• 제목/요약/키워드: Implant Patient

검색결과 990건 처리시간 0.023초

Upper eyelid platinum weight placement for the treatment of paralytic lagophthalmos: A new plane between the inner septum and the levator aponeurosis

  • Oh, Tae Suk;Min, Kyunghyun;Song, Sin Young;Choi, Jong Woo;Koh, Kyung Suk
    • Archives of Plastic Surgery
    • /
    • 제45권3호
    • /
    • pp.222-228
    • /
    • 2018
  • Background The most common surgical treatment for paralytic lagophthalmos is the placement of a weight implant in the upper eyelid; however, this technique confers the risks of implant visibility, implant extrusion, and entropion. In this study, we present a new technique of placing platinum weight implants between the levator aponeurosis and inner septum to decrease such complications. Methods A total of 37 patients with paralytic lagophthalmos were treated between March 2014 and January 2017 with platinum weight placement (mean follow-up, 520.1 days). After dissecting through the orbicularis oculi muscle, the tarsal plate and levator aponeurosis were exposed. The platinum weights (1.0-1.4 g) were fixed to the upper margin of the tarsal plate and placed underneath the orbital septum. Results Five patients could partially close their eye after surgery. The average distance between the upper eyelid and the lower eyelid when the eyes were closed was 1.12 mm. The rest of the patients were able to close their eye completely. Three patients patient developed allergic conjunctivitis after platinum weight insertion, which was managed with medication. None of the patients complained of discomfort in the upper eyelid after surgery. Visibility or extrusion of the implant were observed in three patients. Conclusions Postseptal weight placement is a safe and reproducible method in both primary and secondary upper eyelid surgery for patients with paralytic lagophthalmos. It is a feasible method for preventing implant visibility, implant exposure, and entropion. Moreover, platinum is a better implant material than gold because of its smaller size and greater thinness.

Proton pump inhibitor intake negatively affects the osseointegration of dental implants: a retrospective study

  • Altay, Mehmet Ali;Sindel, Alper;Ozalp, Oznur;Yildirimyan, Nelli;Kocabalkan, Burak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권3호
    • /
    • pp.135-140
    • /
    • 2019
  • Objectives: This study sought to investigate the association between the systemic intake of proton pump inhibitors (PPI) and the early failure of dental implants. Materials and Methods: A retrospective cohort study involving 1,918 dental implants in 592 patients (69 implants in 24 PPI users and 1,849 implants in 568 nonusers, respectively) was conducted. The effect of PPI intake on the osseointegration of dental implants was evaluated using patientand implant-level models. Results: Among 24 PPI users, two patients experienced implant failure, one of whom had three and the other of whom had one failed implant, respectively. Thus, the rate of failure for this population was 8.3%. Separately, 11 nonusers each experienced one implant failure, and the failure rate for these patients was 1.9%. Fisher's exact test revealed statistically significant differences between PPI users and nonusers at the implant level (P=0.002) but failed to show any significance at the patient level (P=0.094). The odds of implant failure were 4.60 times greater among PPI users versus nonusers. Dental implants that were placed in patients using PPIs were found to be 4.30 times more likely to fail prior to loading. Conclusion: The findings of this study suggest that PPI intake may be associated with an increased risk of early dental implant failure.

디지털 가이드 수술의 이해와 임상적 적용 (Need-to-knows about Digital Implant Surgery)

  • 백장현;권긍록;김형섭;배아란;노관태;홍성진;이현종
    • 대한치과의사협회지
    • /
    • 제56권11호
    • /
    • pp.631-640
    • /
    • 2018
  • Nowadays computer-guided "flapless" surgery for implant placement using templates is gaining popularity among clinicians and patients. The advantages of this surgical protocol are its minimally invasive nature, accuracy of implant placement, predictability, less post-surgical discomfort and reduced time required for definitive rehabilitation. Aim of this study is to describe the digital implant protocol, thanks to which is now possible to do a mini-invasive static guided implant surgery. This is possible thanks to a procedure named surface mapping based on the matching between numerous points on the surface of patient's dental casts and the corresponding anatomical surface points in the CBCT data. With some critical points and needing an adequate learning curve, this protocol allows to select the ideal implant position in depth, inclination and mesio-distal distance between natural teeth and or other implants enabling a very safe and predictable rehabilitation compared with conventional surgery. It represents a good tool for the best compromise between anatomy, function and aesthetic, able to guarantee better results in all clinical situations.

  • PDF

Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis

  • Magat, Guldane;Oncu, Elif;Ozcan, Sevgi;Orhan, Kaan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권1호
    • /
    • pp.41-49
    • /
    • 2022
  • Objectives: We compared changes in fractal dimension (FD) and grayscale value (GSV) of peri-implant alveolar bone on digital panoramic radiography (DPR) and cone-beam computed tomography (CBCT) immediately after implant surgery and 12 months postoperative. Materials and Methods: In this retrospective study, 16 patients who received posterior mandibular area dental implants with CBCT scans taken about 2 weeks after implantation and one year after implantation were analyzed. A region of interest was selected for each patient. FDs and GSVs were evaluated immediately after implant surgery and at 12-month follow-up to examine the functional loading of the implants. Results: There were no significant differences between DPR and CBCT measurements of FD values (P>0.05). No significant differences were observed between FD values and GSVs calculated after implant surgery and at the 12-month follow-up (P>0.05). GSVs were not correlated with FD values (P>0.05). Conclusion: The DPR and reconstructed panoramic CBCT images exhibit similar image quality for the assessment of FD. There were no changes in FD values or GSVs of the peri-implant trabecular bone structure at the 12-month postoperative evaluation of the functional loading of the implant in comparison to values immediately after implantation. GSVs representing bone mass do not align with FD values that predict bone microstructural parameters. Therefore, GSVs and FDs should be considered different parameters for assessing bone quality.

Total joint reconstruction using computer-assisted surgery with stock prostheses for a patient with bilateral TMJ ankylosis

  • Rhee, Seung-Hyun;Baek, Seung-Hak;Park, Sang-Hun;Kim, Jong-Cheol;Jeong, Chun-Gi;Choi, Jin-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.41.1-41.6
    • /
    • 2019
  • Backgrounds: The purpose of this study is to discuss the total joint reconstruction surgery for a patient with recurrent ankylosis in bilateral temporomandibular joints (TMJs) using three-dimensional (3D) virtual surgical planning, computer-aided manufacturing (CAD/CAM)-fabricated surgical guides, and stock TMJ prostheses. Case presentation: A 66-year-old female patient, who had a history of multiple TMJ surgeries, complained of severe difficulty in eating and trismus. The 3D virtual surgery was performed with a virtual surgery software (FACEGIDE, MegaGen implant, Daegu, South Korea). After confirmation of the location of the upper margin for resection of the root of the zygoma and the lower margin for resection of the ankylosed condyle, and the position of the fossa and condyle components of stock TMJ prosthesis (Biomet, Jacksonville, FL, USA), the surgical guides were fabricated with CAD/CAM technology. Under general anesthesia, osteotomy and placement of the stock TMJ prosthesis (Biomet) were carried out according to the surgical planning. At 2 months after the operation, the patient was able to open her mouth up to 30 mm without complication. Conclusion: For a patient who has recurrent ankylosis in bilateral TMJs, total joint reconstruction surgery using 3D virtual surgical planning, CAD/CAM-fabricated surgical guides, and stock TMJ prostheses may be an effective surgical treatment option.

변형 근치 유방절제술 후 Becker 확장형 보형물을 이용한 유방 재건술 (Breast Reconstruction after Modified Radical Mastectomy with Becker Permanent Tissue Expander)

  • 홍용택;윤을식;최규진;동은상;손길수
    • Archives of Plastic Surgery
    • /
    • 제34권2호
    • /
    • pp.222-228
    • /
    • 2007
  • Purpose: Report of the good results of breast reconstruction using Becker permanent tissue expander that showed a short operation time and a quick post-operation recovery time, little side effects and usually superb aesthetic results without the need for additional incisions or donor site morbidity. The authors, after carrying out breast reconstruction operations using Becker permanent tissue expander on patients with appropriate indications, attempted to analyze several factors such as complication rates and patient satisfaction measurements. Methods: 11 cases of breast reconstruction using Becker expander implants were carried out on a total of 10 patients between March 2000 and February 2003. The patients were followed up at outpatient visit for an average of 6 months. Results: The most common post-operation complication was pain resulting from saline injection into the expanders, complained by 5 patients(50%). rib fractures, skin necrosis, implant removal due to infection, and breast cancer recurrence each occurred in 1 patient (9.9%). There was no occurrence of skin contracture complications which occurs frequently in case of silicone implant insertion. Patient complacency was surveyed by patient interviews made right after the operations and during outpatient follow-up periods: 5(50%) patients out of 10 showed excellent, 3(30%) good, and 2(20%) showed fair, leaving no patients who were disappointed with operation results. On routine follow-up, 80% of patients expressed satisfaction with the cosmetic outcome of their post-mastectomy beast reconstruction. Conclusion: Breast reconstruction using the Becker expander is a reliable alternative to other reconstructive methods but good patient selection is essential for satisfactory results.

임플란트 장기간 유지와 변연골 소실에 영향을 주는 요인들에 대한 후향적 연구 (The risk factors for implant survival and marginal bone loss: a retrospective long-term study)

  • 이은우;정하나;조유진;김옥수
    • 구강회복응용과학지
    • /
    • 제38권2호
    • /
    • pp.97-109
    • /
    • 2022
  • 목적: 3년 이상 기능한 임플란트의 장기 추적을 통해 임플란트 실패에 기여하는 위험지표를 조사하고 변연골소실(MBL)간의 상관관계를 분석하는 것이다. 연구 재료 및 방법: 2003년부터 2017년까지 전남대학교 치과병원에서 임플란트 수술 기왕력이 있는 환자의 진료기록부를 토대로 후향적 조사 시행하였다. 환자의 인구통계학적 변수 및 임상적 변수와 임플란트 주위 변연골소실 평가를 위한 치근단 방사선 사진을 사용하여 임플란트 생존율을 분석하였다. 환자의 임상변수와 임플란트 실패의 상관관계를 규명하기 위해 후진소거법을 이용한 다중회귀분석 시행하였고, 임플란트 장기생존율과 MBL 및 초기 안정성 간의 상관관계를 규명하기위해 Pearson 상관분석 시행하였다. 결과: 다중회귀분석 결과 지대주 연결 유형(β = -.189, P < .05), SPT 유무(β = -.163, P < .05), 당뇨(β = -.164, P < .05), 골수염(β = -.211, P < .05)이 MBL과 음의 상관관계가 있었다. 임플란트 장기 성공률에 항응고제, 임플란트 2차수술 시 PTV값이 영향을 미쳤다. 결론: 임플란트 장기 성공을 위해서는 적절한 지대주 연결 유형을 선택해야 하며, 주기적 SPT가 필요하다. 당뇨병, 골다공증 같은 전신 질환과 항응고제 사용 질환을 고려해야한다. 또한 임플란트 2차 수술시 높은 PTV가 임플란트 장기 생존율과 상관관계가 있기 때문에 보철 수복 전 초기 안정성을 신중히 고려해야한다.

Humeral intramedullary nail bending following trauma: a case report

  • Siem A. Willems;Alexander P. A. Greeven
    • Journal of Trauma and Injury
    • /
    • 제36권1호
    • /
    • pp.65-69
    • /
    • 2023
  • The surgical approach for humeral implant failure can be challenging due to neurovascular anatomy and the possible necessity of osteosynthesis removal. We present a rare case of humeral nail bending after secondary trauma in a patient with preexistent nonunion of the humerus after intramedullary nailing. During revision surgery, the nail was sawed in half and the distal part was removed, followed by plate osteosynthesis with cable fixation to achieve absolute stability. The patient regained a full range of motion 1 year after surgery, and complete healing of the fracture was seen on imaging.

Immediate loading on mandibular edentulous patient with SFI Bar$^{(R)}$ overdenture

  • Kim, Ha-Young;Kim, Jin-Young-Ryan;Qadeer, Sarah;Jeong, Chang-Mo;Shin, Sang-Wan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권1호
    • /
    • pp.47-50
    • /
    • 2011
  • Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar$^{(R)}$ (Cendres et Me$\'{e}$taux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.

Evaluation of dental panoramic radiographic findings in edentulous jaws: A retrospective study of 743 patients "Radiographic features in edentulous jaws"

  • Kose, Taha Emre;Demirtas, Nihat;Karabas, Hulya Cakir;Ozcan, Ilknur
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.380-385
    • /
    • 2015
  • PURPOSE. The aim of this study was to determine the frequency of significant panoramic radiographic findings and eventual treatment requirements before conventional or implant supported prosthetic treatment in asymptomatic edentulous patients. MATERIALS AND METHODS. A total of 743 asymptomatic edentulous patients were retrospectively evaluated using a digital panoramic system. We analyzed the radiographic findings, including impacted teeth, retained root fragments, foreign bodies, severe atrophy of the posterior maxillary alveolar bone, mucous retention cysts, soft tissue calcifications and radiopaque-radiolucent conditions. RESULTS. Four-hundred-eighty-seven (65.6%) patients had no radiographic finding. A total of 331 radiographic findings were detected in 256 (34%) patients. In 52.9% (n=175) of these conditions, surgical treatment was required before application of implant-supported fixed prosthesis. However, before application of conventional removable prosthesis surgical treatment was required for 6% (n=20) of these conditions. CONCLUSION. The edentulous patients who will have implant placement for implant-supported fixed prosthesis can frequently require additional surgical procedures to eliminate pathological conditions.