• Title/Summary/Keyword: Immersion angle

Search Result 82, Processing Time 0.028 seconds

Development of 3D Stereoscopic Image Generation System Using Real-time Preview Function in 3D Modeling Tools

  • Yun, Chang-Ok;Yun, Tae-Soo;Lee, Dong-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.6
    • /
    • pp.746-754
    • /
    • 2008
  • A 3D stereoscopic image is generated by interdigitating every scene with video editing tools that are rendered by two cameras' views in 3D modeling tools, like Autodesk MAX(R) and Autodesk MAYA(R). However, the depth of object from a static scene and the continuous stereo effect in the view of transformation, are not represented in a natural method. This is because after choosing the settings of arbitrary angle of convergence and the distance between the modeling and those two cameras, the user needs to render the view from both cameras. So, the user needs a process of controlling the camera's interval and rendering repetitively, which takes too much time. Therefore, in this paper, we will propose the 3D stereoscopic image editing system for solving such problems as well as exposing the system's inherent limitations. We can generate the view of two cameras and can confirm the stereo effect in real-time on 3D modeling tools. Then, we can intuitively determine immersion of 3D stereoscopic image in real-time, by using the 3D stereoscopic image preview function.

  • PDF

Enhancement of hydrophilicity and anti-fouling property of polysulfone membrane using amphiphilic nanocellulose as hydrophilic modifier

  • Yang, Xue;Liu, Lifang;Jiang, Shuai
    • Membrane and Water Treatment
    • /
    • v.10 no.6
    • /
    • pp.461-469
    • /
    • 2019
  • In the present work, we present a new effective hydrophilicity modifier for polysulfone (PSf) membrane. Firstly, amphiphilic nanocellulose (ANC) with different substitution degrees (SD) was synthesized by esterification reaction with nanocellulose (NC) and dodecyl succinic anhydride (DDSA). The SD and morphology of ANC were characterized by titration method and transmission electron microscopy (TEM). Then, the polysulfone (PSf)/ANC blend membranes were prepared via an immersion phase inversion method. The influence of SD on the morphology, structure and performances of PSf/ANC blend membrane were carefully investigated by Fourier transform infrared spectroscopy (FTIR), scanning electron microscope (SEM), mechanical property test, contact angle measuring instrument and filtration experiment. The results showed that the mechanical property, hydrophilicity and anti-fouling property of all the PSf/ANC blend membranes were higher than those of pure PSf membrane and PSf/NC membrane, and the membrane properties were increased with the increasing of SD values. As ANC-4 has the highest SD value, PSf/ANC-4 membrane exhibited the optimal membrane properties. In conclusion, the prepared ANC can be used as an additive to improve the hydrophilicity and anti-fouling properties of polysulfone (PSf) membrane.

A STUDY ON THE MARGINAL LEAKAGE OF RESTORATIONS WITH DIFFERENT CAVOSURFACE MARGINS (와연형태(窩緣形態)에 따른 와연누출(邊緣漏出)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Shin, Han-Ju;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.119-129
    • /
    • 1986
  • The purpose of this study was to evaluate the marginal leakage of glass ionomer cement with different cavosurface margins. 192 class V cavities were prepared on freshly extracted non-carious teeth and glass ionomer cement were inserted according to the manufacturer's instructions. Cavity preparations for this investigation were performed in four groups. The experimental specimens were made by packing the glass ionomer cement (Fuji Ionomer Type II G-C Co. Japan) into the prepared 192 cavities of four groups with different modes: Group I. - The 48 cavities with $90^{\circ}$ butt-joint cavosurface preparation and restored with glass ionomer cement. Group II. - The 48 cavities with butt-joint preparation modified by $135^{\circ}$ beveling the cavosurface in the dentin and restored with glass ionomer cement. Group III. - The 48 cavities with butt-joint preparation modified by cutting a chamfer in the dentin and restored with glass ionomer cement. Group IV. - The same 48 cavities as group I, and overfilled with glass ionomer cement beyond the cavosurface angle. And four groups above described divided into three subgroups by means of conditioning the cavity walls: Control group. - Glass ionomer cement filled in the prepared 64 cavities after being cleaned with a stream of tap water. Phosphoric acid treatment group. - Glass ionomer cement filled in the prepared 64 cavities after being conditioned with a 50% phosphoric acid. Citric acid treatment group. - Glass ionomer cement filled in the prepared 64 cavities after being conditioned with a 50% citric acid. All 192 specimens were immersed in the 2.0% basic fuchsin solution and subjected to thermal stress at one-minute intervals ($4{\pm}2^{\circ}C$ to $60{\pm}2^{\circ}C$) for 70 minutes before exposure to the dye. The specimens were sectioned ecclesiologically through the center of the restorations for different periods of immersion time, 24 hours, 7 days, 14 days 30 days. The sections were examined under a stereoscopic microscope. The results were as follows: 1. The degree of marginal leakage in group II and III was greater than that in group I and IV. 2. The degree of marginal leakage in phosphoric acid treatment group was similar with that in control group. 3. The degree of marginal leakage in citric acid treatment group was less than that in control group. 4. In all groups, the degree of marginal leakage in phosphoric acid treatment group was greater than that in citric acid treatment group. 5. There is no statistical difference of the degree of marginal leakage according to the immersion time in the dye solution.

  • PDF

A Study of the Acoustic Microscope System by Large Aperture Probe (대구경 탐촉자를 이용한 초음파 현미경 시스템 연구)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.5
    • /
    • pp.475-479
    • /
    • 2003
  • Traditional ultrasonic evaluation to detect micro/small surface cracks is the pulse-echo technique using the normal immersion transducer with high frequency, or the angle beam transducer with surface wave. It is difficult to make the automatic ultrasonic system that is to detect micro and small surface crack and position on the large structure like steel and ceramic rolls, because of the huge data of inspection and the ambiguous position data of transducer. The aim of this study using the high precision scanning acoustic microscope with 10MHz large aperture transducer was to display the real time A, B, C-scan for the automatic ultrasonic system in order to detect the existence and position of surface crack. The ultrasonic method with large aperture transducer was improved the scanning time and speed over 10times faster than traditional methods.

Microbe Adhesion and Organic Removal from Synthetic Wastewater Treatment using Polypropylene Media Modified by Ion-Assisted Reactions (이온 보조 반응에 의하여 활성화된 폴리프로필렌 담체를 이용만 합성폐수 처리시 미생물 부착 및 유기물의 제거)

  • Seon, Yong-Ho;Han, Sung;Koh, Seok-Keun
    • KSBB Journal
    • /
    • v.17 no.3
    • /
    • pp.235-240
    • /
    • 2002
  • The surface of polypropylene was modified by 1 keV $Ar^+$ ion beam in an $O_2$ environment in order to enhance wettability. Contact angle of deionized water on modified polypropylene was reduced from $78^{\circ}$to $22^{\circ}$. The enhanced wettability is originated from newly formed functional groups such as ether, carbonyl, and carbonyl groups. During immersion in deionized water, the enhanced wettability has remained nearly same. After washing in water, the hydrophilic functional groups on the polymer surface have been very stable. The modified polypropylene was adopted as bio-film media to remove organics in synthetic wastewater. Microbe adhesion on the polypropylene surface was improved due to the newly formed hydrophilic groups.

Evaluation of the Surface Crack by a Large Aperture Ultrasonic Probe (대구경 초음파 탐촉자를 이용한 표면균열 평가)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.180-185
    • /
    • 2004
  • Conventional ultrasonic examination to detect micro and small surface cracks is based on the pulse-echo technique using a normal immersion focused transducer with high frequency, or an angle-beam transducer generating surface waves. It is difficult to make an automatic ultrasonic system that can detect micro and small surface cracks and position in a large structure like steel and ceramic rolls, because of the huge data of inspection and the ambiguous position data of the transducer. In this study, a high-precision scanning acoustic microscope with a 10MHz large-aperture transducer has been used to assess the existence, position and depth of a surface crack from the real-time A, B, C scans obtained by exploiting the ultrasonic diffraction. The ultrasonic method with large aperture transducer has improved the accuracy of the crack depth assessment and also the scanning speed by ten times, compared with the conventional ultrasonic methods.

Formation of Hydrophobic Self-assembled Monolayers on Paper Surface with Silanes (실란화 반응에 의한 종이 표면의 소수성 자기조립 단분자막 형성)

  • Oh, Min-Jeong;Lee, Hyoung;Paik, Ki-Hyon
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.42 no.1
    • /
    • pp.64-73
    • /
    • 2010
  • This study was conducted to modify the surface properties of papers by formation of hydrophobic self-assembled monolayer(SAM) on paper surface with silanes. A base paper I(0.5% AKD) and base paper II(1.0-1.5% AKD) were reacted with silanes(PFDTES, DMDCS, MODDCS) by immersion method and vapor deposition method. Hydrophobic SAMs(contact angle value>$120^{\circ}C$) were obtained on all papers after treatment with $10^{\mu}l$ PFDTES for 15min, with $50^{\mu}l$ DMDCS for 30min, with $50^{\mu}l$ MODDCS for 300min. When applying PFDTES to paper surface, lower silane concentration and shorter reaction time were required, whereas MODDCS with long alkyl chain required the longest reaction time of 300min. The st$\ddot{o}$ckight sizing degree of silane treated papers were increased between 105sec(base paper I) and 130sec(base paper II). The wet tensile strength of PFDTES-treated base papers(I, II) increased by 10-34% after SAM formation. However, the wet tensile strength of the DMDCS-treated base paper(I) was found to decrease from 0.067kN/m to 0.038kN/m; this may due to the cellulose degrading as a result of generated hydrogen chloride when hydroxyl group of cellulose were reacted with DMDCS. No apparent changes of PPS roughness on silane-treated papers are observed. The ATR-IR spectrum showed absorption peak located at 465 and 1200cm-1 which can be assigned to the Si-O-C asymmetric stretching and Si-O-C bonds, respectively.

Enhanced performance of thin-film nanocomposite RO/NWF membrane by adding ZnO nanospheres in aqueous phase during interfacial polymerization process

  • Li, Hongbin;Shi, Wenying;Su, Yuheng;Hou, Hongxiang;Du, Qiyun;Zhang, Haixia;Qin, Xiaohong
    • Membrane and Water Treatment
    • /
    • v.8 no.3
    • /
    • pp.225-244
    • /
    • 2017
  • A novel thin-film nanocomposite (TFN) reverse osmosis (RO)/non-woven fabric (NWF) membrane was prepared by adding zinc oxide (ZnO) nanospheres ($30{\pm}10nm$) during the interfacial polymerization process of m-phenylenediamine (MPD) and trimesoyl chloride (TMC) on self-made polysulfone (PSF) membrane/polyester (PET) non-woven fabric support. The improved performance of TFN RO membrane was verified in terms of water contact angle (WCA), water flux, salt rejection, antifouling properties and chlorine resistance. The results showed that the WCA value of TFN RO surface had a continuous decrease with the increasing of ZnO content in MPD aqueous solution. The water flux of composite TFN RO membranes acquired a remarkable increase with a stable high solute rejection (94.5 %) in $1g{\cdot}L^{-1}$ NaCl aqueous solution under the optimized addition amount of ZnO (1 wt%). The continuous testing of membrane separation performance after the immersion in sodium hypochlorite solution indicated that the introduction of ZnO nanospheres also dramatically enhanced the antifouling properties and the chlorine resistance of composite RO membranes.

Corrosion Behavior of High Pressure Die Cast Al-Ni and Al-Ni-Ca Alloys in 3.5% NaCl Solution

  • Arthanari, Srinivasan;Jang, Jae Cheol;Shin, Kwang Seon
    • Corrosion Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.100-108
    • /
    • 2017
  • In this investigation corrosion behavior of newly developed high-pressure die cast Al-Ni (N15) and Al-Ni-Ca (NX1503) alloys was studied in 3.5% NaCl solution. The electrochemical corrosion behavior was evaluated using open circuit potential (OCP) measurement, potentiodynamic polarization, and electrochemical impedance spectroscopy (EIS) techniques. Potentiodynamic polarization results validated that NX1503 alloy exhibited lower corrosion current density ($i_{corr}$) value ($5.969{\mu}A/cm^2$) compared to N15 ($7.387{\mu}A/cm^2$). EIS-Bode plots revealed a higher impedance (${\mid}Z{\mid}$) value and maximum phase angle value for NX1503 than N15 alloy. Equivalent circuit curve fitting analysis revealed that surface layer ($R_1$) and charge transfer resistance ($R_{ct}$) values of NX1503 alloy was higher compared to N15 alloy. Immersion corrosion studies were also conducted for alloys using fishing line specimen arrangement to simultaneously measure corrosion rates from weight loss ($P_W$) and hydrogen volume ($P_H$) after 72 hours and NX1503 alloy had lower corrosion rate compared to N15 alloy. The addition of Ca to N15 alloy significantly reduced the Al3Ni intermetallic phase and further grain refinement may be attributed for reduction in the corrosion rate.

Analysis of Ultrasonic Scattering from Side-drilled Holes (원주형 기공에 대한 초음파 산란 해석)

  • Jeong, Hyun-Jo;Park, Moon-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.559-565
    • /
    • 2004
  • Two different methods were used for the scattering analysis of side-drilled holes(SDH). The scattering models include an explicit model based on the Kirchhoff approximation and the solution of the exact separation of variables. The far-field scattering amplitude was calculated and their time-domain results were compared for the case of shear vertical wave. The exact solution predicts the existence of the creeping wave. The Kirchhoff approximation agreed to the exact solution, except the case of the creeping wave. Two measurement models were introduced to predict the response from the SDHs for the case of immersion, pulse-echo testing. The received voltage was calculated for the case of the shear vertical waves with the incident angle of $45^{\circ}$ to the SDH with the diameter of 1mm, and compared with the experimental results.