• Title/Summary/Keyword: Immersion Assessment

Search Result 46, Processing Time 0.048 seconds

Proposal on Immersion Assessment of Interactive Art (인터랙티브 아트에서의 몰입측정 방법 제안)

  • Lee, MyounJae;Kim, Kyoung-Nam
    • Journal of Digital Convergence
    • /
    • v.12 no.9
    • /
    • pp.353-358
    • /
    • 2014
  • Interactive art is implemented by participants interaction, characterized by the virtuality, immersion, interactivity. Among these features, immersion is important factor to absorb in the interactive art. From now, Interactive art measurement methods are mainly used in interview, questionnaire, and physiological methods. But these methods are difficult to measure the exact immersion, can give interfere with viewer's participation in the interactive art. In this paper, we propose the immersion measurement method which based on participant's moving lines, observation time with mobile devices, camera. This paper can help to analyse degree of immersion on interactive art.

Electrical Characteristics Test of Distribution Polymer Lightening Arresters (배전용 폴리머 피뢰기의 전기적 특성시험)

  • Kwon, Tae-Ho;Lee, Byung-Sung;Song, Il-Keun;Kim, Dong-Myung;Yoon, Tae-Sang;Jung, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.546-549
    • /
    • 2004
  • This paper describes the electrical characteristics of the polymer lightning arresters(L.As) used to protect distribution lines and power facilities from surge. For the relative comparison, the characteristics assessment was done for 2 states of L.As before and after water immersion treatment. The L.As for the comparative test were immersed with water of $95[^{\circ}C]$ considered a severe condition. After the immersion treatment, the assessment was carried out for material analyses in chemical structure(FTIR : fourier transform infrared spectrophotometer). Electrical performance measured insulation resistance measurement, leakage current measurement, critical operation voltage measurement etc.. In addition to, the results were compared with those for the L.As deteriorated in the field. Thus, the accelerative deterioration degree of polymer materials by immersion treatment was evaluated, by which the structural defects of the polymer L.As could be inferred.

  • PDF

Uncertainty assessment of industrial platinum resistance thermometers for different lead-wire connection methods (산업용 백금저항온도센서의 결선방식에 따른 측정불확도 평가방법)

  • Kim, Yong-Gyoo;Gam, Kee-Sool;Yang, In-Seok
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.322-326
    • /
    • 2009
  • To estimate the measurement uncertainty for industrial platinum resistance thermometers(IPRTs) made with 3-wire connection, the immersion temperature profile was investigated using a liquid bath. Two types of IPRTs having lead wires made of silver and nickel were constructed and the immersion profiles were measured at temperatures from -50 $^{\circ}C$ to 250 $^{\circ}C$ using 3-wire and 4-wire method. As immersion depth and temperature increased, the resistances measured by 3-wire method increased linearly but not for 4-wire method. To calibrate a 3-wire IPRT, the immersion effect must be accounted for. We propose a linear equation to assess correctly the measurement uncertainty.

Comparison of Flooding Tolerance for the Selection of Plants in Vegetation-Based Low Impact Development Facilities (식생기반형 LID 시설의 식재식물 선정을 위한 내침수성 비교)

  • Lee, Eun-Yeob;Hyun, Kyoung-Hak;Hou, Jin-Sung;Park, Mi-Ok;Koo, Bon-Hak
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.6
    • /
    • pp.466-476
    • /
    • 2014
  • In this study, 10 species of plants with high adaptability to aquatic environments were compared for selecting plant species suitable for vegetation-based low impact development (LID) facilities. The flooding tolerances of the plants were tested by analyzing their growth status under half-immersion and full-immersion conditions, with varying durations of immersion. In decreasing order of flooding tolerance, the comparative analysis of plant height and leaf width is as follows: Hemerocallis fulva, Juncus effusus var. decipiens, Iris pseudoacorus, Phragmites communis TRIN, Typha orientalis C.Presl, Aster koraiensis Nakai, Iris sanguinea, Equisetum hyemale, Acorus calamus. Specifically, Hemerocallis fulva, Juncus effusus var. decipiens. Iris pseudoacorus showed excellent growth status under both immersion conditions. Iris sanguinea and Equisetum hyemale. withered to death by around day 27 of the experiment, but their flooding tolerance was confirmed to be relatively high. Iris pseudoacoru showed flooding tolerance under the half-immersion condition unlike under the full-immersion condition, when compared on day 21 of the experiment. Aster koraiensis Nakai also thrived better under the half-immersion condition, proving to be a highly immersion-resistant species. On the basis of the results of this experiment, Hemerocallis fulva, Juncus effusus var. decipiens and Iris pseudoacorus, Typha orientalis C.Presl were selected as species suitable for vegetation-based LID facilities.

Effectiveness of Learning Performances According to Financial Motivation of University Students

  • PARK, Young-Sool;KWON, Lee-Seung;CHOI, Eun-Mee
    • Asian Journal of Business Environment
    • /
    • v.9 no.3
    • /
    • pp.27-38
    • /
    • 2019
  • Purpose - The aim of this study is to explore the effectiveness in educational differences between students of the government's financial-funded groups and the non-financial-funded groups at a university in Korea. Research design, data, and methodology - The study was conducted using a survey tool of National Assessment for Student Engagement in Learning. In total, 334 participants were surveyed, of which 290 students were participants in economic support program and 44 were nonattendance program students. The general characteristics of all of the participants were investigated by frequency analysis. The analysis of participants' collective characteristics used independent t and f-test, and one-way ANOVA with IBM SPSS Statistics package program 22.0. Results - The number of participating students is higher than that of non-participating students in relation to in-activities of university immersion, but the number of participating students is lower than that of non-participating students in relation to in-quality of student support. However, there was no statistical significance. The confidence coefficient of the university-immersion and student support questionnaire is 0.860 and 0.913, respectively. Conclusions - There is no significant difference in the activities of university immersion and student support between students who participate in the economic support program and those who do not.

A Simulation Tool for Ultrasonic Inspection

  • Krishnamurthy, Adarsh;Mohan, K.V.;Karthikeyan, Soumya;Krishnamurthy, C.V.;Balasubramaniam, Krishnan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.3
    • /
    • pp.153-161
    • /
    • 2006
  • A simulation program SIMULTSONIC is under development at CNDE to help determine and/or help optimize ultrasonic probe locations for inspection of complex components. SIMULTSONIC provides a ray-trace based assessment for immersion and contact modes of inspection. The code written in Visual C++ operating in Microsoft Windows environment provides an interactive user interface. In this paper, a description of the various features of SIMULTSONIC is given followed by examples illustrating the capability of SIMULTSONIC to deal with inspection of canonical objects such as pipes. In particular, the use of SIMULTSONIC in the inspection of very thin-walled pipes (with 450 urn wall thickness) is described. Ray trace based assessment was done using SIMULTSONIC to determine the standoff distance and the angle of oblique incidence for an immersion mode focused transducer. A 3-cycle Hanning window pulse was chosen for simulations. Experiments were carried out to validate the simulations. The A-scans and the associated B-Scan images obtained through simulations show good correlation with experimental results, both with the arrival time of the signal as well as with the signal amplitudes.

Comparison of instrumental methods for color change assessment of Giomer resins

  • Luiza de Almeida Queiroz Ferreira;Rogeli Tiburcio Ribeiro da Cunha Peixoto ;Claudia Silami de Magalhaes;Tassiana Melo Sa;Monica Yamauti ;Francisca Daniele Moreira Jardilino
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.8.1-8.9
    • /
    • 2022
  • Objectives: The aim of this study was to compare the color change of the Giomer resin composite (Beautifil-Bulk) by using photographs obtained with a smartphone (iPhone 6S) associated with Adobe Photoshop software (digital method), with the spectrophotometric method (Vita Easyshade) after immersion in different pigment solutions. Materials and Methods: Twenty resin composite samples with a diameter of 15.0 mm and thickness of 1.0 mm were confectioned in A2 color (n = 5). Photographs and initial color readings were performed with a smartphone and spectrophotometer, respectively. Then, samples were randomly divided and subjected to cycles of immersion in distilled water (control), açai, Coke, and tomato sauce, 3 times a day, 20 minutes for 7 days. Later, new photographs and color readings were taken. Results: The analysis (2-way analysis of variance, Holm-Sidak, p < 0.05) demonstrated no statistical difference (p < 0.005) between the methods in all groups. Similar color changes were observed for all pigment solutions when using the spectrophotometric method. For the digital method, all color changes were clinically unacceptable, with distilled water and tomato sauce similar to each other and with statistical differences (p < 0.005) for Coke and açai. Conclusions: Only the tomato sauce produced a color change above the acceptability threshold using both methods of color assessment. The spectrophotometric and digital methods produce different patterns of color change. According to our results, the spectrophotometric method is more recommended in color change assessment.

Effect of Passing Aged Years and Coating Thickness on Corrosion Properties of Reinforcing Steel in Mortar (W/C:0.5) (모르타르(W/C:0.5)내의 철근의 부식 특성에 미치는 재령 년수와 피복두께의 영향)

  • Moon, Kyung-Man;Lee, Sung-Yul;Jeong, Jin-A;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Corrosion Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.99-105
    • /
    • 2015
  • The structures of reinforced concrete have been extensively increased with rapid development of industrial society. Futhermore, these reinforced concretes are easy to expose to severe corrosive environments such as seawater, contaminated water, acid rain and seashore etc.. Thus, corrosion problem of steel bar embedded in concrete is very important in terms of safety and economical point of view. In this study, specimens having six different coating thickness (W/C:0.5) were prepared and immersed in flowing seawater for five years to evaluate the effect of coating thickness and immersion time on corrosion property. The polarization characteristics of these embedded steel bars were investigated using electrochemical methods such as corrosion potential, anodic polarization curve, and impedance. At the 20-day immersion, the corrosion potentials exhibited increasingly nobler values with coating thickness. However, after 5-yr. immersion their values were shifted in the negative direction, and the relationship between corrosion potential and coating thickness was not shown. Although 5-yr. immersion lowered corrosion potential, 5-yr. immersion did not increase corrosion rate. In addition, after 5-yr. immersion, the thinner cover thickness, corrosion current density was decreased with thinning coating thickness. It is due to the fact that ease incorporation of water, dissolved oxygen and chloride ion into a steel surface caused corrosion and hence, leaded to the formation of corrosion product. The corrosion product plays the role as a corrosion barrier and increases polarization resistance. The corrosion probability evaluated depending on corrosion potential may not be a good method for predicting corrosion probability. Hence, the parameters including cover thickness and passed aged years as well as corrosion potential is suggested to be considered for better assessment of corrosion probability of reinforced steel exposed to partially or fully in marine environment for long years.

Implementation of Background Scene in the Virtual Reality Ship Simulator (가상현실 선박 시뮬레이터의 배경 구현)

  • 임정빈
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.6 no.1
    • /
    • pp.11-22
    • /
    • 2000
  • The paper describes creation methods of background scenes to implement realistic virtual environments in the VRSS (Virtual Reality Ship Simulator). VRSS is next-generation system constructed with virtual tools in a virtual space. Thus, it could have many benefits compared to conventional ship simulators composed with heavy bridge mock-up system and wide visual presentations. In this work, we developed effective 3D object modeling techniques, and constructed virtual harbor scene by using 3D-Webmaster authoring tool. The virtual harbor was built with object-oriented 3D objects modeled to interact with user's action. With the immersion-type VR system, we created virtual harbor environments in a virtual space, and discussed on the naturalness of the scene with test results of SDMPA (Semantic Differential Method for Psychophysical Assessment) by 10 subjects. As the results of subject assessment, all of the participants could felt natural-like harbor. Therefore, we found that the proposed creation methods and procedures of background scene are enabling to fit to the full mission VRSS construction.

  • PDF

Utilization of Immersion-Drying Method for Measuring Damage Depth of Fire-Damaged High-Strength Concrete (화재로 손상된 고강도 콘크리트의 손상 깊이 측정을 위한 수중침지 건조방법의 활용)

  • Kim, Jong;Lim Gun-Su;Beak, Seung-Bok;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.3
    • /
    • pp.297-308
    • /
    • 2024
  • This study presents a novel approach for evaluating fire-induced damage depth in concrete. The methodology leverages the principle that exposure to high temperatures causes internal expansion within concrete, leading to increased voids and microcracks in the damaged zones. This heightened porosity results in greater absorption rates compared to undamaged areas. By immersing fire-damaged concrete samples in water and subsequently monitoring the drying process, the depth of damage can be assessed. Differences in drying rates and color variations between damaged and undamaged areas serve as visual indicators for determining the extent of the damage. Experimental results from this water immersion method revealed damage depths of 38.7mm and 37.5mm for two different concrete mixtures. These measurements notably surpass the damage depths estimated using traditional phenolphthalein-based methods. This discrepancy suggests that utilizing the absorption rate principle, which is directly linked to the physical changes caused by thermal expansion, offers a more accurate and sensitive assessment of fire damage depth compared to methods relying solely on the presence of Portlandite for colorimetric indication.