• Title/Summary/Keyword: Impedance parameters

Search Result 596, Processing Time 0.026 seconds

Microwave Absorbing Properties of Iron Particles-Rubber Composites in Mobile Telecommunication Frequency Band (이동통신주파수 대역에서 순철 분말-고무 복합체 Sheet의 전파흡수특성)

  • Kim, Sun-Tae;Kim, Sant-Keun;Kim, Sung-Soo;Yoon, Yeo-Choon;Lee, Kyung-Sub;Choi, Kwang-Bo
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.131-137
    • /
    • 2004
  • For the aim of thin electromagnetic wave absorbers used in mobile telecommunication frequency band (0.8-2.0㎓), we investigate high-frequency magnetic, dielectric and microwave absorbing properties of iron particles dispersed in rubber matrix in this study. The major experimental variables are particle shape (sphere and flake) and initial particle size (in the range 5-70 $\mu\textrm{m}$) of iron powders. High value of magnetic permeability and dielectric permittivity can be obtained in the composites containing thin plate-shape (flake) iron particles (of which thickness is less than skin depth in ㎓frequency), which can be produced by mechanical forging of spherical iron powders using an attrition mill. This result is attributed to the reduction of eddy current loss (increase of permeability) and the increase of space charge polarization (increase of permeability). The optimum initial particle size is found to be about 10 $\mu\textrm{m}$ for the attainment of the material parameters (particularly, real part of complex permeability) satisfying the wave impedance matching. With the iron powders controlled in size and shape as absorbent fillers in rubber matrix, the thickness can be reduced to about 0.7mm with respect to -5㏈ reflection loss (70% power absorption) in mobile telecommunication frequency band.

Effects of Acupuncture Stimulation on the Radial artery's Pressure Pulse Wave in Healthy Young Participants: Protocol for a prospective, single-Arm, Exploratory, Clinical Study

  • Shin, Jae-Young;Ku, Boncho;Kim, Tae-Hun;Bae, Jang Han;Jun, Min-Ho;Lee, Jun-Hwan;Kim, Jaeuk U.
    • Journal of Pharmacopuncture
    • /
    • v.19 no.3
    • /
    • pp.197-206
    • /
    • 2016
  • Introduction: This study aims to investigate the effects of acupuncture stimulation on the radial artery's pressure pulse wave, along with various hemodynamic parameters, and to explore the possible underlying mechanism of pulse diagnosis in healthy participants in their twenties. Methods and analysis: This study is a prospective, single-arm, exploratory clinical study. A total of 25 healthy participants, without regard to gender, in their twenties will be recruited by physicians. Written informed consent will be obtained from all participants. The participants will receive acupuncture once at ST36 on both sides. The radial arterial pulse waves will be measured on the left arm of the subjects by using an applicable pulse tonometric device (KIOM-PAS). On the right arm (appearing twice), electrocardiogram (ECG), photoplethysmogram (PPG), respiration and cardiac output (CO) signals, will be measured using a physiological data acquisition system (Biopac module), while the velocity of blood flow, and the diameter and the depth of the blood vessel will be measured using an ultrasonogram machine on the right arm (appearing twice). All measurements will be conducted before, during, and after acupuncture. The primary outcome will be the spectral energy at high frequencies above 10 Hz ($SE_{10-30Hz}$) calculated from the KIOM-PAS device signal. Secondary outcomes will be various variables obtained from the KIOM-PAS device, ECG, PPG, impedance cardiography modules, and an ultrasonogram machine. Discussion: The results of this trial will provide information regarding the physiological and the hemodynamic mechanisms underlying acupuncture stimulation and clinical evidence for the influence of acupuncture on the pressure pulse wave in the radial artery. Ethics and dissemination: This study was approved by the Institutional Review Board (IRB) of Kyung Hee University's Oriental Medical Center, Seoul, Korea (KOMCIRB-150818-HR-030). The study findings will be published in peer-reviewed journals and presented at national and international conferences. Trial registration number: This trial was registered with the Clinical Research Information Service (CRIS) at the Korea National Institute of Health (NIH), Republic of Korea (KCT0001663), which is a registry in the World Health Organization's (WHO's) Registry Network.

Effect of Period of Immersion on Corrosion Potential, Anodic Polarization, and Impedance Characteristics of Reinforced Steel in Mortar (W/C: 0.6) (모르타르(W/C:0.6)의 철근의 부식전위와 양극분극 및 임피던스 특성에 미치는 재령 년수)

  • Jeong, Jae-Hyun;Moon, Kyung-Man;Lee, Sung-Yul;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.327-333
    • /
    • 2016
  • Reinforced concrete structures have found wide usage in land and maritime applications. However, the corrosion of reinforced concrete has been recognized as a serious problem from economic and safety standpoints. In previous studies, the corrosion behavior of the inner steel bar embedded in mortar (W/C: 0.4, 0.5) was investigated using electrochemical methods. In this study, multiple mortar test specimens (W/C: 0.6) with six different cover thicknesses were prepared and immersed in flowing seawater for five years. Subsequently, equations related to the cover thickness, period of immersion, and corrosion characteristics of the embedded steel bar were evaluated using electrochemical methods. Prior to immersion, the corrosion potentials indicated an increase with increasing cover thickness, and after five years, all corrosion potentials demonstrated a trend in the positive direction irrespective of the cover thickness. However, the relationships between the corrosion potential and cover thickness were not in complete agreement. Furthermore, after five years, all of the corrosion potentials indicated values that were nobler compared to those obtained prior to immersion, and their corrosion current densities also decreased compared to their values obtained prior to immersion. It was considered that the embedded steel bar was easily corroded because of the aggression of water, dissolved oxygen, and chloride ions; a higher W/C ratio also assisted the corrosion process. The corrosive products deposited on the surface of the steel bar for five years cast a resistance polarizing effect shifting the corrosion potential in the nobler direction. Consequently, it was considered that the W/C ratio of 0.6 showed nearly same results as those of W/C of 0.4 and 0.5. Therefore, the corrosion potential as well as various parameters such as the cover thickness, period of immersion, and W/C ratio must be considered at once for a more accurate evaluation of the corrosion property of reinforced steel exposed to marine environment for a long period.

A Study on 8 × 4 Dual-Polarized Array Antenna for X-Band Using LTCC-Based ME Dipole Antenna Structure (LTCC 기반 ME Dipole 안테나 구조를 활용한 X-Band 용 8 × 4 이중편파 배열안테나에 관한 연구)

  • Jung, Jae-Woong;Seo, Deokjin;Ryu, Jong-In
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.25-32
    • /
    • 2021
  • In this paper, the Magneto-Electric(ME) dipole array antenna with dual-polarization in the X-Band is proposed and it is implemented and measured. The proposed array antenna is composed of 32 single ME dipole antenna and a Teflon PCB. 1 × 1 ME dipole antenna is implemented dual-polarization by radiating vertical polarization and horizontal polarization from two pairs of radiators. 2-port feeding structures are realized by lamination process using LTCC. And, each port independently feeds the radiator through a Γ-shaped feeding strip with isolation between ports. The Teflon PCB used in the antenna array has a 4-layer structure, and 2-port is fed through the top and bottom layers. The λg/4 transformer is applied to the transmission line of the Teflon PCB for impedance matching of the arrayed antenna and the Teflon PCB, and the optimal parameters are obtained through simulation. The measured maximum antenna gains of port 1 was 18.2 dBi, Cross-pol was 1.0 dBi. And the measured maximum antenna gains of port 1 was 18.1 dBi, Cross-pol was 3.2 dBi.

Correlation of advanced glycation end products and heme oxygenase-1 in Korean diabetic patients (제2형 당뇨병 환자에서 최종당화산물과 heme oxygenase-1의 상관성)

  • Choi, Ha-Neul;Koo, Da-Hye;Yim, Jung-Eun
    • Journal of Nutrition and Health
    • /
    • v.55 no.3
    • /
    • pp.348-358
    • /
    • 2022
  • Purpose: Hyperglycemia accelerates the formation of advanced glycation end products (AGEs), a group of compounds formed via non-enzymatic glycation/glycoxidation. Type 2 diabetes mellitus (T2DM) is related to oxidative stress, resulting in some overgeneration of AGEs. The accumulation of AGEs in T2DM patients leads to increased inflammation, DNA damage, tissue damage, progression of diabetic microvascular disease, and nephropathy. Heme oxygenase-1 (HO-1) is an intracellular enzyme that catalyzes the oxidation of heme. Expression of HO-1 in the endothelium and in muscle monocytes/macrophages was upregulated upon exposure to reactive oxygen species or oxidized low-density lipoprotein. Cells activated by oxidative stress are reported to release HO-1 in the serum. In the current study, we discuss the oxidative status according to the level of AGEs and the association of HO-1 with AGEs or urinary DNA damage marker in type 2 diabetic Korean patients. Methods: This study enrolled 36 diabetic patients. Subjects were classified into two groups by serum AGEs level (Low AGEs group: < 0.85 ng/mL serum AGEs; High AGEs group: ≥ 0.85 ng/mL serum AGEs). Body composition was measured using bioelectrical impedance analysis. Blood and urinary parameters were measured using commercial kits. Results: No significant differences were observed in the general characteristics and body composition between the two groups. Serum HO-1 concentration was significantly higher in the High AGEs group than in the Low AGEs group. After adjustment of age and gender, a correlation was performed to assess the association between serum HO-1 and serum AGEs or urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG). Our results indicate that serum HO-1 is positively correlated with serum AGEs and urinary 8-OHdG. Conclusion: Taken together, our results indicate that in diabetes patients, a high level of HO-1 is associated with a high concentration of AGEs and 8-OHdG, probably reflecting a protective response against oxidative stress.

Effect of Individualized Exercise Program for Preventing Metabolic Syndrome among IT Company Office Workers (IT 기업 사무직 근로자의 대사증후군 예방을 위한 맞춤형 운동프로그램의 효과)

  • Kyungun Bae;Sung Hyun You;Dabi Shin;Yuncheol Ha;Hongmin Kim;Byungchan Pak;Hyosang Kim;Shinae Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.77-84
    • /
    • 2024
  • Objectives: Interventions promoting physical exercise and healthy habits in workplaces have been shown to be effective in reducing risk factors for metabolic syndrome. This study was conducted to examine the effects of an individualized conditioning exercise program of IT company office workers with or at higher risk of metabolic syndrome. Methods: A total of 444 IT company office workers with or at higher risk of metabolic syndrome participated in a 3-month conditioning exercise program. Body composition data using bioelectrical impedance analysis and cardiopulmonary data using cardiopulmonary exercise testing from 53 individuals (mean age: 34.8 ± 7.1 years, sex : 21% female, height : 170.4 ± 6.8 cm, weight : 75.2±12.2 kg, body mass index : 25.8±3.3 kg/m2) who have successfully completed pre-test, intervention, and post-test were analyzed. The 12 weeks intervention encompassed: (1) health counseling (2) supervised exercise(endurance-based, aerobic exercise, or circuit training once a week for 50 minutes at heart rate reserve(HRR) of 77-95%) (3) self-directed exercise and biweekly health screening checks. Results: The results indicated a significant decrease in body weight, body fat mass and body mass index, respectively. Moreover, VO2peak, AT VO2 and AT Time significantly improved, respectively. Resting blood pressure(SBP/DBP) showed positive changes but were not statistically significant. We observed the correlation between characteristics of participants and rate of changes in cardiopulmonary outcomes of participants, there are no significant correlation. These results indicate positive changes in body composition and cardiorespiratory fitness parameters following individualized conditioning exercise program. Conclusions: Individualized workplace exercise program for preventing metabolic syndrome can lead to improvements in body composition and cardiorespiratory fitness.

Nondestructive Quantification of Corrosion in Cu Interconnects Using Smith Charts (스미스 차트를 이용한 구리 인터커텍트의 비파괴적 부식도 평가)

  • Minkyu Kang;Namgyeong Kim;Hyunwoo Nam;Tae Yeob Kang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.2
    • /
    • pp.28-35
    • /
    • 2024
  • Corrosion inside electronic packages significantly impacts the system performance and reliability, necessitating non-destructive diagnostic techniques for system health management. This study aims to present a non-destructive method for assessing corrosion in copper interconnects using the Smith chart, a tool that integrates the magnitude and phase of complex impedance for visualization. For the experiment, specimens simulating copper transmission lines were subjected to temperature and humidity cycles according to the MIL-STD-810G standard to induce corrosion. The corrosion level of the specimen was quantitatively assessed and labeled based on color changes in the R channel. S-parameters and Smith charts with progressing corrosion stages showed unique patterns corresponding to five levels of corrosion, confirming the effectiveness of the Smith chart as a tool for corrosion assessment. Furthermore, by employing data augmentation, 4,444 Smith charts representing various corrosion levels were obtained, and artificial intelligence models were trained to output the corrosion stages of copper interconnects based on the input Smith charts. Among image classification-specialized CNN and Transformer models, the ConvNeXt model achieved the highest diagnostic performance with an accuracy of 89.4%. When diagnosing the corrosion using the Smith chart, it is possible to perform a non-destructive evaluation using electronic signals. Additionally, by integrating and visualizing signal magnitude and phase information, it is expected to perform an intuitive and noise-robust diagnosis.

Anthropometric Measurements of the Upper and Lower Body Balance and Exercise Habit among Female College Students in Some Parts of the Gyeongnam (경남 일부 지역 여자 대학생의 상하체 균형 계측치와 운동 습관)

  • Kim, Young-Sik;Yoon, Im-Sil;Lee, Won-Joon;Nam, Jeong-Su;Yoon, Joong-Soo;Youn, Ryea-Min;Jung, Han-Na;Ko, Jae-Shik;Choi, Hyun-Ju
    • Journal of Life Science
    • /
    • v.20 no.4
    • /
    • pp.535-542
    • /
    • 2010
  • This study was carried out to examine anthropometric parameters and related habits in female college students. Mean age, height, and body weight of the subjects in total (n=212) were 20.7 yrs, 161.8 cm, and 53.5 kg, respectively. Anthropometric parameters were measured by bioelectrical impedance analysis. Mean degree of obesity, body mass index (BMI), and waist-hip ratio (WHR) were 98.4%, $20.6\;kg/m^2$, and 0.80 respectively. Surprisingly, 63.7% of the subjects showed unbalanced weak upper bodies compared to their lower bodies. Therefore, they were divided into two groups: unbalanced weak upper body group (UU, n=135) and balanced upper body groups (BU, n=77). Bodyweight, degree of obesity, BMI, and WHR in the UU group were significantly lower than those in the BU group. Amounts of body protein, body fat, and body mineral in the UU group were also significantly lower than those of the BU group. Mid-arm muscle circumference of the UU group ($18.5{\pm}0.8\;cm$) was significantly lower than those of BU group ($20.4{\pm}1.2\;cm$), although mid-arm circumference of the UU group was not significantly different compared to those of the BU group. On a questionnaire on exercise habits, 1.5% of the UU group and 7.8% of the BU group answered that they exercised regularly, and 55.5% of the UU group and 31.2% of the BU group reported that they never exercised (p<0.01). Even in the subjects who exercised, the duration of the exercise was not sufficient because 38.4% of the UU group and 35.8% of the BU group answered that they exercised for less than 30 min. In conclusion, interventions in exercise habits may be needed for female college students who have unbalanced weak upper bodies.

The Effect of Body Mass Index, Fat Percentage, and Fat-free Mass Index on Pulmonary Function Test -With Particular Reference to Parameters Derived from Forced Expiratory Volume Curve- (신체질량지수 및 체지방률, 그리고 제지방지수가 폐기능 검사에 미치는 영향 -노력성 호기곡선을 중심으로-)

  • Park, Ji Young;Pack, Jong Hae;Park, Hye Jung;Bae, Seong Wook;Shin, Kyeong Cheol;Chung, Jin Hong;Lee, Kwan Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.2
    • /
    • pp.210-218
    • /
    • 2003
  • Background : Sex specific cross sectional reference values for the lung function indices usually employ a linear model with a term for age and height. The purpose of this study was to determine the effects of the body mass index (BMI), the fat percentage of the body mass and the fat-free mass index (FFMI) on the forced expiratory volume curve. Methods : Between January 2000 and December 2001, a total of 300 subjects, 150 men and 150 women (mean age : $45{\pm}13$ years), with a normal lung function were enrolled in the study sample. This study measured the $FEV_1$, FVC and $FEF_{25-75%}$ from the forced expiratory volume curve by a spirometer and the body composition by a bioelectrical impedance method in all subjects. Multiple regression analysis was used in order to examine the effects of the body composition on the parameters derived from the forced expiratory volume curve. Results : After adjusting for age, the BMI and Fat percentage improved the descriptions of the FVC (p<0.05, $r^2=0.491$) and $FEV_1$ (p<0.05, $r^2=0.654$) in women. In contrast, the FFMI contributed significantly to the FVC (p<0.05, $r^2=0.432$) and $FEV_1$ (p<0.05, $r^2=0.567$) in men. The $FEF_{25-75%}$ correlated with the fat percentage in women (p<0.05, $r^2=0.337$). Conclusion : These results suggest that the BMI, the fat percentage and the FFMI are significant determinants of the forced expiratory volume curve. The plmonary function test, when considering the BMI, the fat percentage and the FFMI, might be useful in clinical applications.

Derivation of rock parameters from Televiewer data (텔레뷰어에 의한 토목설계 매개변수의 산출)

  • Kim Jung-Yul;Kim Yoo-Sung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.137-155
    • /
    • 1999
  • Recently, Televiewer(Borehole Acoustic Scanner(Televiewer)) has come to be widely used specially for the general engineering construction design. The Televiewer tool using a focussed acoustic beam is to detect the amplitude and traveltime of each reflected acoustic signal at the wall, resulting in the amplitude- and traveltime image respectively. Fractures can be well detected, because they easily scatter the acoustic energy due to the highly narrow beam. In addition, the drilling work will rough the borehole wall so that the acoustic energy can be scattered simply due to the roughness of the wall. Thus, the amplitude level can be directed associated with the elastic properties(impedance) and the hardness of the rock as well. Meanwhile, the traveltime image provides an information about the borehole shape and can be converted to a high precision 3D caliper log(max. 288 arms). In this paper, based on the high resolution of Televiewer images, general evaluation methods are illustrated to derive very reliable rock parameters.

  • PDF