• 제목/요약/키워드: Imaging, Three-Dimensional/methods

Search Result 322, Processing Time 0.037 seconds

Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles

  • Nikneshan, Sima;Aval, Shadi Hamidi;Bakhshalian, Neema;Shahab, Shahriyar;Mohammadpour, Mahdis;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.257-262
    • /
    • 2014
  • Purpose: This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Materials and Methods: Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., $0^{\circ}$), $+10^{\circ}$, $+12^{\circ}$, $-12^{\circ}$, and $-10^{\circ}$ with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. Results: The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of $-12^{\circ}$, -0.66 to -0.11 at $-10^{\circ}$, -0.51 to +0.19 at $0^{\circ}$, -0.64 to +0.08 at $+10^{\circ}$, and -0.64 to +0.1 at $+12^{\circ}$. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Conclusion: Changing the slice orientation in the range of $-12^{\circ}$ to $+12^{\circ}$ reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.

The Need for an Additional Pelvic CT in Cases of Acute Osseous Pelvic Injury that Has Already Been Diagnosed by Abdominal CT. (복부 전산화단층촬영 결과 진단된 급성 외상성 골반골 골절에서 추가적인 3차원 재구성 골반 전산화단층촬영이 필요한가?)

  • Kim, Byoung kwon;Shin, Dong Hyuk;Han, Sang Kuk;Choi, Pil Cho;Lee, Young Han;Park, Ha Young;Bae, Soo Ho;Song, Hyoung Gon
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.206-211
    • /
    • 2009
  • Purpose: Abdominal CT (computed tomography) is a principal diagnostic imaging modality for torso trauma at the Emergency Department (ED). When acute osseous pelvic injuries are detected by abdominal CT, additional three-dimensional (3D) reconstruction pelvic CT is often performed. We compared abdominal CT with pelvic CT to provide information about acute osseous pelvic injuries. Methods: A retrospective investigation of patients'electronic medical records during the five year period between January 1, 2004 and December 31, 2008 among Korean soldiers who underwent pelvic CT after abdominal CT at the ED was conducted. Axial images of abdominal CT were compared with axial images and 3D reconstruction images of pelvic CT. Results: Sixteen patients underwent subsequent pelvic CT after abdominal CT. Axial images of abdominal CT showed the same results in terms of fracture detection and classification when compared to axial images and 3D reconstruction images of pelvic CT. Pelvic CT (including 3D reconstruction images) followed by abdominal CT neither detected additional fracture nor changed the fracture type. Conclusion: This study has failed to show any superiority of pelvic CT (including 3D reconstruction images) over abdominal CT in detecting acute osseous pelvic injury. When 3D information is deemed be mandatory, 3D reconstructions of abdominal CT can be requested rather than obtaining an additional pelvic CT for 3D reconstruction.

Posterior Tibial Nerve Somatosensory Evoked Potentials Recorded on Subdural Electrodes around Paracentral Lobule (부중심소엽 주변 경막하 전극들에서 기록된 후경골신경 체성감각유발전위)

  • Seo, Dae Won
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.2
    • /
    • pp.112-117
    • /
    • 1999
  • Background : Posterior tibial nerve somatosensory evoked potentials (PTSEP) have cortical potentials on primary sensory area of foot around 40 msec. The direct cortical recordings of the cortical potentials shows high voltage positive wave on medial hemisphere, especially on paracentral lobule (PCL). However, it is so difficult to record the potential directly on PCL that the cortical potential of PTSEP is not well understood. We investigated the cortical potential of PTSEP on subdural electrodes. Methods : We recorded cortical potentials to posterior tibial nerve stimulation on subdural electrodes which were on medial hemisphere near PCL in 15 intractable neocortical epilepsy patients. The numbers of subdural electrodes were 8 in 10 subjects ($1{\times}8array$) and 16 in 5 subjects ($2{\times}8arrays$). Seven subjects had three-dimensional imaging fusion (3D-fusion) of MRI and the electrodes using Analyze program. We investigated the amplitude, latency, polarity, and phase of the waves regarding location. Results : The waves had maximal amplitude on PCL in 4 subjects, precuneus in 1, cingulate gyrus nearest to PCL in 2 among 7 subjects with 3D-fusion. Also the electrodes were located on posterior area of PCL (2 out of 2 subjects with more than two electrodes put on PCL in 3D-fusion) and superior area of it (5 out of 5 subjects with $2{\times}8arrays $). All the high (more than 20 uV) amplitude around 40msec had positive polarity in 7 subjects. The phase reversals were detected between the electrodes with the highest amplitude and the just posterior (2 subjects) or anterior (6 subjects) located electrodes. The just posterior located electrodes had sharper phase reversal than the anterior one. Conclusion : PTSEP might have maximal amplitude of cortical potentials on the more superior and posterior area of PCL. The highest amplitude potential has positivity. The wave with maximal amplitude could have phase reversal of cortical potentials with surrounding electrodes, especially shaper with posterior part than with anterior one.

  • PDF

Quantitative analysis of the TMJ movement with a new mandibular movement tracking and simulation system

  • Kim, Dae-Seung;Hwang, Soon-Jung;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Heo, Kyung-Hoe;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.38 no.4
    • /
    • pp.203-208
    • /
    • 2008
  • Purpose : The purpose of this study was to develop a system for the measurement and simulation of the TMJ movement and to analyze the mandibular movement quantitatively. Materials and Methods : We devised patient-specific splints and a registration body for the TMJ movement tracking. The mandibular movements of the 12 subjects with facial deformity and 3 controls were obtained by using an optical tracking system and the patient-specific splints. The mandibular part was manually segmented from the CT volume data of a patient. Three-dimensional surface models of the maxilla and the mandible were constructed using the segmented data. The continuous movement of the mandible with respect to the maxilla could be simulated by applying the recorded positions sequentially. Trajectories of the selected reference points were calculated during simulation and analyzed. Results : The selected points were the most superior point of bilateral condyle, lower incisor point, and pogonion. There were significant differences (P<0.05) between control group and pre-surgical group in the maximum displacement of left superior condyle, lower incisor, and pogonion in vertical direction. Differences in the maximum lengths of the right and the left condyle were 0.59${\pm}$0.30 mm in pre-surgical group and 2.69${\pm}$2.63 mm in control group, which showed a significant difference (P<0.005). The maximum of differences between lengths of the right and the left calculated during one cycle also showed a significant difference between two groups (P<0.05). Conclusion : Significant differences in mandibular movements between the groups implies that facial deformity have an effect on the movement asymmetry of the mandible. (Korean J Oral Maxillofac Radiol 2008; 38 : 203-8)

  • PDF

3D Digital Design Optimization Process Considering Constructability of Freeform Structure (비정형 구조물의 시공성을 고려한 3차원 디지털 설계 최적화 프로세스)

  • Ryu, Han-Guk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.5
    • /
    • pp.35-43
    • /
    • 2013
  • Nowadays the widely used media in architecture include visualizations, animations and three-dimensional models. 3D digital methods using active CAM(Computer Aided Manufacturing) and CNC(Computerized Numerical Control) imaging have been developed for accurate shape and 3D measurements in freeform buildings. In contrast to a conventional building using auto CAD system and others, the proposed digital optimization method is based on a combination of 3D numerical data and parametric 3D model for design and construction. The objective of this paper is therefore to present digital optimization process for constructability of freeform building. The method can be useful in the effective implementation of an error-proofing process of freeform building during design and construction phase. 3D digital coordinate data can be used effectively to identify correct size of structural and finish members and installation location of each members in construction field. In addition, architects, engineers and contractors can evaluate design, materials, constructability and identify error-proofing opportunities. Other project participants can also include representatives from all levels of management, departments as well as workers and key subcontractors' personnel, if necessary. The 3D digital optimization process is therefore appropriate to serious variations in freeform shape. For future study, the developed digital optimization method is necessary to be carried out to verify the robustness and accuracy for constructability in construction field.

A Study on the Dyadic Sorting method for the Regularization in DT-MRI (Dyadic Sorting 방법을 이용한 DT-MRI Regularization에 관한 연구)

  • Kim, Tae-Hwan;Woo, Jong-Hyung;Lee, Hoon;Kim, Dong-Youn
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.4
    • /
    • pp.30-39
    • /
    • 2010
  • Since Diffusion tensor from Diffusion Tensor Magnetic Resonance Imaging(DT-MRI) is so sensitive to noise, the principle eigenvector(PEV) calculated from Diffusion tensor could be erroneous. Tractography obtained from PEV could be deviated from the real fiber tract. Therefore regularization process is needed to eliminate noise. In this paper, to reduce noise in DT-MRI measurements, the Dyadic Sorting(DS) method as regularization of the eigenvalue and the eigenvector is applied in the tractography. To resort the eigenvalues and the eignevectors, the DS method uses the intervoxel overlap function which can measure the overlap between eigenvalue-eigenvector pairs in the $3\times3$ pixel. In this paper, we applied the DS method to the three-dimensional volume. We discuss the error analysis and numerical study to the synthetic and the experimental data. As a result, we have shown that the DS method is more efficient than the median filtering methods as much as 79.97%~83.64%, 85.62%~87.76% in AAE, AFA respectively for the corticospinal tract of the experimental data.

A Study on the Estimation of Calcaneal Width Using a Correlation of Calcaneal Length and Width (종골 길이와 너비의 상관관계를 이용한 종골 너비 추정에 관한 연구)

  • Chun, Dong-il;Hwang, Shu Chiang;Cho, Jae-ho;Choi, Sung-Woo;Kim, Yong Beom;Won, Sung Hun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.2
    • /
    • pp.61-65
    • /
    • 2017
  • Purpose: The purpose of this study was to determine the correlation and ratio between the calcaneal length and width for predicting the width of calcaneus. Materials and Methods: A total of 190 feet (190 patients) were included based on computed tomography scans. The length of calcaneus (CL) was measured on the line connecting the center of a circle tangent to the cortical margin in the anterior and posterior parts of the calcaneus in a sagittal plane (W1, W2). The width of the calcaneus was defined as the horizontal line of each part (W1, W2, W3) on the same axial plane. The relationship between the measurement was determined through a correlation analysis. The reliability was assessed based on intraclass correlation coefficients. Results: The CL and widths of calcaneus (W1, W2, W3) had a good positive correlation (r=0.848 [W1/CL], r=0.738 [W2/CL], r=0.769 [W3/CL]; p<0.001). The mean CL and widths ratios were 0.33 (W1/CL), 0.37 (W2/CL), and 0.37 (W3/CL). Using these ratios to estimate the widths by multiplying each ratio by the measured calcaneal length, we found a difference between the estimated calcaneal widths and the actual measured calcaneal widths values was 0.25 mm, 0.43 mm, and 0.16 mm. All measurements showed good-to-excellent inter- and intraobserver reliability. Conclusion: This study analyzed the correlation and ratio between the length and width of the calcaneus. The results will help orthopedic surgeons fixate screws in a stable manner to prevent iatrogenic injuries to the medial neurovascular structures of the calcaneus.

Assessment of bone density changes following two-jaw surgery using multidetector computed tomography: A pilot study

  • Lee, Youngjoo;Park, Jae Hyun;Chang, Na-Young;Lee, Mi-Young;Kim, Bong Chul;Seo, Hye Young;Mangal, Utkarsh;Chae, Jong-Moon
    • The korean journal of orthodontics
    • /
    • v.50 no.3
    • /
    • pp.157-169
    • /
    • 2020
  • Objective: The aim of this retrospective study was to evaluate the pre- and postsurgical bone densities at alveolar and extra-alveolar sites following two-jaw orthognathic surgery. Methods: The sample consisted of 10 patients (mean age, 23.2 years; range, 18.0-27.8 years; 8 males, 2 females) who underwent two-jaw orthognathic surgery. A three-dimensional imaging program (Invivo 5) was used with multidetector computed tomography images taken pre- and postoperatively (obtained 32.3 ± 6.0 days before surgery and 5.8 ± 2.6 days after surgery, respectively) for the measurement of bone densities at the following sites: (1) alveolar bone in the maxilla and mandible, (2) extra-alveolar sites, such as the top of the head, menton (Me), condyle, and the fourth cervical vertebrae (C4). Results: When pre- and postsurgical bone densities were compared, an overall tendency of decrease in bone density was noted. Statistically significant reductions were observed in the densities of cancellous bone at several areas of the maxillary alveolar bone; cortical and cancellous bone in most areas of the mandibular alveolar bone; cortical bone in Me; and cancellous bone in C4. There was no statistically significant difference in bone density in relation to the depth of the alveolar bone. In a comparison of the bone densities between groups with and without genioplasty, there was almost no statistically significant difference. Conclusions: Accelerated tooth movement following orthognathic surgery may be confirmed with reduced bone density. In addition, this study could offer insights into bone metabolism changes following orthognathic surgery, providing direction for further investigations in this field.

Development and application of stent-based image guided navigation system for oral and maxillofacial surgery (구강외과 수술용 스텐트 기반 영상유도 수술 시스템의 개발)

  • Lee, Woo-Jin;Kim, Dae-Seung;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Myung-Jin;Lee, Jee-Ho
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose : The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. Materials and Methods : We devised a patient-specific stent for patient-to-image registration and navigation. Three-dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. Results : The accuracy over 8 anatomical landmarks showed an overall mean of $0.56{\pm}0.16\;mm$. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. Conclusion : The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  • PDF

Volume and Mass Doubling Time of Lung Adenocarcinoma according to WHO Histologic Classification

  • Jung Hee Hong;Samina Park;Hyungjin Kim;Jin Mo Goo;In Kyu Park;Chang Hyun Kang;Young Tae Kim;Soon Ho Yoon
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.464-475
    • /
    • 2021
  • Objective: This study aimed to evaluate the tumor doubling time of invasive lung adenocarcinoma according to the International Association of the Study for Lung Cancer (IASLC)/American Thoracic Society (ATS)/European Respiratory Society (ERS) histologic classification. Materials and Methods: Among the 2905 patients with surgically resected lung adenocarcinoma, we retrospectively included 172 patients (mean age, 65.6 ± 9.0 years) who had paired thin-section non-contrast chest computed tomography (CT) scans at least 84 days apart with the same CT parameters, along with 10 patients with squamous cell carcinoma (mean age, 70.9 ± 7.4 years) for comparison. Three-dimensional semiautomatic segmentation of nodules was performed to calculate the volume doubling time (VDT), mass doubling time (MDT), and specific growth rate (SGR) of volume and mass. Multivariate linear regression, one-way analysis of variance, and receiver operating characteristic curve analyses were performed. Results: The median VDT and MDT of lung cancers were as follows: acinar, 603.2 and 639.5 days; lepidic, 1140.6 and 970.1 days; solid/micropapillary, 232.7 and 221.8 days; papillary, 599.0 and 624.3 days; invasive mucinous, 440.7 and 438.2 days; and squamous cell carcinoma, 149.1 and 146.1 days, respectively. The adjusted SGR of volume and mass of the solid-/micropapillary-predominant subtypes were significantly shorter than those of the acinar-, lepidic-, and papillary-predominant subtypes. The histologic subtype was independently associated with tumor doubling time. A VDT of 465.2 days and an MDT of 437.5 days yielded areas under the curve of 0.791 and 0.795, respectively, for distinguishing solid-/micropapillary-predominant subtypes from other subtypes of lung adenocarcinoma. Conclusion: The tumor doubling time of invasive lung adenocarcinoma differed according to the IASCL/ATS/ERS histologic classification.