• Title/Summary/Keyword: Impact noise test

Search Result 276, Processing Time 0.025 seconds

Suggestion of assessment height for noise measurement according to the vertical radiation characteristics of railway noise (철도소음의 높이별 방사특성을 고려한 수음 평가 위치 제안)

  • Cho, Jun-Ho;Jang, Kang-Seok
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.1
    • /
    • pp.29-37
    • /
    • 2014
  • Exact and precise noise measurement is the basis for the reduction measure R&D, impact assessment and prediction modeling for railway noise. In this study, research trend as well as national and international noise measurement standard are investigated. For the estimation of vertical radiation characteristics of railway noise, specially devised zig was used. From the noise measurement and analysis, exact noise height radiated from the railway was characterized. The obtained results will be used for the suggestion of the height of microphone position of railway noise measurements.

Floor Impact Sound Isolation Performance by Composition of Ceiling and Wall (천장 및 벽구성 방법이 바닥충격음 차단성능에 미치는 영향에 관한 연구)

  • Kim Kyoung-Woo;Kang Jea-Sik;Lee Seung-Eon;Yang Kwan-Seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.465-473
    • /
    • 2005
  • The impact sounds, generated by the walking of people, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The characteristics and level of this impact noise depends on the object striking the floor, on the basic structure of the floor, and on the finish materials of floor. The focus of this paper is to investigate the amount of improvement impact sound pressure level according to the change of the composition method of ceiling and wall. For this purpose, we tested impact sound pressure level of several cases which is the inserting of mineral wool, the increase of the thickness of air layer, the using of anti-vibration rubber in ceiling and attach the mineral wool on wall in the Floor Impact Sound Test Building of KICT. The results show that the composition method of ceiling and wall is more effective in the reduction of light weight impact sound specially in 125Hz and 250Hz.

Evaluation of Floor Impact Sound Performance according to the installation of Ceiling and Wall (천장 및 벽구성 방법에 따른 바닥충격음 특성평가)

  • Kim, Kyoung-Woo;Choi, Hyun-Jung;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.261-264
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the installation of ceiling and wall. In this test, we measured the reduction of impact sound in the case of inserting absorption materials, increasing of the thickness of air layer and using anti-vibration rubber in ceiling, install of absorption materials in wall. The results of this study show that treatment of ceiling and wall have some reduction of the light weight impact sound and heavy weight impact sound.

  • PDF

Rating Floor Impact Noise in Apartment Buildings Through Subjective Evaluation Tests (청감실험에 의한 공동주택 바닥충격음의 평가등급 설정)

  • 전진용;류종관
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.88-95
    • /
    • 2003
  • The auditory experiments based on subjective responses were undertaken for the standard heavy and light weight impact noise and rubber ball impact noise, jumping noise to investigate relations between floor Impact noise levels and subjective responses and to establish the upper/lower limits of floor impact noises. As a result, it was shown that relations between floor Impact noise levels and subjective responses was linear and the lower limit of heavy-weight impact noise was L/sub i, Fmax, AW/=46㏈ and the lower limit of light-weight impact noise was L'/sub n,AW/=56㏈. Finally the 3 subjective classes of floor impact noises were established.

The Correlation Study of the Jury Test and Sound Quality Metrics Evaluation for Impact Sound of the Golf Club (골프채 타격음에 대한 청취실험과 음질 평가지수 관련 연구)

  • Park, Hee-Jun;Kim, Kwan-Ju;Park, Jin-Gue;Kim, Sang-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.595-598
    • /
    • 2005
  • The impact sound of the golf club is one of the major factors to purchase it. Sound qualify evaluation techniques are mostly developed for harmonic sounds. Sound quality metrics for the impact sound is proposed in this study. Jury test, one of the typical subjective evaluation scheme, is carried out for evaluating the sound quality of 11 different golf drivers. Above subjective classification results are assumed to be the right answers. Conventional objective evaluation methods such as Zwicker loudness sensory pleasantness are calculated. Wavelet analysis and instantaneous loudness are applied in order to evaluate the transient sounds, which shows better correlation with the results from those by jury test.

  • PDF

Noise and Vibration Characteristics of Floor Impact in a Test Building (표준실험동에서의 소음.진동 특성)

  • Jeong, Young;Yoo, Seung-Yup;Lee, Pyoung-Jik;Jeong, Jeong-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.92-95
    • /
    • 2005
  • In this study, Heavy-weight floor impact sound and vibration in concrete structures with different slab thickness have been measured in a test building. It was found that natural frequency increased according to increases of slab thickness, and acceleration level decreases. Results also show that the measurements in the 210 and 240mm slab structures are complied with the result from finite element analysis but the In and 180mm slab structures are not because the structures are constrained to the ground. Therefore, in modelling process the condition of sub-structures should be examined in relation to the boundary conditions.

  • PDF

Evaluation of Optimum Contents of Hydrated-Lime and Anti-Freezing Agent for Low-Noise Porous Asphalt Mixture considering Moisture Resistance (수분민감성 관련 소석회 및 박리방지제 첨가 투수성 가열 아스팔트 혼합물의 최적 함량 평가)

  • Kim, Dowan;Lee, Sangyum;Mun, Sungho
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.123-130
    • /
    • 2016
  • OBJECTIVES : The objective of this research is to determine the moisture resistance of the freeze-thaw process occurring in low-noise porous pavement using either hydrated-lime or anti-freezing agent. Various additives were applied to low-noise porous asphalt, which is actively paved in South Korea, to overcome its disadvantages. Moreover, the optimum contents of hydrated-lime and anti-freezing agent and behavior properties of low-noise porous asphalt layer are determined using dynamic moduli via the freeze-thaw test. METHODS : The low-noise porous asphalt mixtures were made using gyratory compacters to investigate its properties with either hydrated-lime or anti-freezing agent. To determine the dynamic moduli of each mixture, impact resonance test was conducted. The applied standard for the freeze-thaw test of asphalt mixture is ASTM D 6857. The freeze-thaw and impact resonance tests were performed twice at each stage. The behavior properties were defined using finite element method, which was performed using the dynamic modulus data obtained from the freeze-thaw test and resonance frequencies obtained from non-destructive impact test. RESULTS : The results show that the coherence and strength of the low-noise porous asphalt mixture decreased continuously with the increase in the temperature of the mixture. The dynamic modulus of the normal low-noise porous asphalt mixture dramatically decreased after one cycle of freezing and thawing stages, which is more than that of other mixtures containing additives. The damage rate was higher when the freeze-thaw test was repeated. CONCLUSIONS : From the root mean squared error (RMSE) and mean percentage error (MPE) analyses, the addition rates of 1.5% hydrated-lime and 0.5% anti-freezing agent resulted in the strongest mixture having the highest moisture resistance compared to other specimens with each additive in 1 cycle freeze-thaw test. Moreover, the freeze-thaw resistance significantly improved when a hydrated-lime content of 0.5% was applied for the two cycles of the freeze-thaw test. Hence, the optimum contents of both hydrated-lime and anti-freezing agent are 0.5%.

Development of a Laboratory Test Device for the Performance Evaluation of Light-weight Impact Sound (경량충격음 성능 평가를 위한 실험실용 시험장치 개발)

  • 양수영;홍병국;송화영;김범수;이동훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.505-508
    • /
    • 2004
  • 단열완충재 제품간의 경량충원 저감성능 평가를 객관적이고 신속하게 판별하기 위하여 실험실용 시험장치를 개발하였다. EVA계열 및 EPPㆍEPS계열의 단열완충재들에 대한 경량충격원 시험에서 제품간의 성능비교가 가능하였으며, 동탄성계수 및 손실계수 측정과 병행함으로써 제품들간의 우열성을 보다 정밀하게 평가할 수 있었다.

  • PDF

Environmental Impact on the KEPCO 765-kV Double Circuit Transmission Line (한전 765 kV 2회선 송전선로의 전기환경장애 특성)

  • Lee, D.I;Sin, K.Y;Kim, J.B
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.117-126
    • /
    • 1999
  • The environmental impact of the KEPCO 765-kV transmission line was studied using a full scale test line in order to develop the design technology. Therefore this paper describes an environmental design summary of the audible noise, hum noise, wind noise, radio interference, TV interference and electric field measurement from the KEPRI 765-kV double circuit transmission test line with a bundle of $6-480mm^2$ conductors per phase. The analysis of the test results shows that 6-Rail and 6-Cardinal conductors bundle satisfy the audible noise criterion & TV interference under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion for KEPCO 765-kV transmission line.

  • PDF

Investigation on Vibration Characteristics and Structural Reciprocity of Heunginjimun (흥인지문의 진동특성 및 상반성 분석)

  • Choi, Jae-Sung;Lee, Sung-Kyung;Min, Kyung-Won;Yoon, Weon-Kyu;Kim, Derk-Moon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.4
    • /
    • pp.338-347
    • /
    • 2010
  • Heunginjimun designated as a Treasure No.1 is a two-story wooden structure with 5 bay and 2 bay in its front and side views, respectively. This paper presents an investigation on vibration characteristics of Heunginjimun through both ambient vibration and impact hammer tests. Ambient vibration test was performed to identify the natural frequency of Heunginjimun from the spectrum analysis of time history. Impact hammer test was undertaken to find the frequency of Heunginjimun which is affected by the surrounding traffics and to verify the reciprocal principle for the wooden structural system. Ambient vibration test results of Heunginjimun showed that the natural frequencies in two principal axes 1.5 Hz and 1.1 Hz, respectively. It was confirmed from impact hammer tests for a ground that the frequency of 4.2 Hz is caused by the traffics surrounding Heunginjimun. It was also observed that from the impact hammer test results between two locations in Heunginjimun that the transfer functions measured from two corresponding locations coincided well with each other. This result shows that the wooden structural system is globally linear, and the reciprocal principle is established.