Implant-assisted removable partial denture in a maxillary edentulous patient: A case report (상악 무치악 환자에서 전방부 임플란트 지지 고정성 보철물을 이용한 임플란트 보조 국소의치 수복 증례)

  • Kang, Hyun-Mo;Kim, Jee-Hwan;Kim, Jae-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.442-452
    • /
    • 2022
  • Implant-assisted removable partial denture (IAPRD) can be considered as a simple and cost-effective treatment approach for an edentulous patient with anatomical or financial limitations. Recently, it was reported that the application of IARPD with implant supported fixed prostheses covered by the National Health Insurance Service (NHIS) were increasing. This case report describes the treatment of maxillary fully edentulous patient with anterior four-implant-supported fixed prosthesis and distal extension IARPD. This treatment approach may be advantageous over maxillary implant overdentures in some circumstances. The patient was satisfied with improved function and esthetics in the anterior area and financial benefit from the NHIS. Further long-term clinical studies are needed to establish clinical validity of the treatment approach described in this case report.

Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique (구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례)

  • Hong, Yong-Shin;Park, Eun-Jin;Kim, Sun-Jong;Kim, Myung-Rae;Heo, Seong-Joo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. For the scope of implant prosthesis, however, digital intra-oral scan hasn't been actively utilized for the fabrication of superstructures. In this case report, 6 cases of titanium-milled custom abutment based on the iTero intra-oral scan data were introduced, five of them were restored with screw-type prosthesis after cementation (SCRP) and the clinical results were satisfactory on restoring the function and esthetics.

Comparative study on stress distribution around internal tapered connection implants according to fit of cement- and screw-retained prostheses

  • Lee, Mi-Young;Heo, Seong-Joo;Park, Eun-Jin;Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.312-318
    • /
    • 2013
  • PURPOSE. The aim of this study was to compare the passivity of implant superstructures by assessing the strain development around the internal tapered connection implants with strain gauges. MATERIALS AND METHODS. A polyurethane resin block in which two implants were embedded served as a measurement model. Two groups of implant restorations utilized cement-retained design and internal surface of the first group was adjusted until premature contact between the restoration and the abutment completely disappeared. In the second group, only nodules detectable to the naked eye were removed. The third group employed screw-retained design and specimens were generated by computer-aided design/computer-aided manufacturing system (n=10). Four strain gauges were fixed on the measurement model mesially and distally to the implants. The strains developed in each strain gauge were recorded during fixation of specimens. To compare the difference among groups, repeated measures 2-factor analysis was performed at a level of significance of ${\alpha}$=.05. RESULTS. The absolute strain values were measured to analyze the magnitude of strain. The mean absolute strain value ranged from 29.53 to 412.94 ${\mu}m/m$ at the different strain gauge locations. According to the result of overall comparison, the cement-retained prosthesis groups exhibited significant difference. No significant difference was detected between milled screw-retained prostheses group and cement-retained prosthesis groups. CONCLUSION. Within the limitations of the study, it was concluded that the cement-retained designs do not always exhibit lower levels of stress than screw-retained designs. The internal adjustment of a cement-retained implant restoration is essential to achieve passive fit.

Effect of open proximal contact on adjacent tooth and implant (개방된 인접면 접촉이 인접자연치와 임플란트에 미치는 영향)

  • Moon, Sohyun;Kim, Gwangyun;Cho, Seonghun;Song, Joohun;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • Purpose: The purpose of this study is to investigate how open contacts impact the natural teeth and dental implant prostheses. Materials and Methods: Following criteria were used to select 20 implant crowns with open proximal contacts as the experimental group (Group A): the restorations were delivered in Chosun University Dental Hospital between 2008 and 2018, the restorations are in the posterior region, opposing teeth are fixed dental prostheses, neighboring teeth are sound natural teeth, the patient had been on the maintenance program for at least 3 years. Another 20 implant crowns with closed proximal contacts were selected as the control group (Group B) using the same criteria. Between the two groups, dental caries and food impaction of the neighboring natural teeth and marginal bone-loss of the implants were compared and evaluated. Results: There was no statistically significant difference between Group A and Group B in the occurrence rates of dental caries, food impaction, and marginal bone-loss. The amount of marginal bone-loss, however, revealed statistically significant differences between the two groups, with Group A showing 0.80 ± 0.39 mm loss and Group B showing 1.1 ± 0.43 mm loss. Conclusion: Implant prostheses with open contacts could be clinically considered in select cases as such restorations revealed no harmful effects on neighboring teeth and implant restorations within the perimeters of this study.

Resin-bonded fixed partial denture using In-Ceram and Targis-Vectris system: A clinical report

  • Cha, Young-Joo;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.375-381
    • /
    • 2000
  • The conventional approach for replacing missing maxillary lateral incisors dictates the placement of either a conventional porcelain-fused-to-metal (PFM)bridge, resin-bonded fixed partial denture, or single implant prosthesis. However, several appearance-related disadvantages have been reported in the use of a prosthesis which incorporates a metal substructure. To address these limitations, metal -free restorative alternatives have been recently developed to expand the clinical options when fabrication of these prostheses is indicated. This clinical report describes the treatment of patients with a missing maxillary lateral incisor where the dentition was non-invasively restored with resin-bonded fixed partial denture(RBFPD) using In-Ceram and Targis-Vectris system.

  • PDF

A STUDY ON CYTOTOXICITY OF THE NEW TITANIUM ALLOYS FOR DENTAL IMPLANT MATERIAL (Dental Implant 금속재료의 성분차이에 따른 세포독성에 관한 연구)

  • Kim, Tae-In;Han, Jun-Hyun;Lee, In-Seok;Lee, Kyu-Hwan;Shin, Myung-Chul;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.675-686
    • /
    • 1996
  • Today, dental implants are an acceptable alternative, capable of providing bone-anchored fixed prostheses for improved quality of life and self esteem for many patients. Research advances in dental implantology have led to the development of several different types of materials, and it is anticipated that continued research will likewise lead to advanced dental implant materials. Currently used pure titanium has relatively low hardness and strength which possibly limits its ability to resist the functional loads as a dental implant. Ti-6Al-4V also has potential problems such as corrosion resistance, bone biocompatibility etc. The carefully selected Zr, Nb, Ta, Pd, In constituents could improve mechanical strength, corrosion resistance, and biocompatibility compared to that of currently used implant metals. On the basis of the totality of the data from our study, it can be concluded that new titanium alloys containing Zr, Nb, Ta, Pd, In are able to provide improved mechanical properties, corrosion resistance and biocompatibility to warrant further investigation of it's potential as new biomaterials for dental implants.

  • PDF

Clinical study on the comparison of gold and zirconia wear in an implant-supported fixed prosthesis (임플란트 지지 고정성 보철물에서 금과 지르코니아의 마모 비교에 대한 임상 연구)

  • Kim, Jee-Hwan;Yang, Seung-Won;Oh, NamSik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.252-259
    • /
    • 2017
  • Purpose: The purpose of this study was to compare and analyze the wear of a prosthesis for 6 months after restoration with implant-supported fixed dental prosthesis made of either zirconia or gold. Materials and Methods: This study was conducted on patients requiring implant-supported fixed dental prostheses on first or second molar from January, 2015 to January, 2016. A total of 47 prostheses and antagonists were examined. Occlusal surface was recorded by impression of each prosthesis and antagonist 1 week and 6 months after prosthesis delivery. The digital files were created by impression scan. Occlusal shapes of 1 week and 6 months were compared and wear of prostheses and antagonists was analyzed. The Mann-Whitney test was used to analyzed the result data underwent normality test using SPSS (Version 23.0, IBM Corporation) Results: Mann-Whitney test revealed that there was no statistically significant difference in the median amount of mean vertical wear for 6 months in zirconia ($50.84{\mu}m$) and gold ($42.84{\mu}m$) prostheses (P > 0.05). When the opposing teeth were natural, the median amount of mean vertical wear of zirconia and gold prostheses was $47.72{\mu}m$ and $41.97{\mu}m$, respectively, and the median amount of mean vertical wear of enamel was $47.26{\mu}m$ and $44.59{\mu}m$, respectively. Statistical analysis showed no significant difference (P > 0.05). Conclusion: Despite the short study period and the small number of experimental groups, zirconia and gold showed no significant difference in wear during the first 6 months. Opposing natural enamel also showed no significant difference in the wear.

Full mouth rehabilitation of mandibular edentulous patient using implant hybrid prosthesis (하악 무치악 환자에서 임플란트 하이브리드 보철물을 이용한 전악 수복 증례)

  • Kim, Seong-Bin;Kim, Sung-Hoi;Park, Young-Bum;Moon, Hong-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.214-220
    • /
    • 2013
  • Implant prosthodontics is beneficial for edentulous patients in enhancing the support, retention, stability, phonation and so on. Various types of prosthesis supported by implant, including implant retained- or supported- overdenture for the removable type and ceramo-metal and fixed prostheses with processed acrylic teeth for the fixed type, are frequently used. Treatment planning for the prosthesis with implant must be made after considering individual characteristics such as form of residual ridge, soft tissue, interocclusal relationship, economic status. Fixed prosthesis with processed acrylic teeth (also known as 'implant hybrid prosthesis' or 'bone anchored bridge') has the advantages of both removable and fixed prosthesis such as proper soft tissue profile, esthetic outcome, increased masticatory efficiency and psychological stability. The 73-years-old female patient came to the department of prosthodontics, Dental hospital of Yonsei University. She was diagnosed with Kennedy class I partial edentulism in the maxilla and complete edentulism in the mandible. This article reports a satisfactory clinical and esthetic outcome of full mouth rehabilitation using removable partial denture in the maxilla and implant hybrid prosthesis in the mandible.

Comparison of treatments for maxillary full denture and mandibular implant-supported fixed prosthesis in completely edentulous patients: A case report (완전 무치악 환자에서 상악 총의치와 하악 임플란트 지지 고정성 보철 치료를 위한 치료법 비교: 증례 보고)

  • Jin-Won Han;Se-Wook Pyo;Jae-Seung Chang;Sunjai Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.73-81
    • /
    • 2023
  • There are various approaches to treatment for patients with fully edentulous jaw. In maxilla, it is easy to obtain sufficient stability, support, and retention with the traditional full denture method. In mandible, however, there are difficulties caused by anatomical limitations. In this case, treatment with implants can be considered. If it is difficult to place implants in posterior area, a fixed complete denture can be considered, using 4 - 5 implants anterior to mental foramen. This approach has changed in many ways, such as surgical methods and materials used, over the years. This case report compares two approaches and their changes over time, especially in the cases of mandibular fixed prostheses using implants, paired with maxillary complete denture.

The Application of CAD/CAM in Dentistry (임상가를 위한 특집 1 - CAD/CAM 치과적 응용)

  • Choi, Ho-Sik;Moon, Ji-Eun;Kim, Sung-Hun
    • The Journal of the Korean dental association
    • /
    • v.50 no.3
    • /
    • pp.110-117
    • /
    • 2012
  • Dental computer-aided design (CAD) and computer-aided manufacturing (CAM) technology have rapidly progressed over the past 30 years. The technology, which can be used in the dental laboratory, the dental office and the form of production centers, has become more common in recent years. This technology is now applied to inlays, onlays, crowns, fixed partial dentures, removable partial denture frameworks, complete dentures, templates for implant installation, implant abutments, and even maxillofacial prostheses. Dentists and dental technicians, who want to use these techniques, should have certain basic knowledge about that. This article gives an overview of CAD/CAM technologies, histories and how it applies in prosthetic dentistry.