• Title/Summary/Keyword: Implant Patient

Search Result 990, Processing Time 0.026 seconds

MR Findings of Breast Implant Rupture Presenting with Unusual Breast Enlargement

  • Park, So Yeon;Woo, Ok Hee;Dhong, Eun Sang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.110-112
    • /
    • 2018
  • We report the case of a patient who presented with rupture of a silicone breast implant showing acute and chronic inflammation. Magnetic resonance imaging (MRI) showed silicone foci outside the implant shell and inside the pectoralis muscles that represented intra- and extracapsular ruptures of the implant and silicone granuloma. There were distinct fluid-fluid levels of various signal intensities and no signs of implant collapse such as 'linguine sign.' Rather, we detected enlargement of both the implant shell and the breast.

Prosthetic restorations with cementless screw-retained implant systems: a case report (시멘트리스 나사 유지형 임플란트 시스템을 이용한 보철물 수복 증례)

  • Young-hae Jung;Im-Sun Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.4
    • /
    • pp.124-130
    • /
    • 2023
  • This study aims to describe the clinical experience of single and bridge crowns fabricated using a cementless screw-retained implant prosthesis system. In the case of single crown (#37), regular link (HDL) was used, and bridge crowns (#15~#24), (#26~#27), (#17~#14) (#24~#26) were fabricated by selecting regular link and short link considering the vertical height. One abutment was hex shaped to ensure that it could be mounted while preventing insertion and prosthesis rotation. The advantages of cementless implant prosthesis include shorter chair time and periodic care, strong retention with LINK abutment, safety from inflammation, bacterial infection, and complications due to peri-implant cement, and high patient satisfaction. Dentists should double-check the position of the implant fixture and dental technicians should continuously manage the fit of the link and prosthesis with digital equipment to reduce screw loosening and fractures.

Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction

  • Pereira, Ana Larisse Carneiro;Medeiros, Vitoria Ramos;Campos, Maria de Fatima Trindade Pinto;Medeiros, Annie Karoline Bezerra de;Yilmaz, Burak;Carreiro, Adriana da Fonte Porto
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.212-222
    • /
    • 2022
  • PURPOSE. To evaluate and compare the effect of impression type (conventional vs digital) and the number of implants on the time from the impressions to the generation of working casts of mandibular implant-supported fixed completearch frameworks, as well as on patient satisfaction. MATERIALS AND METHODS. 17 participants, 3 or 4 implants, received 2 types of digital impression methods (DI) and conventional (CI). In DI, two techniques were performed: scanning with the scan bodies (SC) and scanning with a device attached to the scan bodies (SD) (BR 10 2019 026265 6). In CI, the making of a solid index (SI) and open-tray impression (OT) were used. The outcomes were used to evaluate the time and the participant satisfaction with conventional and digital impressions. The time was evaluated through the timing of the time obtained in the workflow in the conventional and digital impression. The effect of the number of implants on time was also assessed. Satisfaction was assessed through a questionnaire based on seven. The Wilcoxon test used to identify the statistical difference between the groups in terms of time. The Mann-Whitney test was used to analyze the relationship between the time and the number of implants. Fisher's test was used to assess the patient satisfaction (P<.05). RESULTS. The time with DI was shorter than with CI (DI, $\tilde{x}=02:58$; CI, $\tilde{x}=31:48$) (P<.0001). The arches rehabilitated with 3 implants required shorter digital impression time (3: $\tilde{x}=05:36$; 4: $\tilde{x}=09:16$) (P<.0001). Regarding satisfaction, the DI was more comfortable and pain-free than the CI (P<.005). CONCLUSION. Digital impressions required shorter chair time and had higher patient acceptance than conventional impressions.

Evaluation of prognosis related to compliance with supportive periodontal treatment in patients with chronic periodontitis: a clinical retrospective study

  • Lee, Jong-Bin;Shin, Hye-Jung;Kim, Dae-Yeob;Pang, Eun-Kyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.2
    • /
    • pp.76-89
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the prognostic effect of patient compliance with supportive periodontal treatment (PC-SPT). Chronic periodontitis patients were classified based on their compliance level, and factors affecting PC-SPT and the prognosis of PC-SPT were investigated. Methods: This study selected 206 patients who started SPT after receiving periodontal treatment between 2010 and 2012. Patients who continued SPT through February 2016 were included. The patients were classified according to whether they exhibited complete compliance (100% of visits), excellent compliance (${\geq}70%$ of visits), incomplete compliance (<70% of visits), or non-compliance (only 2 visits). Patient characteristics that could affect PC-SPT, such as age, sex, distance of the clinic from their residence, implantation, and periodontal treatment, were investigated. The number of newly decayed and extracted teeth, alveolar bone level changes around the teeth and implants, and implant removal were examined to evaluate the prognosis of PC-SPT. Results: Sex and the presence of an implant significantly affected PC-SPT. Additionally, the number of newly decayed and extracted teeth and changes in alveolar bone levels around the teeth and implants were significant prognostic factors related to PC-SPT. Conclusions: PC-SPT in chronic periodontitis patients will help maintain periodontal health and prevent further periodontal disease.

An implant-supported removable partial denture for a patient with post-inflammatory scar contracture caused by burn complications: a clinical report

  • Kim, Jee-Hwan;Lee, Jae-Hoon
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.1
    • /
    • pp.57-59
    • /
    • 2012
  • The scars and contracture around the oral-facial region may cause difficulty in prosthodontic treatment to restore esthetics and function for the patients, who suffered severe burns. This article presents a technique that uses a fixed partial denture prepared with a conventional milling technique and an attachment to support anterior cantilever removable partial denture, thereby providing a more esthetically acceptable and functional result.

THE PREVALENCE OF SENSORY DISTURBANCE AFTER IMPLANT SURGERY - RETROSPECTIVE SURVEY OF IMPLANT PRACTITIONERS (임플란트 식립후 하악 신경손상에 대한 후향적 연구)

  • Kwon, Tae-Geon;Kim, Shin-Yu;Kim, Jong-Bae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.339-344
    • /
    • 2004
  • The purpose of this study was to evaluate neurosensory disturbance associated with implant surgery performed by implant practitioner (n=47) composed of trained oral surgeon, periodontist, prosthodontist. The incidence, type and duration of sensory disorder were investigated. Anatomical factor of the patient and experience of operator were also evaluated. The result revealed high incidence of inferior alveolar nerve damage (45%) regardless of experience of implant practitioner. The sensory disturbance sustained within 6 months for 61% of cases, which revealed almost normal recovery of nerve function. Initial neurologic sign after nerve damage was not coincide with their consequence of recovery. Half of the practitioners tried surgical intervention to the implants such as removing the fixture, partial unscrewing or re-implant shorter fixture, of which trial regarded as effective measure for 53% of cases. The result indicates that the objective method of sensory nerve evaluation should be introduced to the implant practitioners and the importance of informed consent for possibility of nerve damage in mandibular implant fixation.

Simultaneous Hard Tissue and Soft Tissue Graft with Dental Implant Placement and Provisionalization: A Case Report

  • Hyunjae Kim;Young-Dan Cho;Sungtae Kim
    • Journal of Korean Dental Science
    • /
    • v.17 no.2
    • /
    • pp.84-91
    • /
    • 2024
  • Achieving both esthetic and functional implant rehabilitation is crucial for the successful treatment of the anterior maxilla. Adequate peri-implant alveolar bone and soft tissue are essential for optimal rehabilitation of the esthetic area, and there is a direct association between the implant position and prosthetic outcomes. Immediate provisionalization may also be advantageous when combined with augmentation. This case report described the implant placement in a 25-year-old female patient who had lost her right maxillary lateral incisor (#12) due to trauma-induced avulsion. The treatment involved simultaneous grafting and collagenated, deproteinized bovine bone mineral, along with subepithelial connective tissue taken from the right maxillary tuberosity. A polyetheretherketone abutment and non-functional immediate provisionalization were performed by removing both the proximal and occlusal contacts on the composite resin crown. Clinical and radiographic evaluations revealed maintenance of stable ridge contour aspects for six months following surgical treatment. In summary, implant rehabilitation in the esthetic zone can be successful using simultaneous soft and hard tissue grafts. Moreover, soft tissue stabilization post-subepithelial connective tissue grafting can be achieved through early or immediate visualization, along with immediate implant placement.

Extracting 3D Geometry Parameters of Hip Joint for Designing a Custom-Made Hip Implant (맞춤형 인공관절 설계를 위한 인체 고관절의 3차원 형상 정보 추출)

  • Seo, Jeong-Woo;Jun, Yong-Tae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.3
    • /
    • pp.200-208
    • /
    • 2008
  • Total Hip Replacement(THR) is a surgical procedure that replaces a diseased hip joint with a prosthesis. A plastic or metal cup forms the socket, and the head of the femur is replaced by a metal ball on a stem placed inside the femur. Due to the various types and shapes of human hip joint of every individual, a selected commercial implant sometimes may not be the best-fit to a patient, or it cannot be applied because of its discrepancy. Hence extracting geometry parameters of hip joint is one of the most crucial processes in designing custom-made implants. This paper describes the framework of a methodology to extract the geometric parameters of the hip joint. The parameters include anatomical axis, femoral head, head offset length, femoral neck, neck shaft angle, anteversion, acetabulum, and canal flare index. The proposed system automatically recommends the size and shape of a custom-made hip implant with respect to the patient's individual anatomy from 3D models of hip structures. The proposed procedure creating these custom-made implants with some typical examples is precisely presented and discussed in this paper.

Naturalization of Implant Prostheses (자연감 있는 임플란트 보철물)

  • Kim, Dae-Hyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.96-103
    • /
    • 1999
  • Restoration of missing oral tissues by using implant therapy is one of viable options in prosthodontic treatment. The purpose of oral rehabilitation are function, esthetics and phonetics. Recently, with the increasing esthetic demand of the patient, dentists and laboratory technicians are more concern ed about natural appearance of implant prostheses. There are so many factors which affect final esthetic results of treatment such a shape, color, proportion, gingival contour etc. To provide natural and vivid looking artificial prostheses to a patient, the careful diagnosis, treatment plan and laboratory Support is crucial. Several cases will be reviewed and discussed in terms of material, gingival shape, contour, speech and connection mode etc. to fabricate natural looking implant prostheses.

  • PDF

Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure: A clinical case report

  • Agustin-Panadero, Ruben;Penarrocha-Oltra, David;Gomar-Vercher, Sonia;Ferreiroa, Alberto;Penarrocha-Diago, Miguel
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.264-270
    • /
    • 2015
  • This report describes the case of an edentulous patient with an atrophic maxilla and severe class III malocclusion. Prosthetic rehabilitation was performed using CAD/CAM techniques for manufacturing an implant-supported overdenture with horizontal insertion. A vestibulo-lingual insertion overdenture is a precision prosthesis with a fixation system affording a good fit between the primary and secondary structure. Both structures exhibit passive horizontal adjustment. This treatment option requires the same number of implants as implant-supported fixed dentures. The horizontal assembly system prevents the prosthesis from loosening or moving in response to axial and non-axial forces. The technique was used to rehabilitate a patient presenting an atrophic upper maxilla, with the insertion of 8 implants. No complications were reported at follow-up 3, 6 and 12 months after fitting of the prosthesis. This system offers solutions to the clinical and laboratory complications associated with hybrid prostheses, concealing emergence of the chimneys and improving implant-prosthesis hygiene.