sacrificed at 2nd, 4th, and 8th week after the implantation and the specimens were observed by the light microscope. The pattern of bone healing and histomorphometric analysis of the implant-bone interface were done. The results were as follows. 1. All implants inserted into the irradiated tibia of rabbit did not show any sign of clinical mobility and the bone around implants inserted into the irradiated tibia of rabbit did not show any resorption. 2. The bone to implant contact surface ratio around HA coated implants that received steroid irrigation got more bone to implant contact surface ratio than that of the saline irrigation. This result showed statistically significant(p<0.05). There was no statistically significant difference in 8th week group. 3. Though there was no statistically significant difference HA coated implants had more bone to implant contact surface ratio than pure Ti implant in 2nd and 4th groups, and there was no difference in 8th week group. 4. All implants inserted into the irradiated tibia of rabbit had exhibited successful osseointegraion.

Cemented type implant에서 지대치의 표면조도와 cement의 종류가 Retrievability에 미치는 영향에 관한 연구 (THE RETRIEVABILITY OF CEMENTATION TYPE IMPLANT ABUTMENT BY SURFACE TREATEMENTS AND TYPES OF CEMENTS)

  • 이재봉
    • 대한치과보철학회지
    • /
    • 제37권5호
    • /
    • pp.651-657
    • /
    • 1999
  • This study was performed to investigate the retrievability of the cementation type implant abutments. The cements used in this study were Cavitec, Tembond and Zinc Phosphate Cement. The types of surface conditioning were no treatment, 50 microne sandblasting, 250 microne sandblasting, fine diamond finishing point and coarse diamond point. The retention of cast crown was measured with Instron Universal Testing Machine(Instron Engineering Co., U.S.A.). The results were as fellows: 1. The Maximium retention was obtained by the group of Z.P.C. cementation and Coarse diamond point surface conditioning. 2. Z.P.C. shows maximum retention, and reduced in orders Tembond, Cavitec, No cement. 3. The value of retention of surface condition was highest in coarse diamond point, lowest in no tretment. 4. The similar results were obtained between fine diamond point and 50 microne sandblasting, coarse diamond point and 250 microne sandblasting. 5. The were no direct corelation between mechanical retention and cementation retention.

  • PDF

단일치아 결손시 $TiUnite^{TM}$ 표면처리한 임플란트의 생존율에 대한 후향적 단기연구 (A 3 year-retrospective study of survival rate in single $Br{\aa}nemark$ $TiUnite^{TM}$ implant)

  • 양승민;박선혜;신승윤;계승범
    • Journal of Periodontal and Implant Science
    • /
    • 제37권4호
    • /
    • pp.671-679
    • /
    • 2007
  • Background: $TiUnite^{TM}$ is a highly crystalline and phosphate enriched titanium oxide surface which has a unique porous surface structure. This improved implant surface enhances bone response and reduces healing period. It also assures early stability of implant. These help to increase the success of implant. The aim of this study is to evaluate the survival rate of $TiUnite^{TM}$ surfaced single implant. Materials and methods: A retrospective analysis of 89 $TiUnite^{TM}$ surfaced implants replacing a single tooth was assessed according to their dental record. The age of the patients ranged from 17 to 82 years (mean age: $45.8{\pm}14.6)$. Data were recorded regarding the survival rate of these implants. Results: Fifty-two implants (57%) were placed in the maxilla, and 37 (43%) in the mandible. Over 75% were placed in the posterior area. Of the placed implants, 67% were the wide type. while 25% were the regular type and only 8% were of the narrow type. The single implants produced an overall clinical survival rate of 96.6% over the observation period (mean 17.9 months). Among 89 implants, only 2 implants were removed and one implant was submerged. Conclusion: According to these data, $TiUnite^{TM}$ surfaced implant in a single tooth restoration showed favorable survival rate although this study was done in a short term period.

임플란트의 생존율에 영향을 미치는 국소적 인자에 대한 19년간의 후향적 연구 (The effects of local factors on the survival of dental implants: A 19 year retrospective study)

  • 김성회;김선재;이근우;한동후
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.28-40
    • /
    • 2010
  • 연구 목적: 임플란트의 성공과 실패는 숙주 관련 요인, 위치 관련 요인, 수술 관련 요인, 임플란트 관련 요인, 수복물 관련 요인 등 다양한 인자에 의해 결정된다. 본 연구는 그 중 임플란트의 식립 위치, 골질, 임플란트 표면, 길이 및 직경, 초기 안정성, 보철물 유형이 생존율에 미치는 영향을 평가하여, 임플란트의 예후를 예측하는데 도움을 주고자 한다. 연구 재료 및 방법: 1991년 2월부터 2009년 5월 사이에 연세대학교 치과대학병원에서 5인의 외과의가 임플란트 수술을 시행하고, 1인의 보철 전문의에 의해 보철 수복이 이루어져 적어도 6개월 이상 보철물에 대한 주기적인 검사가 이루어진 879명환자, 2796개의 임플란트에 대한 후향적 연구를 시행하였다. 진료 기록부 및 방사선 사진을 통해 환자의 식립 당시 나이와 성별, 임플란트의 제조회사, 표면, 직경 및 길이, 식립 부위 및 골질, 초기 안정성, 보철물의 유형, 생존 기간에 관한 자료를 수집하였다. 이를 통해, 임플란트의 성공과 실패에 영향을 미치는 국소 인자의 유형, 분포 및 국소 인자와 생존율 간의 관계를 연구하였다. 생존율 분석은 Kaplan-Meier 생존 분석법을 이용하였으며, 평가 인자 내 항목들의 생존율 비교는 Chi-square test를 사용하였다. 또한, 임플란트의 실패 위험성을 평가하기 위해 오즈비 (odds ratio)를 구하였다. 결과: 1. 총 879명에게 식립된 2796개의 임플란트 중 150개가 실패하여 누적 생존율은 94.64%로 나타났다. 그 중 기계 절삭 표면 임플란트의 누적 생존율은 91.76%, 거친 표면 임플란트의 누적 생존율은 96.02% 이었다. 2. 식립위치, 임플란트의 표면 특성, 기계 절삭 표면 임플란트의 직경, 초기 안정성, 보철물 유형, 환자의 연령 및 성별이 생존율에 미치는 영향은 통계학적으로 유의하였다 (P<.05). 3. 식립 부위의 골질, 임플란트 제조사별 거친 표면 특성, 임플란트의 길이 및 기계 절삭 표면을 제외한 거친 표면 임플란트의 직경이 생존율에 미치는 영향은 통계학적으로 유의하지 않았다 (P>.05). 4. 특히, 실패율이 높은 경우는 상악 구치부에 식립 시 (8.84%), 기계 절삭 표면의 임플란트 식립 시 (8.24%), 기계 절삭 표면 임플란트 중 wide 직경을 사용하는 경우 (14.47%), 초기 고정이 불량한 경우 (28.95%), 상악에 implant retained overdenture (기계 절삭 표면 26.69%; 거친 표면 10%) 및 telescopic denture (기계 절삭 표면 100%; 거친 표면 27.27%)로 수복하는 경우, 60-79세 환자에게 식립하는 경우 (6.90%), 남성에게 식립하는 경우 (6.36%) 이었다.

Resonance Frequency Analysis(RFA)를 이용한 임플란트 종류간의 초기 안정성 비교 (Comparison of initial implant stability measured by Resonance Frequency Analysis between different implant systems)

  • 오준호;장문택
    • Journal of Periodontal and Implant Science
    • /
    • 제38권3호
    • /
    • pp.529-534
    • /
    • 2008
  • Purpose: The objective of this study was to compare initial implant stability measured by RFA between different implant systems during the initial healing period. Material and Methods: Fifty-four patients (36 males/18 females) who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital during the period between January and November in 2007 were included in the study. The mean age of the subjects was 49 years old (18 to 77). A total of 104 implants (Type A: 3i $Osseotite^{(R)}$, Type B: $Replace^{(R)}$ select, Type C: ITI implant) were placed following the manufacturer's standard surgical protocols. Implant stability quotient (ISQ) readings were obtained for each implant at the time of surgery, 2-, and 4-month postoperatively. Result: No implant was failed during the observation period. At the baseline, the difference between mean ISQ values of 3 implant systems was statistically significant (p<0.05). However, at 2-, and 4-month following implant surgery, no significant difference was observed between ISQ values of the implant systems. In the same implant, the ISQ values of Type B and C implants increased (p<0.05), but those of Type A implants decreased during the 2-month healing period. The mean ISQ values of Type B and C implants showed a increasing tendency, while those of Type A implants were stable for the 4-month follow-up period. Conclusion: Within limits of this study, it can be concluded that implant design and surface topography of implant might influence the ISQ value and changing pattern during the initial healing period.

$PerioTest^{(R)}$를 이용한 임플란트 동요도에 관한 임상적 연구 ([ $PERIOTEST^{(R)}$ ] ASSESSMENT OF DENTAL IMPLANT MOBILITY : A CLINCAL STUDY)

  • 김선재;한동후
    • 대한치과보철학회지
    • /
    • 제36권5호
    • /
    • pp.758-771
    • /
    • 1998
  • Assessment of implant mobility is an important and reliable method to clinically evaluate implant stability. PerioTest is a precise and reproducible device that cam dynamically measure the reaction of damping characteristics of peri-implant tissue. The aim of this study is to evaluate the effects of amount of implant surface area, diameter, type, implantation site, degrees of cortical engagement, and length of time in function on PTVs and to find out the most determining factor on PTVs. The results are as follows 1. 5.0mm diameter implants show significantly lower PTV than that of 3.75mm diameter implants. 2. PTV in the mandible is significantly lower than that of the maxilla 3. In the maxilla, there is no significant difference in PTV during the first year of implant function, but during the second year a significant decrease in PTV is noted. 4. In the mandible, there is a significant decrease in PTV during the first and second year of implant function. 5. Implantation site seems to be the most determining factor on PTV among the influencing factors in this study. In conclusion, the amount of implant surface area, type, degrees of cortical engagement had no significant effect on PTV, but installation site and diameter influenced significantly on PTV

  • PDF

Ti-6Al-4V 비드코팅 임프란트 시제품의 골유착에 대한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE OSSEOINTEGRATION OF THE TI-6AL-4V BEAD COATING IMPLANTS)

  • 우진오;박봉욱;변준호;김승언;김규천;박봉수;김종렬
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권1호
    • /
    • pp.52-59
    • /
    • 2008
  • The geometric design of an implant surface may play an important role in affecting early osseointegration. It is well known that the porous surfaced implant had much benefits for the osseointegration and the early stability of implant. However, the porous surfaced implant had weakness from the transgingival contamitants, and it resulted in alveolar bone loss. The other problem identified with porous surface implant is the loss of physical properties resulting from the bead sintering process. In this study, we developed the new bead coating implant to overcome the disadvantages of porous surfaced implant. Ti-6Al-4V beads were supplied from STARMET (USA). The beads were prepared by a plasma rotating electrode process (PREP) and had a nearly spherical shape with a diameter of 75-150 ${\mu}m$. Two types of titanium implants were supplied by KJ Meditech (Korea). One is an external hexa system (External type) and the other is an internal system with threads (Internal type). The implants were pasted with beads using polyvinylalcohol solution as a binder, and then sintered at 1250 $^{\circ}C$ for 2 hours in vacuum of $10^{-5}$ torr. The resulting porous structure was 400-500 ${\mu}m$ thick and consisted of three to four bead layers bonded to each other and the implant. The pore size was in the range of 50-150 ${\mu}m$ and the porosity was 30-40 % in volume. The aim of this study was to evaluate the osseointegration of the newly developed dental implant. The experimental implants (n=16) were inserted in the unilateral femur of 4 mongrel dogs. All animals were killed at 8 weeks after implantation, and samples were harvested for hitological examination. All bead coated porous implants were successfully osseointegrated with peripheral bone. The average bone-implant contact ratios were 84.6 % (External type) and 81.5 % (Internal type). In the modified Goldner's trichrome staining, new generated mature bones were observed at the implant interface at 8 weeks after implantation. Although, further studies are required, we could conclude that the newly developed vacuum sintered Ti-6Al-4V bead coating implant was strong enough to resist the implant insertion force, and it was easily osseointegrated with peripheral bone.

다양한 양극산화막 처리방법이 임프란트 골유착에 미치는 영향 (EFFECT OF VARIOUS INODIZING CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANT SURFACE DESIGN)

  • 차수련;이준;민승기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권5호
    • /
    • pp.417-427
    • /
    • 2008
  • The aim of this study is to investigate the effect of anodizing surface to osseointegration of implant by using of resonance frequency analysis (RFA), quantitative and qualitative assessment of an anodically modified implant type with regard to osseous healing qualities. A total of 96 screw-shaped implants were prepared for this study. 72 implants were prepared by electrochemical oxidation with different ways. 24 (group 1 SP) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid. 24 (group 2GC) were prepared at galvanostatic mode in calcium glycerophosphate and calcium acetate and 24 (group 3 CMP (Calcium Metaphosphate) Coating were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid followed by CMP coating. Rest of 24 (control group were as a control group of RBM surface. Bone tissue responses were evaluated by resonance frequency analysis (RFA) that were undertaken at 2, 4 and 6 weeks after implant placement in the mandible of mini-pig. Group 1 SP (anodized with sulfuric acid and phosphoric acid implants) demonstrated slightly stronger bone responses than control Group RBM. Group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) demonstrated no difference which were compared with control group. Group 3 GMP (anodized and CMP coated implants) demonstrated slightly stronger and faster bone responses than any other implants. But, all observation result of RF A showed no significant differences between experimental groups with various surface type. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact for group 2 GC. Significantly more bone formation was found inside threaded area for group 2 GC. It was concluded that group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) showed more effects on the bone tissue responses than RBM surface in initial period of implantation. In addition, CMP showed a tendency to promote bone tissue responses.

임플란트주위염시 Porphyromonas gingivalis 섬모유전형의 출현율 (Prevalence of fimA Genotypes of Porphyromonas gingivalis Strains in peri-implantitis patients)

  • 신승일;권영혁;박준봉;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제35권1호
    • /
    • pp.31-41
    • /
    • 2005
  • Fimbriae (fimA) of Porphyromonas gingivalis are filamentous components on the cell surface and are thought to play an important role in the colonization and invasion of periodontal tissue. P. gnigivalis fimA gene encoding fimbrillin, a subunit of fimbriae, has been classified into 5 genotypes (types I to V) based on the nucleotide sequences. In the present study, we examined the prevalence of these fimA genotypes in patients with dental implant and the relationship between prevalence of these genotypes and peri-implantitis. Dental plaque specimens obtained from 80 peri-implant sulci of 50 patients with dental implants were analyzed by 16S rRNA fimA gene-directed PCR assay. P. gingivalis were detected in 74.4% of the samples of the control group (healthy peri- implant sulci; probing depth<5mm) and in 92.0% of the samples of the test group (peri-implant sulci with peri-iimplantitis; probing $depth{\geqq}5mm$). Among the P. gingivalis-positive samples of the control group, the most prevalent fimA type was type I (29.3%), followed by type II (26.8%). In contrast, a majority among the P. gingivalis-positive samples of the test group was type II (56.S%), followed by type I (43.5%). TypeII fimA genotype organisms were detected more frequently in the test group and a significant difference in the occurrence of type II was observed between test and the control groups. A correlation between specific fimA types and peri-implant health status was found in type II (OR 3.545) and only a weak relationship was revealed in typeIV(OR 3.807). These findings indicate that P. gingivalis strains that possess type II fimA are predominant in peri-implant sulci with peri-implantitis and are closely associated with peri-implant health status. P. gingivalis with type II fimA may be involved in peri-implantitis.