• Title/Summary/Keyword: Immediate placement

Search Result 144, Processing Time 0.029 seconds

The socket shield technique and its complications, implant survival rate, and clinical outcomes: a systematic review

  • Stefano Oliva;Mario Capogreco;Giovanna Murmura;Ettore Lupi;Di Carlo Mariachiara;Maurizio D'Amario
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: The aim of this systematic review was to evaluate the effectiveness of the socket shield technique (SST), an innovative surgical method introduced in 2010, for reducing buccal bone plate resorption. Methods: The review was conducted following the PRISMA guidelines. Clinical studies conducted in humans and investigating the SST were searched on PubMed (MEDLINE), Embase, Web of Knowledge, and Google Scholar in November and December 2021. The implant survival rate, percentage of complications, and clinical parameters (marginal bone loss [MBL], pink esthetic score [PES], and buccal bone plate resorption [BBPR]) were analyzed using the collected data. Results: The initial search resulted in 132 articles. After article screening, the full texts of 19 studies were read and 17 articles were finally included in the review. In total, 656 implants were installed with the SST. Nine of the 656 implants experienced failure, resulting in an implant survival rate of 98.6%. The percentage of complications was about 3.81%. The analysis of clinical parameters (MBL, PES, and BBPR), showed favorable results for the SST. The mean MBL in implants placed with the SST was 0.39±0.28 mm versus 1.00±0.55 mm in those placed without the SST. PES had a better outcome in the SST group, with an average of 12.08±1.18 versus 10.77±0.74. BBPR had more favorable results in implants placed with the SST (0.32±0.10 mm) than in implants placed with the standard technique (1.05±0.18 mm). Conclusions: The SST could be considered beneficial for preserving the buccal bone plate. However, since only 7 of the included studies were long-term randomized controlled trials comparing the SST with the standard implant placement technique, the conclusions drawn from this systematic review should be interpreted with caution.

Clinical Comparison of Immediately Loaded and Delayed Loaded OSSTEM GS III Implant in Partially Edentulous Patients (자연치 부분 결손 환자에서 테이퍼 형태의 국산 임플란트(OSSTEM GS III)의 즉시하중 성공률에 대한 지연하중군과의 비교 임상연구)

  • Kwon, Min-Jung;Kim, Young-Kyun;Yeo, In-Sung;Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.267-275
    • /
    • 2011
  • This prospective study was designed to compare clinical outcomes of immediately loaded implant with delayed loaded implant in partially posterior edentulous patients. For test group, 42 GS III (Osstem, Korea) implants in 17 patients were loaded within 48 hours after the placement. Control group was 27 implants in 15 patients loaded at $2.6{\pm}1.7months$ from the placement surgery. Before loading, primary stability was evaluated by ISQ value. Clinical symptoms, mobility, soft tissue state was evaluated at baseline, 3 months, 6 months and 12 months of loading. Marginal bone level change was also measured with periapical radiographs. Mann-Whitney test (${\alpha}$=0.05) and repeated measured ANOVA (${\alpha}$=0.05) was used for marginal bone level change between two groups. At the baseline, mean ISQ value of test group and control group was $80.3{\pm}7.1$ and $69{\pm}17$ respectively. Test group showed 95.23% of success rate and 100% of control group was successful. At 3 and 6months of loading, significantly more bone resorption was observed in test group than in control group (p<0.05). However, there was no significant difference in the bone level change at 12months of loading between two groups (p>0.05). Marginal bone level change showed no significant difference with gender and location (p>0.05). Within the limitation of this study, when primary stability was obtained, immediate loading of GS III implant at posterior region could be predictable treatment option.

The influence of magnet on tissue healing after immediate implantation in fresh extraction sites in dogs (성견에서 발치 후 즉시 식립 임플란트에 설치한 자석이 주위 조직에 미치는 영향)

  • Yu, Seok-Min;Cho, In-Ho;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.435-444
    • /
    • 2009
  • Statement of problem: The clinical use of electric and electomagnetic fields for fracture healing applications began in the early 1970s. Since then, several technologies have been developed and shown to promote healing of fractures. Developments of these devices have been aided in recent years by basic research and several well controlled clinical trials not only in the medical field but in dentistry. Purpose: The purpose of this study was to compare alveolar bone reduction following immediate implantation using implants onto which magnets were attached in fresh extracted sockets. Material and methods: Four mongrel dogs were involved. Full buccal and lingual mucoperiosteal flaps were elevated and third and fourth premolars of the mandible were removed. Implants with magnets and implants without magnets were installed in the fresh extracted sockets and after 3 months of healing the animals were sacrificed. The mandibles were dissected and each implant sites were sampled and processed for histological examination. Results: The marginal gaps that were present between the implant and walls of the sockets at the implantation stage disappeared in both groups as a result of bone fill and resorption of the bone crest. The buccal bone crests were located apical of its lingual counterparts. At the 12 week interval the mean of marginal bone resorption in the control group was significantly higher than that of the magnet group. The majority of specimens in magnet group presented early bone formation and less resorption of the buccal marginal bone compared to the control group. Conclusion: Within the limitations of this study, it could be concluded that implants with magnets attached in the early stages of implantation may provide more favorable conditions for early bone formation and reduce resorption and remodeling of marginal bone.

ANTERIOR ESTHETIC IMPROVEMENT THROUGH ORTHODONTIC EXTRUSIVE REMODELING AND SINGLE-UNIT IMPLANTATION IN A FRACTURED UPPER LATERAL INCISOR WITH ALVEOLAR BONE LOSS: A CASE REPORT (치은연하 파절로 치조골 소실을 동반한 상악측절치에서 orthodontic extrusive remodeling후 임플란트 식립을 통한 심미수복: 증례보고)

  • Hwang, Soo-Youn;Shon, Won-Jun;Han, Young-Chul;Bae, Kwang-Shik;Back, Seung-Ho;Lee, Woo-Cheol;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.39-44
    • /
    • 2008
  • The treatment of esthetic areas with single-tooth implants represents a new challenge for the clinician. In 1993, a modification of the forced eruption technique, called "orthodontic extrusive remodelling," was proposed as a way to augment both soft- and hard-tissue profiles at potential implant sites. This case report describes augmentation of the coronal soft and hard tissues around a fractured maxillary lateral incisor associated with alveolar bone loss, which was achieved by forced orthodontic extrusion before implant placement. Through these procedures we could reconstruct esthetics and function in a hopeless tooth diagnosed with subgingival root fracture by trauma.

Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design (테이퍼드 직선형 SLA 임플란트의 안정성 평가)

  • Kim, Yong-Gun;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.80-88
    • /
    • 2018
  • Purpose: Implant surface modification and implant design are the principle targets for achieving successful primary stability. The aim of this study was to measure implant stability quotient (ISQ) values of sandblasted, large-grit, acid-etched (SLA) implants with tapered straight body design during the healing period, and to determine the various factors affecting implant stability. Materials and Methods: To measure implant stability, resonance frequency analysis (RFA) was performed in 26 patients (13 women and 13 men) with 44 SLA implants with tapered straight body design. Implant stability (ISQ values) was evaluated at baseline and healing abutment connection (12 weeks), and the correlations between RFA and insertion torque (IT), bone quality, and jawbone were determined. Results: The mean ISQ value of the implants was $69.4{\pm}10.2$ at the time of implant placement (baseline) and $81.4{\pm}6.9$ at the time of healing abutment connection (P < 0.05). Significant differences were found between RFA and bone quality and between RFA and jawbone (P < 0.05). No significant differences were found between RFA and IT, insertion area, fixture diameter, and implant length (P > 0.05). Conclusion: ISQ values of SLA implants with tapered straight body design were high at baseline and healing abutment connection. It was concluded that SLA implants with tapered straight body design show improved primary and secondary stability, and that immediate or early loading may be applicable.

Assessment of buccal bone thickness of aesthetic maxillary region: a cone-beam computed tomography study

  • Fuentes, Ramon;Flores, Tania;Navarro, Pablo;Salamanca, Carlos;Beltran, Victor;Borie, Eduardo
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.5
    • /
    • pp.162-168
    • /
    • 2015
  • Purpose: The aim of this study was to analyze the anatomical dimensions of the buccal bone walls of the aesthetic maxillary region for immediate implant placement, based upon cone-beam computed tomography (CBCT) scans in a sample of adult patients. Methods: Two calibrated examiners analyzed a sample of 50 CBCT scans, performing morphometric analyses of both incisors and canines on the left and right sides. Subsequently, in the sagittal view, a line was traced through the major axis of the selected tooth. Then, a second line (E) was traced from the buccal to the palatal wall at the level of the observed bone ridges. The heights of the buccal and palatal bone ridges were determined at the major axis of the tooth. The buccal bone thickness was measured across five lines. The first was at the level of line E. The second was at the most apical point of the tooth, and the other three lines were equidistant between the apical and the cervical lines, and parallel to them. Statistical analysis was performed with a significance level of $P{\leq}0.05$ for the bone thickness means and standard deviations per tooth and patient for the five lines at varying depths. Results: The means of the buccal wall thicknesses in the central incisors, lateral incisors and canines were $1.14{\pm}0.65mm$, $0.95{\pm}0.67mm$ and $1.15{\pm}0.68mm$, respectively. Additionally, only on the left side were significant differences in some measurements of buccal bone thickness observed according to age and gender. However, age and gender did not show significant differences in heights between the palatal and buccal plates. In a few cases, the buccal wall had a greater height than the palatal wall. Conclusions: Less than 10% of sites showed more than a 2-mm thickness of the buccal bone wall, with the exception of the central incisor region, wherein 14.4% of cases were ${\geq}2mm$.

A retrospective clinical study of survival rate of the ITI $TE^{(R)}$ implant (ITI $TE^{(R)}$ 임플란트의 생존율에 관한 후향적 임상 연구)

  • Suh, Hyun-Kee;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho;Chai, Jung-Kyu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.673-682
    • /
    • 2006
  • Recent study shows that implant design has a great impact on initial stability in bone. The ITI $TE^{(R)}$ implant, designed originally for immediate placement has a tapered/ cylindrical form which fits the anatomical shape of the natural alvelous or tooth root. The increased diameter at the collar region coupled with more threads lead to more bone contact and enhanced stability. The aim of this retrospective study is to evaluate the clinical use and the efficacy of recently introduced ITI TE implant with a new macro-design. The following results are compiled from 139 patients who received ITl TE implant surgery at the periodontal department. of Yonsei University Hospital between July 2002 and September 2005. 1. 139 patients received 173 ITl $TE^{(R)}$ implants in their maxilla and mandible (Mx 82, Mn 91). Posterior area accounted for 84% of the whole implant surgery, 2. In the distribution of bone quality, type III(41,0%) was the most, followed by type IV(41,0%) and type II (27.7%). As for the bone quantity, type B(43.9%) was the most, followed by type C(42.2%), type D(12.2%) and type A(1.7%). 3. 125 implants(83.9%) were treated by single crown, which accounted for the majority. 4, The total implant survival rate was 100% after a mean follow-up period of 21.2 months. This preliminary data with ITl $TE^{(R)}$ implant showed excellent survival rate although the majority of implants evaluated in this study were placed in the posterior region of the jaw and compromised sites.

Innovation and Creativity in Business Practices

  • Venkatesh, Bharti;Qureshi, Shazia
    • Journal of Distribution Science
    • /
    • v.10 no.4
    • /
    • pp.7-11
    • /
    • 2012
  • "Great things in business are never done by one person; they're done by a team of people." By Steve Jobs, 2003. As define by Linda Naiam - Creativity is the act of turning new and imaginative ideas into reality. Creativity involves two processes: thinking, then producing. Innovation is the production or implementation of an idea. If you have ideas, but don't act on them, you are imaginative but not creative. So in order to maintain the pace with the changing business scenario and coping with the competition Innovation and Creativity is considered a mandatory tool for a business to exist and grow in market. Whether a company is Employee centric or Business centric Innovation and creativity has to have its space in order to keep a business ahead of others in the Market. Also it's not just the competition which has led to the Innovation and Creativity in Business practices it's also the demanding chunk of consumers and customers who are aware and prefer maximum choices before making a final deal. Another reason as to why there is a change in business practices is the globalization of businesses where you need to rope in the Innovative ideas to launch and sustain in new market. There had been tremendous shift in business practices but to give a room to innovative ideas and implement that creativity need ample to space and vision along with an attitude where in you can resist for getting an immediate results from innovative business practices. Corporate Creativity is characterized by the ability to perceive the world in new ways, to find hidden patterns, to make connections between seemingly unrelated phenomena, and to generate solutions. Generating fresh solutions to problems, and the ability to create new products, processes or services for a changing market, are part of the intellectual capital that give a company its competitive edge. Creativity is a crucial part of the innovation equation. The innovation and creativity is not limited to any area of business, it can start from your waiting lounge to your board room meeting depending upon how the things are perceived and implemented for the betterment of people and business. The purpose of this research is to understand the latest creative business approaches and practices that organizations are following to be different from their competitors. Also this shift from generic business practices to the Innovative and Creative approach seems to take the business into new world. This approaches means starting from the bottom of the Pyramid and finally touching the pinnacles in Innovation and creativity. The paper will discuss on the various areas of business where in innovative approaches can be roped in and sets new bench mark altogether in the business arena.

  • PDF

Study on Osseointegration of the Immediate Placement Using Korean Implant Systems in Beagle Dog (성견에서 즉시 임플란트 식립시 국내 임플란트에서의 골 유착반응에 관한 연구)

  • Seo, Jung-Yoon;Lee, Wook-Jae;Lee, Jong-cheol;Shin, Mee-Ran;Kim, Yun-Sang;Pi, Sung-Hee;Shin, Hyung-Shik;You, Hyung-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.223-236
    • /
    • 2007
  • This study was attempted to evaluate home-manufactured implants by placing $Stage-1^{(R)}$ Implant (Lifecore, Co., USA) whose surface is treated with REM that has already been varified clinically,$Chaorum^{(R)}$ Implant(Chaorum Co., Korea) whose surface treatment is same as that of Stage-1 Implant and $Atlas^{(R)}$ Implant(Cewellmedi Co., Korea) whose surface is treated with anodic oxidation immediately after the teeth of experimental animals were extracted to compare histological findings among them. Stage-l Implant(diameter: 3.5mm, length: IOmm), Chaorum Implant(diameter: 3.3mm, length: 8.5mm) and Cowell medi Implant(diameter: 4.0mm, length: 8.0mm) were placed into the mandible premolars of 2 adult beagle dogs immediately after their teeth were extracted, and then histological findings were analyzed at 6 weeks. After those implants were inserted directly after their teeth were extracted, the results of periotest were recorded, radiography was done, the subjects went through thorough control for 6 weeks, and then comparison among periotest, radiography and histological finding was made. After comparison of those findings, the values of periotest were satisfactory and bone healing was relatively satisfactory on radiography at 6 weeks. For osseointegration with the bone tissue, Stage-1 was 45.3%, Chaorum 55.3%, and Cowellmedi 52.5%, which was a satisfactory result. Although implant surgery immediately after teeth were extracted involves difficulties among recent implant surgeries, it is being frequently used in that it may reduce surgery hours, the frequency of surgery, and bone loss for patients. This experiment was conducted to evaluate the technological levels of home-manufactured implants that have been remarkably developed in recent years and in conclusion, those implants showed nearly similar result.

Radiologic evaluation and survival rate of taper-straight designed implant with SLA surface: A 1-year follow-up retrospective study (SLA surface를 가진 taper straight designed implant의 방사선학적 평가와 생존율: 1년 추적 관찰을 통한 후향적 연구)

  • Kim, Jee Eun;Kim, Ye Seul;Kim, Ok-Su
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.405-414
    • /
    • 2021
  • Purpose. This study was conducted to evaluate clinical usefulness by evaluating the marginal bone resorption and survival rate of an implant with a taper straight type SLA surface domestically available on the market recently. Materials and methods. 40 implants satisfying the including criteria were observed for one year of 125 implants of 83 adult men and women who had KISPLANT® implanted from August 2016 to December 2019 at the Department of Periodontology, Chonnam National University Dental Hospital. The marginal bone level was measured on periapical radiographs taken initially and 1 year later and we analyzed implant survival and success rates. A t-test was used for the analysis of the association between the marginal bone resorption and the severity of periodontitis, supportive periodontal therapy, the inserted site, the cause of extraction, immediate placement, and systemic disease. Results. After 1 year of loading, the mesial bone resorption was 0.74 ± 1.07 mm, and the distal bone resorption was 0.53 ± 1.04 mm. The marginal bone resorption of 2 mm or more occurred at 3 implants out of 40 implants after 1 year, so the success rate of implant was 92.5% and survival rate was 100%. There was a significant difference in mesial marginal bone resorption according to the inserted site and no significant differences were found between marginal bone resorption and the other factors. Conclusion. As a result of marginal bone resorption, success rate, and survival rate in this study, we found little marginal bone resorption and high survival and success rate. It can be concluded that they represent excellent clinical results.