• Title/Summary/Keyword: Impact Tester

Search Result 118, Processing Time 0.028 seconds

Forest Soil Characteristics and their Effects on the Trafficability of Logging Vehicles (산림토양(山林土壤) 특성(特性)이 집재차량(集材車輛)의 주행성(走行性)에 미치는 영향(影響))

  • Kim, Ki Weon
    • Journal of Korean Society of Forest Science
    • /
    • v.88 no.2
    • /
    • pp.255-265
    • /
    • 1999
  • This study deals with forest soil characteristics and their effects on the trafficability of logging vehicles. The study area is the national experimental forest located in Kwangnung. This site has 20m length and is equally divided by 5 surveying ranges with 4m width, on which a tractor(FIATAGRI) attached with logging boogie can drive in 4 driving types, namely 1time-return unload, 1time-return with load of 780-790kg weight of 3 logs, 5 and 10times-return with same load. After one driving type on all surveying ranges, the soil hardness is surveyed 5 times with 3 several type tools, SHM-1 type, lang penetrometer(L-PNTM), and clegg impact soil tester(CIST). A disturbed degree of cover vegetation and sliding conditions of vehicle are also observed. As results, the soil type of the test site was SC by USCS and dry brown forest soil. The cover vegetation is gotten trambled under driving after 3-5 times-return, shrubs leaves are fully fallen and their bark are peeled, and after 10 times-return the cover vegetations were nearly disappeared. The test vehicle has neither slided nor was overthrown. The wheel tracks in the 1-3 ranges, of which unit weight(gd, gt) is high and soil moisture content(MC) is low, were only 1-2cm deep, but those in the 4-5 ranges, of which the gd, gt is low and the MC is high, were 5-7cm deep. In the soil hardness test, which was established in 5 test ranges by types of driving, the more driving times, the higher the hardness. The soil hardness surveyed by L-PNTM has changed slowly and that surveyed by SHM-1 type has risen sharply. In the ranges with higher specific gravity(Gs), higher unit weight, lower MC and higher liquid limit(LL) and plasticity index(PI) was the soil hardness high and the trafficability was good. In the ranges with opposite conditions, also in the ranges of the lower soil hardness, the trafficability must be not good, because the wheel track may be deep. The results from CIST attached with 4kg hammer was not better than expected. So it is recommended to use CIST with 2.5kg or 0.5kg hammer.

  • PDF

A Study on the Distribution of Underground Plant Biomass and its Effect on the Stream Bank Stability (농촌 소 하천 제방 상의 식물 근계 분포 현황에 따른 제방 지지 역할에 관한 연구 - 경남 진주시 농촌 소하천 유역의 대나무와 잔디를 대상으로 -)

  • Lee, Chun-Seok;Kim, Jung-Uk
    • Journal of Korean Society of Rural Planning
    • /
    • v.5 no.1 s.9
    • /
    • pp.95-103
    • /
    • 1999
  • The purpose of this study is to find out the distribution of underground biomass and its soil stabilizing effects. Bamboo and grass were examined and compared. 1. Thirty 'soil & root' samples were collected to the depth of 30cm with Impact-corer, and then divided into three sections(0-10cm, 10-20cm, 20-30cm). Each piece had a volume of $950cm^3$ and the underground biomass was separated from the soil particles by washing with flowing water. The average underground biomass rates of bamboo and grass were 10.8% and 4% of each sample, respectively. The rate of grass root biomass declined with depth, but the bamboo root biomass was at peak at around 20cm depth. 2. The shear strength was measured with con-penetration tester at each sample collecting site. Three measurements were made at each depth(0-10cm, 10-20cm, 20-30cm) and were compared with the impact counts needed to insert the corer to the depth of 30cm. The shear strength has clear correlations with underground biomass. The more underground biomass, the higher shear strength. The shear strength of bamboo was about three times larger than the grass.

  • PDF

A Study on Morphology and Mechanical Properties of Biodegradable Polymer Nanocomposites (생분해성 고분자 나노복합체의 형태학 및 기계적 특성 연구)

  • Jang, Sang Hee
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.401-409
    • /
    • 2013
  • BBiodegradable polymers have attracted great attention because of the increased environmental pollution by waste plastics. In this study, PLA (polylactic acid)/Clay-20 (Cloisite 20) and PLA (polylactic acid)/PBS (poly(butylene succinate)/Clay-20 (Cloisite 20) nanocomposites were manufactured in a twin-screw extruder. Specimens for mechanical properties of PLA/Clay-20 and PLA/PBS (90/10)/Clay-20 nanocomposites were prepared by injection molding. Thermal, mechanical, morphological and raman spectral properties of two nanocomposites were investigated by differential scanning calorimetry (DSC), tensile tester, scanning electron microscopy (SEM) and raman-microscope spectrophotometer, respectively. In addition, hydrolytic degradation properties of two nanocomposites were investigated by hydrolytic degradation test. It was confirmed that the crystallinity of PLA/Clay-20 and PLA/PBS/Clay-20 nanocomposite was increased with increasing Clay-20 content and the Clay-20 is miscible with PLA and PLA/PBS resin from DSC and SEM results. Tensile strength of two nanocomposites was decreased, but thier elongation, impact strength, tensile modulus and flexural modulus were increased with an increase of Clay-20 content. The impact strength of PLA/Clay-20 and PLA/PBS/Clay-20 nanocomposites with 5 wt% of Clay-20 content was increased above twice than that of pure PLA and PLA/PBS (90/10). The hydrolytic degradation rate of PLA/Clay-20 nanocomposite with 3 wt% of Clay-20 content was accelerated about twice than that of pure PLA. The reason is that degradation may occur in the PLA and Clay-20 interface easily because of hydrophilic property of organic Clay-20. It was confirmed that a proper amount of Clay-20 can improve the mechanical properties of PLA and can control biodegradable property of PLA.

Effects of Blend Composition and Compatibilizer on the Mechanical Properties of Polypropylene/Acrylonitrile-Butadiene-Styrene Blends (블렌드 조성과 상용화제가 폴리프로필렌/ABS 블렌드의 기계적 물성에 미치는 영향)

  • Park, Jung-Hoon;Sung, Yu-Taek;Kim, Woo-Nyon;Hong, John-Hee;Hong, Byeong-Kwon;Yoo, Tae-Wook;Yoon, Ho-Gyu
    • Polymer(Korea)
    • /
    • v.29 no.1
    • /
    • pp.19-24
    • /
    • 2005
  • Polymer blends containing polypropylene (PP) with compatibilizers were prepared using twin screw extruder. Physical properties were investigated using universal test machine (UTM) and Izod impact tester. In the PP/acrylonitrilebutadiene-styrene (ABS) blends, mechanical strength was increased with the addition of PP-g-styrene acryloritrile (PP-g-SAN) compatibilizer, and the ductility was increased with the addition of ethylene-ethyl acrylate-maleic anhydride (E-EAMAH-g-SAN) compatibilizer. For the PP/ABS/ polycarbonate (PC)/Nylon-6,6 blends, impact strength was increased with the addition of ethylene glycidylmethacrylate (E-GMA compatibilizer) up to 0.5 phr. In the case of the PP/ABS/PC/Nylon-6,6/poly(methyl methacrylate) (PMMA)/poly(oxymethylene) (POM)/poly(vinyl acetate) (PVC)/poly(butylene terephthalate) (PBT) blends, mechanical properties were increased by the complex compatibilizing effects of PP-g-SAN, E-EA-MAH-g-SAN and E-GMA, respectively.

A analysis of friction relation between tennis outsole and tennis playing surfaces (테니스화겉창과 테니스 스포츠바닥재간의 마찰관계상관 분석)

  • Kim, Jung-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.361-380
    • /
    • 2002
  • The purposes of this study were to a analysis of friction relation between tennis outsole and tennis playing surfaces. Tennis footwear is an important component of tennis game equipment. It can support or damage players performance and comfort. Most importantly athletic shoes protect the foot preventing abrasions and injuries. Footwear stability in court sports like tennis is incredibly important since it is estimated that as many as 45% of all lower extremity injuries occur in the foot and ankle. The friction force is the force exerted by a surface as an object moves across it or makes an effort to move across it. The friction force opposes the motion of the object. Friction results when two surfaces are pressed together closely, causing attractive intermolecular forces between the molecules of the two different surfaces. The outsole provides traction and reduces wear on the midsole. Today's outsoles address sport specific movements (running versus pivoting) and playing surface types. Different areas of the outsole are designed for the distinct frictional needs of specific movements. Traction created by the friction between the outsole and the surface allows the shoe to grip the surface. As surfaces, conditions and player motion change, traction may need to vary. An athletic shoe needs to grip well when running but not when pivoting. Laboratory tests have demonstrated force reductions compared to impact on concrete. There is a correlation between pain, injury and surface hardness. These are a variety of traction patterns on the soles of athletic shoes. Traction like any other shoe characteristic must be commensurate and balanced with the sport. The equal and opposite force does not necessarily travel back up your leg. The surface itself absorbs a portion of the force converting it to other forms of energy. Subsequently, tennis court surfaces are rated not only for pace but also for the percentage of force reduction.

Study on the Safety of Playground Flooring Made of Polyolefin Foam Waste and Rubber Paving (폐폴리올레핀 폼과 탄성 포장재로 구성된 어린이 놀이터 바닥의 안전성에 관한 실험적 연구)

  • Choi, Soo-Kyung;Jun, Myoung-Hoon;Lee, Do-Heun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.246-254
    • /
    • 2013
  • This study is purposed to verify the safety of the floor of the children's playground using polyolefin foam waste and rubber paving. The critical fall height, walking suitability, long term physical fatigue expectation and slipperiness were tested. Polyolefin foam wastes in thickness of 30mm, 50mm and 70mm were prepared with paving the rubber paving materials in 12mm and 15mm thickness respectively. The test on the critical fall height was carried out according to KS G 5758:2009. The floor hardness test equipment (O-Y HMA) was used for the test on hardness of the floor from a viewpoint of walking suitability and fatigue. A portable slipperiness tester (ONO PPSM) was used for slipperiness test. It was revealed from the test that the floor made of the polyolefin foam waste and rubber paving were considerably safe from a viewpoint of impact absorption. With regards to the hardness of the floor, it was shown the excellent performance in the aspects of walking and fatigue for male. But it was not suitable with walking on the shoes(middle heels) for female. And they will be very fatigue if they were in a long time walking or standing. As far as the slipperiness is concerned, it was shown that it was comparatively safe for the ordinary motions even though the surface was wet.

A STUDY ON THE RESISTANCE OF WEAR AND CYTOTOXICITY OF THE TITANIUM SURFACE AFTER FILM DEPOSITIONS (박막증착시 티타늄 표면의 마손저항도와 세포독성에 관한 연구)

  • Kim Hyung-Woo;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.84-95
    • /
    • 2001
  • Titanium is widely used in dentistry for its low density, high strength, fatigue resistance, corrosion resistance, and biocompatibility. But it has a tendency of surface damage under circumstance of friction and impact for its low hardness of the surface. Coating is one of methods fir increasing surface hardness. Its effect is to improve surface physical characteristics without change of titanium. Diamond-like carbon and titanium nitride are known for its high hardness of the surface. So that this study was aimed at the wear test and the cytotoxicity test of the commercially pure titanium and Ti-6Al-4V alloy which were deposited by diamond-like carbon film or titanium nitride film to acertain improvement of the surface hardness and the biocompatibility. A disk (25mm diameter, 2mm thickness) was made of commercially pure titanium and Ti-6Al-4V alloy and these substrates were deposited by diamond-like carbon film or titanium nitride film. Diamond-like carbon film was deposited by the method of radiofrequency plasma assisted chemical vapor deposition and titanium nitride film was deposited by the method of reactive arc ion plating. Then these substrates were tested about wear characteristics by the pin-on-disk type wear tester in which ruby ball was used as a wear causer under the load of 32N, The fracture cycles were measured by rotating the substrates until their films were fractured. The wear volume was measured after 150 cycles and 3,000 cycles using surface profiler. The cytotoxicity test was peformed by the method of the MTT assay. The results were as follows : 1. In the results of the wear volume test, commercially pure titanium and titanium alloy which were coated by diamond-like carbon film or titanium nitride aim had higher resistance against wear than the substrates which were not coated by any films (P<0.05). 2. In the results of the fracture cycle test and the wear volume test, diamond-like carbon film had higher resistance against wear than titanium nitride film (P<0.05). 3. In both coatings of diamond-like carbon aim and titanium nitride film, Ti-6Al-4V alloy had higher resistance against wear than commercially pure titanium (P<0.05) 4. In the results of the cytotoxicity test, diamond-like carbon film and titanium nitride film had little cytotoxicity as like commercially pure titanium or Ti-6Al-4V alloy (P>0.05).

  • PDF

Bone-Preserving Decompression Procedures Have a Minor Effect on the Flexibility of the Lumbar Spine

  • Costa, Francesco;Ottardi, Claudia;Volkheimer, David;Ortolina, Alessandro;Bassani, Tito;Wilke, Hans-Joachim;Galbusera, Fabio
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.6
    • /
    • pp.680-688
    • /
    • 2018
  • Objective : To mitigate the risk of iatrogenic instability, new posterior decompression techniques able to preserve musculoskeletal structures have been introduced but never extensively investigated from a biomechanical point of view. This study was aimed to investigate the impact on spinal flexibility caused by a unilateral laminotomy for bilateral decompression, in comparison to the intact condition and a laminectomy with preservation of a bony bridge at the vertebral arch. Secondary aims were to investigate the biomechanical effects of two-level decompression and the quantification of the restoration of stability after posterior fixation. Methods : A universal spine tester was used to measure the flexibility of six L2-L5 human spine specimens in intact conditions and after decompression and fixation surgeries. An incremental damage protocol was applied : 1) unilateral laminotomy for bilateral decompression at L3-L4; 2) on three specimens, the unilateral laminotomy was extended to L4-L5; 3) laminectomy with preservation of a bony bridge at the vertebral arch (at L3-L4 in the first three specimens and at L4-L5 in the rest); and 4) pedicle screw fixation at the involved levels. Results : Unilateral laminotomy for bilateral decompression had a minor influence on the lumbar flexibility. In flexion-extension, the median range of motion increased by 8%. The bone-preserving laminectomy did not cause major changes in spinal flexibility. Two-level decompression approximately induced a twofold destabilization compared to the single-level treatment, with greater effect on the lower level. Posterior fixation reduced the flexibility to values lower than in the intact conditions in all cases. Conclusion : In vitro testing of human lumbar specimens revealed that unilateral laminotomy for bilateral decompression and bone-preserving laminectomy induced a minor destabilization at the operated level. In absence of other pathological factors (e.g., clinical instability, spondylolisthesis), both techniques appear to be safe from a biomechanical point of view.