• 제목/요약/키워드: Implant Stability Quotient

검색결과 58건 처리시간 0.024초

The effect of various thread designs on the initial stability of taper implants

  • Park, Ju-Hee;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.19-25
    • /
    • 2009
  • STATEMENT OF PROBLEM. Primary stability at the time of implant placement is related to the level of primary bone contact. The level of bone contact with implant is affected by thread design, surgical procedure and bone quality, etc. PURPOSE. The aim of this study was to compare the initial stability of the various taper implants according to the thread designs, half of which were engaged to inferior cortical wall of type IV bone(Group 1) and the rest of which were not engaged to inferior cortical wall(Group 2) by measuring the implant stability quotient(ISQ) and the removal torque value(RTV). MATERIAL AND METHODS. In this study, 6 different implant fixtures with 10 mm length were installed. In order to simulate the sinus inferior wall of type IV bone, one side cortical bone of swine rib was removed. 6 different implants were installed in the same bone block following manufacturer s recommended procedures. Total 10 bone blocks were made for each group. The height of Group 1 bone block was 10 mm for engagement and that of group 2 was 13 mm. The initial stability was measured with ISQ value using Osstell $mentor^{(R)}$ and with removal torque using MGT50 torque gauge. RESULTS. In this study, we found the following results. 1. In Group 1 with fixtures engaged to the inferior cortical wall, there was no significant difference in RTV and ISQ value among the 6 types of implants. 2. In Group 2 with fixtures not engaged to the inferior cortical wall, there was significant difference in RTV and ISQ value among the 6 types of implants(P < .05). 3. There was significant difference in RTV and ISQ value according to whether fixtures were engaged to the inferior cortical wall or not(P < .05). 4. Under-drilling made RTV and ISQ value increase significantly in the NT implants which had lower RTV and ISQ value in Group 2(P < .05). CONCLUSIONS. Without being engaged to the inferior cortical wall fixtures had initial stability affected by implant types. Also in poor quality bone, under-drilling improved initial stability.

비글견의 하악골에 식립된 임플랜트에 대한 공진주파수와 조직계측분석의 비교 연구 (Comparison between Resonance Frequency and Histomorphometric Measurements of Mandibular Implants in Beagle Dogs)

  • 김우영;장경수;김창회;김영수
    • 구강회복응용과학지
    • /
    • 제19권4호
    • /
    • pp.291-296
    • /
    • 2003
  • The use of resonance frequency analysis (RFA) provides a possibility to clinically measure implant stability and osseointegration. The implant stability quotient (ISQ) value of RFA is well known that influenced by effective abutment length and stiffness of the implant in the surrounding tissues. Among these factors stiffness is not accurately defined histologically yet. And the purpose of this study was to find the histolgical relationship of RFA. 17 implants in 3 beagle dogs were used for this study. Among these implants 10 were survived for 7 months, 4 were survived for 3 months and 3 were immediate status after placement. Resonance frequency analyses were conducted and the dogs were sacrificed. Percentage of the bone to implant contact (BIC) in the interface, percentage of the mineralized bone (bone area) within the threads of the implant, and marginal bone level were measured under light microscopy. The correlation between resonance frequency and histomorphometric measurements were analysed and following results were obtained. 1. There was statistically significant correlation between ISQ value and BIC on healed implants. But ISQ value and BIC of all implants were not significantly correlated. (P<0.01) 2. Significant correlation between ISQ value and bone area was not found in this study. 3. There was statistically significant correlation between ISQ value and marginal bone level on all implants as well as on healed implants. (P<0.01).

성견에서 골형성단백질이 코팅된 임플란트가 치조골 증대에 미치는 영향 (Effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs)

  • 박찬경;김종은;신주희;류재준;허중보;신상완
    • 대한치과보철학회지
    • /
    • 제48권3호
    • /
    • pp.202-208
    • /
    • 2010
  • 연구 목적: 이 연구의 목적은 골형성단백질 (recombinant human Bone Morphogenetic Protein-2; rhBMP-2)이 코팅된 임플란트가 치조골 증대에 미치는 영향을 알아보는 것이다. 연구 재료 및 방법: 6마리의 비글견이 실험에 사용되었다. 6개의 8 mm 길이의 임플란트가 발치 후 6개월 이상의 충분한 치유기간이 경과한 비글견의 치조골에 5 mm 깊이로 식립되었다. 각각의 동물에 좌측과 우측의 악궁-분할형으로 임의추출하여 한쪽에는 1.5 ml/mg 농도의 rhBMP-2가 코팅된 임플란트를, 반대편에는 코팅되지 않은 대조군 임플란트를 식립하고 임플란트 주변 골에 round bur를 이용하여 피질골 천공을 시행하였다. 점막골막판막에 이완절개를 시행하여 판막을 접합시키고 봉합하여 임플란트가 피개되도록 하였다. 방사선 사진 촬영은 수술 직후 (기준치), 수술 4주후, 수술 8주 후에 시행하였다. 측정은 각 방사선 사진의 임플란트 덮개나사 최상방에서 변연골까지의 거리를 측정하여 골 형성량을 계산하였다. 수술 직후와 수술 8주 후에 임플란트 안정도 (Implant Stability Quotient value; ISQ value)를 측정하였다. 통계분석을 위해 SPSS software를 사용하여 Man-Whitney ranksum test와 Wilcoxon signed ranksum test를 시행하였다. 통계적 유의수준은P=.05를 기준으로 하였다. 결과: 골형성단백질이 코팅된 임플란트에서 수직 결손부 상방으로 약 0.6 mm의 골 형성이 관찰되었다. 대조군에서는 제한된 양의 골 형성 혹은 골 소실이 일어났다. 각 시기에 따른 실험군과 대조군간의 골 형성량에 유의한 차이가 있었다 (P<.05). ISQ value는 수술 직후에는 실험군과 대조군의 유의한 차이가 없었지만 수술 8주 후에는 실험군에서 대조군 보다 유의하게 높게 증가되었다 (P<.05). 결론: 골형성단백질이 코팅된 임플란트는 완전히 치유된 치조골에서 임상적으로 유의한 골 증대 효과가 있는 것으로 보인다.

상악결절과 다공성 골 미네랄의 복합이식을 통한 상악동 골이식술 (MAXILLARY SINUS AUGMENTATION WITH BOVINE BONE MINERAL(Bio-$Oss^{(R)}$) AND THE MAXILLARY TUBEROSITY)

  • 한기덕;정일혁;이은경;서제덕;송승일
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권4호
    • /
    • pp.391-396
    • /
    • 2007
  • The aim of this study was to evaluate implant stability placed in the maxillary sinus which was augmented with bovine bone mineral(Bio-$Oss^{(R)}$) mixed with autogenous bone from the maxillary tuberosity. Maxillary sinus floor augmentation with the mixture of bovine bone mineral and autogenous maxillary tuberosity bone was performed in 30 maxillary sinuses, and 68 implants were placed at the time of sinus graft. After 6 months of implant placement abutments were connected and implant stability quotient(ISQ) was measured by radio frequency analysis(RFA). In addition, bone level changes was evaluated by taking periapical radiograph. During surgical procedures, no complication was observed, and all patients healed uneventfully. At 6 months the implant showed stable ISQ values. The marginal bone level changes around the fixtures was stably maintained through out the follow up period. This study confirmed that maxillary sinus floor augmentation with mixture of bovine bone mineral and maxillary tuberosity bone could be reliable for bone regeneration in subantral space.

Randomized controlled clinical trial of 2 types of hydroxyapatite-coated implants on moderate periodontitis patients

  • Kim, Hyun-Suk;Yun, Pil-Young;Kim, Young-Kyun
    • Journal of Periodontal and Implant Science
    • /
    • 제46권5호
    • /
    • pp.337-349
    • /
    • 2016
  • Purpose: The aim of this study was to compare and analyze the peri-implant tissue conditions and prospective clinical outcomes associated with 2 types of hydroxyapatite (HA)-coated implants: (1) fully HA-coated implants and (2) partially HA-coated implants with resorbable blast medium on the coronal portion of the threads. Methods: Forty-four partially edentulous patients were randomly assigned to undergo the placement of 62 HA-coated implants, and were classified as the control group (partially HA-coated, n=30) and the test group (fully HA-coated, n=32). All patients had chronic periodontitis with moderate crestal bone loss around the edentulous area. The stability and clinical outcomes of the implants were evaluated using the primary and secondary implant stability quotient (ISQ), as well as radiographic, mobility, and peri-implant soft tissue assessments around the implants. The Wilcoxon signed-rank test and the Mann-Whitney test were used to evaluate differences between and within the 2 groups, with P values <0.05 considered to indicate statistical significance. Results: The fully HA-coated implants displayed good retention of crestal bone, and insignificant differences were found in annual marginal bone loss between the 2 types of HA-coated implants (P>0.05). No significant differences were found in the survival rate (group I, 100%; group II, 100%) or the success rate (group I, 93.3%; group II, 93.8%). The fully HA-coated implants also did not significantly increase the risk of peri-implantitis (P>0.05). Conclusions: The fully HA-coated implants did not lead to an increased risk of peri-implantitis and showed good retention of the crestal bone, as well as good survival and success rates. Our study suggests that fully HA-coated implants could become a reliable treatment alternative for edentulous posterior sites and are capable of providing good retention of the crestal bone.

처리 방법이 다른 표면이 임플랜트의 골유착 및 안정성에 미치는 영향 (THE EFFECT OF DIFFERENT SURFACE TREATMENT ON THE OSSEOINTEGRATION AND STABILITY OF IMPLANTS)

  • 양성욱;임헌송;조인호
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.606-616
    • /
    • 2006
  • Purpose: This experiment examined the effect of different surface treatment on the osseointegration and stability of implants. Material and methods: In this study, 40 each of machined, SLA and RBM implants, which are the most commonly used implants, were implanted into the tibia of 20 normal rabbits using $OsseoCare^{TM}$. The rabbits were sacrificed after 1 week, 4 weeks, 8 weeks and 12 weeks for implant stability analysis, removal torque analysis, histologic and histomorphometric analysis. Result : ISQ showed significant difference between Machined and RBM at first week and at 4 weeks. There was significant difference between Machined and both SLA and RBM(p<0.05) but after 8 weeks there were no significant difference between each group. In the removal torque, RBM showd significantly higher values than SLA and Machined surface at 1st week. At 4th and 12th week, there was significant difference between Machined and SLA, RBM(p<0.05). In the bone to implant contact variable, there was no significant difference between each surface treatment method. In the Machined surface group, there was no significant difference between each time interval. but in SLA group, there were significant differences between the 1st week and 12th week and in RBM group, there were significant differences between the 1st week and 8th, 12th week and between 4th and 12th week(p<0.05). The bone area showed significantly higher values in SLA and RBM compared to Machined surface 1st and 8th week and significantly higher values in SLA than Machined surface at the 4th week(p<0.05). Conclusion: The roughened surface of implants showed positive effect in the early stages of implantation and assisted in bone formation After the bone formation stage, there was no statistical difference between Machined and roughened surface groups. In dental implantation, where initial stability is critical to the success of implants, the use of roughened surface implants should assist in reducing the healing period after implantation.

Histological comparison of different compressive forces on particulate grafts during alveolar ridge preservation: a prospective proof-of-concept study

  • Lee, Sung-Jo;Kang, Dae-Young;Cho, In-Woo;Shin, Hyun-Seung;Shin, Seung-Il;Fischer, Kai R.;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제50권3호
    • /
    • pp.197-206
    • /
    • 2020
  • Purpose: The aim of this study was to determine the impact of different compressive forces on deproteinized bovine bone mineral (DBBM) particles covered by native bilayer collagen membrane (NBCM) during alveolar ridge preservation (ARP) in the molar area, and to identify any histomorphometric and clinical differences according to the compressive force applied. Methods: Sockets were filled with DBBM after tooth extraction, and different compressive forces (30 N and 5 N, respectively) were applied to the graft material in the test (30 N) and control (5 N) groups. The DBBM in both groups was covered with NBCM in a double-layered fashion. A crossed horizontal mattress suture (hidden X) was then made. A core biopsy was performed using a trephine bur without flap elevation at the implant placement site for histomorphometric evaluations after 4 months. The change of the marginal bone level was measured using radiography. Results: Twelve patients completed the study. The histomorphometric analysis demonstrated that the mean ratios of the areas of new bone, residual graft material, and soft tissue and the implant stability quotient did not differ significantly between the groups (P>0.05). However, the mean size of the residual graft material showed a significant intergroup difference (P<0.05). Conclusions: The application of 2 compressive forces (5 N, 30 N) on particulate DBBM grafts during open-healing ARP in the posterior area led to comparable new bone formation, implant feasibility and peri-implant bone level.

COMPARISON BETWEEN $TIUNITE^{TM}$ AND ANOTHER OXIDIZED IMPLANT USING THE RABBIT TIBIA MODEL

  • Yeo, In-Sung;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun;Yang, Jae-Ho
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.339-344
    • /
    • 2007
  • Statement of problem. Various anodic oxidation techniques can be applied to dental implant surfaces. But the condition for optimal anodized surfaces has not been described yet. Purpose. The purpose of this investigation was to compare an implant that was oxidized by another method with $TiUnite^{TM}$ through resonance frequency analysis and histomorphometry. Material and methods. Turned (control), $TiUnite^{TM}$ and another oxidized fixtures, which used $Ca^{2+}$ solution for anodic oxidation, were placed in the tibiae of 5 New Zealand White rabbits. The bone responses were evaluated and compared by consecutive resonance frequency analysis once a week for 6 weeks and histomorphometry after a healing period of 6 weeks. Results. At the first week, both oxidized implants showed significantly higher implant stability quotient (ISQ) values than the control. No significant differences in resonance frequency analysis were found between the two oxidized groups for 6 weeks. The means and standard deviations of bone-to-implant contact (BIC) ratios were $71.0{\pm}4.2$ for $TiUnite^{TM}$, $67.5{\pm}10.3$ for the $Ca^{2+}$-based oxidation fixture, $22.8{\pm}6.5$ for the control. Both oxidized implants were significantly superior in osseointegration to the turned one. There was, however, no statistically significant difference between the two oxidized implants. Conclusion. $TiUnite^{TM}$ and the $Ca^{2+}$-based oxidation fixture showed superior early bone response than the control with respect to resonance frequency analysis and histomorphometry. No significant differences between the oxidized groups, however, were found in this investigation using the rabbit tibia model.

Primary implant stability in a bone model simulating clinical situations for the posterior maxilla: an in vitro study

  • Han, Ho-Chyul;Lim, Hyun-Chang;Hong, Ji-Youn;Ahn, Su-Jin;Han, Ji-Young;Shin, Seung-Il;Chung, Jong-Hyuk;Herr, Yeek;Shin, Seung-Yun
    • Journal of Periodontal and Implant Science
    • /
    • 제46권4호
    • /
    • pp.254-265
    • /
    • 2016
  • Purpose: The aim of this study was to determine the influence of anatomical conditions on primary stability in the models simulating posterior maxilla. Methods: Polyurethane blocks were designed to simulate monocortical (M) and bicortical (B) conditions. Each condition had four subgroups measuring 3 mm (M3, B3), 5 mm (M5, B5), 8 mm (M8, B8), and 12 mm (M12, B12) in residual bone height (RBH). After implant placement, the implant stability quotient (ISQ), Periotest value (PTV), insertion torque (IT), and reverse torque (RT) were measured. Two-factor ANOVA (two cortical conditions${\times}$four RBHs) and additional analyses for simple main effects were performed. Results: A significant interaction between cortical condition and RBH was demonstrated for all methods measuring stability with two-factor ANOVA. In the analyses for simple main effects, ISQ and PTV were statistically higher in the bicortical groups than the corresponding monocortical groups, respectively. In the monocortical group, ISQ and PTV showed a statistically significant rise with increasing RBH. Measurements of IT and RT showed a similar tendency, measuring highest in the M3 group, followed by the M8, the M5, and the M12 groups. In the bicortical group, all variables showed a similar tendency, with different degrees of rise and decline. The B8 group showed the highest values, followed by the B12, the B5, and the B3 groups. The highest coefficient was demonstrated between ISQ and PTV. Conclusions: Primary stability was enhanced by the presence of bicortex and increased RBH, which may be better demonstrated by ISQ and PTV than by IT and RT.

골유착 재현 레진 모델에서 골 상태 및 임플란트 형태에 따른 임플란트 안정성에 관한 연구 (Implant stability evaluation according to the bone condition, fixture diameter and shape in the osseointegration simulated resin model)

  • 권택가;여인성;김성훈;한중석;이재봉;양재호
    • 대한치과보철학회지
    • /
    • 제49권2호
    • /
    • pp.128-137
    • /
    • 2011
  • 연구 목적: 자기공명주파수 분석, 페리오테스트, 풀림 토크는 임플란트의 안정성을 측정하기 위한 방법으로 알려져 있다. 이 방법들은 골 상태와 임플란트 형태에 영향을 받는다. 본 연구에서는 골유착이 재현된 아크릴 레진 실험 모델에서 임플란트가 결합된 골의 양을 변화하고 경부의 골 상실양이 증가하였을 경우, 자기공명주파수 분석, 페리오테스트, 풀림 토크 측정에 어떠한 영향을 주는지 알아보고 이들 상호간의 관계를 알아보고자 하였다. 연구 재료 및 방법: 골 유착을 재현하기 위하여 임플란트를 알루미늄 틀에 나사로 고정한 후 자가중합형 아크릴릭 레진의 가루와 용액을 틀 안에 부어서 중합을 시켰다. 임플란트와 결합된 레진의 두께를 조정하여 골 결합 두께를 각각 1, 3, 5, 10 mm인 경우로 재현하였다. 그 후 임플란트 주변 경부 골 상실 양이 1, 3, 5 mm인 경우를 재현하였다. 각각의 재현된 골 조건에서는 4 mm 직경의 직선형 임플란트, 같은 직경의 tapered 형 임플란트, 5 mm 직경의 tapered 형의 3가지 임플란트가 각각 5개씩 사용되었다. 모든 골 조건에서 자기공명주파수 분석과 페리오테스트 측정이 이루어졌으며 골 결합 두께 1, 3 mm 시편에서는 풀림 토크가 측정되었다. 결과: 골 결합 두께가 증가하거나 임플란트 직경이 증가할수록 통계적으로 유의하게 ISQ 값은 증가하였고, 페리오테스트 값은 감소하였다 (P<.001, P<.001). 임플란트 경부에 주위 골 상실 양이 커질수록 ISQ 값은 감소하였고, 페리오테스트 값은 증가하였다 (P<.001). ISQ 값과 페리오테스트 t값은 매우 강한 상관관계를 나타냈다 (r = -0.99, P<.001). ISQ값과 풀림토크는 약한 상관관계를 나타냈으며 (r = 0.52, P<.001), 페리오테스트 값과 풀림 토크도 약한 상관관계를 나타냈다 (r = -0.52, P<.001). 결론: 레진으로 재현한 골의 양이 증가할수록, 임플란트의 직경이 증가할수록, 경부의 골 상실양이 적을수록 임플란트 안정성이 증가함을 확인할 수 있었다. 또한 본 연구에서는 ISQ 값과 페리오테스트 값의 강한 상관관계를 밝힐 수 있었다.