• Title/Summary/Keyword: Immediate implant

Search Result 277, Processing Time 0.021 seconds

Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report (수술용 가이드와 modeless 디지털 보철물을 이용한 하악 구치부 단일 임플란트 즉시 하중 증례)

  • Lim, Hyun-jeong;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2017
  • In this case report, immediate loading of an implant-supported single-tooth prosthesis through complete digital workflow. A patient presented for restoration of missing a single tooth in the mandibular first molar. The digital impression was made with intraoral scanner and implant was placed using surgical guide pre-fabricated with pre-operative computed tomography (CT) and scan data. After 1 week later, prefabricated customized abutment and provisional restoration were connected for immediate loading. After 8 weeks later, abutment level impression was taken by intraoral scanner. At 3 months later from implant installation, monolithic zirconia crown were fabricated. This clinical report presents satisfying result in accuracy and patient satisfaction. A completely modeless digital procedure met expectations regarding precision, esthetics, and functionality.

FUNCTIONAL RECOVERY OF MANDIBULAR HIGH CONDYLAR FRACTURE PATIENT WITH IMMEDIATE PROVISIONAL IMPLANT: CASE REPORT (Immediate provisional implant를 이용한 하악골 high condylar fracture환자의 기능회복: 증례보고)

  • Jang, Bo-Young;Ahn, Mi-Ra;Ahn, Kyung-Mi;Lee, Won-Hyuk;Shon, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.1
    • /
    • pp.82-88
    • /
    • 2005
  • Treatment methods of mandibular condylar fracture were conservative and surgical method. Surgical method of mandibular high condylar fracture was very difficult because approach and internal fixation of small size fracture fragment were difficult. So there is a tendency to select conservative method over surgical method for guiding a stable occlusion and avoiding TMJ disorder and growth disturbance, minimizing pain and deviation during function. But, in case of mandibular high condylar fracture patient who has no biting teeth on posterior teeth area, guiding a stable occlusion and conservative functional treatment were very difficult. In this case, patient was 62years old male. He had fracture of mandibular symphysis, right mandibular body, left mandibular high condyle. We treated the patient for mandibular symphysis and right mandibular body fracture area with surgical method. But left mandibular high condylar fracture area was difficult to treat with surgical method. So we selected a conservative functional method on left mandibular high condylar fracture area. We intended recovery of vertical dimension and stable occlusion with implantation of immediate provisional implant on maxillar and mandibular posterior teeth area, and temporary crown. And then patient did mandibular functional movement and his mandibular function was recoverd.

Digital interim immediate denture fabrication and implant-supported removable partial denture fabrication after multiple teeth extraction in patient with chronic periodontitis: a case report (만성 치주염 환자에서 다수치 발거 후 디지털 임시 즉시 의치 제작 및 임플란트 지지 가철성 국소의치 수복 증례)

  • Min-Jae Park;Ji-Won Bang;Joo-Hyuk Bang;Seon-Young Lim;Yong-Sang Lee;Keun-Woo Lee;Sung-Yong Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.104-112
    • /
    • 2024
  • When teeth are extracted, patient face social, psychological and aesthetic problems which can be minimized by fabricating a interim immediate denture. Interim immediate denture manufactured using digital technology can be completed with reduced number of patients' visits and simple laboratory process. Implant-supported removable partial denture (ISRPD) has been suggested as alternative treatment option when fixed implant prosthesis is not feasible. In this case, interim immediate dentures were fabricated using digital technology for patient after teeth extraction and treatment using ISRPD by installing implants and surveyed crowns is found to be successful with better support, stability and maintenance of removable partial dentures.

Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report (구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례)

  • Chang, Yun-Jeong;Kim, Hong-Jun;Song, Mi-Kyoung;Moon, Ji-Eun;Lee, Hal-La;Park, Chan-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.234-243
    • /
    • 2015
  • Developing of digital technique, it is possible to fabricate implant prostheses for edentulous area using intraoral 3-dimentional information throughout implant diagnosis and treatment process. It is being changed that from the method using CAD/CAM, producing prostheses by model scanning after conventional impression and model processing, to the method of fabricating implant provisional restorations and customized abutments by digital impression after connecting digital impression copings (scanbody) and implant fixtures without models. But, this digital method has not been actively used for implant prostheses not yet. Specially, it is short of intraoral digital impression cases for immediate provisional restorations of the maxillary anterior implants. The gingival contour impression of maxillary anterior area is very important for esthetic restorations. Accordingly, in this case report, the using a digital impression coping (scanbody) and digital impression by CEREC Omnicam (Sirona, Bensheim, Germany) or Trios (3shape, Copenhagen, Denmark) were introduced for immediate provisional restorations in 3 cases needed a single implant restoration in maxillary anterior area. The clinical results were satisfactory on the convenience and accuracy of digital impression technique and the good esthetics of final restorations.

Immediate implantation for single mandibular first molar restoration: clinical case report (하악 제1대구치 단일 수복을 위한 발치 즉시 임플란트의 임상증례)

  • Park, Cheol-Woo
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.4-12
    • /
    • 2021
  • Immediate implantation is widely applied as it is recognized as a useful implant treatment in dental clinic due to its various advantages as well as being able to shorten the treatment period. Immediate implant treatment was performed on 5 patients who needed extraction of the mandibular first molar for various reasons, shortening the overall treatment period, and obtaining satisfactory results. Immediate implantation after extraction is a high-level treatment that requires proper initial fixation at the exact location of the extraction socket and the surrounding soft tissues, but is considered to be a clinically very useful prosthetic restoration method

Methylene Blue Dye-Induced Skin Necrosis in Immediate Breast Reconstruction: Evaluation and Management

  • Lee, Ji Hwan;Chang, Choong Hyun;Park, Chan Heun;Kim, June-Kyu
    • Archives of Plastic Surgery
    • /
    • v.41 no.3
    • /
    • pp.258-263
    • /
    • 2014
  • Background For early breast cancer patients, skin-sparing mastectomy or nipple-sparing mastectomy with sentinel lymph node biopsy has become the mainstream treatment for immediate breast reconstruction in possible cases. However, a few cases of skin necrosis caused by methylene blue dye (MBD) used for sentinel lymph node localization have been reported. Methods Immediate breast reconstruction using a silicone implant was performed on 35 breasts of 34 patients after mastectomy. For sentinel lymph node localization, 1% MBD (3 mL) was injected into the subareolar area. The operation site was inspected in the postoperative evaluation. Results Six cases of immediate breast reconstruction using implants were complicated by methylene blue dye. One case of local infection was improved by conservative treatment. In two cases, partial necrosis and wound dehiscence of the incision areas were observed; thus, debridement and closure were performed. Of the three cases of wide skin necrosis, two cases underwent removal of the dead tissue and implants, followed by primary closure. In the other case, the breast implant was salvaged using latissimus dorsi musculocutaneous flap reconstruction. Conclusions The complications were caused by MBD toxicity, which aggravated blood disturbance and skin tension after implant insertion. When planning immediate breast reconstruction using silicone implants, complications of MBD should be discussed in detail prior to surgery, and appropriate management in the event of complications is required.

COMPARATIVE STUDY ON THE MARGINAL BONE LOSS OF IMMEDIATE NONSUBMERGED AND SUBMERGED ENDOSSEOUS DENTAL IMPLANTS PLACED INTO EXTRACTION SOCKETS OF DOGS (발치후 즉시 매식한 Nonsubmerged와 Submerged 임플랜트의 변연골 흡수양상에 관한 비교연구)

  • Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.255-264
    • /
    • 1997
  • The conventional osseointegration protocol calls for waiting up to 12 months for ossification of an extraction socket to heal before placing an endosseous implant. In this study, the possibility of placing a pure titanium implant directly into an extraction socket immediately after extraction was investigated. And the marginal bone loss of immediate nonsubmerged and submerged endosseous dental implants placed into extraction sockets was also compared. Pure titanium Nobelpharma Branemark implants and solid screw type ITI implants were placed into premolar extraction sockets of two adult dogs and allowed to heal for a period of 3 months, followed by functional loading of the implant. Radiographic examination was performed before implantation, immediately after implantation and 3, 6, 9, 12 months after implantation. The results obtained were as follows : 1. Immediately placed nonsubmerged ITI implants and submerged Branemark implants showed favorable radiographic osseointegration status and there were minimum marginal bone loss. 2. There were no significant differences in radiographic finding of osseointegration between conventional and immediate implantation. 3. Gingival tissue around implants showed more inflammatory signs than that of adjacent natural teeth. This study suggest that pure titanium Branemark implants and submerged ITI implants have the potential to integrate when placed immediatly after extraction of the teeth and warrants further investigation.

  • PDF

Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study

  • Leesungbok, Richard;Seo, Jin-Ho;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.163-166
    • /
    • 2018
  • PURPOSE. The marginal bone loss of implants with laser treated surface was investigated after six weeks of loading after implant installation to the mandible molar area. MATERIALS AND METHODS. A total of 23 implants were placed in the edentulous molar area of the mandible: 13 implants were immediately loaded and 10 implants were early loaded. The implants used were made of titanium grade 23, screw shaped, 4.2 mm in diameter, and 10 mm in length. Patients were evaluated with resonance frequency analysis at implant fixture installation and 1, 2 (final prosthesis installation), 3, 5, 8, and 14 months later. X-rays were taken at 2 months after fixture installation and 1, 2, 3 years after to measure the marginal bone loss. RESULTS. The mean ISQ value measured at the implant installation was over 70 at all-time points. The average of marginal bone loss was average 0.33 mm. CONCLUSION. Immediate implant loading for laser treated implants would be possible.

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis (Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례)

  • Kim, Seong-Mo;Park, Jin-Hong;Ryu, Jae-Jun;Shin, Sang Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.126-133
    • /
    • 2018
  • The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

  • Kim, Sung-Eun;Jung, Dong-Woo;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Tae Gon;Kim, Yong-Ha;Lee, Soo Jung;Kang, Su Hwan;Choi, Jung Eun
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.529-534
    • /
    • 2014
  • Background In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. Methods From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. Results The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. Conclusions By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.