• Title/Summary/Keyword: Imaging Markers

Search Result 114, Processing Time 0.052 seconds

Gold and silver plasmonic nanoprobes trace the positions of histone codes

  • Choi, Inhee;Song, Jihwan;Park, Hyunsung
    • BMB Reports
    • /
    • v.55 no.3
    • /
    • pp.111-112
    • /
    • 2022
  • We visualized the distribution of heterochromatin in a single nucleus using plasmonic nanoparticle-conjugated H3K9me3 and H3K27me3 antibodies. Due to distance-dependent plasmonic coupling effects between nanoprobes, their scattering spectra shift to longer wavelengths as the distance between heterochromatin histone markers reduced during oncogene-induced senescence (OIS). These observations were supported by simulating scattering profiles based on considerations of particle numbers, interparticle distances, and the spatial arrangements of plasmonic nanoprobes. Using this plasmon-based colourimetric imaging, we estimated changes in distances between H3K9me3 and H3K27me3 during the formation of senescence-associated heterochromatin foci in OIS cells. We anticipate that the devised analytical technique combined with high-spatial imaging and spectral simulation will eventually lead to a new means of diagnosing and monitoring disease progression and cellular senescence.

Quantitative Analysis of Thyroid Blood Flow and Static Imaging in the Differential Diagnosis of Thyroid Nodules

  • Song, Li-Ping;Zhang, Wen-Hong;Xiang, Yang;Zhao, Na
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6331-6335
    • /
    • 2013
  • Objective:To evaluate the performance of combined quantitative analysis of thyroid blood flow and static imaging data in the differential diagnosis of thyroid nodules. Method: Thyroid blood flow and static imaging were performed in 165 patients with thyroid nodules. Patients were divided into a benign thyroid nodule group (BTN, n=135) and a malignant thyroid nodule group (MTN, n=30) based on the results of post-surgical pathologic examination. Carotid artery thyroid transit times (CTTT), perfusion ratio of thyroid nodule blood/thyroid blood (TNB/TB), and perfusion ratio of thyroid nodule blood/carotid artery blood (TNB/CAB) were measured using thyroid blood flow imaging. The ratios between thyroid nodule and ipsilateral submandibular gland (TN/SG) and thyroid nodule and normal thyroid tissue (TN/T) were measured from thyroid static imaging. The differences between the BTN and MTN groups were compared. Results: 1) CTTT was markedly lower in the MTN group than the BTN group, the difference being statistically significant. 2) TNB/TB and TNB/CAB were both significantly higher in MTN than BTN groups. 3) TN/T was significantly lower in MTN group than BTN group. 4) TN/SG was lower in MTN group than BTN group, but the difference was not statistically significant. 5) Using the combination of CTTT and TN/T, the sensitivity, specificity and accuracy were 93.1%, 95.3% and 94.9% respectively for the diagnosis of MTN. Using the combination of CTTT, TNB/TB and TN/T, the sensitivity, specificity and accuracy changed to 89.7%, 100%, and 98.1% respectively. 6) Correlation analysis demonstrated a significant correlation between TN/T and TNB/TB (r=-0.384, P=0.036) and TNB/CAB (r=-0.466, P=0.009) in the MTN group. Conclusion: The combination of quantitative markers from thyroid blood flow and thyroid static imaging had high specificity and accuracy in differential diagnosis of benign and malignant thyroid nodules, thus providing an important imaging diagnostic approach.

Constrained High Accuracy Stereo Reconstruction Method for Surgical Instruments Positioning

  • Wang, Chenhao;Shen, Yi;Zhang, Wenbin;Liu, Yuncai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.10
    • /
    • pp.2679-2691
    • /
    • 2012
  • In this paper, a high accuracy stereo reconstruction method for surgery instruments positioning is proposed. Usually, the problem of surgical instruments reconstruction is considered as a basic task in computer vision to estimate the 3-D position of each marker on a surgery instrument from three pairs of image points. However, the existing methods considered the 3-D reconstruction of the points separately thus ignore the structure information. Meanwhile, the errors from light variation, imaging noise and quantization still affect the reconstruction accuracy. This paper proposes a method which takes the structure information of surgical instruments as constraints, and reconstructs the whole markers on one surgical instrument together. Firstly, we calibrate the instruments before navigation to get the structure parameters. The structure parameters consist of markers' number, distances between each markers and a linearity sign of each instrument. Then, the structure constraints are added to stereo reconstruction. Finally, weighted filter is used to reduce the jitter. Experiments conducted on surgery navigation system showed that our method not only improve accuracy effectively but also reduce the jitter of surgical instrument greatly.

Radiopaque markers and hydrogram in feline alimentary lymphoma

  • Choi, Jihye;Lee, Jinsoo;Jang, Jaeyoung;Choi, Heeyeon;Seo, Jimin;Lee, Minjung;Kim, Hyunwook
    • Korean Journal of Veterinary Research
    • /
    • v.52 no.2
    • /
    • pp.147-151
    • /
    • 2012
  • Radiography, ultrasonography with hydrogram, and contrast studies using radiopaque markers were applied to evaluate alimentary lymphoma in two cats. The hydrogram facilitated the differentiation of pseudo-thickening from true wall thickening, and enabled an evaluation of wall layering and lymph nodes. In case 1, mechanical obstruction of the duodenum was confirmed with barium-impregnated polyethylene spheres (BIPS), a radiopaque marker; however, results obtained in case 2 were not as definitive. We expect that hydrograms and BIPS can be used as valuable alternative methods to evaluate the gastrointestinal (GI) tract although further studies in cases involving GI tumors are needed.

Fluorescence Molecular Imaging

  • Choi, Heung-Kook;Ntziachristos, Vasilis;Weissleder, Ralph
    • Proceedings of the KSMRM Conference
    • /
    • 2004.09a
    • /
    • pp.23-32
    • /
    • 2004
  • The chemotherapy sensitive Lewis lung carcinoma (LLC) and chemotherapy resistant Lewis lung carcinoma (CR-LLC) tumors concurrently implanted in mice, and compare these findings with histological macroscopic observations against 3D reconstruction of Fluorescence Molecular Tomography (FMT) preformed in vivo on the same animals. For the 3D image reconstruction we used 32 laser source images, a flat image and 3D surface rendering that confused for 3D Fluorescence Molecular Imaging (FMI). A minimum of ten tissue sections were analyzed per tumor for quantification of the TUNEL-positive cells, cell-associated Cy5.5-Annexin and vessel-associated Alexa Fluor-Lectin. These are useful apoptosis and angiogenesis markers, and they serve as validation experiments to data obtained in vivousing a Cy5.5-Annexin V conjugate injected intravenously in chemotherapy-treated animals carrying the tumors studied histologically. We detected higher levels of apoptosis and corresponding higher levels of Cy5.5 fluorescence in the LLC vs. the CR-LLC tumors according to tissue depth and these findings confirm that in vivo staining with the Cy5.5-Annexing conjugate correlates well with in vitro TUNEL staining and is consistent with the higher apoptotic index expected from the LLC line. There appeared to be 1.38% more apoptosis for LLC than CR-LLC. Consequently there is good correlation between the histology results and in vivo fluorescence-mediated optical imaging. In conclusion the apoptotic images of 3D FMI were validated by microscopic histological image analysis. This is a significant result for the continuous progress of fluorescence 3D imaging research.

  • PDF

Accuracy of three-dimensional cephalograms generated using a biplanar imaging system

  • Park, Ha-Yeon;Lee, Jae-Seo;Cho, Jin-Hyoung;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • The korean journal of orthodontics
    • /
    • v.48 no.5
    • /
    • pp.292-303
    • /
    • 2018
  • Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on cone-beam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D $Ceph^{TM}$ program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D $ceph_{biplanar}$), conventional radiography (3D $ceph_{conv}$), and CBCT (3D $ceph_{cbct}$). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland-Altman plotting. Results: There were no statistically significant differences between the 3D $ceph_{biplanar}$ and 3D $ceph_{cbct}$ measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D $ceph_{cbct}$ and 3D $ceph_{conv}$ measurements. However, the values obtained from 3D $ceph_{conv}$ showed larger deviations than those obtained from 3D $ceph_{biplanar}$. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

Clinical Implications of Focal Mineral Deposition in the Globus Pallidus on CT and Quantitative Susceptibility Mapping of MRI

  • Hyojin Kim;Jinhee Jang;Junghwa Kang;Seungun Jang;Yoonho Nam;Yangsean Choi;Na-young Shin;Kook-Jin Ahn;Bum-soo Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.7
    • /
    • pp.742-751
    • /
    • 2022
  • Objective: To assess focal mineral deposition in the globus pallidus (GP) by CT and quantitative susceptibility mapping (QSM) of MRI scans and evaluate its clinical significance, particularly cerebrovascular degeneration. Materials and Methods: This study included 105 patients (66.1 ± 13.7 years; 40 male and 65 female) who underwent both CT and MRI with available QSM data between January 2017 and December 2019. The presence of focal mineral deposition in the GP on QSM (GPQSM) and CT (GPCT) was assessed visually using a three-point scale. Cerebrovascular risk factors and small vessel disease (SVD) imaging markers were also assessed. The clinical and radiological findings were compared between the different grades of GPQSM and GPCT. The relationship between GP grades and cerebrovascular risk factors and SVD imaging markers was assessed using univariable and multivariable linear regression analyses. Results: GPCT and GPQSM were significantly associated (p < 0.001) but were not identical. Higher GPCT and GPQSM grades showed smaller gray matter (p = 0.030 and p = 0.025, respectively) and white matter (p = 0.013 and p = 0.019, respectively) volumes, as well as larger GP volumes (p < 0.001 for both). Among SVD markers, white matter hyperintensity was significantly associated with GPCT (p = 0.006) and brain atrophy was significantly associated with GPQSM (p = 0.032) in at univariable analysis. In multivariable analysis, the normalized volume of the GP was independently positively associated with GPCT (p < 0.001) and GPQSM (p = 0.002), while the normalized volume of the GM was independently negatively associated with GPCT (p = 0.040) and GPQSM (p = 0.035). Conclusion: Focal mineral deposition in the GP on CT and QSM might be a potential imaging marker of cerebral vascular degeneration. Both were associated with increased GP volume.

Recent Trends in Human Motion Detection Technology and Flexible/stretchable Physical Sensors: A Review

  • Park, Inkyu
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.391-396
    • /
    • 2017
  • Human body motion detection is important in several industry sectors, such as entertainment, healthcare, rehabilitation, and so on. In this paper, we first discuss commercial human motion detection technologies (optical markers, MEMS acceleration sensors, infrared imaging, etc.) and then explain recent advances in the development of flexible and stretchable strain sensors for human motion detection. In particular, flexible and stretchable strain sensors that are fabricated using carbon nanotubes, silver nanowires, graphene, and other materials are reviewed.

The Clinical Significance of Serum Ferritin in Pediatric Non-Alcoholic Fatty Liver Disease

  • Na, Ji Hoon;Park, So Won;Kang, Yunkoo;Koh, Hong;Kim, Seung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.17 no.4
    • /
    • pp.248-256
    • /
    • 2014
  • Purpose: Non-alcoholic fatty liver disease (NAFLD) in children has become an important public health issue because of its high prevalence and severity. Several noninvasive methods for estimating NAFLD are under investigation. We aimed to evaluate the usefulness of serum ferritin as a biomarker of severity of pediatric NAFLD patients. Methods: A total of 64 NAFLD patient were enrolled from Severance Children's Hospital from March 2010 to February 2013. Serum ferritin levels, liver related laboratory tests, liver magnetic resonance imaging (MRI) (2-dimensional [2D] proton density-fat fraction) and NAFLD severity markers were compared between obese group and overweight group. Correlation analyses were performed between serum ferritin and laboratory values including NAFLD severity markers. Results: In obese group, serum ferritin, alanine aminotransferase (ALT), total bilirubin, international normalized ratio (INR), MRI 2D proton density-fat fraction, aspartate aminotransferase (AST) to platelet ratio index (APRI) and fibrosis- 4 (FIB-4) (an index score calculated from platelet count, ALT, AST and age) were significantly higher than those of overweight group. NAFLD severity markers, APRI and FIB-4, and liver specific important laboratory values, AST, ALT, INR, cholesterol, triglyceride and low density lipoprotein show significant correlation with serum ferritin in NAFLD patients. Conclusion: Serum ferritin concentrations could be a candidate of useful severity marker in the pediatric NAFLD patients.