• 제목/요약/키워드: Image volumes

검색결과 148건 처리시간 0.024초

Comparison of the Quality of Various Polychromatic and Monochromatic Dual-Energy CT Images with or without a Metal Artifact Reduction Algorithm to Evaluate Total Knee Arthroplasty

  • Hye Jung Choo;Sun Joo Lee;Dong Wook Kim;Yoo Jin Lee;Jin Wook Baek;Ji-yeon Han;Young Jin Heo
    • Korean Journal of Radiology
    • /
    • 제22권8호
    • /
    • pp.1341-1351
    • /
    • 2021
  • Objective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. Materials and Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. Results: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. Conclusion: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.

심층 컨볼루션 신경망을 이용한 OCT 볼륨 데이터로부터 AMD 진단 (AMD Identification from OCT Volume Data using Deep Convolutional Neural Network)

  • 권오흠;정유진;송하주
    • 한국멀티미디어학회논문지
    • /
    • 제20권8호
    • /
    • pp.1291-1298
    • /
    • 2017
  • Optical coherence tomography (OCT) is the most common medical imaging device with the ability to image the retina in eyes at micrometer resolution and to visualize the pathological indicators of many retinal diseases such as Age-Related Macular Degeneration (AMD) and diabetic retinopathy. Accordingly, there have been research activities to analyze and process OCT images to identify those indicators and make medical decisions based on the findings. In this paper, we use a deep convolutional neural network for analysis of OCT volume data to distinguish AMD from normal patients. We propose a novel approach where images in each OCT volume are grouped together into sub-volumes and the network is trained by those sub-volumes instead of individual images. We conducted an experiment using public data set to evaluate the performance of the proposed approach. The experiment confirmed performance improvement of our approach over the traditional image-by-image training approach.

Fully Automatic Segmentation and Volumetry on Brain MRI of Coronal Section

  • Sung, Yun-Chang;Song, Chang-Jun;Noh, Seung-Moo;Park, Jong-Won
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.441-445
    • /
    • 2000
  • This study is to segment white matter, gray matter, and cerebrospinal fluid(CSF) on a brain MR image of coronal section and to calculate the volume of each. First, we segmented the whole region of a brain from a black colored background, a skull and a fat layer. Then, we calculated the partial volume of each component, which was present in scanning finite thickness, with the arithmetical analysis of gray value from the internal region of a brain showing the blurring effects on the basis of the MR image forming principle. Calculated partial volumes of white matter, gray matter and CSF were used to determine the threshold for the segmentation of each component on a brain MR image showing the blurring effects. Finally, the volumes of segmented white matter, gray matter, and CSF were calculated. The result of this study can be used as the objective diagnostic method to determine the degree of brain atrophy of patients who have neurodegenertive diseases such as Alzheimer’s disease and cerebral palsy.

  • PDF

후리에 표시자를 이용한 포탈영상과 시뮬레이터 영상의 자동결합 (Automatic Image Matching of Portal and Simulator Images Using courier Descriptors)

  • 허수진
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.9-16
    • /
    • 1997
  • We develop an automatic imaging matching technique for combining portal image and simulator image for improvements in localization of treatment in radiation therapy. Fusion of images from two imaging modalities is treated as follows. We archive images thxough a frame-yabber. The simulator and portal images are edge detected and enhanced with interpolated adaptive histouam equalization and combined using geometrical parameters relating the coordinates of two image data sets which are calculated using Fourier descriptors. We don't use any kind of imaging markers for patient's convenience. clinical use of this image matching technique for treatment planning will result in improvements in localization of treatment volumes and critical structures. These improvements will allow greater sparing of normal tissues and more precise delivery of energy to the desired irradiation volume.

  • PDF

부분체적에 의해 번진 명암 값으로 표현된 뇌의 자기공명영상에 대한 영역분할 및 체적계산 (Region Segmentation and Volumetry of Brain MR Image represented as Blurred Gray Value by the Partial Volume Artifact)

  • 성윤창;송창준;노승무;박종원
    • 한국통신학회논문지
    • /
    • 제25권7A호
    • /
    • pp.1006-1016
    • /
    • 2000
  • 본 논문은 뇌의 자기공명영상에서 백질과 회백질 및 뇌척수액을 분리하고 각각의 체적을 산철하기 위한 것이다. 본 연구는 먼저 뇌의 자기공명영상에서 영상의 배경을 제거한 후 외피 및 지방층으로부터 뇌 영역 전체를 분리하였으며, 부분체적의 문제(partial volume artifact)에 의해 명암 값의 번짐 현상을 보이는 뇌의 내부 영역에서 자기 공명영상의 생성원리를 근거로 명암 값의 산술적인 해석을 통해 원래의 단면 안에 존재하던 각 성분의 부분체적을 산출하였다. 산출된 백질과 회백질 및 뇌척수액의 부분체적은 번짐 현상을 보이는 자기공명영상에서 각 성분을 분리하기 위한 판별값을 경정하기 위해 사용되었고, 최종적으로 백질과 회백질 및 뇌척수액의 체적을 산출하도록 하였다. 본 연구는 뇌의 위축을 보이지 않는 정상인의 자기공명영상을 대상으로 하였으며, 향후 이러한 연구 결과는 알쯔하이머 병이나 뇌성마비등과 같은 퇴행성 뇌 질환 환자의 뇌 위축정도를 객관적으로 진단하는 방법으로 사용 될 수 있다.

  • PDF

호흡동조전산화단층촬영과 콘빔전산화단층촬영의 팬텀 영상 체적비교 (Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom)

  • 김성은;원희수;홍주완;장남준;정우현;최병돈
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.123-130
    • /
    • 2016
  • 목 적 : Computerized imaging reference systems 동적팬텀을이용한 cone-beamcomputed tomography(CBCT) 영상과 four-dimensionalcomputed tomography(4DCT) 영상의 체적을 비교분석 하고자 한다. 대상 및 방법 : 동적팬텀 내에 직경 1, 2, 3 cm 노드를 각각 삽입하고, CT simulator와 TruebeamSTx X-ray Imaging system을 이용하여 4DCT 영상과 CBCT 영상을 얻었다. 4DCT 영상은 maximum intensity projection(MIP), minimum intensity projection(MinIP), 그리고 average intensity projection(AVG)영상으로 재구성 하고 노드의 체적은 Eclipse system의 CT ranger tool로 CT number를 설정하여 측정하였다. 결 과 : CBCT를 기준으로 노드1, 2, 3 cm의 체적을 비교하였을 때 4DCT의 MIP는 0.54~2.33, 5.16~8.06, 9.03~20.11 ml, MinIP는 0.00~1.48, 0.00~8.47, 1.42~24.85 ml, AVG는 0.00~1.17, 0.00~2.19, 0.04~3.35 ml의 차이를 보였다. 결 론 : 노드의 체적을 비교한 결과 CBCT 영상은 4DCT의 AVG 영상과 유사한 것으로 확인되었다.

  • PDF

지역적 거리전파를 이용한 자동 폐 정합 (Automatic Lung Registration using Local Distance Propagation)

  • 이정진;홍헬렌;신영길
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제32권1호
    • /
    • pp.41-49
    • /
    • 2005
  • 본 논문에서는 동일 환자에 대하여 시간차론 두고 촬영한 복부 CT 영상에서 환자의 움직임에 따른 두 영상 간 차이를 보정하기 위하여 지역적 거리전파를 이용한 자동 폐 정합 방법을 제안한다. 본 제안방법은 다음과 같은 세 단계로 구성된다 첫 번째, 일련의 두 볼륨데이타에서 폐 경계를 추출한 후, 폐를 포함하는 최적경계볼륨을 생성하여 초기정합을 수행한다 두 번째, 초기에 촬영한 볼륨데이타에서 지역적 거리전파를 이용하여 폐 경계로부터 3차원 거리맵을 생성한다. 세 번째, 선택적 거리 측정을 통해 두 경계간에 거리차이가 최소인 위치로 영상을 정합한다. 실험으로 3명의 환자 데이타에 대하여 영상정합을 하였고, 기존의 챔퍼매칭 정합 방법과 수행속도와 견고성 측면에서 비교 평가하였다. 본 제안방법은 지역적 거리전파를 사용하여 생성된 3차원 거리맵을 이용한 선택적 거리측정을 통하여 최적의 위치로 빠르고 견고하게 정합된다.

다시점 3차원 비디오 재생 시스템 설계 및 구현 (Design and Implementation of Multi-View 3D Video Player)

  • 허영수;박광훈
    • 방송공학회논문지
    • /
    • 제16권2호
    • /
    • pp.258-273
    • /
    • 2011
  • 본 논문에서는 기존 비디오 재생 시스템보다 고속으로 동작하는 다시점 3차원 비디오 재생 시스템을 설계하여 구현하였다. 대용량의 다시점 영상 데이터를 고속으로 처리하기 위해 구성 모듈들을 병렬화하여 다중코어 프로세서 환경에서 최적의 속도를 얻을 수 있는 구조를 제안하였다. 병목지점의 병행성을 활용하기 위하여 복호화, 영상합성, 렌더링 모듈을 파이프라인 구조로 설계하였다. 부하 균형을 위하여 복호화 모듈을 시점 단위로 분할하고, 영상합성 모듈을 합성영상을 기준으로 기하적으로 데이터 분할하였다. 실험결과로서, 다시점 영상이 올바르게 합성되어 무안경식 다시점 입체디스플레이 상에서 시청 시 입체감을 느낄 수 있었으며, 제안하는 응용프로그램의 처리구조는 다중코어 프로세서를 최대 활용하여 대용량의 다시점 영상데이터를 고속으로 처리할 수 있었다.

자동 광섬유 정렬 장치의 설계 및 제작에 관한 연구 (A Study on the Design and Development of Automatic Optical Fiber Aligner)

  • 김병희;엄철;최영석
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.241-249
    • /
    • 2002
  • Optical fiber is indispensable for optical communication systems that transmit large volumes of data at high speed, but super precision technology in sub-micron units is required for optical axis adjustment. We developed the automatic optical fiber by image processing and automatic loading system. we have developed 6-axis micro stage system for I/O optical fiber arrays, the initial automatic aligning system software for a input optical array by the image processing technique, fast I/O-synchronous aligning strategy, the automatic loading/unloading system and the automatic UV bonding mechanism. In order to adjust the alignment it used on PC based motion controller, a $10{\mu}m$ repeat-detailed drawing of automatic loading system is developed by a primary line up for high detailed drawing. Also, at this researches used the image processing system and algorithm instead of the existing a primary hand-line up and fiber input array and waveguide chip formed in line by automatic.

  • PDF

빠른 IHS 기법을 이용한 IKONOS 영상융합 (IKONOS Image Fusion Using a Fast Intensity-Hue-Saturation Fusion Technique)

  • 윤공현
    • 대한공간정보학회지
    • /
    • 제14권1호
    • /
    • pp.21-27
    • /
    • 2006
  • 영상융합의 많은 방법들 중에 IHS 기법은 많은 대용량의 자료를 빨리 융합할 수 있는 장점을 가지고 있다. IKONOS 영상에 대하여 IHS기법은 향상된 공간해상도의 결과를 보여주고 있으나 분광의 왜곡을 포함하고 있다. 즉, 융합된 다중파장대 영상과 원래 다중파장대영상의 비교시 분광정보의 왜곡이 나타난다. 이러한 문제를 해결하기 위해서 본 연구에서는 분광정보 조정을 통하여 빠른 처리 속도를 지니는 IHS기법을 제안하였다. 실험결과 제안된 방법은 고전적인 IHS 융합기법보다 속도와 영상 질의 측면에서 더 나은 결과를 보여주었다.

  • PDF