• Title/Summary/Keyword: Imaging Plate

Search Result 231, Processing Time 0.028 seconds

Can pterygoid plate asymmetry be linked to temporomandibular joint disorders?

  • Guerrero, Maria Eugenia;Beltran, Jorge;de Laat, Antoon;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.89-94
    • /
    • 2015
  • Purpose: This study was performed to evaluate the relationship between pterygoid plate asymmetry and temporomandibular joint disorders. Materials and Methods: Cone-beam computed tomography (CBCT) images of 60 patients with temporomandibular disorders (TMD) involving pain were analyzed and compared with images of 60 age-and gender-matched controls. Three observers performed linear measurements of the lateral pterygoid plates. Results: Statistically significant differences were found between measurements of the lateral pterygoid plates on the site that had pain and the contralateral site (p<0.05). The average length of the lateral pterygoid plates (LPPs) in patients with TMD was $17.01{\pm}3.64mm$ on the right side and $16.21{\pm}3.51mm$ on the left side, and in patients without TMD, it was $11.86{\pm}1.97mm$ on the right side and $11.98{\pm}1.85mm$ on the left side. Statistically significant differences in the LPP length, measured on CBCT, were found between patients with and without TMD (p<0.05). The inter-examiner reliability obtained in this study was very high for all the examiners (0.99, 95% confidence interval: 0.98-0.99). Conclusion: Within the limits of the present study, CBCT lateral pterygoid plate measurements at the side with TMD were found to be significantly different from those on the side without TMD. More research is needed to explore potential etiological correlations and implications for treatment.

Verification of Periodical Calibration for Iso-center Positions using Quality Assurance System for Irradiation Equipment Position Established at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.192-194
    • /
    • 2002
  • We present the results on the calibration of iso-center positions using the quality assurance system established at PMRC for determination of center position in X-ray and proton irradiation fields. Details on the system are presented in another presentation in this session. The equipment in the system is mounted on a patient treatment bed in each proton exposure room, G1 or G2. A center of a stainless ball on the equipment is set at a cross of laser markers located around the iso-center and fixed on the room and on the snout in the gantry. A proton beam or an X-ray beam is exposed onto the ball through a brass collimator of 100 mm ${\times}$ 100 mm and projected onto the imaging plate set at I cm behind the ball. On the axis perpendicular to the thrust axis of the gantry on the imaging plate, a distance between a center of the collimator image and a center of the ball image varies as a cosine function of gantry angles unless the ball is set on the iso-center. An amplitude of the cosine curve shows the distance between the ball and the iso-center, an offset the offset of the collimator, and a phase shift at a zero crossing point the ball direction viewed from the iso-center. We present the relation among the iso-center position, the laser maker position, and the center of proton and X-ray irradiation fields. Its stability and its reproducibility are discussed.

  • PDF

Study of Acoustic Streaming at Resonance by Longitudinal Ultrasonic Vibration Using Particle Imaging Velocimetry (입자 영상 유속계를 이용한 초음파 수직진동에 의해 유도된 공진상태에서의 음향유동에 관한 연구)

  • 노병국;이동렬
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.340-352
    • /
    • 2004
  • Acoustic streaming induced by the microscopic longitudinal ultrasonic vibration at 28.5 ㎑ is visualized between the quiescent glass plate and ultrasonic vibrator by particle imaging velocimetry(PIV) using laser. To investigate the augmentation of air flow velocity of acoustic streaming. the velocity variations of air streaming between the stationary plate and ultrasonic vibrator are measured in real-time. It is experimentally investigated that the magnitude of the acoustic streaming dependent upon the gap between the ultrasonic vibrator and stationary p1ate results in the variations of the average velocity fields as a outcome of the bulk air flow caused by the ultrasonic vibration. In addition. maximum acoustic streaming velocity exists at resonant gap. 18mm that is one of the resonant gaps (H=18, 24, 30, 36㎜) at which resonance occurs. The variation of the local maximum turbulent intensity with axial direction appear to reveal the value of 8%∼70% dependent upon the gap between the quiescent glass plate and ultrasonic vibrator. Shearstress is also maximized at the center region of the vibrator and the vorticity is also maximum and minimum in the neighborhood of the center of the vibrator at which the local maximum turbulent intensity and shear stress exist.

On the Limitation of Telegrapher′s Equations for Analysis of Nonuniform Transmission Lines

  • Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.68-71
    • /
    • 2004
  • The limitation of telegrapher's equations for analysis of nonuniform transmission lines is investigated here. It is shown theoretically that the input impedance of a nonuniform transmission line cannot be derived uniquely from the Riccati equation only except for the exponential transmission line of a particular frequency-dependent taper. As an example, the input impedance of an angled two-plate transmission line is calculated by solving the telegrapher's equations numerically. The numerical results suffer from larger deviation from its rigorous solution as the plate angle increases.

Comparison Between Ultrasonic and X-ray Methods for Imaging the Children′s Growth Plate (어린이 성장판 영상화를 위한 초음파와 X-선 방식의 비교 평가)

  • Kim Sang Hoo;Kim Hyung Jun;Han Eun Ok;Han Seung Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.551-556
    • /
    • 2004
  • The purpose of this study was to suggest a systematic and scientific method for measurement of children's growth development, in which the accuracy of existing diagnosis method has not been concretely examined yet. The most popular method for diagnosis of children's growth is to analyze the opening degree of growth plate in each joint by X-ray image. However, X-ray method has some disadvantages; it is impossible to measure the diagnosis of growth periodically and repeatedly due to the radiation problem. Hence, this study introduced a profile analysis and the algorithm of analyzing the image of growth plate with the BUA(Broadband Ultrasound Attenuation) of calcaneus, to verify the possibility of alternative ultrasonic method harmless to human body. We obtained the images of growth plate in proximal tibiae, phalanges, and calcanei of 269 children (7∼16 years old) with X-ray. And the image of growth plate in calcanei was also obtained front those children with ultrasound. The results showed that the time of the opening degree of growth plate in each joint was almost consistent between X-ray and ultrasonic images. Also, the images of growth plate measured by X-ray and ultrasound showed the high correlation. Therefore, it is expected that the algorithm of ultrasonic profile analysis introduced in this study can replace the existing X-ray method to measure the growth plate correctly.

Contribution of Scattered X Rays to Signal Imaging with Anti-scatter Grids

  • Maeda, Koji;Arimura, Hidetaka;Morikawa, Kaoru;Kanamori, Hitoshi;Matsumoto, Masao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.404-406
    • /
    • 2002
  • We have investigated the contribution of the scattered x rays to the signal imaging in the radiographs acquired with anti-scatter grids of several grid ratios by separating the line spread functions (LSFs) derived from the signal edge image into the primary and the scatter components. By using a 1.0-mm lead plate in the scattering material, the blurred signal edge images were acquired by use of an imaging plate at a tube voltage of 80 kV with the anti-scatter grids of grid ratios for 5:1, 6:1, 8:1, 10:1 and 12:1. The edge profiles of the signal images were scanned and those in relative exposure were differentiated to obtain the LSFs. To investigate the contribution of the scattered x rays to the signal imaging, we proposed a method for separating the LSFs derived from the signal images into the primary and the scatter components, where the scatter component was approximated with exponential function. Our basic approach is to separate the area of the LSFs by ratios of the scattered x-ray exposure to the primary x-ray exposure, which were obtained for the grid ratios by use of a lead disk method. The LSFs and the two components were Fourier transformed to obtain the modulation transfer functions (MTFs) and their two components. As the result, we found that, by using the anti-scatter grids, the scattered x rays were reduced, but the shape of the LSFs of the scatter component hardly changed. The contributions of the scatter component to the MTFs were not negligible (more than 10 %) for spatial frequencies lower than about 1.0 mm$\^$-l/ and that was greater as the grid ratio decreasing. On the other hand, for higher frequencies, the primary component was dominant compared with the scatter component.

  • PDF

Structural Damage Detection by Using the Time-Reversal Process of Lamb Waves and the Imaging Method (Lamb파의 시간-반전과정 및 이미지기법을 이용한 손상탐지)

  • Jun, Yong-Ju;Lee, U-Sik
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.320-326
    • /
    • 2011
  • This paper proposes a baseline-free SHM technique in which the time-reversal process of Lamb waves and the imaging method are used. The proposed SHM technique has three distinct features when compared with the authors' previously proposed one: (1) It use the reconstructed signal for damage diagnosis, without need to extract the damage signal as the difference between reconstructed signal and initial input signal; (2) It use the imaging method based on the time-offlight information from the reconstructed signal, instead of using a pattern comparison method; (3) In order to make the damage image more clear, the modified mathematical definition of damage image in a pixel is used. The proposed SHM technique is evaluated through the damage detection experiment for an aluminum plate with damage at different locations.

Development and Application of Phased Array System for Defect Imaging in Plate-like Structures (평판 구조물의 영상화를 위한 위상 배열 시스템 개발 및 응용)

  • Lee, Joo Kyung;Kwon, Young Eui;Lee, Heung Son;Seung, Hong Min;Kim, Ki Yeon;Lee, Jun Kyu;Kim, Hoe Woong;Lee, Ho Cheol;Kim, Yoon Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.2
    • /
    • pp.123-130
    • /
    • 2014
  • An ultrasonic magnetostrictive transducer-based phased-array system for imaging defects in plate structures is newly proposed. In that most ultrasonic phased array systems rely on piezoelectric transducers or electromagnetic acoustic transducers, this system has its own unique feature of employing magnetostrictive transducers. Interest in using a phased array system using magnetostrictive transducers has been recently reported for pipe inspection but no such system has been developed for plate inspection. In this investigation, we aim to propose a phased array system using OL-MPTs (Omnidirectional Lamb wave Magnetostrictive Patch Transducers) for plate inspection. The developed system consists of a multi-channel function generator, power amplifiers, preamplifiers and a data acquisition unit. In the process of its development, each of the units must be checked and in doing so, we suggest types of ultrasonic wave experiments that should be carried out. Finally, the phased system using a transducer array composed of eight OL-MPTs is newly configured and is applied for actual crack detection experiments.