• 제목/요약/키워드: Impedance Transformer

검색결과 212건 처리시간 0.025초

A Short Wavelength Coplanar Waveguide Employing Periodic 3D Coupling Structures on Silicon Substrate

  • Yun, Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권2호
    • /
    • pp.118-120
    • /
    • 2016
  • A coplanar waveguide employing periodic 3D coupling structures (CWP3DCS) was developed for application in miniaturized on-chip passive components on silicon radio frequency integrated circuits (RFIC). The CWP3DCS showed the shortest wavelength of all silicon-based transmission line structures that have been reported to date. Using CWP3DCS, a highly miniaturized impedance transformer was fabricated on silicon substrate, and the resulting device showed good RF performance in a broad band from 4.6 GHz to 28.6 GHz. The device as was 0.04 mm2 in size, which is only 0.74% of the size of the conventional transformer on silicon substrate.

광대역임피던스 정합용변성기의 설계 및 제작에 관한 연구 (A Study on the Design and Performance of Broad-Band Impedance Matching Transformer)

  • 조한형;최승철
    • 한국통신학회논문지
    • /
    • 제13권6호
    • /
    • pp.501-509
    • /
    • 1988
  • 토로이달코아와 상호절연된 撚線을 사용하여 30MHz~90MHz대역에 사용할 수 있는 새로운 형태의 임피던스 정합용변성기를 설계하고 제작하였다. 측정결과 전주파수대역에서 삽입손실 1.2[dB]이하, 정재파비2.0이하이었으며 100[%]의 대역폭으로 비교적 좋은 특성을 보여주고 있다. 제안한 변성기는 간편하고 제작이 용이하기 때문에 종래의 주파수절환형태의 정합회로를 대체하여 사용이 가능하리라 생각된다.

  • PDF

Ring Filters and Small-Sized Wideband Ring Filters

  • Ahn, Hee-Ran;Myung, Noh-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • 제3권2호
    • /
    • pp.104-110
    • /
    • 2003
  • A ring filter is proposed as a wide-banded filter. It consists of a ring and two short stubs, which are connected at 90$^{\circ}$ and 270$^{\circ}$ points of the ring. Since the termination impedance at 90$^{\circ}$ and 270$^{\circ}$ points of the ring and the characteristic impedance of the short stub have an effect on designing of it, the relation between them and bandwidths has been studied. Based on the study, two types of small-sized wideband CVT(constant VSWR-type impedance transformer)- and CCT(constant conductance-type impedance transformer)-ring filters are introduced, designed, simulated and one of two, a CCT -ring filter, is tested. The circumference of the ring can be reduced theoretically up to 60$^{\circ}$ and two of many cases having about 300$^{\circ}$ circumferences are simulated. The simulated results show more than 100 % fractional bandwidth, which can be obtained with more than 5 stages in conventional filter-design techniques. To test the designed CCT-ring filter, it has been fabricated in microstrip technology and the measured results show good agreement with the simulated ones, having more than 100 % fractional bandwidth.

무전극램프의 출력전력 변화에 따른 새로운 모델링 기법 (New Modeling Method for an Electrodeless Fluorescent Lamp Using the Relation of Lamp Output Power and the Modeling Coefficients of the Lamp)

  • 임병노;장목순;신동석;박종연
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1626-1631
    • /
    • 2007
  • This paper presents a new modeling method using lamp output power and the modeling coefficients of the lamp. The proposed method utilizes the lamp modeling coefficients such as equivalent impedance Z(p), coupling coefficient of the transformer k(p), turns ratio of the transformer n(p), and plasma resistance Rp(p) as a function of lamp output power. The equivalent impedance Z(p) was developed from the equivalent resistance Req(p) and equivalent inductance Leq(p) of the lamp. Simulation and experimental results of the proposed model are presented in order to validate the proposed method. The modeling method can use to design an impedance matching circuit for a Class-D inverter.

이중 대역 L형 임피던스 변환기 (Dual-band L-section Impedance Transformer)

  • 박면주
    • 한국ITS학회 논문지
    • /
    • 제9권5호
    • /
    • pp.67-71
    • /
    • 2010
  • 본 논문에서는 L-형 회로구조에 기반한 새로운 이중대역 임피던스 변환기를 제안한다. 제안된 회로는 전원 또는 부하단에 하나의 스터브 선로가 부착된 전송선로를 사용하여 구성된다. 각 회로 구조와 부하조건에 대해 이중대역 동작조건을 자세히 분석하였으며 이로부터 선로의 길이와 임피던스 등의 이중대역 설계 공식을 간단한 형태로 유도하였다. 제안된 방법을 이용하여 이중대역 임피던스 정합회로를 설계하고 마이크로스트립 회로로 제작, 측정하여 이중대역 동작을 확인하였다.

유전체 공진기를 이용한 4:1(50-Ω:12.5-Ω) 마이크로스트립-슬롯 선로 임피던스 변환기 (The 4:1(50-Ω:12.5-Ω) microstrip-slot line impedance transformer using a dielectric resonator)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제24권11호
    • /
    • pp.1484-1491
    • /
    • 2020
  • 슬롯 선로는 슬롯을 통해 전계와 자계 신호가 전달되기 때문에 슬롯의 크기가 전력 손실에 크게 영향을 준다. 일반 적으로 슬롯 선로는 낮은 전력 손실로 동작하기 위해 상대적으로 높은 비유전율(er)의 기판에서 3GHz 이상의 높은 주파수에서 사용하게 된다. 본 논문에서는 상대적으로 낮은 비유전율(er)을 가지는 Taconic사의 TLC-30(er=3) 기판을 이용하여 중심주파수 1.85GHz에서 동작하는 슬롯 선로를 이용한 4:1 임피던스 변환기를 제안하였다. 제안된 임피던스 변환기에서의 슬롯 선로는 슬롯 선로 위에 유전체 공진기를 배치하여 슬롯 선로에서의 신호 손실을 줄였다. 비유전율(er) 38의 (Zr,Sn)TiO4을 이용하여 만든 유전체 공진기를 사용한 4:1 마이크로스트립-슬롯 선로 임피던스 변환기는 1.855GHz에서 삽입 특성(S21) -0.375dB와 반사 특성(S11) -27.6dB를 보였다. 이는 유전체 공진기를 이용하면 상대적으로 낮은 비유전율 기판과 낮은 주파수 영역에서도 안정적으로 슬롯 선로를 이용할 수 있음을 확인할 수 있었다.

Electrical Charateristics of Step-down Piezoelectric Transformer

  • Shin Hoonbum;Ahn HyungKeun;Han Deuk-Young
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.47-51
    • /
    • 2001
  • In this paper, we have explained electrical characteristics of a step-down Rosen type piezoelectric transformer for AC-adapter. When the electric voltage is applied to the driving piezoelectric vibrator polarized in the longitudinal direction, then output voltage is generated at the generating piezoelectric vibrator polarized in the thickness direction due to the piezoelectric effects. From the piezoelectric direct and converse effects, symbolic expressions between the electric inputs and outputs of the step-down piezoelectric transformer have derived with an equivalent circuit model. With the symbolic expressions, load and frequency characteristics have discussed through simulation. Output voltage and current from a 11-layered and a 13-layered piezoelectric transformers were measured under the various conditions of loads and frequencies. First we measured resonant frequency from impedance curve and got equivalent impedance value of the piezoelectric transformer from admittance plot. It was shown from experiments that output voltage has increased and resonant frequency has changed according to various resistor loads. Output current has decreased inversely proportional to changing of loads. Moreover, the measured values of output voltage and current are well agreed with the simulated values of the proposed equivalent circuit model.

  • PDF

누설집중형 변압기를 이용한 전계결합형 무선전력전송 시스템의 부피저감 최적설계 연구 (Optimal Design of Volume Reduction for Capacitive-coupled Wireless Power Transfer System using Leakage-enhanced Transformer)

  • 최희수;정채호;최성진
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.469-475
    • /
    • 2017
  • Using impedance matching techniques as a way to increase system power transferability in capacitive wireless power transmission has been widely investigated in conventional studies. However, these techniques tend to increase the circuit volume and thus counterbalance the advantage of the simplicity in the energy link structure. In this paper, a compact circuit topology with one leakage-enhanced transformer is proposed in order to minimize the circuit volume for the capacitive power transfer system. This topology achieves a reactive compensation, and the system quality factor value can be reduced by the turn ratio. As a result, this topology not only reduces the overall system volume but also minimizes the voltage stress of the link capacitor. An optimal design guideline for the leakage-enhanced transformer is also presented. The advantages of the proposed scheme over the conventional method in terms of power efficiency and circuit volume are revealed through an analytic comparison. The feasibility of applying the new topology is also verified by conducting 50 W hardware tests.

50 kVA 주상용 몰드변압기의 설계 및 특성평가 (The Design and Performance Test of Mold Transformer for Outdoor Pole)

  • 조한구;이운용;황보국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

변압기 여자돌입에 의한 전력품질 분석 (Analysis of Power Quality by Transformer Inrush Current)

  • 서훈철;여상민;김철환;유영식;조범섭
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.932-937
    • /
    • 2008
  • The transformer inrush current can cause a voltage drop by source impedance. This current can impact sensitive loads by the voltage drop. Therefore, it is necessary to take measures to limit this inrush current. This study, described in this paper, analyzes the power quality affected by transformer inrush current using the X power system in Korea. The Electromagnetic Transients Program(EMTP) is used to analyze the transient phenomenon. We discuss a method to model the hysteresis curve of the transformer in EMTP. We carried out various simulations to analyze the power quality during transformer energization. The analysis results of voltage drop by the inrush current occurrence when certain requirements are met are presented.