• 제목/요약/키워드: Impingement baffle plate

검색결과 8건 처리시간 0.028초

유동가속부식으로 인한 급수가열기 동체 감육현상 규명과 완화 방안 및 충격판 설계개선에 관한 연구 (A Study on the Shell Wall Thinning by Flow Acceleration Corrosion and Mitigation Plan and Design Modification of a Feedwater Heater Impingement Baffle)

  • 김경훈;황경모;김인태
    • 한국분무공학회지
    • /
    • 제15권2호
    • /
    • pp.83-93
    • /
    • 2010
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle inside feedwater heater installed downstream of the turbine extraction stream line. At that point, the extract steam from the turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows to reverse direction after impinging the impingement baffle, the shell wall of feedwater heaters may be affected by flow-accelerated corrosion. In this paper, to compare degree of shell wall thinning mitigation rate to squared type with mitigation rate of other type baffle plate, four different types of impingement baffle plate-squared, curved, mitigating type and multi-hole type-applied inside the shell. With these comparison data, this paper describes operation of experiments and numerical analysis which is composed similar condition with real feed water heater. And flow visualization is operated for verification of experiments and numerical analysis. In conclusion, this study shows that mitigating type and multi-hole type baffle plate are more effective than other baffle plate about prevention of pressure concentration and pressure value decrease.

급수가열기 동체 감육 현상과 완화 방안 및 충격판 설계개선 (Shell Wall Thinning and Mitigation Plan and Design Modification of a Feedwater Heater Impingement Baffle)

  • 김경훈;황경모;박상훈
    • 한국정밀공학회지
    • /
    • 제27권6호
    • /
    • pp.55-63
    • /
    • 2010
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle inside feedwater heater installed downstream of the turbine extraction stream line. At that point, the extract steam from the turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows to reverse direction after impinging the impingement baffle, the shell wall of feedwater heaters may be affected by flow-accelerated corrosion. In this paper, to compare degree of shell wall thinning mitigation rate to squared type with mitigation rate of other type baffle plate, three different types of impingement baffle plate-squared, curved and mitigating type-applied inside the shell. With these comparison data, this paper describes operation of experiments and numerical analysis which is composed similar condition with real feed water heater. And flow visualization is operated for verification of experiments and numerical analysis. In conclusion, this study shows that mitigating type baffle plate is more effective than other baffle plate about prevention of pressure concentration and pressure value decrease.

급수가열기 추기노즐 충격판 주변의 동체감육 현상의 완화를 위한 실험 및 수치해석적 연구 (Experimental and Numerical Analysis in the Surroundings of Impingement Baffle Plate of the Extracting Nozzle for Disclosing Shell Wall Thinning of a Feedwater Heater)

  • 정선희;김경훈;황경모;송석윤
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.821-830
    • /
    • 2007
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed downstream of the high pressure turbine extraction steam line- inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes the comparisons between the numerical results using the FLUENT code and the down scale experimental data on effect of geometry of the impingement baffle plate on the shell wall thinning. Additionally, a new type impingement baffle plate was installed above the impingement baffle plate in the feedwater heater and then the numerical and experimental study were performed in the same progress.

추기노즐 충격판 주변의 급수가열기 동체 감육에 대한 유동해석 (A Flow Analysis in the surroundings of the Impingement Baffle of the Extracting Nozzle for Shell Wall Thinning of a Feedwater Heater)

  • 정선희;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2977-2982
    • /
    • 2007
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle - installed downstream of the high pressure turbine extraction steam line - inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes the comparisons between the numerical analysis results using the FLUENT code and the down scale experimental data which effect on disclosing of the shell wall thinning of the high pressure feedwater heaters by porous plate.

  • PDF

수직평판에 충돌하는 펄스파에 관한 실험적/수치해석적 연구 (Experimental and Computational Studies of the Pulse Wave Impinging upon a Vertical Flat Plate)

  • 이동훈;김희동;강성황
    • 소음진동
    • /
    • 제11권2호
    • /
    • pp.285-291
    • /
    • 2001
  • The impingement of a weak shock wane discharged from the open end of a shock tube upon a flat plate was investigated using shock tube experiments and numerical simulations. Harten-Yee Total Variation Diminishing method was used to solve axisymmetric, unsteady, compressible flow governing equations. Experiments were carried out to validate the present computations. The effects of the flat plate and baffle plate sizes on the impinging flow field over the flat plate were investigated. Shock Mach number was varied in the range from 1.05 to 1.20. The distance between the plate and shock tube was changed to investigate the effect on the peak pressure. From both the results of experiments and computations we obtained a good empirical equation to predict the peak pressure on the flat plate.

  • PDF

평판에 충돌하는 펄스파의 특성에 관한 연구 (A Study on the Characteristics of the Pulse Wave Impinging upon a Flat Plate)

  • 김희동;이동훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.562-567
    • /
    • 2000
  • The Impingement of a weak shock wave discharged from the open end of a shock tube upon a flat plate was investigated using shock tube experiments and numerical simulations. Harten-Yee Total Variation Diminishing method was used to solve axisymmetric, unsteady, compressible flow governing equations. Experiments were carried out to validate the present computations. The effects of the flat plate and baffle plate sizes on the impinging flow field over the flat plate were investigated. Shock Mach number was vaned in the range from 1.05 to 1.20. The distance between the plate and shock tube was changed to investigate the effect on the peak pressure. From both the results of experiments and computations we obtained a good empirical equation to predict the peak pressure on the flat plate.

  • PDF

와이어 스크린 배플이 설치된 채널에서의 열전달 특성 (The Characteristics of Heat Transfer in a Channel with Wire-screen Baffles)

  • 김원철;아리바시아크리시나부트라;안수환;강호근
    • 동력기계공학회지
    • /
    • 제13권2호
    • /
    • pp.11-17
    • /
    • 2009
  • The heat transfer characteristics of flow through two inclined wire-mesh baffles in a rectangular channel were investigated experimentally with varying the mesh number of wire screens and inclination angle of the baffles. Two different types of wire meshes such as dutch and plain weaves, were used in this experiment. Three kinds of baffle plates with different mesh specifications in the dutch weave and four different kinds in the plain weave were manufactured. Baffles were mounted on bottom wall with varied angles of inclination. Reynolds number was varied from 23,000 to 57,000. It is found that the placement of inclined wire-mesh baffles in the channel affects the heat transfer characteristics by combining both jet impingement and flow disturbance. The wire screen modified the flow structure leading to a change in the heat transfer characteristics. The results show that the baffle plate with the most number of mesh (type SA) has the highest heat transfer rate.

  • PDF

급수가열기 동체 감육 현상 규명을 위한 유동해석 연구 (A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater)

  • 신민호;황경모;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2017-2022
    • /
    • 2004
  • There are multistage preheaters in the power generation plan to improve the thermal efficiency of the plant and to prevent the components from the thermal shock. The energy source of these heaters comes from the extracted two phase fluid of working system. These two-phase fluid can cause the so-called Flow Accelerated Corrosion(FAC) in the extracting piping and the bubble plate of the heater for example, in case of point Beach Nuclear Power Plant and in the Wolsung Nuclear Power Plant. The FAC is due to the mass transport of the thin oxide layer by the convection. FAC is dependent on many parameters such as the operation temperature, void fraction, the fluid velocity and pH of fluid and so on. Therefore, in this paper velocity was calculated by FLUENT code in order to find out the root cause of the wall thinning of the feedwater heaters. It also includeed in the fluid mixing analysis model are around the number 5A feedwater heater shell including the extraction pipeline. To identify the relation between the local velocities and wall thinning, the local velocities according to the analysis results were compared with distribution of the shell wall thicknes by ultrasonic test.

  • PDF