• 제목/요약/키워드: Impedance Meter

검색결과 61건 처리시간 0.023초

Predicting body compositions of live finishing pigs based on bioelectrical impedance analysis

  • An, Ji Seon;Lee, Ji Hwan;Song, Min Ho;Yun, Won;Oh, Han Jin;Kim, Yong Ju;Lee, Jun Soeng;Kim, Hyeun Bum;Cho, Jin Ho
    • Journal of Animal Science and Technology
    • /
    • 제63권2호
    • /
    • pp.332-338
    • /
    • 2021
  • The objective of this study was to predict body compositions of live pigs using bioelectrical impedance procedures. In experiment 1, 32 crossbred (Duroc × Landrace × Yorkshire) finishing pigs with an average weight at 84.06 kg were used. In experiment 2, 96 crossbred (Duroc × Landrace × Yorkshire) finishing pigs with an average weight at 88.8 kg were used. A four-terminal body composition analyser was utilized to determine fat percentage. Lean meat percentage and backfat thickness were measured with a lean meat measuring meter. In experiment 1, fat percentage was not significantly correlated with lean meat percentage, although a tendency (p < 0.1) of a negative correlation was found. Backfat thickness was significantly correlated with fat percentage and lean meat percentage (r = 0.745 and r = -0.961, respectively). Coefficients of determination for fat percentage with lean meat percentage, fat percentage with backfat thickness, and backfat thickness with lean meat percentage were 0.503, 0.566, and 0.923, respectively. In experiment 2, fat percentage was significantly correlated with lean meat percentage (r = -0.972). Backfat thickness was also significantly correlated with fat percentage and lean meat percentage (r = 0.935 and r = -0.957, respectively). Results of this study indicate that bioelectrical impedance analysis might be useful for predicting body compositions of live finishing pigs.

전력선 통신 시스템 설계를 위한 주택배선의 선로특성 분석 (Analysis of Characteristics of Residential Distribution Line for Design of Power Line Communication Systems)

  • 홍덕표;최재호
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.99-104
    • /
    • 2005
  • 본 논문에서는 주택에서 전력선을 이용한 전력선 통신(PLC)을 위해 기본적으로 선행되어야 하는 선로정수를 측정하고 분석하였다. 주택의 표준적인 선로정수 분석을 위해서 국내 주택의 보편적인 형태의 아파트를 모델로 하였으며 Agilent 4263B LCR Meter를 이용하여 구간별로 세부적인 측정을 하여 구체적인 결과를 표로 나타내고 평균을 취하여 분석하였다. 측정한 결과 일반적인 수식으로 계산한 값과는 선로배열, 기본적으로 무시된 전제조건과 복소 유전율 등으로 인한 차이가 있음을 확인하였다. 또한 국내 주택의 시공에서 주로 사용되는 전선의 종류와 배선형태를 나타내었으며 선로 특성을 주파수영역에서 분석하여 전력선 통신 시스템의 설계 자료로 활용할 수 있도록 하였다.

반사 신호를 이용한 용량 성 센서의 신호처리 및 이를 이용한 초정밀 간극 측정 (Reflective Signal Based Signal Contioning of Capacitive Sensor and High Precision Gap Measurement)

  • 김재근;이택주;임수철;박경수;박노철;박영필;엄원석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.537-537
    • /
    • 2010
  • High precision sensing is very important in various technologies. Especially, it is more important when it were applied to nano/micro meter level's sensing like AFM, storage, etc. And capacitive sensing is widely used method. To improve the measurement efficiency, many signal conditioners were studied and one of them was surface acoustic wave (SAW) device. SAW device is very widely used as a high frequency bandwidth filter. Due to the reflective characteristic of high frequency, the response of SAW device contains both propagative and reflective signal at the external impedance. In this paper, we used SAW device as signal conditioner of capacitive sensor. And high precision gap measurement was executed using capacitive load. Reference signal was reflective SAW response and the magnitude at the center frequency of SAW device by the change of impedance was checked. Finally, the attainable gap resolution was determined.

  • PDF

경사각 이상유동양식 천이에 관한 실험적 연구 (Experimental study on flow pattern transitions for inclined two-phase flow)

  • 곽남이;김만웅;이재영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3021-3026
    • /
    • 2007
  • In this paper, experimental data on flow pattern transition of inclination angles from 0-90 are presented. A test section is constructed 2 mm long and I.D 1inch using transparent material. The test section is supported by aluminum frame that can be placed with any arbitrary inclined angles. The air-water two-phase flow is observed at room temperature and atmospheric condition using both high speed camera and void impedance meter. The signal is sampled with sampling rate 1kHz and is analyzed under fully-developed condition. Based on experimental data, flow pattern maps are made for various inclination angles. As increasing the inclination angels from 0 to 90, the flow pattern transitions on the plane jg-jf are changed, such as stratified flow to plug flow or slug flow or plug flow to bubbly flow. The transition lines between pattern regimes are moved or sometimes disappeared due to its inclined angle.

  • PDF

Humidity Sensor Using an Air Capacitor

  • Choi, Jin Moon;Kim, Tae Wan
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권4호
    • /
    • pp.182-186
    • /
    • 2013
  • We studied the possibility that an air capacitor can be used as a humidity sensor by measuring capacitance change. In order to investigate the possibility, the change of capacitance of an air capacitor due to moisture in air was first considered theoretically, and was then experimentally verified. The capacitance was measured by an LCR impedance meter with a 100-kHz and 1-V ac. The results revealed that the changes in the experimentally measured capacitances were greater than those in the theoretically calculated values. Based on this fact, we knew that an air capacitor could be used as part of a humidity sensing device. We expect the humidity sensor with an air capacitor has characteristics of fast response time, high reliability, and high durability compared with other conventional methods.

마이크로파 자유공간 전송을 이용한 산물벼 함수율 측정장치 개발 (Development of Moisture Content Measurement Device for Paddy Rice using Microwave Free Space Transmission)

  • 김기복;김종헌;노상하
    • Journal of Biosystems Engineering
    • /
    • 제24권3호
    • /
    • pp.235-242
    • /
    • 1999
  • This study was conducted to develop a grain moisture meter using microwave free space transmission technique at X-band frequency. The 10.5GHz microwave oscillator using a dielectric resonator was designed and fabricated to transmit electromagnetic wave through standard horn antenna to a sample holder with the wetted Hwasung and Chuchung rough rice(12.00∼26.25%). To detect the output voltage of transmitted wave from receiving horn antenna, the detector was composed of shottkey diode and RF impedance matching circuit. The regression model for measurement of grain moisture content was developed. Its correlation coefficient and standard error of prediction (SEP) were found to be 0.9882 and 0.657 respectively between measure and predicted moisture contents.

  • PDF

무채혈 혈당 측정기의 혈당 측정 원리: 혈당 검출방법 중심으로 (Blood Glucose Measurement Principles of Non-invasive Blood Glucose Meter: Focused on the Detection Methods of Blood Glucose)

  • 안원식;김진태
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권3호
    • /
    • pp.114-127
    • /
    • 2012
  • Recent technical advancement allows noninvasive measurement of blood glucose. In this literature, we reviewed various noninvasive techniques for measuring glucose concentration. Optical or electrical methods have been investigated. Optical techniques include near-infrared spectroscopy, Raman spectroscopy, optical coherence technique, polarization, fluorescence, occlusion spectroscopy, and photoacoustic spectroscopy. Electrical methods include reverse iontophoresis, impedance spectroscopy, and electromagnetic sensing. Ultrasound, detection from breath, or fluid harvesting technique can be used to measure blood glucose level. Combination of various methods is also promising. Although there are many interesting and promising technologies and devices, there need further researches until a commercially available non-invasive glucometer is popular.

Influence of ionic liquid additives on the conducting and interfacial properties of organic solvent-based electrolytes against an activated carbon electrode

  • Kim, Kyungmin;Jung, Yongju;Kim, Seok
    • Carbon letters
    • /
    • 제15권3호
    • /
    • pp.187-191
    • /
    • 2014
  • This study reports on the influence of N-butyl-N-methylpyrrolidinium tetrafluoroborate ($PYR_{14}BF_4$) ionic liquid additive on the conducting and interfacial properties of organic solvent based electrolytes against a carbon electrode. We used the mixture of ethylene carbonate/dimethoxyethane (1:1) as an organic solvent electrolyte and tetraethylammonium tetrafluoroborate ($TEABF_4$) as a common salt. Using the $PYR_{14}BF$ ionic liquid as additive produced higher ionic conductivity in the electrolyte and lower interface resistance between carbon and electrolyte, resulting in improved capacitance. The chemical and electrochemical stability of the electrolyte was measured by ionic conductivity meter and linear sweep voltammetry. The electrochemical analysis between electrolyte and carbon electrode was examined by cyclic voltammetry and electrochemical impedance spectroscopy.

A Simple a.c. Magnetic Susceptometer Using self-inductance Measurement of a Single Coil Mounted on a Cryostat Cold Head

  • Dho, Joong-Hoe
    • Journal of Magnetics
    • /
    • 제13권4호
    • /
    • pp.177-181
    • /
    • 2008
  • A very simple a.c. magnetic susceptometer for use in a helium closed cycle cryostat is reported in this paper. This simple setup has only a single bobbin-less copper coil, instead of the primary coil and two secondary coils typically used in mutual-inductance types. The single bobbin-less copper coil is directly mounted on the cryostat cold head. A sample is attached on the inside wall of the copper coil using a thermal contact material and its a.c. magnetic susceptibility is obtained from the measurement of the self-inductance of the sample coil using an LCR meter or an impedance analyzer. Experimental details are described and illustrative measurements on magnetic and superconducting materials as a function of temperature are included. The performances and limitations of this simple a.c. magnetic suceptometer are also discussed.

정공 수송층 두께 변화에 따른 OLED의 유전 특성 (Dielectric Properties in OLED depending on Thickness Variation of Hole Injection Layer)

  • 차기호;이영환;김원종;조경순;신종열;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 학술대회 및 기술세미나 논문집 디스플레이 광소자
    • /
    • pp.52-53
    • /
    • 2006
  • ITO/ polytetrafluorethylene (PTFE)/ Tris(8-hydroxyquinolinato Aluminum ($Alq_3$)/ Al 구조에서 정공 수송층 PTFE의 두께 변화에 따른 유전특성은 HP 4284A precision LCR Meter를 이용하여 주파수에 따른 임피던스와 위상각, 유전손실, 그리고 커패시턴스를 측정하였다. 측정 결과 PTFE의 두께가 증가할수록 임피던스 값은 증가하고, 위상각은 저주파수 영역에서는 두께가 증가할수록 감소하다가 고주파수 영역에서는 거의 같아지는 것을 확인하였다. 또한, 유전손실도 저주파수 영역에서는 정공 수송층이 증가할수록 감소하다가 고주파수 영역에서는 거의 같아졌고, 커패시턴스는 PTFE의 두께가 증가함에 따라 작아지고 주파수가 높아질수록 감소함을 확인하였다.

  • PDF