• 제목/요약/키워드: Image retention

검색결과 59건 처리시간 0.031초

ZnO nanostructures for e-paper and field emission display applications

  • Sun, X.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.993-994
    • /
    • 2008
  • Electrochromic (EC) devices are capable of reversibly changing their optical properties upon charge injection and extraction induced by the external voltage. The characteristics of the EC device, such as low power consumption, high coloration efficiency, and memory effects under open circuit status, make them suitable for use in a variety of applications including smart windows and electronic papers. Coloration due to reduction or oxidation of redox chromophores can be used for EC devices (e-paper), but the switching time is slow (second level). Recently, with increasing demand for the low cost, lightweight flat panel display with paper-like readability (electronic paper), an EC display technology based on dye-modified $TiO_2$ nanoparticle electrode was developed. A well known organic dye molecule, viologen, was adsorbed on the surface of a mesoporous $TiO_2$ nanoparticle film to form the EC electrode. On the other hand, ZnO is a wide bandgap II-VI semiconductor which has been applied in many fields such as UV lasers, field effect transistors and transparent conductors. The bandgap of the bulk ZnO is about 3.37 eV, which is close to that of the $TiO_2$ (3.4 eV). As a traditional transparent conductor, ZnO has excellent electron transport properties, even in ZnO nanoparticle films. In the past few years, one-dimension (1D) nanostructures of ZnO have attracted extensive research interest. In particular, 1D ZnO nanowires renders much better electron transportation capability by providing a direct conduction path for electron transport and greatly reducing the number of grain boundaries. These unique advantages make ZnO nanowires a promising matrix electrode for EC dye molecule loading. ZnO nanowires grow vertically from the substrate and form a dense array (Fig. 1). The ZnO nanowires show regular hexagonal cross section and the average diameter of the ZnO nanowires is about 100 nm. The cross-section image of the ZnO nanowires array (Fig. 1) indicates that the length of the ZnO nanowires is about $6\;{\mu}m$. From one on/off cycle of the ZnO EC cell (Fig. 2). We can see that, the switching time of a ZnO nanowire electrode EC cell with an active area of $1\;{\times}\;1\;cm^2$ is 170 ms and 142 ms for coloration and bleaching, respectively. The coloration and bleaching time is faster compared to the $TiO_2$ mesoporous EC devices with both coloration and bleaching time of about 250 ms for a device with an active area of $2.5\;cm^2$. With further optimization, it is possible that the response time can reach ten(s) of millisecond, i.e. capable of displaying video. Fig. 3 shows a prototype with two different transmittance states. It can be seen that good contrast was obtained. The retention was at least a few hours for these prototypes. Being an oxide, ZnO is oxidation resistant, i.e. it is more durable for field emission cathode. ZnO nanotetropods were also applied to realize the first prototype triode field emission device, making use of scattered surface-conduction electrons for field emission (Fig. 4). The device has a high efficiency (field emitted electron to total electron ratio) of about 60%. With this high efficiency, we were able to fabricate some prototype displays (Fig. 5 showing some alphanumerical symbols). ZnO tetrapods have four legs, which guarantees that there is one leg always pointing upward, even using screen printing method to fabricate the cathode.

  • PDF

연마방법에 따른 금속의 활택도에 관한 연구 - Atomic Force Microscope를 이용한 - (A STUDY ON SURFACE ROUGHNESS OF METALS ACCORDING TO FINISHING AND POLISHING PROCEDURES - AN ATOMIC FORCE MICROSCOPE ANALYSIS -)

  • 박원규;우이형;최부병;이성복
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.1-19
    • /
    • 2003
  • The surface of metals should be as smooth as possible for optimum comfort, oral hygiene, low plaque retention, and resistance to corrosion. In this study five specimens of each precious metal(type III gold alloy, ceramic gold alloy, and Ag-Pd alloy) were divided into five groups according to finishing and polishing procedures : group 1(sandblaster), group 2(group 1+stone), group 3(group 2+brown rubber), group 4(group 3+green rubber), and group 5(group 4+rouge). Six specimens of each non-precious metal(Co-Cr alloy, Ni-Cr alloy, and Co-Cr-Ti alloy) were divided into six groups: group 1(sandblaster), group 2(group 1+hard stone), group 3(group 2+electrolytic polisher), group 4(group 3+brown hard rubber point), group 5(group 4+green hard rubber point), and group 6(group 5+rouge). Considering factors affecting the rate of abrasion, the same dentist applied each finishing and polishing procedure. In addition, the surface roughness of enamel, resin, and porcelain was evaluated. The effect of finishing and polishing procedures on surface roughness of precious and non-precious metals, enamel, resin, and porcelain was evaluated by means of Atomic Force Microscope(AutoProbe CP. Park Scientific Instruments, U.S.A.) that can image the three dimensional surface profile and measure average surface roughness values of each sample at the same time. The obtained results were as follows : 1. According to finishing and polishing procedures, the surface roughness of type III gold alloy, ceramic gold alloy, and Ag-Pd alloy was decreased in the order of group 1, 2, 3, 4, and 5 (P<0.01). 2. According to finishing and polishing procedures. the surface roughness of Co-Cr alloy, Ni-Cr alloy, and Co-Cr-Ti alloy was decreased in the order of group 1, 2, 3, 4, 5, and 6 (p<0.01). 3. There was not statistically significant difference in the surface roughness among three metals of precious metals in group 1 but was significant difference in group 2, 3, 4, and 5 (P<0.05). 4. There was not statistically significant difference in the surface roughness among three metals of non-precious metals in all groups. 5. When the surface roughness of the smoothest surface of each metal, enamel. porcelain, and resin was compared, porcelain was the smoothest and the surface roughness was decreased in the order of Ni-Cr alloy. Co-Cr alloy. Co-Cr-Ti alloy, resin. Ag-Pd alloy, ceramic gold alloy type III gold alloy, and enamel (P<0.01). The results of this study indicate that the finishing and polishing procedures should be carried out in a logical, systematic sequence of steps and the harder non-precious metals may be less resistance to abrasion than are the softer precious metals.

ORAL REHABILITATION IN ECTODERMAL DYSPLASIA WITH OLIGODONTIA

  • 김령;최영철;이긍호
    • 대한소아치과학회지
    • /
    • 제26권4호
    • /
    • pp.636-643
    • /
    • 1999
  • 유전적인 외배엽 이형성증에 의해 무치증 혹은 부분적 무치증을 가진 환아들은 치조골 발육의 부족으로 나타난 감소된 수직고경으로 인해 어린 나이에서 노인과 같은 안모를 가지게 된다. 이에 어린이들은 또래의 어린이들과 잘 어울릴 수 없게 되고 소외감과 정서적 위축감을 느끼게 된다. 수직고경을 고려한 보철적 치료를 통해 적절한 기능과 심미적인 개선을 이룰 수 있도록 도와주는 것이 치과의사의 중요한 역할이라 하겠다. 이에 저자는 경희대학교 치과대학 부속치과병원 소아치과에 내원한 부분적 무치증을 동반한 외배엽 이형성증을 가진 환아에서 치과치료를 통한 심미적, 기능적 결함을 개전하면서 다음과 같은 결론을 얻었기에 보고하는 바이다. 1. 맹출 영구치 위에 클래스프를 위치시켜 의치유지력에 도움을 주었으며 상하악 피개의치의 장착으로 교합고경을 회복하여 저작, 발음, 심미적인 개선이 이루어졌다. 2. 피개의치의 이용으로 교합평면의 설정과 의치의 유지와 안정을 도모하였고, 맹출한 치아를 보존하고 남아있는 치조골의 폭과 높이를 유지할 수 있었다. 3. 치료를 통해 환아는 외모에 자신감을 가지고 치과환경에 익숙해져 긍정적인 태도를 가지게 되었다. 4. 주기적인 내원을 통한 영구치 상태와 성장, 발육동안의 의치의 관찰로 의치의 이장, 재제작이 요구된다.

  • PDF

Rabbit maxillary sinus augmentation model with simultaneous implant placement: differential responses to the graft materials

  • Kim, Young-Sung;Kim, Su-Hwan;Kim, Kyoung-Hwa;Jhin, Min-Ju;Kim, Won-Kyung;Lee, Young-Kyoo;Seol, Yang-Jo;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • 제42권6호
    • /
    • pp.204-211
    • /
    • 2012
  • Purpose: This study was performed to establish an experimental rabbit model for single-stage maxillary sinus augmentation with simultaneous implant placement. Methods: Twelve mature New Zealand white rabbits were used for the experiments. The rabbit maxillary sinuses were divided into 3 groups according to sinus augmentation materials: blood clot (BC), autogenous bone (AB), and bovine-derived hydroxyapatite (BHA). Small titanium implants were simultaneously placed in the animals during the sinus augmentation procedure. The rabbits were sacrificed 4 and 8 weeks after surgery and were observed histologically. Histomorphometric analyses using image analysis software were also performed to evaluate the parameters related to bone regeneration and implant-bone integration. Results: The BC group showed an evident collapse of the sinus membrane and limited new bone formation around the original sinus floor at 4 and 8 weeks. In the AB group, the sinus membrane was well retained above the implant apex, and new bone formation was significant at both examination periods. The BHA group also showed retention of the elevated sinus membrane above the screw apex and evident new bone formation at both points in time. The total area of the mineral component (TMA) in the area of interest and the bone-to-implant contact did not show any significant differences among all the groups. In the AB group, the TMA had significantly decreased from 4 to 8 weeks. Conclusions: Within the limits of this study, the rabbit sinus model showed satisfactory results in the comparison of different grafting conditions in single-stage sinus floor elevation with simultaneous implant placement. We found that the rabbit model was useful for maxillary sinus augmentation with simultaneous implant placement.

와벽 이개도가 레진 인레이의 시멘트 두께 및 접착 강도에 미치는 영향 (EFFECT OF CAVITY DIVERGENCY ON CEMENT THICKNESS AND BOND STRENGTH OF RESIN INLAY)

  • 차윤석;조용범;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.619-627
    • /
    • 1996
  • There are increasing use of composite resin in the posterior teeth and the new indirect inlay technique was introduced for compensating much troubles faced in direct technique. Many researchers insisted that overall properties of restorative materials were enhanced by an additional curing but this technique still has a problems about using cement material. Resin inlay obtains retention force from friction and another adhesion to tooth structure. A shape of cavity preparation was noted but studies about cement thickness and bond strength with cavity divergency are rare. The purpose of this study is to assess the effect of cavity divergency on cement thickness and bond strength of resin inlay. Cavities, which divergency was $6^{\circ}$, $16^{\circ}$, and $26^{\circ}$ in each group, were prepared and their divergency was verified by Adobe Photoshop program through the image capture with stereo microscope and FlexCam. Inlays were fixed into the cavities with a resin cement, Superbond and were handled under chemical (in 75% ethanol for 24 hrs.) and thermal stress (500 cycles from $5^{\circ}$ to $55^{\circ}C$). MXT 70 (x400) was used for measuring the cement thickness and bond strength was evaluated with a universal testing machine. Following results were obtained : 1. The cement thickness in Mean (S.D.) were; 35.58 (10.31)${\mu}m$ in $6^{\circ}$ group, 35.97 (10.49)${\mu}m$ in $16^{\circ}$ group, and 41.43 (9.33)${\mu}m$ in $26^{\circ}$ group. But there was no significant difference between groups. 2. The bond strength in Mean (S.D.) were ; 33.18 (5.53)kg in $6^{\circ}$ group, 23.47 (13.40)kg in $16^{\circ}$ group, and 19.75 (10.48)kg in $26^{\circ}$ group. $6^{\circ}$ group showed significantly higher value compared to $16^{\circ}$ and $26^{\circ}$ groups (p<0.05). Although the results of this study indicate $6^{\circ}$ divergency will be good for resin inlay, cavity preparation with this type will have lots of difficulties in manufacturing, try-in, and cementation procedures, such as deformation. So it is concluded that $16^{\circ}$ divergent cavity preparation is recommended in resin inlay technique.

  • PDF

올리브 오일의 에스터 교환반응 생성물의 TLC를 이용한 조성비 분석 및 화장품에의 응용가능성 평가 (Composition Ratio Analysis of Transesterification Products of Olive Oil by Using Thin Layer Chromatography and Their Applicability to Cosmetics)

  • 박소현;신혁수;김아랑;정효진;현송화;홍인기;이대봉;박수남
    • 공업화학
    • /
    • 제29권3호
    • /
    • pp.342-349
    • /
    • 2018
  • 본 연구에서는 올리브 오일의 에스터 교환반응으로 생성된 복합소재(olive oil esters)의 화장품 응용을 위해 물리화학적 성질, 유화력, 보습력 및 세포독성을 평가하였다. 실험에는 반응시간이 짧은 olive oil esters S와 반응시간이 긴 olive oil esters L을 사용하였다. 먼저 TLC 이미지 분석으로 조성비를 확인한 결과, olive oil esters S의 조성은 mono-, di-, tri-glyceride가 5.2, 24.1, 46.4%이었고, fatty acid ethyl ester는 21.9%이었다. Olive oil esters L은 mono-, di-, tri-glyceride가 4.1, 24.7, 40.6%이었고, fatty acid ethyl ester는 28.8%이었다. 올리브 오일 에스터를 화장품에 사용하기 위한 기준 및 시험방법 설정을 위해 요오드가, 산가, 검화가, 불검화물, 굴절률, 비중 및 순도시험을 수행하였고 표준화시켰다. 또한 올리브 오일 에스터의 유화력 평가로서, 계면활성제 없이 O/W 에멀전을 제조하여 유화 입자를 확인하였다. 올리브 오일 에스터를 사람 피부에 도포 5일 후, 피부 수분 보유량은 초기보다 13.1% 개선되었다. 피부 세포에 대한 독성을 평가한 결과, 올리브 오일 에스터는 $0.2-200{\mu}g/mL$에서 세포 생존율 90% 이상을 나타내 안전성이 확인되었다. 결과적으로 올리브 오일 에스터는 화장품 산업에서 천연/무독성 원료로서 응용가능성이 있음을 시사하였다.

하악 임플란트 오버덴쳐에서 어태치먼트 종류에 따른 응력분포 (The Influence of Attachment Type on the Distribution of Occlusal Force in Implant Supported Overdentures)

  • 성채련;조인호
    • 구강회복응용과학지
    • /
    • 제25권4호
    • /
    • pp.375-390
    • /
    • 2009
  • 하악 완전 무치악 환자에서 이공 사이에 2개의 임플란트를 식립한 후 4종류의 어태치먼트를 사용한 하악 오버덴쳐를 제작하여 유한요소 모델을 만들고 여기에 3가지 하중 조건을 가하여 유한요소 해석 프로그램인 ANSYS 10.0을 이용하여 어태치먼트 종류에 따른 임플란트 주위골과 보철물 및 임플란트와 골 사이 계면에 발생하는 최대 응력의 크기와 응력 분포양상을 분석하였다. 하악골체의 전체적인 골격구조에서 치아 부분은 오버덴쳐로 모델을 형성하였고 오버덴쳐와 하악골 사이에 2mm 두께의 점막을 삽입하였다. 임플란트 오버덴쳐의 유한요소 모델은 ball and socket, Locator, magnet, bar의 각각 4가지 형태를 제작하였다. 고정체의 식립 위치는 양측 이공 전방이고, 경계 조건 중 고정점은 하악각 부위와 모형의 최후방 절점들을 고정점으로 설정하였다. 하중조건은 오버덴쳐의 좌측 제 2소구치에서 제 2대구치 편측 부위에 170N의 하중을, 좌 우측 제 2소구치에서 제 2대구치 양측 부위에 170N의 하중을, $90^{\circ}$수직 방향, $45^{\circ}$경사, 그리고 $0^{\circ}$ 수평 방향으로 가하였다. 결과 분석시 모든 하중방향에서 응력의 크기는 bar에서 임플란트나 오버덴쳐에서 가장 크게 나타났으며, 계면에서의 응력은 모든 어태치먼트에서 비슷한 응력분포가 나타났다. Ball and socket, Locator, magnet에서는 유의성을 보이지 않았다. 응력의 분포도에서는 4종류의 어태치먼트 모두 임플란트 치경부에서 응력이 집중된 양상을 보였으며 bar타입에서는 bar의 중앙에 응력이 크게나타났다. 이상의 결과로 볼 때 어태치먼트의 종류에 따라 응력분포의 차이가 있었음을 확인할 수 있었다. 어태치먼트의 선정 시 응력집중을 완화시킬 수 있는 바람직한 설계와 선택이 필요하리라 사료된다.

두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study) (Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study)

  • 이지은;허성주;곽재영;김성균;한종현
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.169-174
    • /
    • 2008
  • 목적: 치과 임플랜트 주위의 변연골 변화는 임플랜트의 기능적인 유지 뿐만 아니라 심미적 성공을 위해서도 중요하다. 변연골의 유지를 위한 임플랜트 디자인이 연구되고 있다. 이번 예비 연구는 두 종류의 external hex implant 시스템에서 임플랜트의 상부 미세 나사산이 변연골 변화량에 미치는 영향을 평가하고자 한다. 재료 및 방법: 총 24명의 환자를 대상으로 $Br{{\aa}}nemark$ 임플랜트 식립군 (1군, 거친 표면 임플랜트, 20개)과 원플란트 임플랜트 식립군 (2군, 미세나사산을 가진 거친 표면 임플랜트, 20개)으로 분류하였다. 기준 시점 (임플랜트 부하)과 부하를 가한 1년 뒤 임상적, 방사선학적 검사를 시행하였다. UTHSCSA Image Tool을 이용하여 임플랜트-보철 경계부로부터 변연골 높이 변화량으로 계측하였다. 계측치는 SAS 프로그램을 이용하여 three-level ANCOVA로 통계처리 하였다. 결과: 기준 시점과 비교하여 1년 기능 후, 두 그룹 간의 변연골 소실 변화량에 있어서 통계학적으로 유의한 차이가 있었다 (P<0.05). 1군의 평균 변연골 높이 변화량은 $0.83{\pm}0.31mm$, 2군에 있어서는 $0.44{\pm}0.36mm$ 이었다. 미세나사산을 가진 거친 표면 임플랜트가 미세나 사산을 가지지 않은 거친 표면 임플랜트 보다 더 적은 변연골 소실 변화량을 보였다. 결론: 미세나사산을 가진 거친 표면 임플랜트가 기능적 부하 후 변연골 높이를 유지하는데 있어 더 유리한 디자인으로 보인다.

이차원 고객충성도 세그먼트 기반의 고객이탈예측 방법론 (A Methodology of Customer Churn Prediction based on Two-Dimensional Loyalty Segmentation)

  • 김형수;홍승우
    • 지능정보연구
    • /
    • 제26권4호
    • /
    • pp.111-126
    • /
    • 2020
  • CRM의 하위 연구 분야로 진행되었던 고객이탈예측은 최근 비즈니스 머신러닝 기술의 발전으로 인해 빅데이터 기반의 퍼포먼스 마케팅 주제로 더욱 그 중요도가 높아지고 있다. 그러나, 기존의 관련 연구는 예측 모형 자체의 성능을 개선시키는 것이 주요 목적이었으며, 전체적인 고객이탈예측 프로세스를 개선하고자 하는 연구는 상대적으로 부족했다. 본 연구는 성공적인 고객이탈관리가 모형 자체의 성능보다는 전체 프로세스의 개선을 통해 더 잘 이루어질 수 있다는 가정하에, 이차원 고객충성도 세그먼트 기반의 고객이탈예측 프로세스 (CCP/2DL: Customer Churn Prediction based on Two-Dimensional Loyalty segmentation)를 제안한다. CCP/2DL은 양방향, 즉 양적 및 질적 로열티 기반의 고객세분화를 시행하고, 고객세그먼트들을 이탈패턴에 따라 2차 그룹핑을 실시한 뒤, 이탈패턴 그룹별 이질적인 이탈예측 모형을 독립적으로 적용하는 일련의 이탈예측 프로세스이다. 제안한 이탈예측 프로세스의 상대적 우수성을 평가하기 위해 기존의 범용이탈예측 프로세스와 클러스터링 기반 이탈예측 프로세스와의 성능 비교를 수행하였다. 글로벌 NGO 단체인 A사의 협력으로 후원자 데이터를 활용한 분석과 검증을 수행했으며, 제안한 CCP/2DL의 성능이 다른 이탈예측 방법론보다 우수한 성능을 보이는 것으로 나타났다. 이러한 이탈예측 프로세스는 이탈예측에도 효과적일 뿐만 아니라, 다양한 고객통찰력을 확보하고, 관련된 다른 퍼포먼스 마케팅 활동을 수행할 수 있는 전략적 기반이 될 수 있다는 점에서 연구의 의의를 찾을 수 있다.