• 제목/요약/키워드: Imaging Markers

검색결과 120건 처리시간 0.028초

Recent Trends in Human Motion Detection Technology and Flexible/stretchable Physical Sensors: A Review

  • Park, Inkyu
    • 센서학회지
    • /
    • 제26권6호
    • /
    • pp.391-396
    • /
    • 2017
  • Human body motion detection is important in several industry sectors, such as entertainment, healthcare, rehabilitation, and so on. In this paper, we first discuss commercial human motion detection technologies (optical markers, MEMS acceleration sensors, infrared imaging, etc.) and then explain recent advances in the development of flexible and stretchable strain sensors for human motion detection. In particular, flexible and stretchable strain sensors that are fabricated using carbon nanotubes, silver nanowires, graphene, and other materials are reviewed.

The Clinical Significance of Serum Ferritin in Pediatric Non-Alcoholic Fatty Liver Disease

  • Na, Ji Hoon;Park, So Won;Kang, Yunkoo;Koh, Hong;Kim, Seung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제17권4호
    • /
    • pp.248-256
    • /
    • 2014
  • Purpose: Non-alcoholic fatty liver disease (NAFLD) in children has become an important public health issue because of its high prevalence and severity. Several noninvasive methods for estimating NAFLD are under investigation. We aimed to evaluate the usefulness of serum ferritin as a biomarker of severity of pediatric NAFLD patients. Methods: A total of 64 NAFLD patient were enrolled from Severance Children's Hospital from March 2010 to February 2013. Serum ferritin levels, liver related laboratory tests, liver magnetic resonance imaging (MRI) (2-dimensional [2D] proton density-fat fraction) and NAFLD severity markers were compared between obese group and overweight group. Correlation analyses were performed between serum ferritin and laboratory values including NAFLD severity markers. Results: In obese group, serum ferritin, alanine aminotransferase (ALT), total bilirubin, international normalized ratio (INR), MRI 2D proton density-fat fraction, aspartate aminotransferase (AST) to platelet ratio index (APRI) and fibrosis- 4 (FIB-4) (an index score calculated from platelet count, ALT, AST and age) were significantly higher than those of overweight group. NAFLD severity markers, APRI and FIB-4, and liver specific important laboratory values, AST, ALT, INR, cholesterol, triglyceride and low density lipoprotein show significant correlation with serum ferritin in NAFLD patients. Conclusion: Serum ferritin concentrations could be a candidate of useful severity marker in the pediatric NAFLD patients.

Metastatic Mature Teratoma and Growing Teratoma Syndrome in Patients with Testicular Non-Seminomatous Germ Cell Tumors

  • Daniel B. Green;Francisco G. La Rosa;Paul G. Craig;Francesca Khani;Elaine T. Lam
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1650-1657
    • /
    • 2021
  • Metastatic mature teratoma is a common radiologic and histopathologic finding after chemotherapy for metastatic non-seminomatous germ cell tumors. The leading theory for these residual tumors is the selective chemotherapy resistance of teratomas versus the high chemotherapy sensitivity of the embryonal components. Growing teratoma syndrome is a relatively rare phenomenon defined as an enlarging residual mass histologically proven to be a mature teratoma in the setting of normal serum tumor markers. Metastatic mature teratomas should be resected because of their malignant potential and occasional progression to growing teratoma syndrome with the invasion of the surrounding structures. CT is the preferred imaging modality for post-chemotherapy surveillance and should cover all sites of potential metastatic disease. This article reviews the clinical, pathologic, and multimodality imaging features of metastatic mature teratomas in patients with primary testicular non-seminomatous germ cell tumors.

자기공명영상검사 시 폐쇄공포증 완화를 위한 굴절안경의 유용성 평가 (Evaluation of the Usefulness of Refraction Glasses to Reduce Claustrophobia During Magnetic Resonance Imaging)

  • 전병천;정성훈;이상현;손지혜
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.421-426
    • /
    • 2018
  • Unlike the traditional Radiological examinations, Magnetic Resonance Imaging (MRI) does not cause any harm and high levels of Radiation to the human body. Furthermore, MRI is widely used owing to its ability to adapt to different situations. However, the MRI equipment creates noises from its mechanical parts, and its magnetic bore structure can cause anxiety and claustrophobia in patients. To relieve claustrophobia, commercial refraction glasses were provided to the participants in this study, and the changes in anxiety and claustrophobia were measured. The participants were 30 volunteers with claustrophobia. To measure anxiety, the participants were asked to answer a Visual Analogue Scale (VAS) questionnaire. The physical markers of discomfort included perspiration on the forehead or hands (46.7%), mild frowning (30.3%), and leg shaking (40.1%). The subjective markers of discomfort included dizziness (2.85% in the men and 1.75% in the women). Although fear and anxiety levels were observed to be higher in the men, the difference was not significant. Hence, it was determined that both men and women felt discomfort (p >0.5). The fear coefficient was observed to decrease from 7.67 prior to wearing refraction glasses to 2.42 after wearing refraction glasses (p<0.000). In addition, use of refraction glass decreased MRI aversion from 1.97 to 1.03 (p<0.000). It can be inferred that refraction glasses are beneficial to patients undergoing MRI.

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • 제53권1호
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

An MRI-Based Quantification for Correlation of Imaging Biomarker and Clinical Performance in Chronic Phase of Carbon Monoxide Poisoning

  • Lee, Aleum;Hwang, Ji-sun;Bae, Won-kyung;Park, Jai-soung;Goo, Dong Erk;Park, Sung-Tae
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.241-250
    • /
    • 2019
  • Purpose: The purpose of this study was to determine the relation between quantitative magnetic resonance imaging biomarkers, and clinical performances in chronic phase of carbon monoxide intoxication. Materials and Methods: Eighteen magnetic resonance scans and cognitive evaluations were performed, on patients with carbon monoxide intoxication in chronic phase. Apparent diffusion coefficient (ADC) ratios of affected versus unaffected centrum semiovale, and corpus callosum were obtained. Signal intensity (SI) ratios between affected centrum semiovale, and normal pons in T2-FLAIR (fluid-attenuated inversion recovery) images were obtained. The Mini-Mental State Exam, and clinical outcome scores were assessed. Correlation coefficients were calculated, between MRI and clinical markers. Patients were further classified into poor-outcome and good-outcome groups based on clinical performance, and imaging parameters were compared. T2-SI ratio of centrum semiovale was compared, with that of 18 sex-matched and age-matched controls. Results: T2-SI ratio of centrum semiovale was significantly higher in the poor-outcome group, than that in the good-outcome group and was strongly inversely correlated, with results from the Mini-Mental State Exam. ADC ratios of centrum semiovale were significantly lower in the poor outcome group than in the good outcome group, and were moderately correlated with the Mini-Mental State Exam score. Conclusion: A higher T2-SI and a lower ratio of ADC values in the centrum semiovale, may indicate presence of more severe white matter injury and clinical impairment. T2-SI ratio and ADC values in the centrum semiovale, are useful quantitative imaging biomarkers for correlation with clinical performance in individuals with carbon monoxide intoxication.

근치적 절제술을 시행한 위암 환자에서 종양 표지자의 임상적 의미 (Clinical Significance of Tumor Markers in Gastric Cancer Patients after Curative Resection)

  • 김사영;하태경;권성준
    • Journal of Gastric Cancer
    • /
    • 제9권3호
    • /
    • pp.136-142
    • /
    • 2009
  • 목적: 위암으로 진단받고 근치적 절제술을 시행받은 환자를 대상으로 수술 전 및 수술 후에 정기적으로 시행한 종양표지자(AFP, CEA, CA19-9, CA125)의 추적검사 결과를 분석하고 위암 재발의 조기진단과 관련한 임상적 의미를 판정하였다. 또한 종양 표지자의 위양성률과 비종양성 만성질환과의 연관성을 알아보았다. 대상 및 방법: 2003년 11월부터 2006년 11월까지 한양대학교병원에 위암으로 입원하여 근치적 절제술을 시행받은 환자 290명을 대상으로 후향적 연구를 시행하였다. CEA (정상 참고치: 5 ng/ml), CA19-9 (39 U/ml), AFP (7.0 ng/ml), CA125 (35 U/ml) 네 가지 종양표지자값을 측정하였다. 종양표지자값의 변화와 내시경적 검사를 통한 조직 검사나 방사선학적 검사를 통한 재발 여부와의 연관성을 분석하였다. 수술 후 종양의 재발은 없으나 종양표지자값이 정상 이상으로 상승한 위양성 환자에서 비종양성 만성 질환과의 연관성을 분석하였다. 결과: 재발과 관련하여 종양표지자 검사의 민감도, 특이도, 양성예측도, 음성예측도는 각각 75.0%, 64.6%, 23.1%, 94.8%였다. 재발이 발생한 36예 중 10예(27.8%)의 경우에서는 영상의학검사에서 재발이 발견되기 전 종양표지자의 상승이 먼저 나타났으며, 13예(36.1%)의 경우에서는 영상의학검사와 동시에 종양표지자의 상승이 나타났다 추적 기간 동안 재발이 발생하지 않은 254명 중 90명의 환자에서 적어도 한 가지 이상의 종양표지자가 상승하여 35.4%의 위양성를을 나타내었다. 재발의 증거가 없으나 종양표지자가 상승했던 90명의 환자 중에 70명의 환자는 추적 검사 상 수치가 정상화 되었으나(기간: $9.08\pm7.2$개월), 20명의 환자는 지속적으로 정상 수치 이상 유지되었다. 두 군 간의 성별, 나이, 성별, 림프절 전이 여부, 조직형, 병기 등의 차이는 없었으나 비종양성 만성 질환(폐질환, 간담도계 질환, 고혈압 당뇨, 흡연, 민간요법) 유무의 차이가 있었다. 만성 질환이 있는 군이 없는 군에 비해 종양표지자가 지속적으로 상승되어 있는 양상을 나타내었다(P=0.007). 결론: 위암 근치적 절제술 후 재발 진단의 목적으로 종양 표지자는 영상의학검사 등의 다른 검사와 병합하여 활용할 수 있을 것이다. 또한 비종양성 만성 질환이 있는 경우 종양표지자가 상승하는 경우도 있으므로 이에 대한 고려가 필요할 것이다.

  • PDF

다중 분자 영상을 위한 간편한 동물 특이적 자세 고정틀의 제작 (Facile Fabrication of Animal-Specific Positioning Molds For Multi-modality Molecular Imaging)

  • 박정찬;오지은;우승태;곽원정;이정은;김경민;안광일;최태현;천기정;장용민;이상우;안병철;이재태;유정수
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권5호
    • /
    • pp.401-409
    • /
    • 2008
  • 목적: 최근 들어, 분자 영상에서 다중 영상 기법이 널리 보급되고 있다. 우리는 PET/MR 융합 영상을 얻기 위해 쉽게 이용 가능한 점토와 순간 고형제를 이용하여 동물 특이적 자세 고정 틀을 제작하였다. 동물 특이적 자세 고정 틀은 동물의 고정과 재현성 있는 자세 연출이 가능하도록 한다. 여기에서 우리는 실험 동물의 틀을 제작하는데 있어 점토와 순간 고형제를 비교해 보았다. 재료 및 방법: MicroPET의 받침대와 잘 맞는 바닥이 둥근 아크릴 받침대를 먼저 제작하였다. 실험 동물은 마취 후, 자세 고정을 위해서 틀 위에 올려놓았다. 틀 제작을 위하여 순간 고형제와 점토가 사용되었다. 순간 고형제와 점토를 사용한 두 가지 경우 모두, 실험 동물의 자세 고정을 위하여 부드럽게 실험 동물을 눌러 위치를 잡았다. 위치가 잡혔으면, 쥐를 들어내고, 점토로 뜬 틀은 $60^{\circ}C$ 건조기에 넣어 두어 완전히 경화시켰다. 그리고 $[^{18}F]FDG$용액이 든 밀봉된 4개의 파이펫 팁을 기준 마커로 사용하였다. 실험 동물의 꼬리에 $[^{18}F]FDG$를 정맥 주사하여 microPET 스캔을 실시한 후, 동일한 실험동물을 순차적으로 MRI 스캔하였다. 결과: 다중 영상을 위하여 점토와 순간 고형제로 동물 특이적 자세 고정 틀을 제작하였다. MicroPET과 MRI를 통하여 기능적이고 해부학적인 영상을 얻었다. PET/MR 융합 영상은 무료로 이용 가능한 AMIDE 프로그램을 사용하여 획득할 수 있었다. 결론: 쉽게 이용 가능한 점토, 순간 고형제와 일회용 파이펫 팁을 사용하여 성공적으로 동물 특이적 자세 고정 틀을 제작할 수 있었다. 동물 특이적 자세 고정 틀 덕택으로, 적은 오차 범위 내에서 PET/MR 융합 영상을 얻을 수 있었다.

Role of Myocardial Extracellular Volume Fraction Measured with Magnetic Resonance Imaging in the Prediction of Left Ventricular Functional Outcome after Revascularization of Chronic Total Occlusion of Coronary Arteries

  • Yinyin Chen;Xinde Zheng;Hang Jin;Shengming Deng;Daoyuan Ren;Andreas Greiser;Caixia Fu;Hongxiang Gao;Mengsu Zeng
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.83-93
    • /
    • 2019
  • Objective: The purpose of this study was to prospectively investigate the value of the myocardial extracellular volume fraction (ECV) in predicting myocardial functional outcome after revascularization of coronary chronic total occlusion (CTO). Materials and Methods: Thirty patients with CTO underwent cardiovascular magnetic resonance (CMR) before and 6 months after revascularization. Three baseline markers of functional outcome were evaluated in the dysfunctional segments assigned to the CTO vessels: ECV, transmural extent of infarction (TEI), and unenhanced rim thickness (RIM). At the global level, the ECV values of the whole myocardium with and without a hyperenhanced region (global and remote ECV) were respectively measured. Results: In per-segment analysis, ECV was superior to TEI and RIM in predicting functional recovery (area under receiver operating characteristic curve [AUC]: 0.86 vs. 0.75 and 0.73, all p values < 0.010), and it emerged as the only independent predictor of regional functional outcome (odds ratio [OR] = 0.83, 95% confidence interval [CI]: 0.77-0.89; p < 0.001) independent of collateral circulation. In per-patient analysis, global baseline ECV was indicative of ejection fraction (EF) at the follow-up examination (β = -0.61, p < 0.001) and changes in EF (β = -0.57, p = 0.001) in multivariate regression analysis. A patient with global baseline ECV less than 30.0% (AUC, 0.93; sensitivity 94%, specificity 80%) was more likely to demonstrate significant EF improvement (OR: 0.38; 95% CI: 0.17-0.85; p = 0.019). Conclusion: Extracellular volume fraction obtained by CMR may provide incremental value for the prediction of functional recovery both at the segmental and global levels in CTO patients, and may facilitate the identification of patients who can benefit from revascularization.