• Title/Summary/Keyword: Imaging, Three Dimensional

Search Result 710, Processing Time 0.026 seconds

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

Optical Tracking of Three-Dimensional Brownian Motion of Nanoparticles

  • Choi C. K.;Kihm K.D.
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.3-19
    • /
    • 2005
  • Novel optical techniques are presented for three-dimensional tracking of nanoparticles; Optical Serial Sectioning Microscopy (OSSM) and Ratiometric Total Internal Reflection Fluorescent Microscopy (R-TIRFM). OSSM measures optically diffracted particle images, the so-called Point Spread Function (PSF), and dotermines the defocusing or line-of-sight location of the imaged particle measured from the focal plane. The line-of-sight Brownian motion detection using the OSSM technique is proposed in lieu of the more cumbersome two-dimensional Brownian motion tracking on the imaging plane as a potentially more effective tool to nonintrusively map the temperature fields for nanoparticle suspension fluids. On the other hand, R-TIRFM is presented to experimentally examine the classic theory on the near-wall hindered Brownian diffusive motion. An evanescent wave field from the total internal reflection of a 488-nm bandwidth of an argon-ion laser is used to provide a thin illumination field of an order of a few hundred nanometers from the wall. The experimental results show good agreement with the lateral hindrance theory, but show discrepancies from the normal hindrance theory. It is conjectured that the discrepancies can be attributed to the additional hindering effects, including electrostatic and electro-osmotic interactions between the negatively charged tracer particles and the glass surface.

  • PDF

4D Reconstruction of Cine Cardiac MR Images (심장 자기공명영상의 4차원 재구성)

  • Lee, D.H.;Kim, J.H.;Song, I.C.;Cho, S.S.;Park, J.H.;Han, M.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.314-316
    • /
    • 1996
  • To diagnose cardiac malfunctions, various imaging techniques have been applied to heart : DSA(Digital Subtracted Angiography), Doppler Ultrasound, MR Angio. But it is difficult to observe three dimensional heart motion which is the most intuitive tool for diagnosis, only by using these methods. In this research, we have suggested 4-Dimensional reconstruction scheme of heart motion images that can be acquired by ECG-gated cine MR imaging. One cardiac cycle was devided into $9\sim15$ phases and for each phase 3D reconstructed volumn heart was made. We can observe 3D volumns along the cardiac cycle, time. So the results were 4-D reconstructed data.

  • PDF

A novel method for cell counting of Microcystis colonies in water resources using a digital imaging flow cytometer and microscope

  • Park, Jungsu;Kim, Yongje;Kim, Minjae;Lee, Woo Hyoung
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.397-403
    • /
    • 2019
  • Microcystis sp. is one of the most common harmful cyanobacteria that release toxic substances. Counting algal cells is often used for effective control of harmful algal blooms. However, Microcystis sp. is commonly observed as a colony, so counting individual cells is challenging, as it requires significant time and labor. It is urgent to develop an accurate, simple, and rapid method for counting algal cells for regulatory purposes, estimating the status of blooms, and practicing proper management of water resources. The flow cytometer and microscope (FlowCAM), which is a dynamic imaging particle analyzer, can provide a promising alternative for rapid and simple cell counting. However, there is no accurate method for counting individual cells within a Microcystis colony. Furthermore, cell counting based on two-dimensional images may yield inaccurate results and underestimate the number of algal cells in a colony. In this study, a three-dimensional cell counting approach using a novel model algorithm was developed for counting individual cells in a Microcystis colony using a FlowCAM. The developed model algorithm showed satisfactory performance for Microcystis sp. cell counting in water samples collected from two rivers, and can be used for algal management in fresh water systems.

Three-dimensional cone-beam computed tomographic sialography in the diagnosis and management of primary Sjögren syndrome: Report of 3 cases

  • Thomas, Nithin;Kaur, Aninditya;Reddy, Sujatha S.;Nagaraju, Rakesh;Nagi, Ravleen;Shankar, Vidya Gurram
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.209-216
    • /
    • 2021
  • Sjögren syndrome is a chronic autoimmune inflammatory disease characterized by lymphocytic infiltration of exocrine glands, predominantly the parotid and lacrimal glands, thereby resulting in oral and ocular dryness. It has been reported to occur most frequently in women between 40 and 50 years of age. Sjögren syndrome has an insidious onset, is slowly progressive, and presents a wide range of clinical manifestations, leading to delays or challenges in the diagnosis. Early diagnosis of this condition is essential to prevent the associated complications that affect patients' quality of life. This report presents 3 cases of Sjögren syndrome in female patients aged between 40 and 75 years who presented with complaints of persistent dry mouth and burning sensation. The cases highlight the diagnostic value of 3-dimensional cone-beam computed tomographic sialography in the detection of salivary gland pathologies at an early stage.

Clinical assessment of various imaging systems for dental plaque scoring after the use of 3 different toothpastes

  • Simge Meseli;Sergen Ekenel;Bora Korkut;Burak Aksu;Dilek Tagtekin;Funda Yanikoglu
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.209-216
    • /
    • 2023
  • Purpose: This study was conducted to compare dental plaque scores obtained through clinical examinations and various imaging techniques, as well as to assess the effectiveness of herbal and conventional toothpastes for plaque removal. Materials and Methods: Thirty volunteers were divided into 3 groups. Each group was given a different toothpaste (from 2 herbal toothpastes and a conventional toothpaste) with which to brush their teeth for 21 days. Both initially and after brushing, dental plaque samples were collected, and plaque on the buccal surfaces of anterior teeth was scored using several imaging systems after staining with a disclosing agent. Specifically, digital dental photography, intraoral digital scanning, and FluoreCam imaging were employed to capture intraoral images. The Turesky Modified Quigley-Hein Plaque Index was used for clinical examination and image analysis. Quantitative polymerase chain reaction analyses and correlational assessments between clinical examination and imaging scores were conducted before and after toothpaste use. The Shapiro-Wilk test and Pearson correlations were utilized. Results: The lowest mean value was observed in the clinical examination without staining, while the highest was obtained using the FluoreCam method. No significant change was found in the level of any microorganism assessed following toothpaste use (P<0.05), with the exception of a decrease in S. mutans levels after using conventional toothpaste (P<0.05). Conclusion: Herbal toothpaste demonstrated plaque-removal effectiveness comparable to that of conventional toothpaste. The use of imaging methods for measuring plaque index has been suggested as a means to educate patients about plaque control and promote ongoing oral care.

A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography

  • Lee, Hee Jin;Lee, Sungeun;Lee, Eun Joo;Song, In Ja;Kang, Byung-Cheol;Lee, Jae-Seo;Lim, Hoi-Jeong;Yoon, Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • Purpose: Facial asymmetry has been measured by the severity of deviation of the menton (Me) on posteroanterior (PA) cephalograms and three-dimensional (3D) computed tomography (CT). This study aimed to compare PA cephalograms and 3D CT regarding the severity of Me deviation and the direction of the Me. Materials and Methods: PA cephalograms and 3D CT images of 35 patients who underwent orthognathic surgery (19 males and 16 females, with an average age of $22.1{\pm}3.3years$) were retrospectively reviewed in this study. By measuring the distance and direction of the Me from the midfacial reference line and the midsagittal plane in the cephalograms and 3D CT, respectively, the x-coordinates ($x_1$ and $x_2$) of the Me were obtained in each image. The difference between the x-coordinates was calculated and statistical analysis was performed to compare the severity of Me deviation and the direction of the Me in the two imaging modalities. Results: A statistically significant difference in the severity of Me deviation was found between the two imaging modalities (${\Delta}x=2.45{\pm}2.03mm$, p<0.05) using the one-sample t-test. Statistically significant agreement was observed in the presence of deviation (k=0.64, p<0.05) and in the severity of Me deviation (k=0.27, p<0.05). A difference in the direction of the Me was detected in three patients (8.6%). The severity of the Me deviation was found to vary according to the imaging modality in 16 patients (45.7%). Conclusion: The measurement of Me deviation may be different between PA cephalograms and 3D CT in some patients.

Analysis on the viewing characteristics of integral floating display

  • Min, Sung-Wook;Kim, Joo-Hwan;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1733-1736
    • /
    • 2007
  • Integral floating is three-dimensional display technique which is a combination of integral imaging and floating display. In this paper, we explain and analyze the relation between the special viewing characteristics and the system factors of integral floating system. The experimental results which prove the analysis will be presented.

  • PDF

Molecular Structure of Muscle Filaments Determined by Electron Microscopy

  • Craig, Roger
    • Applied Microscopy
    • /
    • v.47 no.4
    • /
    • pp.226-232
    • /
    • 2017
  • Electron microscopy and X-ray diffraction have together played a key role in our understanding of the molecular structure and mechanism of contraction of muscle. This review highlights the role of electron microscopy, from early insights into thick and thin filament structure by negative staining, to studies of single myosin molecule structure, and finally to recent high-resolution structures by cryo-electron microscopy. Muscle filaments are designed for movement. Their labile structures thus present challenges to obtaining near-atomic detail, which are also discussed.

Three-dimensional display by using integral imaging system (집적결상계를 이용한 3차원 입체영상 표시기)

  • 신승호
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.236-237
    • /
    • 2003
  • 3차원 영상표시를 위한 방법은 여러 가지 방향에서 연구되어 왔다. 이중 홀로그램을 이용한 방법은 완벽한 3차원 영상을 표현할 수 있지만 스페클 잡음이 나타나고 시야각이 제한되며 단색 간섭성 광원을 사용해야하는 등의 문제점이 있어 실제 응용에 제한을 받고 있다. 이에 따라 최근 들어 쌍안 방식을 포함한 3차원 입체영상의 구현을 위한 다양한 연구가 활발하게 수행되고 있다. 렌즈 어레이를 이용한 집적결상의 방법도 그 중의 하나로 완벽한 색상의 구현, 연속적 시야각 확보, 단순한 광학계에서 구현가능 등의 장점이 있어 응용 가능성이 매우 높은 방법 중 하나로 평가되고 있다. (중략)

  • PDF