• 제목/요약/키워드: Imaging phantom

검색결과 551건 처리시간 0.027초

Analysis of Tubular Structures in Medical Imaging

  • Kim, Jin-Woo
    • Journal of information and communication convergence engineering
    • /
    • 제7권4호
    • /
    • pp.545-550
    • /
    • 2009
  • A method fully utilizing multiscale line filter responses is presented to estimate the point spread function(PSF) of a CT scanner and diameters of small tubular structures based on the PSF. The estimation problem is formulated as a least square fitting of a sequence of multiscale responses obtained at each medical axis point to the precomputed multiscale response curve for the ideal line model. The method was validated through phantom experiments and demonstrated through phantom experiments and demonstrated to accurately measure small-diameter structures which are significantly overestimated by conventional methods based on the full width half maximum(FWHM) and zero-crossing edge detection.

자기공명영상진단을 위한 RF 코일 제작 (A Birdcage Resonator for Magnetic Resonance Imaging)

  • 원진임;정은기;권영길;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.662-664
    • /
    • 1999
  • 본 연구에서는 자기공명영상에서 인체에 에너지를 주고, 신호를 받는 transceiver 역할을 하는 RF(Radio Frequency) 코일을 제작하여 phantom의 영상을 얻었다. 코일의 종류는 high-pass 타입의 birdcage형으로 제작을 하였으며, 영상을 얻는데 사용한 자기공명영상진단장비는 주 자기장의 세기가 1.5T인 GE사의 시스템이다. 이 시스템을 이용하여 phantom의 축방향과 축방향에 수직인 두 방향의 영상을 얻었다.

  • PDF

Development of an imaging QA phantom for Tomotherapy

  • Chang, Ji-Na;Oh, Seung-Jong;Jung, Won-Gyun;Jang, Hong-seok;Kim, Hoi-Nam;Kang, Dae-Gyu;Suh, Tae-Suk
    • 대한방사선방어학회:학술대회논문집
    • /
    • 대한방사선방어학회 2009년도 춘계 학술발표
    • /
    • pp.176-177
    • /
    • 2009
  • See Full Text

  • PDF

Paraffin을 이용한 Thyroid Phantom제작에 따른 유용성에 관한 연구 (A study on the Effectivness of Hand-made Paraffin Thyroid Phantom)

  • 박성옥;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권3호
    • /
    • pp.237-243
    • /
    • 2007
  • 방사성의약품을 이용한 핵의학적 영상기록에 있어 장기가 함유하고 있는 정보량을 최대한 묘출시켜 양질의 진단정보를 제공해야 한다는 것은 매우 중요하다. 그것을 위한 기술적인 문제를 비롯하여 장비성능의 유지관리에 많은 노력을 기울이고 있으며, 다양한 종류로 상업화되어 이용되고 있는 우수한 phantom들이 사용되고 있다. 본 연구에서 인체의 연부조직과 매우 흡사한 물리적 조건을 가지고 있으며 구입하기 쉬운 Paraffin을 이용하여 기존에 사용되고 있는 acryl thyroid phantom과 동일하게 paraffin phantom을 제작하였으며, 판매되고 있는 acryl thyroid phantom에서 측정할 수 있는 것 보다 더 높은 분해능을 측정할 수 있도록 작은 3mm와 6mm 직경의 cold area를 삽입한 paraffin thyroid phantom을 수작업으로 제작하였다. 방사성의약품 $^{99m}TcO_4$를 이용하고 pinhole collimator를 이용하여 상업화되어 사용되고 있는 acryl thyroid phantom과 본 연구를 위하여 제작한 paraffin thyroid phantom의 특성을 비교 분석한 결과 paraffin을 이용한 phantom도 상업화되어 사용 중인 acryl thyroid phantom과 동일한 물리적 특성을 유지하고, 오히려 분해능이 높은 부분을 측정할 수 있고 연부조직의 특성을 연구할 수 있는 등가물질로서 구입하기 쉽고 제작이 수월한 장점을 비롯하여 경제성이 있음을 증명하는 계기가 되었다.

  • PDF

자기공명영상 화질 평가용 팬텀 개발에 관한 연구 (Development of MRI Phantom for Assessing MR Image Quality)

  • 안창범;나동규;김광기;김동성;김인수;이정휘;홍석주;변재호;강현수;장기원;송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.89-97
    • /
    • 2006
  • 목적 : 자기공명영상 화질을 평가하는 팬텀으로서 코일 장착도구가 내장된 새로운 형태의 팬텀을 개발하였다. 대상 및 방법 : 자기공명영상 화질평가항목인 절편 두께 정확도, 공간 분해능, 대조도 분해능, 기하학적 정확도, 절편 위치 정확도, 영상강도 균일성, 고스트 신호 백분율, 신호대잡음비 등 총 8개의 사양을 가진 팬텀을 고안하였다. 팬텀의 코일 장착을 위한 장치가 팬텀 표면에 설치 되었다. 개발된 팬텀의 임상적용가능성을 알아보기 위하여 6개의 다른 종류의 자기공명영상기기를 사용하여 영상을 습득하였고 이들 화질이 평가되었다. 결과 : 사용된 모든 자기공명영상기기에서 영상평가에 문제가 없는 영상을 보여주었고 그들의 평가결과는 일부 평가항목에서 실측치와 비교하여 적절한 값 범위에 있음을 확인하였다. 코일장착도구를 사용하여 팬텀을 두부용 코일 안에 설치하는 데 문제가 없음을 확인하였다. 결론 : 본 논문에서 개발된 팬텀은 자기공명영상 화질을 평가하는 데 있어 그 임상적용 가능성이 있음을 보여주었다.

  • PDF

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

Imaging Plate를 이용한 의료용 광자선의 선량측정 (Application of an imaging plate to relative dosimetry of clinical x-ray beams)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.117-122
    • /
    • 2000
  • 해상도가 뛰어나며 디지털영상으로 저장하므로 공간에 제약을 받지 않으며 재사용이 가능하다는 장점으로 현재 국내 병원에서는 Imaging Plate(IP)가 필름을 대체해가고 있는 추세에 있다. 본 연구는 진단용으로 사용되는 If를 이용하여 치료영역에서 선량측정용도로의 가능성 여부를 알아보고자 하였다. 실험을 하는데 사용되었던 IP는 Fuji사의 ST-V$_{A}$라는 모델이고 가속기는 Varian 2100C의 6 MV 광자선을 사용하였다. 먼저 전리함으로 측정한 심부선량을 기준으로 If로 측정한 값과 비교를 하였다. 조사문 선량(portal dose)을 측정하기 위하여 SSD=100 cm 위치에 두께 14 cm 되는 폴리스틸렌 팬텀을 놓고 그 밑에 전자포탈영상기구(Electronic Portal Imaging Device: EPID)가 위치한 지점에서 상대적 흡수선량(Off Axis Ratio: OAR)을 측정 그리고 계산하였다. 이때 전리함, 필름(Kodak X-Omat V) 및 IP를 전자포탈영상기구와 같은 위치에 놓고 측정을 하였고 이에 더하여 EGS4 몬테칼로전산모사를 통하여 조사문 선량을 계산하였다. 심부선량(PDD)을 측정한 결과 IP는 BaFBr:Eu$^{2+}$의 인광물질로 이루어져 있기 때문에 물보다 전자밀도가 높아 산란선에 매우 민감함을 알 수 있었다. 따라서 현재 진단영역에서 사용되고있는 IP는 심부선량측정계로는 적합하지 않다. 그러나 IP는 반음영외부부분(outside penumbra)을 제외한 조사문 선량측정에 비교적 정확한 것으로 밝혀졌다 또한 IP를 치료위치 확인용으로 사용할 수 있을 것으로 기대된다.

  • PDF

선형 트랜스듀서를 이용한 혈관 변형률 영상법 (Blood Vessel Strain Imaging Using Linear Array Transducer)

  • 안동기;정목근
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.880-890
    • /
    • 2010
  • 뇌졸중 등의 혈관 질병을 진단하기 위해서 혈관 내 초음파(Intravascular Ultrasound:IVUS)영상 기법이 사용되고 있다. 최근에는 혈관 내벽에 붙은 혈전을 탄성 영상법을 이용하여 진단하는 방법들이 연구되고 있다. 그러나 혈관 내 초음파는 혈관 내에 트랜스듀서를 삽입하여야 하므로 진단 방법에 위험성이 있다. 본 논문은 선형 트랜스듀서를 이용하여 혈관 외부에서 데이터를 획득하여 혈관 내벽에 붙은 혈전의 변형률 영상을 얻었다. 혈관 벽의 움직임을 정확하게 측정하기 위하여, 혈관 벽과 수직이 되도록 주사선의 방향을 조향하면서 초음파 데이터를 획득하였다. 초음파 데이터는 기저대역의 복소수 신호로 복조한 뒤 자기상관(autocorrelation)을 이용하여 혈관 벽의 움직임을 계산하여 변형률 영상을 얻었다. 제안한 방법을 플라스틱 기반의 혈관 모사 팬텀을 제작하여 검증하였다. 혈관 모사 팬텀은 혈관에 해당하는 직경 6mm의 실린더 공간에 물을 채우고 벽을 따라 2mm 두께의 부드러운 혈전을 혈관 벽의 내부에 배치하였다. RF 데이터는 상용 초음파 진단기에서 7.5MHz 선형 트랜스듀서를 사용하여 -40도부터 40도까지 1도 간격으로 조향시킨 81개의 스캔라인 데이터를 얻었다. 실험 결과 단단한 배경 팬텀에 인접한 혈전 영역이 더 무른 것으로 관찰되었다. 제안한 방법의 탄성 영상법이 비록 주사선이 혈관 벽에 수직으로 입사하는 영역으로 제한되지만 혈관 변형률 영상법의 유용함을 실험으로 입증하였다.

다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구 (A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters)

  • 박성우;이종인;이영진
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.765-771
    • /
    • 2019
  • Skull X-ray 영상에서 노이즈의 발생은 불가피하며, 이는 영상 화질과 진단 정확도를 저하시키고 디지털 영상 장치의 특성상 오류를 증가시킨다. 이러한 노이즈는 선량을 증가시키면 쉽게 감쇠되긴 하지만 환자가 받는 피폭선량이 더 큰 문제를 야기할 수 있다. 그래서 선량문제를 해결하고 동시에 노이즈를 줄이기 위해저 선량에서 노이즈 감소 알고리즘이 활발히 연구되고 있는데, 초기에 개발되고 널리 사용되어진 median filter와 Wiener filter는 노이즈 감소 효율이 떨어지고 영상경계에 대한 정보가 많이 손실된다는 단점이 있다. 본 연구의 목적은 이전 노이즈 감소효율의 문제점을 보완할 수 있는 total variation (TV) 알고리즘을 skull X-ray 영상에 적용하여 정량적으로 평가하고 비교를 하는 것이다. 이를 위해 Siemens사의 X-ray 장치를 사용하여 성인 skull을 모사할 수 있는 팬텀을 통해 다양한 관전압과 관전류량을 사용하여 실제 skull X-ray 팬텀 영상을 획득하였다. 또한, 각각의 팬텀 영상에 noisy image, median filter, Wiener filter, TV 알고리즘을 적용하였을 때의 대조도 대 잡음비 (CNR)와 변동계수 (COV)를 비교 측정했다. 실험 결과 TV 알고리즘을 적용하였을 때, 모든 조건에서 CNR와 COV 특성이 우수함을 확인할 수 있었다. 결론적으로 이번 연구를 통해 TV 알고리즘을 사용하여 영상의 질을 높일 수 있는지에 대해 확인해 보았고, 이론적으로 CNR 값은 관전류량이 증가할수록 노이즈가 감소함으로 인해 증가하는 것을 알아볼 수 있었다. 반면에, COV는 관전류량이 증가할수록 감소하였으며 관전압이 증가하였을 때 noise는 감소하고 투과량이 증가하여 COV가 감소하는 것을 알아볼 수 있었다.