• Title/Summary/Keyword: Implant maintenance

Search Result 161, Processing Time 0.026 seconds

Early radiographic diagnosis of peri-implantitis enhances the outcome of peri-implantitis treatment: a 5-year retrospective study after non-surgical treatment

  • Chang, Hee-Yung;Park, Shin-Young;Kim, Jin-Ah;Kim, Young-Kyun;Lee, Hyo-Jung
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.3
    • /
    • pp.82-93
    • /
    • 2015
  • Purpose: This retrospective study evaluated the relationship between the timing of peri-implantitis diagnosis and marginal bone level after a 5-year follow-up of non-surgical peri-implantitis treatment. Methods: Thirty-three patients (69 implants) were given peri-implantitis diagnosis in 2008-2009 in Seoul National University Bundang Hospital. Among them, 31 implants from 16 patients were included in this study. They were treated non-surgically in this hospital, and came for regular maintenance visits for at least 5 years after peri-implantitis treatment. Radiographic marginal bone levels at each interval were measured and statistical analysis was performed. Results: Timing of peri-implantitis was one of the significant factors affecting initial bone loss and total bone loss not additional bone after peri-implantitis diagnosis. Patients with cardiovascular disease and diabetic mellitus were positively influenced on both initial bone loss and total bone loss. Patients who needed periodontal treatment after implant placement showed a negative effect on bone loss compared to those who needed periodontal treatment before implant placement during entire periods. Implant location also significantly influenced on amounts of bone loss. Mandibular implants showed less bone loss than maxillary implants. Among surgical factors, combined use of autogenous and xenogenic bone graft materials showed a negative effect on bone loss compared to autogenous bone graft materials. Use of membrane negatively affected on initial bone loss but positively on additional bone loss and total bone loss. Thread exposure showed positive effects on initial bone loss and total bone loss. Conclusions: Early peri-implantitis diagnosis led to early non-surgical intervention for peri-implantitis treatment, which resulted in the maintenance of the bone level as well as preservation of the implant.

Stress Analysis of Hybrid Implant Using Finite Element Method (유한요소법을 이용한 하이브리드형 임플란트의 응력해석)

  • Kwon, Young-Doo;Jang, Suck-Ho;Park, Sang-Hyun;Lee, Sang-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.3
    • /
    • pp.290-296
    • /
    • 2008
  • After scientific verification of the osteointegration of dental implants, the overall efficiency of dental implants has been generally accepted. Thus, implants now play a major role in the clinical treatment of an edentulous mandible, and in the prosthetic maintenance equipment for partial edentulous mandible patients. Yet, for the successful long-term maintenance of implants, careful consideration of the bio-mechanics is needed to ensure that the maximum stress in the mandible as a result of chewing is maintained under a critical value. Accordingly, this study focuses on reducing the maximum stresses in an implanted mandible, especially in the cortical bone. Thus, the stresses in the implant and mandible are analyzed using finite element packages, including I-DEAS and NISA II/DISPLAY III, using a local zooming technique for a concentrated stress analysis. In addition, the von-Mises stress and principal stress in the mandible are both checked to determine the best combination.

An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level (임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구)

  • Shin, Dong-Hwan;Cho, Kyoo-Sung;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.325-332
    • /
    • 2014
  • PURPOSE. The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS. A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clinical trials (RCT) and clinical trial studies comparing attachment systems on mandibular implant overdentures until December, 2011 were selected. Twenty nine studies were finally selected and the data about evaluation methods were collected. RESULTS. Evaluation criteria could be classified into 4 groups (implant survival, peri-implant tissue evaluation, prosthetic evaluation, and patient satisfaction). Among 29 studies, 21 studies presented implant survival rate, while any studies reporting implant failure did not present cumulative implant survival rate. Seventeen studies evaluating peri-implant tissue status presented following items as evaluation criteria; marginal bone level (14), plaque Index (13), probing depth (8), bleeding index (8), attachment gingiva level (8), gingival index (6), amount of keratinized gingiva (1). Eighteen studies evaluating prosthetic maintenance and complication also presented following items as evaluation criteria; loose matrix (17), female detachment (15), denture fracture (15), denture relining (14), abutment fracture (14), abutment screw loosening (11), and occlusal adjustment (9). Atypical questionnaire (9), Visual analog scales (VAS) (4), and Oral Health Impact Profile (OHIP) (1) were used as the format of criteria to evaluate patients satisfaction in 14 studies. CONCLUSION. For evaluation of implant overdenture, it is necessary to include cumulative survival rate for implant evaluation. It is suggested that peri-implant tissue evaluation criteria include marginal bone level, plaque index, bleeding index, probing depth, and attached gingiva level. It is also suggested that prosthetic evaluation criteria include loose matrix, female detachment, denture fracture, denture relining, abutment fracture, abutment screw loosening, and occlusal adjustment. Finally standardized criteria like OHIP-EDENT or VAS are required for patient satisfaction.

Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment

  • Seo, Yong-Ho;Bae, Eun-Bin;Kim, Jung-Woo;Lee, So-Hyoun;Yun, Mi-Jung;Jeong, Chang-Mo;Jeon, Young-Chan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.4
    • /
    • pp.313-320
    • /
    • 2016
  • PURPOSE. The aim of this study was to evaluate the clinical findings and patient satisfaction on implant overdenture designed with Locator implant attachment or Locator bar attachment in mandibular edentulous patients. MATERIALS AND METHODS. Implant survival rate, marginal bone loss, probing depth, peri-implant inflammation, bleeding, plaque, calculus, complications, and satisfaction were evaluated on sixteen patients who were treated with mandibular overdenture and have used it for at least 1 year (Locator implant attachment: n=8, Locator bar attachment: n=8). RESULTS. Marginal bone loss, probing depth, plaque index of the Locator bar attachment group were significantly lower than the Locator implant attachment group (P<.05). There was no significant difference on bleeding, peri-implant inflammation, and patient satisfaction between the two denture types (P>.05). The replacement of the attachment components was the most common complication in both groups. Although there was no correlation between marginal bone loss and plaque index, a significant correlation was found between marginal bone loss and probing depth. CONCLUSION. The Locator bar attachment group indicates lesser marginal bone loss and need for maintenance, as compared with the Locator implant attachment group. This may be due to the splinting effect among implants rather than the types of Locator attachment.

SCANNING ELECTRON MICROSCOPIC STUDY OF IMPLANT SURFACE AFTER Er,Cr:YSGG LASER IRRADIATION (Er,Cr:YSGG 레이저를 조사한 임플란트 표면의 주사전자현미경적 연구)

  • Jo, Pil-Kwy;Min, Seung-Ki;Kwon, Kyung-Hwan;Kim, Young-Jo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.5
    • /
    • pp.454-469
    • /
    • 2006
  • Today, there is considerable evidence to support a cause-effect relationship between microbial colonization and the pathogenesis of implant failures. The presence of bacteria on implant surfaces may result in an inflammation of the peri-implant mucosa, and, if left untreated, it may lead to a progressive destruction of alveolar bone supporting the implant, which has been named as peri-impantitis. Several maintenance regimens and treatment strategies for failing implants have been suggested. Recently, in addition to these conventional tools, the use of different laser systems has also been proposed for treatment of peri-implant infections. As lasers can perform excellent tissue ablation with high bactericidal and detoxification effects, they are expected to be one of the most promising new technical modalities for treatment of failing implants. It is introduced that Er,Cr:YSGG laser, operating at 2780nm, ablates tissue by a hydrokinetic process that prevents temperature rise. We studied the change of the titanium implant surface under scanning electron microscopy after using Er,Cr:YSGG laser at various energies, irradiation time. In this study, Er,Cr:YSGG laser irradiation of implant fixture showed different effects according to implant surface. Er,Cr:YSGG laser in TPS surface with RBM not alter the implant surface under power setting of 4 Watt(W) and irradiation time of 30sec. But in TPS surface with $Ca_3P$ coating alter above power setting of 2W and irradiation time of 10sec. TPS surface with RBM showed microfracture in 4W, 30sec and TPS surface with $Ca_3P$ coating showed destruction of fine crystalline structure, melting in excess of 2W, 10sec. We concluded that proper power setting, air, water of each implant surface must be investigated and implant surface must be irradiated under the damaged extent.

Guided bone regeneration using K-incision technique

  • Cho, Young-Dan;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.3
    • /
    • pp.193-200
    • /
    • 2018
  • Purpose: The present study describes 3 patients with chronic periodontitis and consequent vertical resorption of the alveolar ridge who were treated using implant-based restoration with guided bone regeneration (GBR). Methods: After extraction of a periodontally compromised tooth, vertical bone augmentation using a K-incision was performed at the healed, low-level alveolar ridge. Results: The partial-split K-incision enabled soft tissue elongation without any change in buccal vestibular depth, and provided sufficient keratinized gingival tissue during GBR. Conclusions: Within the limits of this study, the present case series demonstrated that the novel K-incision technique was effective for GBR and allowed normal implant-based restoration and maintenance of a healthy periodontal condition. However, further long-term follow-up and a large-scale randomized clinical investigation should be performed to evaluate the feasibility of this technique.

Novel design of implant prosthesis considering esthetics and periodontal maintenance: case report (심미성 및 치주 조직의 유지 관리를 고려한 임플란트 보철 증례)

  • Paek, Janghyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.70-76
    • /
    • 2014
  • After extraction of tooth, alveolar ridge resorption is inevitable in most cases. Clinicians confront with horizontal and vertical resorption of alveolar bone. Without massive amount of bone and soft tissue graft, dental implant will be placed apically to gain stability. In those cases, not only white esthetic part, but also pink esthetic part should be restored with pink porcelain. The margin of prosthesis should be located apically to reproduce natural look with adjacent teeth. However, when the margin is located apically, it is always hard to remove remaining cement, thus complications may arise. In this report, a novel design of implant prosthesis is introduced to solve those issues. The novel design is consisted of zirconia framework with pink porcelain and separate crowns on top of the framework. It eliminates the possibility of cement remnants by bringing the crown margin coronally. Pink esthetic part is incorporated in abutment part instead of crown part and the screw hole is covered with separate crowns.

Retrospective analysis of $frialit-2^{(R)}$ implant system placed in maxilla (상악에 식립된 Frialit-2 임플란트의 성공률에 대한 후향적 연구)

  • Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Shim, June-Sung;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.449-460
    • /
    • 2005
  • Objectives Aim of this study was to evaluate the clinical use and the efficacy of Frialit-2 implant system. Experimental Methods Fifty nine patients received placement of Frilalit-2 implants(137 implants) in their maxillary anterior and posterior sites(40 and 97 implants). Intraoral & clinical examination, chart review and radiographs were taken from each patient. Results 1. The total implant survival rate was 92.7% after a mean follow-up period of 19.9 months. 2. The implant survival rate placed in anterior region was 97.5%. 3. The implant survival rate placed in posterior region was 90.7%. 4. The implant survival rate placed in atrophic posterior maxilla with advanced technique (GBR, Sinus elevation) was 87.2%. 5. The implant survival rate placed in type N(D4) bone was 82%, while 95.7% in type III (D3), and 100% in type II(D2) bone. 6. Most of the failed implants(7 of 10) were removed during the maintenance stage after prosthodontic treatment. Conclusion It was concluded that Frialit-2 implant could be used satisfactorily in the esthetic anterior region, but the use in the posterior region, especially with poor bone quality and quantity, further studies are needed.

Acellular Dermal Matrix as a Core Strut for Projection in Nipple Reconstruction: Approaches for Three Different Methods of Breast Reconstruction

  • Park, Gui-Yong;Yoon, Eul-Sik;Cho, Hee-Eun;Lee, Byung-Il;Park, Seung-Ha
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.424-429
    • /
    • 2016
  • Background The objective of this paper was to describe a novel technique for improving the maintenance of nipple projection in primary nipple reconstruction by using acellular dermal matrix as a strut in one of three different configurations, according to the method of prior breast reconstruction. The struts were designed to best fill the different types of dead spaces in nipple reconstruction depending on the breast reconstruction method. Methods A total of 50 primary nipple reconstructions were performed between May 2012 and May 2015. The prior breast reconstruction methods were latissimus dorsi (LD) flap (28 cases), transverse rectus abdominis myocutaneous (TRAM) flap (10 cases), or tissue expander/implant (12 cases). The nipple reconstruction technique involved the use of local flaps, including the C-V flap or star flap. A $1{\times}2-cm$ acellular dermal matrix was placed into the core with O-, I-, and L-shaped struts for prior LD, TRAM, and expander/implant methods, respectively. The projection of the reconstructed nipple was measured at the time of surgery and at 3, 6, and 9 months postoperatively. Results The nine-month average maintenance of nipple projection was $73.0%{\pm}9.67%$ for the LD flap group using an O-strut, $72.0%{\pm}11.53%$ for the TRAM flap group using an I-strut, and $69.0%{\pm}10.82%$ for the tissue expander/implant group using an L-strut. There were no cases of infection, wound dehiscence, or flap necrosis. Conclusions The application of an acellular dermal matrix with a different kind of strut for each of 3 breast reconstruction methods is an effective addition to current techniques for improving the maintenance of long-term projection in primary nipple reconstruction.