• 제목/요약/키워드: Imaging anatomy

검색결과 246건 처리시간 0.031초

Anthropometric Analysis of Frontal Sinus Using 3D CT in Koreans (한국인 성인 남녀에서 3차원 전산화단층촬영술을 이용한 전두동의 형태학적 연구)

  • Shim, Byung-Kwan;Kim, Jun-Hyuk;Shin, Ho-Seong;Lee, Young-Man
    • Archives of Plastic Surgery
    • /
    • 제38권5호
    • /
    • pp.594-601
    • /
    • 2011
  • Purpose: The frontal sinuses are a pair of triangularly shaped, air-filled chambers lined by mucoperiosteum and located between the inner and outer tables of the frontal bone. Until recently, our understanding of gender variations in craniofacial anatomy has been chiefly built upon anthropometric studies, which typically employ facial surface measurements or plain film radiography. The aim of this study i to determine the sizes of the frontal sinus in both sexes in Koreans. Methods: 95 Korean subjects who underwent maxillofacial 3-Dimensional computed tomography (CT) between January 2009 and December 2009 were enrolled. Frontal sinus dimensions and forehead measurements were taken at midline and at 10, 20, and 30 mm to the left and right of midline using sagittal, coronal, and axial images. The data was analyzed for significant differences between measurements made at the selected points in the frontal sinus, for left to right variations, for gender variations, and for racial differences. Results: The mean thickness of the anterior table ranged from 2.31 to 3.23 mm. Mean anteroposterior depth of the frontal sinus ranged from 7.38 to 9.45 mm and did not vary significantly at any distance from midline. Frontal sinus height was greatest at midline (mean=29.24 mm) and progressively lessened at lateral distances. Mean total width at the level of the supraorbital ridge was 53.66 mm. For all measurements, no significant left to right variation was noted. Comparing the sexes, males were found to have greater dimensions in most frontal sinus measurements, though these differences were only found to be significant at or close to midline. The male forehead was marked by more acute nasofrontal angle ($133.3^{\circ}$ versus $141.6^{\circ}$) and a steeper posterior forehead inclination ($14.9^{\circ}$ versus $7.7^{\circ}$). Conclusion: Using CT imaging, forehead and frontal sinus dimensions have been described. Generally, males had larger overall frontal sinus dimensions. And Korean had similar sized frontal sinus to Caucasian in height and width. But in AP distance Korean had lesser measurement. The result of this study may be helpful in the comprehension of normal size of frontal sinus in Korean.

A Study on the Usefulness of Copper Filter in Single X-ray Whole Spine Lateral using 3D Printer (단일조사 whole spine Lateral 검사에서 3D 프린터로 제작한 구리 필터 유용성 연구)

  • Kwon, Kyung-Tae;Yoon, Dayeon;Shin, Rae-Un;Han, Bong-Ju;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • 제14권7호
    • /
    • pp.899-906
    • /
    • 2020
  • The WSS lateral examination is important for diagnosing spinal disorders. Recently, long-length detectors for large-area diagnose have been popularized to effectively reduce the exposure dose and examination time. It can be applied very efficiently to examinations of patients with high risk of falls, children, and adolescents. However, since the image is acquired through a single irradiation, the volume of cervical vertebra is relatively smaller than the lumbar due to the geometrical anatomy of the spine. Therefore, this study intends to fabricate an additional filter using 3D printing technology and copper filament to obtain uniform image quality in the WSS lateral examination and to analyze the results. 3D printing technology is able to easily print a desired shape, so it is widely used in the entire industrial field, and recently, a copper filament has been developed to confirm the possibility as an additional filter. In the WSS lateral examination, CNR and SNR were excellently measured when the additional filter was applied, confirming the possibility of using the additional filter.

Accuracy evaluation of liver and tumor auto-segmentation in CT images using 2D CoordConv DeepLab V3+ model in radiotherapy

  • An, Na young;Kang, Young-nam
    • Journal of Biomedical Engineering Research
    • /
    • 제43권5호
    • /
    • pp.341-352
    • /
    • 2022
  • Medical image segmentation is the most important task in radiation therapy. Especially, when segmenting medical images, the liver is one of the most difficult organs to segment because it has various shapes and is close to other organs. Therefore, automatic segmentation of the liver in computed tomography (CT) images is a difficult task. Since tumors also have low contrast in surrounding tissues, and the shape, location, size, and number of tumors vary from patient to patient, accurate tumor segmentation takes a long time. In this study, we propose a method algorithm for automatically segmenting the liver and tumor for this purpose. As an advantage of setting the boundaries of the tumor, the liver and tumor were automatically segmented from the CT image using the 2D CoordConv DeepLab V3+ model using the CoordConv layer. For tumors, only cropped liver images were used to improve accuracy. Additionally, to increase the segmentation accuracy, augmentation, preprocess, loss function, and hyperparameter were used to find optimal values. We compared the CoordConv DeepLab v3+ model using the CoordConv layer and the DeepLab V3+ model without the CoordConv layer to determine whether they affected the segmentation accuracy. The data sets used included 131 hepatic tumor segmentation (LiTS) challenge data sets (100 train sets, 16 validation sets, and 15 test sets). Additional learned data were tested using 15 clinical data from Seoul St. Mary's Hospital. The evaluation was compared with the study results learned with a two-dimensional deep learning-based model. Dice values without the CoordConv layer achieved 0.965 ± 0.01 for liver segmentation and 0.925 ± 0.04 for tumor segmentation using the LiTS data set. Results from the clinical data set achieved 0.927 ± 0.02 for liver division and 0.903 ± 0.05 for tumor division. The dice values using the CoordConv layer achieved 0.989 ± 0.02 for liver segmentation and 0.937 ± 0.07 for tumor segmentation using the LiTS data set. Results from the clinical data set achieved 0.944 ± 0.02 for liver division and 0.916 ± 0.18 for tumor division. The use of CoordConv layers improves the segmentation accuracy. The highest of the most recently published values were 0.960 and 0.749 for liver and tumor division, respectively. However, better performance was achieved with 0.989 and 0.937 results for liver and tumor, which would have been used with the algorithm proposed in this study. The algorithm proposed in this study can play a useful role in treatment planning by improving contouring accuracy and reducing time when segmentation evaluation of liver and tumor is performed. And accurate identification of liver anatomy in medical imaging applications, such as surgical planning, as well as radiotherapy, which can leverage the findings of this study, can help clinical evaluation of the risks and benefits of liver intervention.

Diagnosis of Location and Size of Lesions using Chest X-ray Image (X-선 영상을 이용한 암의 위치 및 크기 진단)

  • Jung-Min, Son;Byung-Ju, Ahn
    • Journal of the Korean Society of Radiology
    • /
    • 제17권1호
    • /
    • pp.167-173
    • /
    • 2023
  • X-ray general radiography is the simplest and most important one to get a lot of information. Nevertheless, current x-ray general radiography does not observation in-depth observation. Information about the anatomy of the human body and changes in disease in x-ray general radiography can be obtained but it is difficult to determine the size and shape of the actual lesion due to the disadvantage of expanding the image. In this study, PA and LAT images were acquired and cancer magnification was calculated in the images by measuring the distance of cancer samples. By adjusting the magnification the actual cancer length and thickness were measured and compared with the CT image and the actual cancer sample size. After the PA and LAT images of the inserted 6.0 mm cancer sample were obtained and the magnification was corrected, the length was 5.9 mm and the thickness was 6.1 mm. This value was measured similarly to the actual. The problem of obtaining the magnification that needs to know the actual length from the detector to the cancer sample was secured by obtaining the magnification through PA and LAT images and it is possible to accurately measure the cancer sample size. X-ray general radiography may provide useful information in situations where CT imaging is difficult.

Elderly Sarcopenia and Vitamin B Deficiency: A Relationship? (비타민 B 결핍에 의한 노인성 근감소증)

  • Kisang Kwon;Hye-Jeong Jang;Sun-Nyoung Yu;Soon-Cheol Ahn;O-Yu Kwon
    • Journal of Life Science
    • /
    • 제33권7호
    • /
    • pp.574-585
    • /
    • 2023
  • Sarcopenia is a leading cause of increased medical and nursing care costs among the elderly. In Korea, preventive measures for sarcopenia are mostly targeted toward the general elderly population without specific diseases. However, it is also necessary to implement measures for elderly individuals living in nursing homes and hospitals, where the prevalence of sarcopenia is high. Currently, computed tomography and/or magnetic resonance imaging are considered standard diagnostic tools. However, their complexity and time-consuming nature make them unsuitable for clinical use. The exact pathophysiological mechanisms of sarcopenia are unclear, as they involve various molecular biological pathways, including decreased exercise, protein and nutrient intake, changes in testosterone and growth hormone, and inflammation. Sarcopenia symptoms can lead to several diseases, such as osteoporosis, fractures, dementia, diabetes, and cardiovascular disease. Vitamin B deficiency is a significant factor in sarcopenia induction, with B vitamins being directly involved in energy and protein metabolism and nerve function. Vitamin B deficiency can lead to neuromuscular and neurogenic disorders, which often overlap with sarcopenia. Suboptimal intake of B vitamins, malabsorption, and anorexia are common among the elderly. This study aims to provide information on the role of water-soluble B vitamins in preventing and controlling muscle mass loss and deterioration among the elderly with sarcopenia. In addition, we discuss the potential of myokines from the B vitamin family in modulating sarcopenia.

Utility of Multidetector Computed Tomographic Angiography as an Alternative to Transesophageal Echocardiogram for Preoperative Transcatheter Mitral Valve Repair Planning

  • Craig Basman;Caroline Ong;Tikal Kansara;Zain Kassam;Caleb Wutawunashe;Jennifer Conroy;Arber Kodra;Biana Trost;Priti Mehla;Luigi Pirelli;Jacob Scheinerman;Varinder P Singh;Chad A Kliger
    • Journal of Cardiovascular Imaging
    • /
    • 제31권1호
    • /
    • pp.18-23
    • /
    • 2023
  • BACKGROUND: Three-dimensional (3D) transesophageal echocardiogram (TEE) is the gold standard for the diagnosis of degenerative mitral regurgitation (dMR) and preoperative planning for transcatheter mitral valve repair (TMVr). TEE is an invasive modality requiring anesthesia and esophageal intubation. The severe acute respiratory syndrome coronavirus 2 pandemic has limited the number of elective invasive procedures. Multi-detector computed tomographic angiography (MDCT) provides high-resolution images and 3D reconstructions to assess complex mitral anatomy. We hypothesized that MDCT would reveal similar information to TEE relevant to TMVr, thus deferring the need for a preoperative TEE in certain situations like during a pandemic. METHODS: We retrospectively analyzed data on patients who underwent or were evaluated for TMVr for dMR with preoperative MDCT and TEE between 2017 and 2019. Two TEE and 2 MDCT readers, blinded to patient outcome, analyzed: leaflet pathology (flail, degenerative, mixed), leaflet location, mitral valve area (MVA), flail width/gap, anterior-posterior (AP) and commissural diameters, posterior leaflet length, leaflet thickness, presence of mitral valve cleft and degree of mitral annular calcification (MAC). RESULTS: A total of 22 (out of 87) patients had preoperative MDCT. MDCT correctly identified the leaflet pathology in 77% (17/22), flail leaflet in 91% (10/11), MAC degree in 91% (10/11) and the dysfunctional leaflet location in 95% (21/22) of patients. There were no differences in the measurements for MVA, flail width, commissural or AP diameter, posterior leaflet length, and leaflet thickness. MDCT overestimated the measurements of flail gap. CONCLUSIONS: For preoperative TMVr planning, MDCT provided similar measurements to TEE in our study.

The Parathyroid Gland: An Overall Review of the Hidden Organ for Radiologists (부갑상선: 부갑상선 영상에 익숙하지 않은 영상의학과 의사들을 위한 전반적인 검토)

  • Suho Kim;Jung Hee Shin;Soo Yeon Hahn;Haejung Kim;Myoung Kyoung Kim
    • Journal of the Korean Society of Radiology
    • /
    • 제85권2호
    • /
    • pp.327-344
    • /
    • 2024
  • Parathyroid glands are small endocrine glands that regulate calcium metabolism by producing parathyroid hormone (PTH). These are located at the back of the thyroid gland. Typically, four glands comprise the parathyroid glands, although their numbers may vary among individuals. Parathyroid diseases are related to parathyroid gland dysfunction and can be caused by problems with the parathyroid gland itself or abnormal serum calcium levels arising from renal disease. In recent years, as comprehensive health checkups have become more common, abnormal serum calcium levels are often found incidentally in blood tests, after which several additional tests, including a PTH test, ultrasonography (US), technetium-99m sestamibi parathyroid scan, single-photon-emission CT (SPECT)/CT, four-dimensional CT (4D-CT), and PET/CT, are performed for further evaluation. However, the parathyroid gland remains an organ less familiar to radiologists. Therefore, the normal anatomy, pathophysiology, imaging, and clinical findings of the parathyroid gland and its associated diseases are discussed here.

Early laboratory values after liver transplantation are associated with anastomotic biliary strictures

  • Matthew Fasullo;Priyanush Kandakatla;Reza Amerinasab;Divyanshoo Rai Kohli;Tilak Shah;Samarth Patel;Chandra Bhati;Doumit Bouhaidar;Mohammad S. Siddiqui;Ravi Vachhani
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • 제26권1호
    • /
    • pp.76-83
    • /
    • 2022
  • Backgrounds/Aims: The aim of this study was to evaluate longitudinal changes of post-liver transplantation (LT) biliary anatomy and to assess the association of increased laboratory values after LT with the development of post-LT anastomotic biliary stricture (ABS). Methods: Adult deceased donor LT recipients from 2008 and 2019 were evaluated. ABS was defined after blinded review of endoscopic cholangiograms. Controls were patients who underwent LT for hepatocellular carcinoma who did not have any clinical or biochemical concerns for ABS. Results: Of 534 patients who underwent LT, 57 patients had ABS and 57 patients served as controls. On MRI, ABS patients had a narrower anastomosis (2.47 ± 1.32 mm vs. 3.38 ± 1.05 mm; p < 0.01) and wider bile duct at 1-cm proximal to the anastomosis (6.73 ± 2.45 mm vs. 5.66 ± 1.95 mm; p = 0.01) than controls. Association between labs at day 7 and ABS formation was as follows: aspartate aminotransferase hazard ratio (HR): 1.014; 95% confidence interval (CI): 1.008-1.020, p = 0.001; total bilirubin HR: 1.292, 95% CI: 1.100-1.517, p = 0.002; and conjugated bilirubin HR: 1.467, 95% CI: 1.216-1.768, p = 0.001. Corresponding analysis results for day 28 were alanine aminotransferase HR: 1.004, 95% CI: 1.002-1.006, p = 0.001; alkaline phosphatase HR: 1.005, 95% CI: 1.003-1.007, p = 0.001; total bilirubin HR: 1.233, 95% CI: 1.110-1.369, p = 0.001; and conjugated bilirubin HR: 1.272, 95% CI: 1.126-1.437, p = 0.001. Conclusions: Elevation of laboratory values early after LT is associated with ABS formation.

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • 제9권12호
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Somatotopic Mapping of the Supplementary Motor Area (부운동영역의 뇌지도화)

  • Han Young Min;Jeong Su-Hyun;Lee Heon;Jin Gong Yong;Lee Sang Yong;Chung Gyung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • 제8권1호
    • /
    • pp.9-16
    • /
    • 2004
  • Purpose : The purpose of this study was to assess supplementary motor area (SMA) activation during motor, sensory, word generation, listening comprehension, and working memory tasks using functional magnetic resonance imaging (fMRI). Materials and Methods : Sixteen healthy right-handed subjects (9M, 7F) were imaged on a Siemens 1.5T scanner. Whole brain functional maps were acquired using BOLD EPI sequences in the axial plane. Each paradigm consisted of five epochs of activation vs. the control condition. The activation tasks consisted of left finger complex movement, hot sensory stimulation of the left hand, word generation, listening comprehension, and working memory. The reference function was a boxcar waveform. Activation maps were thresholded at an uncorrected p=0.0001. The thresholded activation maps were placed into MNI space and the anatomic localization of activation within the SMA was compared across tasks. Results : SMA activation was observed in 16 volunteers for the motor task, 11 for the sensory task, 15 for the word generation task, 5 for the listening comprehension task, and 15 for the working memory task. The rostral aspects of the SMA showed activity during the word generation and working memory tasks, and the caudal aspects of the SMA showed activity during the motor and sensory tasks. Right (contralateral) SMA activation was observed during the motor and sensory tasks, and left SMA activation during the word generation and memory tasks. Conclusion : Our results suggest that SMA is involved in a variety of functional tasks including motor, sensory, word generation, and working memory. The results obtained also support the notion that functionally specific subregions exist within the region classically defined as the SMA.

  • PDF