• Title/Summary/Keyword: Imaging analysis

Search Result 2,909, Processing Time 0.047 seconds

Analysis of errors on the depth perception through binocular disparity in integral imaging

  • Kim, Joo-Hwan;Kim, Yun-Hee;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1322-1325
    • /
    • 2006
  • Integral imaging is a three-dimensional display method which has full parallax and continuous viewpoints. However, we found an error between the depth expressed by integral imaging and the depth perceived by the observer through binocular disparity. We analyze the depth perception errors of the threedimensional image constructed by integral imaging.

  • PDF

Surface Mass Imaging Technique for Nano-Surface Analysis

  • Lee, Tae Geol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.113-114
    • /
    • 2013
  • Time-of-flight secondary ion mass spectrometry (TOF-SIMS) imaging is a powerful technique for producing chemical images of small biomolecules (ex. metabolites, lipids, peptides) "as received" because of its high molecular specificity, high surface sensitivity, and submicron spatial resolution. In addition, matrix-assisted laser desorption and ionization time-of-flight (MALDI-TOF) imaging is an essential technique for producing chemical images of large biomolecules (ex. genes and proteins). For this talk, we will show that label-free mass imaging technique can be a platform technology for biomedical studies such as early detection/diagnostics, accurate histologic diagnosis, prediction of clinical outcome, stem cell therapy, biosensors, nanomedicine and drug screening [1-7].

  • PDF

Polarization Spectral Imaging System for Quantitative Evaluation of Port Wine Stain Blanching Following Laser Treatment

  • Jung, Byung-Jo
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.234-239
    • /
    • 2003
  • Objective methods to assess quantitatively port wine stain (PWS) blanching in response to laser therapy are needed to improve laser therapeutic outcome. Previous studies have attempted to assess objectively PWS color based on point measurement devices. To date, these approaches have typically been limited by a number of factors such as small test area and need for contact. To address these issues, a polarization spectral imaging system and an image analysis method have been developed to evaluate quantitatively erythema and melanin content distribution in skin. The developed polarization spectral imaging system minimizes artifacts such as glaring, shadowing, and non-uniform illumination that interfere with image fidelity. Furthermore, the image analysis method has been employed to get images of skin melanin and erythema indices from the acquired color images for quantitative analysis. Finally, using PWS patient color image, the effectiveness in laser treatment of PWS was evaluated by calculating relative erythema index image that is the relative erythema index of PWS region to the normal region. The developed device and analysis method appears to be a simple and effective method for quantitative analysis of PWS blanching.

3-D Image Reconstruction Techniques for Plant and Animal Morphological Analysis - A Review

  • Rahman, Anisur;Mo, Changyeun;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.339-349
    • /
    • 2017
  • Purpose: This review focuses on the major 3-D image reconstruction techniques and their applications in plant and animal morphological analysis. Methods & Results: This paper begins with an overview of major 3-D image reconstruction techniques and their basic principles. Subsequently, their applications in plant and animal morphological analysis are reviewed. A discussion on the limitations and future research direction of 3-D imaging techniques for accurate, fast measurements and modeling of plant and animal morphological analysis follows. Conclusions: Owing to the increasing demand for plant and animal morphological analysis, the application of 3-D imaging techniques will increase in popularity among researchers and the agricultural industry.

Linearized Methods for Quantitative Analysis and Parametric Mapping of Brain PET (뇌 PET 영상 정량화 및 파라메터영상 구성을 위한 선형분석기법)

  • Kim, Su-Jin;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.2
    • /
    • pp.78-84
    • /
    • 2007
  • Quantitative analysis of dynamic brain PET data using a tracer kinetic modeling has played important roles in the investigation of functional and molecular basis of various brain diseases. Parametric imaging of the kinetic parameters (voxel-wise representation of the estimated parameters) has several advantages over the conventional approaches using region of interest (ROI). Therefore, several strategies have been suggested to generate the parametric images with a minimal bias and variability in the parameter estimation. In this paper, we will review the several approaches for parametric imaging with linearized methods which include graphical analysis and mulilinear regression analysis.

Analysis and Evaluation of Slanted-edge-based Modulation Transfer Function and Focus Measurements for Optimal Assembly of Imaging Modules in Gastrointestinal Endoscopy

  • Wonju Lee;Ki Young Shin;Dong-Goo Kang;Minhye Chang;Young Min Bae
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.398-407
    • /
    • 2023
  • We explored a method to evaluate imaging performance for the optimal assembly of an endoscopic miniature lens and a sensor constituting an imaging module at the distal end of gastrointestinal endoscopy. For the assembly of the imaging module, the image sensor was precisely located at the focal plane when collimated light passed through the endoscopic lens. As another method, the distance between the lens and sensor was adjusted to obtain the highest focus index from images measured the star chart of the International Organization for Standardization (ISO) standard at various positions. We analyzed the slanted-edge modulation transfer function (MTF), corresponding depth of field, and number of line pairs for MTF 50% and 20% at each working distance within the range of 5-100 mm for imaging modules assembled in different ways. Assembly conditions of the imaging module with better MTF performance were defined for each working distance range of 5-30 mm and 30-100 mm, respectively. In addition to the MTF performance, the focus index of each assembled module was also compared. In summary, we examined the performance of imaging modules assembled with different methods within the suggested working distance and tried to establish the optimal assembly protocol.

Digital X-ray Imaging in Dentistry (치과에서 디지털 x-선 영상의 이용)

  • Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.387-396
    • /
    • 1999
  • In dentistry. RadioVisioGraphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter. many types of direct digital radiographic system have been produced in the last decade. They are based either on charge-coupled device(CCD) or on storage phosphor technology. In addition. new types of digital radiographic system using amorphous selenium. image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose. image processing, computer storage. electronic transfer of images and so on. Image processing includes image enhancement. image reconstruction. digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system(IMACS) for dentomaxillofacial radiology was reported in 1992. IMACS in dental hospital has been increasing. Meanwhile. researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible. feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis. have been performed actively in the last decade. Further developments in digital radiographic imaging modalities. image transmission system. imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  • PDF

Atomic Resolution Imaging of Rotated Bilayer Graphene Sheets Using a Low kV Aberration-corrected Transmission Electron Microscope

  • Ryu, Gyeong Hee;Park, Hyo Ju;Kim, Na Yeon;Lee, Zonghoon
    • Applied Microscopy
    • /
    • v.42 no.4
    • /
    • pp.218-222
    • /
    • 2012
  • Modern aberration-corrected transmission electron microscope (TEM) with appropriate electron beam energy is able to achieve atomic resolution imaging of single and bilayer graphene sheets. Especially, atomic configuration of bilayer graphene with a rotation angle can be identified from the direct imaging and phase reconstructed imaging since atomic resolution Moir$\acute{e}$ pattern can be obtained successfully at atomic scale using an aberration-corrected TEM. This study boosts a reliable stacking order analysis, which is required for synthesized or artificially prepared multilayer graphene, and lets graphene researchers utilize the information of atomic configuration of stacked graphene layers readily.

Imaging sub-salt structures (암염돔 하부 구조에 대한 구조보정 연구)

  • Shin, Chang-Soo;Ko, Seung-Won;Seo, Young-Tak;Pyun, Suk-Joon;Kim, Sung-Hoon;Ha, Wan-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.113-117
    • /
    • 2007
  • Sub-salt imaging is an unsolved hot issue in subsurface imaging area. We tested several important properties in imaging sub-salt structures to provide a clue to this problem. Reverse time migration using velocity models obtained by waveform inversion produced better results than that of stacking velocity analysis. Sub-salt imaging results were highly dependent on the size and shape of a salt structure. The results were not clear when the velocity of a salt structure is significantly higher than that of adjacent layers.

  • PDF