• 제목/요약/키워드: Imaging Processing Technique

검색결과 186건 처리시간 0.027초

고 자장 기능적 MR 영상을 이용한 뇌 운동 영역에서 산소 주입에 따른 활성화 영역에 관한 연구 (Cerebral Activation Area Following Oxygen Administration using a 3 Tesla Functional MR Imaging)

  • 구은회;권대철
    • 대한인간공학회지
    • /
    • 제24권4호
    • /
    • pp.47-53
    • /
    • 2005
  • This study aim to investigate the effects of supply of oxygen enhances cerebral activation through increased activation in the brain and using a 3 Tesla fMRI system. Five volunteers (right handed, average age of 21.3) were selected as subjects for this study. Oxygen supply equipment that provides 30% oxygen at a constant rate of 15L/min was given using face mask. A 3 Tesla fMRI system using the EPI BOLD technique, and three-pulse sequence technique get of the true axial planes scanned brain images. The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers. Complex movement consisted of a finger task in which subjects flexed and extended all fingers repeatedly in union, without the fingers touching each other. Both task consisted of 96 phases including 6 activations and rests contents. Post-processing was done on MRDx software program by using cross-correlation method. The result shows that there was an improvement in performance and also increased activation in several areas in the oxygen method. These finding demonstrates that while performing cognitive tasks, oxygen administration was due to increase of cerebral activation.

Quantitative analysis using decreasing amounts of genomic DNA to assess the performance of the oligo CGH microarray

  • Song Sunny;Lazar Vladimir;Witte Anniek De;Ilsley Diane
    • 한국생물정보학회:학술대회논문집
    • /
    • 한국생물정보시스템생물학회 2006년도 Principles and Practice of Microarray for Biomedical Researchers
    • /
    • pp.71-76
    • /
    • 2006
  • Comparative genomic hybridization (CGH) is a technique for studying chromosomal changes in cancer. As cancerous cells multiply, they can undergo dramatic chromosomal changes, including chromosome loss, duplication, and the translocation of DNA from one chromosome to another. Chromosome aberrations have previously been detected using optical imaging of whole chromosomes, a technique with limited sensitivity, resolution, quantification, and throughput. Efforts in recent years to use microarrays to overcome these limitations have been hampered by inadequate sensitivity, specificity and flexibility of the microarray systems. The oligonucleotide CGH microarray system overcomes several scientific hurdles that have impeded comparative genomic studies of cancer. This new system can reliably detect single copy deletions in chromosomes. The system includes a whole human genome microarray, reagents for sample preparation, an optimized microarray processing protocol, and software for data analysis and visualization. In this study, we determined the sensitivity, accuracy and reproducibility of the new system. Using this assay, we find that the performance of the complete system was maintained over a range of input genomic DNA from 5 ug down to 0.15 ug.

  • PDF

스마트 영상 장비를 위한 BCS-SPL 복호화 기법의 효과적인 고속화 방안 (An Effective Fast Algorithm of BCS-SPL Decoding Mechanism for Smart Imaging Devices)

  • 류중선;김진수
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.200-208
    • /
    • 2016
  • Compressed sensing is a signal processing technique for efficiently acquiring and reconstructing in an under-sampled (i.e., under Nyquist rate) representation. A block compressed sensing with projected Landweber (BCS-SPL) framework is most widely known, but, it has high computational complexity at decoder side. In this paper, by introducing adaptive exit criteria instead of fixed exit criteria to SPL framework, an effective fast algorithm is designed in such a way that it can utilize efficiently the sparsity property in DCT coefficients during the iterative thresholding process. Experimental results show that the proposed algorithm results in the significant reduction of the decoding time, while providing better visual qualities than conventional algorithm.

채광·조명설비시스템의 광학 분석을 위한 이미지 프로세싱 기법에 관한 연구 (Methodological study on the High Dynamic Range Imaging Processing)

  • 임홍수;김곤
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.3-8
    • /
    • 2010
  • Recently, various daylight evaluation methods for visual environment have been developed; simulation analysis methods, numerical calculation, and data monitoring methods. However, it is impossible for simulation analysis to make real scenes and visualize real images exactly. Also, a numerical calculation is considered as an out of date and time-consuming mean. Therefore, for acquisition of accurate results, many studies often use the monitoring data methods. Especially, most studies regarding discomfort glare are evaluated by measuring the physical quantity of luminance through traditional measuring Minolta Luminance meters as an instrument. But, this method has a difficulty in measuring several points at the same time because of the limitation of spaces and time when mapping. So, this study focused on the potential usefulness of High Dynamic Range photography technique as a luminance mapping tool. In order to evaluate the accuracy of proposed programs such as webHDR, Photomatix and PHOTOLUX, this paper has conducted an experiment by using Canon EOS 5D and NICON Coolpix8400 digital camera.

Analysis of Homomorphic Filtered Remotely Sensed Imagery and Multiple Geophysical Images

  • Ryu Hee-Young;Lee Kiwon;Kwon Byung-Doo
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.237-240
    • /
    • 2004
  • In this study, the digital image processing with image enhancement based on homomorphic filtering was performed using geophysical imaging data such as gravity, magnetic data and sub-scenes of satellite images such as LANDSAT, IKONOS, and KOMPSAT. Windows application program for executing homomorphic filtering was designed and newly implemented. In general, homomorphic filtering is technique that is based on Fourier transform, which enhances the contrast of image by removing the low frequencies and amplifying the high frequencies in frequency domain. We can enhance the image selectively using homomorphic filtering as compared with the existing method, which enhance the image totally. Through several experiment using remotely sensed imagery and geophysical image with this program, it is concluded that homomorphic filtering is more effective to reveal distinct characteristics for some complicated and multi-associated features on image data.

  • PDF

고양이 하부요로(下部尿路) 질환(疾患)의 X-선학적(線學的) 소견(所見)에 관한 연구(硏究) (Studies on the radiological observation of lower urinary tract disease of cats)

  • 신사경;나카가와 미츠요시;우치야마 히로시;미야하라 카즈로;사토 미토요시;김상근;히로세 쓰네오
    • 대한수의학회지
    • /
    • 제35권4호
    • /
    • pp.853-861
    • /
    • 1995
  • A total of 18 lower urinary tract disease(LUTD) cats were examined by radiographical finding. It is difficult of descend to particular on struvite crystal intraurinary bladder by the usual radiographical technique. However, we have lots of informations by imaging processing method on standing-up position radiograph. This method be helpful from now on LUTD research work.

  • PDF

초음파 현미경 시스템에 의한 B-스캔 영상처리 기술 (B-Scan Image Processing Technique by Using Ultrasonic Microscope System)

  • 고대식;전계석
    • 대한전자공학회논문지
    • /
    • 제27권12호
    • /
    • pp.1889-1893
    • /
    • 1990
  • In this paper, ultrasonic microscope system has been constructed with the small aperturre acoustic lens and the angle controller, and the new type of B-scanultransonic imaging has been analyzed. The system with small aperture lens was used to detect flaw existing within the thick specimen and its resolution was in the range of one wavelength at interior plane of sample. The anle controller was used to excited surface acoustic wave or shear wave. In order to obtain B-scan image of the flaw existig at interior of solids, shear wave has been excited and backscattering signals from the flaw have been processed. In experimental results, B-scan ultransonic images have been obtain from the flaws of varable shape and measured flaw size from the images has been in good agreement with practical size in the range of 10% error.

  • PDF

의공학적 기법에 의한 간암의 검진과 치료경과의 정량 : 칼만 필터링 기법에 의한 초음파 영상 처리 (Bioengineering Approaches to Quantitation of Diagnosis and Treatment Monitoring for Patients with Liver Cancer: Ultrasonic Image Processing by Kalman Filtering)

  • 우광방;남상일
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권1호
    • /
    • pp.5-12
    • /
    • 1985
  • In this paper Kalman filtering technique is applied to ultrasound signal to improve resolution capability, Ivhlch is in use of diagnostic imaging systems. The main advantage of Kalman filter algorithm for the analysis of reflected ultrasound signal is its recursive structure which can be easily adapted to tlme varing system. Because soft-tissues, such as liver, act as distributed acoustic low-pass filters which continually change the propagating pulse. tIne can put to practical use above advantage to find a suitable signal generallng model. In state-space description of the system, the 6th order system produces tl)e 1)esc spectral approximation to the source pulse As a result of spectrum analysis, 6th order estimator for two closely spaced ((p.5 mm) reflectors enhances resolution by 4dB-lOdB. By using this result, the possibility to detect even minute tumor is demonstrated.

  • PDF

라플라스 방정식의 해를 이용한 삼차원 의학 영상 랜더링 (Three Dimensional Medical Image Rendering Using Laplace's Equation)

  • 김상묵;안창범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2918-2920
    • /
    • 2000
  • A new multi-planar interpolation technique for three dimensional medical image rendering is proposed. In medical imaging. resolution in the slice direction is usually much lower than those in the transverse planes. The proposed method is based on the solution of the Laplace's equation used in the electrostatics. In this approach. two contours in the source and destination planes for a given object is assumed to have equi-potentials. Some preprocessing and post-processing including scaling. displacement. rotation from the centers of mass are involved in the algorithm. The interpolation solution assumes mostly smoothing changes in between the source and destination planes. Simultaneous multiple interpolation planes are inherently obtained in the proposed method. Some experimental and simulation results are shown.

  • PDF

미세 생체유동 해석을 위한 첨단 유동가시화기법 (Advanced Flow Visualization Techniques for Diagnosing Microscale Biofluid Flows)

  • 이상준
    • 대한기계학회논문집B
    • /
    • 제33권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Recently microscale biofluid flows have been receiving large attention in various research areas. However, most conventional imaging techniques are unsatisfactory due to difficulties encountered in the visualization of microscale biological flows. Recent advances in optics and digital image processing techniques have made it possible to develop several advanced micro-PIV/PTV techniques. They can be used to get quantitative velocity field information of various biofluid flows from visualized images of tracer particles. In this paper, as new advanced micro-PIV techniques suitable for biofluid flow analysis, the basic principle and typical applications of the time-resolved micro-PIV and X-ray micro-PIV methods are explained. As a 3D velocity field measurement technique for measuring microscale flows, holographic micro-PTV method is introduced. These advanced PIV/PTV techniques can be used to reveal the basic physics of various microscale biological flows and will play an important role in visualizing veiled biofluid flow phenomena, for which conventional methods have many difficulties to analyze.