• Title/Summary/Keyword: Image volumes

Search Result 148, Processing Time 0.013 seconds

Comparison of the Quality of Various Polychromatic and Monochromatic Dual-Energy CT Images with or without a Metal Artifact Reduction Algorithm to Evaluate Total Knee Arthroplasty

  • Hye Jung Choo;Sun Joo Lee;Dong Wook Kim;Yoo Jin Lee;Jin Wook Baek;Ji-yeon Han;Young Jin Heo
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1341-1351
    • /
    • 2021
  • Objective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. Materials and Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. Results: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. Conclusion: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.

AMD Identification from OCT Volume Data using Deep Convolutional Neural Network (심층 컨볼루션 신경망을 이용한 OCT 볼륨 데이터로부터 AMD 진단)

  • Kwon, Oh-Heum;Jung, Yoo Jin;Song, Ha-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.8
    • /
    • pp.1291-1298
    • /
    • 2017
  • Optical coherence tomography (OCT) is the most common medical imaging device with the ability to image the retina in eyes at micrometer resolution and to visualize the pathological indicators of many retinal diseases such as Age-Related Macular Degeneration (AMD) and diabetic retinopathy. Accordingly, there have been research activities to analyze and process OCT images to identify those indicators and make medical decisions based on the findings. In this paper, we use a deep convolutional neural network for analysis of OCT volume data to distinguish AMD from normal patients. We propose a novel approach where images in each OCT volume are grouped together into sub-volumes and the network is trained by those sub-volumes instead of individual images. We conducted an experiment using public data set to evaluate the performance of the proposed approach. The experiment confirmed performance improvement of our approach over the traditional image-by-image training approach.

Fully Automatic Segmentation and Volumetry on Brain MRI of Coronal Section

  • Sung, Yun-Chang;Song, Chang-Jun;Noh, Seung-Moo;Park, Jong-Won
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.441-445
    • /
    • 2000
  • This study is to segment white matter, gray matter, and cerebrospinal fluid(CSF) on a brain MR image of coronal section and to calculate the volume of each. First, we segmented the whole region of a brain from a black colored background, a skull and a fat layer. Then, we calculated the partial volume of each component, which was present in scanning finite thickness, with the arithmetical analysis of gray value from the internal region of a brain showing the blurring effects on the basis of the MR image forming principle. Calculated partial volumes of white matter, gray matter and CSF were used to determine the threshold for the segmentation of each component on a brain MR image showing the blurring effects. Finally, the volumes of segmented white matter, gray matter, and CSF were calculated. The result of this study can be used as the objective diagnostic method to determine the degree of brain atrophy of patients who have neurodegenertive diseases such as Alzheimer’s disease and cerebral palsy.

  • PDF

Automatic Image Matching of Portal and Simulator Images Using courier Descriptors (후리에 표시자를 이용한 포탈영상과 시뮬레이터 영상의 자동결합)

  • 허수진
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.9-16
    • /
    • 1997
  • We develop an automatic imaging matching technique for combining portal image and simulator image for improvements in localization of treatment in radiation therapy. Fusion of images from two imaging modalities is treated as follows. We archive images thxough a frame-yabber. The simulator and portal images are edge detected and enhanced with interpolated adaptive histouam equalization and combined using geometrical parameters relating the coordinates of two image data sets which are calculated using Fourier descriptors. We don't use any kind of imaging markers for patient's convenience. clinical use of this image matching technique for treatment planning will result in improvements in localization of treatment volumes and critical structures. These improvements will allow greater sparing of normal tissues and more precise delivery of energy to the desired irradiation volume.

  • PDF

Region Segmentation and Volumetry of Brain MR Image represented as Blurred Gray Value by the Partial Volume Artifact (부분체적에 의해 번진 명암 값으로 표현된 뇌의 자기공명영상에 대한 영역분할 및 체적계산)

  • 성윤창;송창준;노승무;박종원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.7A
    • /
    • pp.1006-1016
    • /
    • 2000
  • This study is to segment white matter, gray matter, and cerebrospinal fluid(CSF) on a brain MR image and to calculate the volume of each. First, after removing the background on a brain MR image, we segmented the whole region of a brain from a skull and a fat layer. Then, we calculated the partial volume of each component, which was present in scanning finite thickness, with the arithmetical analysis of gray value from the internal region of a brain showing the blurring effects on the basis of the MR image forming principle. Calculated partial volumes of white matter, gray matter and CSF were used to determine the threshold for the segmentation of each component on a brain MR image showing the blurring effects. Finally, the volumes of segmented white matter, gray matter, and CSF were calculated. The result of this study can be used as the objective diagnostic method to determine the degree of brain atrophy of patients who have neurodegenerative diseases such as Alzheimer's disease and cerebral palsy.

  • PDF

Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom (호흡동조전산화단층촬영과 콘빔전산화단층촬영의 팬텀 영상 체적비교)

  • Kim, Seong-Eun;Won, Hui-Su;Hong, Joo-Wan;Chang, Nam-Jun;Jung, Woo-Hyun;Choi, Byeong-Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • Purpose : The aim of this study was to compare the differences between the volumes acquired with four-dimensional computed tomography (4DCT)images with a reconstruction image-filtering algorithm and cone-beam computed tomography (CBCT) images with dynamic phantom. Materials and Methods : The 4DCT images were obtained from the computerized imaging reference systems (CIRS) phantom using a computed tomography (CT) simulator. We analyzed the volumes for maximum intensity projection (MIP), minimum intensity projection (MinIP) and average intensity projection (AVG) of the images obtained with the 4DCT scanner against those acquired from CBCT images with CT ranger tools. Results : Difference in volume for node of 1, 2 and 3 cm between CBCT and 4DCT was 0.54~2.33, 5.16~8.06, 9.03~20.11 ml in MIP, respectively, 0.00~1.48, 0.00~8.47, 1.42~24.85 ml in MinIP, respectively and 0.00~1.17, 0.00~2.19, 0.04~3.35 ml in AVG, respectively. Conclusion : After a comparative analysis of the volumes for each nodal size, it was apparent that the CBCT images were similar to the AVG images acquired using 4DCT.

  • PDF

Automatic Lung Registration using Local Distance Propagation (지역적 거리전파를 이용한 자동 폐 정합)

  • Lee Jeongjin;Hong Helen;Shin Yeong Gil
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.1
    • /
    • pp.41-49
    • /
    • 2005
  • In this Paper, we Propose an automatic lung registration technique using local distance propagation for correcting the difference between two temporal images by a patient's movement in abdomen CT image obtained from the same patient to be taken at different time. The proposed method is composed of three steps. First, lung boundaries of two temporal volumes are extracted, and optimal bounding volumes including a lung are initially registered. Second, 3D distance map is generated from lung boundaries in the initially taken volume data by local distance propagation. Third, two images are registered where the distance between two surfaces is minimized by selective distance measure. In the experiment, we evaluate a speed and robustness using three patients' data by comparing chamfer-matching registration. Our proposed method shows that two volumes can be registered at optimal location rapidly. and robustly using selective distance measure on locally propagated 3D distance map.

Design and Implementation of Multi-View 3D Video Player (다시점 3차원 비디오 재생 시스템 설계 및 구현)

  • Heo, Young-Su;Park, Gwang-Hoon
    • Journal of Broadcast Engineering
    • /
    • v.16 no.2
    • /
    • pp.258-273
    • /
    • 2011
  • This paper designs and implements a multi-view 3D video player system which is operated faster than existing video player systems. The structure for obtaining the near optimum speed in a multi-processor environment by parallelizing the component modules is proposed to process large volumes of multi-view image data at high speed. In order to use the concurrency of bottleneck, we designed image decoding, synthesis and rendering modules in a pipeline structure. For load balancing, the decoder module is divided into the unit of viewpoint, and the image synthesis module is geometrically divided based on synthesized images. As a result of this experiment, multi-view images were correctly synthesized and the 3D sense could be felt when watching the images on the multi-view autostereoscopic display. The proposed application processing structure could be used to process large volumes of multi-view image data at high speed, using the multi-processors to their maximum capacity.

A Study on the Design and Development of Automatic Optical Fiber Aligner (자동 광섬유 정렬 장치의 설계 및 제작에 관한 연구)

  • Kim, Byung-Hee;Uhm, Chul;Choi, Young-Suk
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.241-249
    • /
    • 2002
  • Optical fiber is indispensable for optical communication systems that transmit large volumes of data at high speed, but super precision technology in sub-micron units is required for optical axis adjustment. We developed the automatic optical fiber by image processing and automatic loading system. we have developed 6-axis micro stage system for I/O optical fiber arrays, the initial automatic aligning system software for a input optical array by the image processing technique, fast I/O-synchronous aligning strategy, the automatic loading/unloading system and the automatic UV bonding mechanism. In order to adjust the alignment it used on PC based motion controller, a $10{\mu}m$ repeat-detailed drawing of automatic loading system is developed by a primary line up for high detailed drawing. Also, at this researches used the image processing system and algorithm instead of the existing a primary hand-line up and fiber input array and waveguide chip formed in line by automatic.

  • PDF

IKONOS Image Fusion Using a Fast Intensity-Hue-Saturation Fusion Technique (빠른 IHS 기법을 이용한 IKONOS 영상융합)

  • Yun, Kong-Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.14 no.1 s.35
    • /
    • pp.21-27
    • /
    • 2006
  • Among various image fusion methods, intensity-hue-saturation(IHS) technique is capable of quickly merging the massive volumes of data. For IKONOS imagery, IHS can yield satisfactory 'spatial' enhancement but may introduce 'spectral' distortion, appearing as a change in colors between compositions of resampled and fused multispectral bands. To solve this problem a fast IHS fusion technique with spectral adjustment is presented. The experimental results demonstrate that the proposed approach can provide better performance than the conventional IHS method, in both processing speed and image quality.

  • PDF