• Title/Summary/Keyword: Impedance-based Analysis

Search Result 414, Processing Time 0.024 seconds

Application of Fault Current Limiter in 22.9kV KEPCO power distribution line (22.9kV 지중선로용 한류기 한전 실계통 시범적용)

  • Kim, Min Jee;Park, Kyungwon;Ahn, Kil-Young;Kim, Young-keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1034-1035
    • /
    • 2015
  • Watertight 25.8 kV/600 A/12.5 kA fault current limiters (FCLs) have successfully installed in five areas (Incheon, Seoul, Gyeong-gi, Daejeon, Suwon) on KEPCO power distribution line for the purpose of commercial demonstrations. The fault current limiting operation of this FCL, which includes functions of sensing, commutation, and reduction of fault currents, is perfectly completed within 1 cycle immediately after fault occurs. The performance of FCL was verified by short circuit test, impedance test, insulation test, temperature-rise test, and control test, etc at PT&T in LS industrial systems, which is the official certification institute in Korea. In 2013, and also the FCL field test was performed in order to test the protection coordination between conventional relays and FCL, on the 1.5 kA and 5.0 kA faults, which were made by connecting the Artificial Fault Generator (AFG) to the distribution line in test grid at KEPCO Power Testing Center. The next step of this project is to check the FCL conditions caused by real external environment, and acquire the various data from five regions installed with FCL. In this paper, we intend to explain the FCL specifications and performance characteristics, and check the expected effect by application of FCL to power distribution line based on the power system analysis of an application site.

  • PDF

Effect of Sintering Temperature on Dielectric Properties of 72 wt%(Al2O3):28 wt%(SiO2) Ceramics

  • Sahu, Manisha;Panigrahi, Basanta Kumar;Kim, Hoe Joon;Deepti, PL;Hajra, Sugato;Mohanta, Kalyani
    • Korean Journal of Materials Research
    • /
    • v.30 no.10
    • /
    • pp.495-501
    • /
    • 2020
  • The various sintered samples comprising of 72 wt% (Al2O3) : 28 wt% (SiO2) based ceramics were fabricated using a colloidal processing route. The phase analysis of the ceramics was performed using an X-ray diffractometer (XRD) at room temperature confirming the presence of Al2O5Si and Al5.33Si0.67O9.33. The surface morphology of the fracture surface of the different sintered samples having different sizes of grain distribution. The resistive and capacitive properties of the three different sintered samples at frequency sweep (1 kHz to 1 MHz). The contribution of grain and the non-Debye relaxation process is seen for various sintered samples in the Nyquist plot. The ferroelectric loop of the various sintered sample shows a slim shape giving rise to low remnant polarization. The excitation performance of the sample at a constant electric signal has been examined utilizing a designed electrical circuit. The above result suggests that the prepared lead-free ceramic can act as a base for designing of dielectric capacitors or resonators.

Analysis and fabrication of a wearable antenna using conductive fibers (전도성 실 재질을 이용한 웨어러블 안테나의 제작 및 분석)

  • Nguyen, Tien Manh;Chung, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2770-2776
    • /
    • 2015
  • The development of efficient wearable antennas is required to implement short range body-centric wireless communication links for various internet of thing applications. We present simulation and measurement results of conductive-fiber-based wearable antennas which can comfortably fabricated directly on usual clothing materials. The proposed antenna is a form of a rectangular patch antenna designed by weaving conductive fibers on a felt substrate. A full-wave electromagnetic simulation tool is used to investigate the antenna performance such as antenna impedance, resonant frequency, and radiation efficiency. Parametric studies show that the radiation efficiency increases from 67.5% to 70.4% by widening the gap between conductive fibers from 0.25mm to 3mm. This implies a wearable antenna with good radiation efficiency can be designed despite of less portion of conductive fibers on the antenna. The simulation results are also verified by measured results with fabricated antennas.

Effect of Salt Concentration on the Glass Transition Temperature and Ionic Conductivity of Poly(ethylene glycol)-Polyurethane/$LiClO_4$ Complexes

  • Huh, Pil-Ho;Park, Myung-Geun;Jo, Nam-Ju;Lee, Jin-Kook;Lee, Jang-Oo;Wongkang Yang
    • Macromolecular Research
    • /
    • v.12 no.4
    • /
    • pp.422-426
    • /
    • 2004
  • Solid polymer electrolytes based on poly(ethylene glycol)-polyurethane (PEG-PU) complexed with LiClO$_4$ salt have been prepared by the solvent casting method. A PEG-PU material (PEG:4,4'-diphenylmethane diisocyanate: l,4-butanediol = 1:2:1) was synthesized through a typical two-step condensation reaction. We investigated the effects of the salt concentration on the ionic conductivity ($\sigma$) and the glass transition temperature (T$_{g}$ ) of the complex electrolytes by using alternating current impedance spectroscopy, differential scanning calorimetry, and dynamic mechanical thermal analysis. The measured values of both $\sigma$ and T$_{g}$ exhibited similar tendencies in that they had maxima within the range studied, probably because of two opposite effects, i.e., the increased number of carrier ions and the decreased chain mobility (or increased T$_{g}$ ) caused by the increase in the salt concentration. The highest conductivity, on the order of 2.43 ${\times}$ 10$^{6}$ S$cm^{-1}$ /, was obtained at an [O]/[Li$^{+}$] ratio of ca. 16 (0.92 ㏖ salt per kg of matrix polymer).

The Design of a Wideband 3 dB Quadrature Coupler using N-Section Parallel-Coupled Lines (N단 평행 결합 선로를 이용한 90° 광대역 3 dB 결합기 설계)

  • 조정훈;윤상원
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.94-100
    • /
    • 2002
  • In this paper, we proposed a 3 dB coupler using N-section parallel-coupled lines and designed a very compact one based on the analysis results. The coupled line has been analyzed by spectral domain method. After we obtain the s-parameters of N-section parallel-coupled lines by using port reduction method 4-port s-parameters are derived. The 3 dB couplers, which were fabricated, are not necessary to implement high impedance lines and tight coupling gaps as Lange Couplers because loose coupling is used. To realize a minimum section, we used the PCB that has high a dielectric constant and a thickness. The experimental results show that it has wide bandwidth of about 42 %(0.5 dB unbalance) from 3.6 GHz to 5.5 GHz and phase difference within 1 degree. Also, The isolation characteristics about 15 dB at its pass-band are obtained.

Research of an On-Line Measurement Method for High-power IGBT Collector Current

  • Hu, Liangdeng;Sun, Chi;Zhao, Zhihua
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.362-373
    • /
    • 2016
  • The on-line measurement of high-power IGBT collector current is important for the hierarchical control and short-circuit and overcurrent protection of its driver and the sensorless control of the converter. The conventional on-line measurement methods for IGBT collector current are not suitable for engineering measurement due to their large-size, high-cost, low-efficiency sensors, current transformers or dividers, etc. Based on the gate driver, this paper has proposed a current measuring circuit for IGBT collector current. The circuit is used to conduct non-intervention on-line measurement of IGBT collector current by detecting the voltage drop of the IGBT power emitter and the auxiliary emitter terminals. A theoretical analysis verifies the feasibility of this circuit. The circuit adopts an operational amplifier for impedance isolation to prevent the measuring circuit from affecting the dynamic performance of the IGBT. Due to using the scheme for integration first and amplification afterwards, the difficult problem of achieving high accuracy in the transient-state and on-state measurement of the voltage between the terminals of IGBT power emitter and the auxiliary emitter (uEe) has been solved. This is impossible for a conventional detector. On this basis, the adoption of a two-stage operational amplifier can better meet the requirements of high bandwidth measurement under the conditions of a small signal with a large gain. Finally, various experiments have been carried out under the conditions of several typical loads (resistance-inductance load, resistance load and inductance load), different IGBT junction temperatures, soft short-circuits and hard short-circuits for the on-line measurement of IGBT collector current. This is aided by the capacitor voltage which is the integration result of the voltage uEe. The results show that the proposed method of measuring IGBT collector current is feasible and effective.

A Study on the Reverse-Power-Flow Phenomenon due to Transformer Wiring Types in Distribution System (배전계통에서 변압기 결선에 의한 역 조류현상에 관한 연구)

  • Shin, Dong-Yeol;Ha, Bok-Nam;Jung, Won-Wook;Cha, Han-Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.111-119
    • /
    • 2008
  • As the penetration of distributed generation systems is recently high, there have been metering errors, trips of protective devices in KEPCO distribution systems including an occurrence of false fault-indicator in distribution automation system. The cause of malfunctions was the reverse-power-flow phenomenon due to transformer wiring types. By the effect of the reverse-power-flow, each of phase's fundamental currents was added by about 3 times on the neutral line. A new method based on the analysis of the reverse-power-flow is proposed in this paper. Fault currents on each section were analyzed by the proposed method, and the effect of types of transformer wiring was examined experimentally. In order to reduce the malfunctions due to the reverse-power-flow, controlling the zero-sequence impedance of transformer was designed and verified by using PSCAD/EMTDC software.

Designing a Highly Sensitive Eddy Current Sensor for Evaluating Damage on Thermal Barrier Coating (열차폐코팅의 비파괴적 손상 평가를 위한 고감도 와전류 센서 설계)

  • Kim, Jong Min;Lee, Seul-Gi;Kim, Hak Joon;Song, Sung Jin;Seok, Chang Seong;Lee, Yeong-Ze
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.202-210
    • /
    • 2016
  • A thermal barrier coating (TBC) has been widely applied to machine components working under high temperature as a thermal insulator owing to its critical financial and safety benefits to the industry. However, the nondestructive evaluation of TBC damage is not easy since sensing of the microscopic change that occurs on the TBC is required during an evaluation. We designed an eddy current probe for evaluating damage on a TBC based on the finite element method (FEM) and validated its performance through an experiment. An FEM analysis predicted the sensitivity of the probe, showing that impedance change increases as the TBC thermally degrades. In addition, the effect of the magnetic shield concentrating magnetic flux density was also observed. Finally, experimental validation showed good agreement with the simulation result.

A Case Study of Taeeumin Patient with Edema Treated with Gunyuljejo-tang (태음인 부종 환자의 건율제조탕 치험 1례)

  • Han, Suzy;Yu, Jun-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.33 no.3
    • /
    • pp.138-145
    • /
    • 2021
  • Objectives Edema occurs in various disorders, such as heart failure, nephrotic syndrome, renal failure, liver cirrhosis, and cancer. The excessive accumulation of interstitial fluid in limb tissue will often manifest with ankle and knee swelling and lowers patient's quality of life. But the conventional treatment includes restricting dietary sodium and using diuretics. The purpose of this study is about significant improvement of a patient with edema who had suffered from dependent gait accompanied by mild pain, after treatment by herbal medicine based on SCM(Sasang constitutional medicine). Methods The pattern identification of the patient was diagnosed with a superficial disease of Taeeumin. So after the admission, Gunyuljejo-tang was used, almost two times per day during 2 weeks. Also, we applied acupuncture routinely every day and western medicine as needed. We measured the circumferences of Lt. thigh and followed up the bioelectrical impedance analysis and checked the appearance of lower limb. Results and Conclusions The therapy was effective, and the circumferences, which was 59.69cm at onset time, decreased to 52.07cm almost same to the healthy side of her thigh. There was no more edematous sign on the body, either. This case showed that management of Taeeumin's healthy energy(呼散之氣, the energy of exhalation) could be effective in treating edema.

The Consumption Pattern of Sugar-Sweetened Beverages and its Comparison with Body Composition Change from a Four-Week Time-Restricted Eating Intervention in Korean Young Adults (한국 젊은 성인의 4주간 시간제한식사 개입에서 살펴본 가당음료 섭취 패턴과 체조성 변화량과의 비교 분석)

  • Park, SuJeong;Song, YoonJu
    • Korean Journal of Community Nutrition
    • /
    • v.27 no.1
    • /
    • pp.36-46
    • /
    • 2022
  • Objectives: The purpose of this study was to evaluate the consumption pattern of sugar-sweetened beverages (SSB) and compare body composition changes by SSB consumption based on 28 days of dietary records from a four-week time-restricted eating intervention among young adults in Korea. Methods: A total of 33 participants completed the four-week dietary intervention with 8-hour time-restricted eating (TRE). The body composition was measured by bioelectrical impedance analysis at baseline, and daily dietary records were collected for 28 days during the intervention after 4 weeks. Results: Based on 924 days of dietary records, the average eating occasion of SSB was 0.9 times per day, and the average amount of SSB was 205.8 g/times. Based on an individual's usual intake of 28 days, the average eating frequency of SSB was 16.6 times out of 28 days, and the average amount of SSB was 184.0 g/day. The average energy intake from SSB was 131.0 kcal /day (8.7% of energy), and sugar intake from SSB was 18.2 g/day (4.9% of energy). The sugar intake was 2.6% of energy from sweetened dairy products, followed by 2.0% from coffee drinks, 0.5% from soda and juice and 0.2% from others. When subjects were divided into high (14 days or more) and low (less than 14 days) SSB groups based on eating frequency, the weight change in the low SSB group was -2.0 kg over 4 weeks, which was significantly lower than -0.7 kg in the high SSB group. However, no significant difference was found in muscle mass, fat mass and body fat percent between the two groups. Conclusions: This study suggests that low consumption of sugar-sweetened beverages is more desirable in weight management despite having the dietary intervention of time-restricted eating without counting calories. Thus, further longitudinal studies on the association between SSB and obesity in Korean adults are necessary.