• Title/Summary/Keyword: Image modality

Search Result 165, Processing Time 0.048 seconds

MR Arthrography of the Labral-Capsular-Ligamentous Complex: Normal Variations and Pitfalls (관절와순낭인대(Labral-Capsular-Ligamentous) 복합체의 자기공명관절 조영술 : 정상변이 및 진단시 주의점)

  • Han Sung Ho;Yang Bo Kyu;Kim Chi Hong;Ahn Tae Won;Chu Wu Jun
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 1997.05a
    • /
    • pp.164-166
    • /
    • 1997
  • MR arthrography is a useful modality for evaluating the labrocapsular ligamentous complex(LOLC) of the shoulder. This study was performed to describe normal anatomic variations and pitfalis in image interpretation related to evaluation of the LOLC. MR Arthrogram of 56 shoulders in 41 asymptomatic young, active volunteers were prospectively reviewed to evaluate the labral shapes. capsular insertions and images which may mimic the lesions of glenohumoral instability. The anterior and posterior parts of the labra. respectively. varied in shape: triangular$(72\%,\; 36\%)$. round $(13\%,\; 35\%)$. cleaved$(8\%,\; 1\%)$. notched$(2\%,\; 0\%)$. flat$(5\%,\; 24\%)$ and absent$(0\%,\; 4\%)$. The anterior and posterior capsular insertions. respectively. varied in sites: Mosely and Oevergaard type I$(82\%,\;62\%)$, type II$(13\%,\; 3\%)$ and type III $(5\%,\; 2\%)$. A number of pitfalls in image interpretation were discovered. Articular cartilage undercutting the labrum$(29\%)$ and middle glenohumoral ligament in proximity to anterior labrum $(5\%)$ simulated a labral tear. Joint fluid interposed in the central. superior portion of the sublabral sulci$(25\%)$ simulated a SLAP lesion. Synovial fold$(38\%)$ in axillary pouch resembled a loose body. Knowledge of normal variations and pitfalls in MR arthrogram image interpretation of labral capsular - ligamentous complex will help the orthopedist to accurately detect debilitating derangements associated with the glenohumeral instability.

  • PDF

Image Reconstruction using Modified Iterative Landweber Method in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 수정된 반복 Landweber 방법을 이용한 영상 복원)

  • Kim, Bong-Seok;Kim, Ji-Hoon;Kim, Sin;Kim, Kyung-Youn
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.4
    • /
    • pp.36-44
    • /
    • 2012
  • Electrical impedance tomography is a relatively new imaging modality in which the internal conductivity (or resistivity) distribution of a object is reconstructed based on the injected currents and measured voltages through the electrodes placed on the surface of the object. In this paper, it is assumed that the relationship between the resistivity distribution and the resistance of electrodes is linear. From this linear relation, the weighting matrix can be obtained and modified iterative Landweber method is applied to estimate the internal resistivity distribution. Additionally, to accelerate the convergence rate and improve the spatial resolution of the reconstructed image, optimal step lengths for the iterative Landweber method are computed from the objective function in the least-square sense. The numerical experiments have been performed to illustrate the superior reconstruction performance of the proposed scheme.

Image Registration for PET/CT and CT Images with Particle Swarm Optimization (Particle Swarm Optimization을 이용한 PET/CT와 CT영상의 정합)

  • Lee, Hak-Jae;Kim, Yong-Kwon;Lee, Ki-Sung;Moon, Guk-Hyun;Joo, Sung-Kwan;Kim, Kyeong-Min;Cheon, Gi-Jeong;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.195-203
    • /
    • 2009
  • Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  • PDF

Improved Anatomical Landmark Detection Using Attention Modules and Geometric Data Augmentation in X-ray Images (어텐션 모듈과 기하학적 데이터 증강을 통한 X-ray 영상 내 해부학적 랜드마크 검출 성능 향상)

  • Lee, Hyo-Jeong;Ma, Se-Rie;Choi, Jang-Hwan
    • Journal of the Korea Computer Graphics Society
    • /
    • v.28 no.3
    • /
    • pp.55-65
    • /
    • 2022
  • Recently, deep learning-based automated systems for identifying and detecting landmarks have been proposed. In order to train such a deep learning-based model without overfitting, a large amount of image and labeling data is required. Conventionally, an experienced reader manually identifies and labels landmarks in a patient's image. However, such measurement is not only expensive, but also has poor reproducibility, so the need for an automated labeling method has been raised. In addition, in the X-ray image, since various human tissues on the path through which the photons pass are displayed, it is difficult to identify the landmark compared to a general natural image or a 3D image modality image. In this study, we propose a geometric data augmentation technique that enables the generation of a large amount of labeling data in X-ray images. In addition, the optimal attention mechanism for landmark detection was presented through the implementation and application of various attention techniques to improve the detection performance of 16 major landmarks in the skull. Finally, among the major cranial landmarks, markers that ensure stable detection are derived, and these markers are expected to have high clinical application potential.

Portable Low-Cost MRI System Based on Permanent Magnets/Magnet Arrays

  • Huang, Shaoying;Ren, Zhi Hua;Obruchkov, Sergei;Gong, JIa;Dykstra, Robin;Yu, Wenwei
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.179-201
    • /
    • 2019
  • Portable low-cost magnetic resonance imaging (MRI) systems have the potential to enable "point-of-care" and timely MRI diagnosis, and to make this imaging modality available to routine scans and to people in underdeveloped countries and areas. With simplicity, no maintenance, no power consumption, and low cost, permanent magnets/magnet arrays/magnet assemblies are attractive to be used as a source of static magnetic field to realize the portability and to lower the cost for an MRI scanner. However, when taking the canonical Fourier imaging approach and using linear gradient fields, homogeneous fields are required in a scanner, resulting in the facts that either a bulky magnet/magnet array is needed, or the imaging volume is too small to image an organ if the magnet/magnet array is scaled down to a portable size. Recently, with the progress on image reconstruction based on non-linear gradient field, static field patterns without spatial linearity can be used as spatial encoding magnetic fields (SEMs) to encode MRI signals for imaging. As a result, the requirements for the homogeneity of the static field can be relaxed, which allows permanent magnets/magnet arrays with reduced sizes, reduced weight to image a bigger volume covering organs such as a head. It offers opportunities of constructing a truly portable low-cost MRI scanner. For this exciting potential application, permanent magnets/magnet arrays have attracted increased attention recently. A magnet/magnet array is strongly associated with the imaging volume of an MRI scanner, image reconstruction methods, and RF excitation and RF coils, etc. through field patterns and field homogeneity. This paper offers a review of permanent magnets and magnet arrays of different kinds, especially those that can be used for spatial encoding towards the development of a portable and low-cost MRI system. It is aimed to familiarize the readers with relevant knowledge, literature, and the latest updates of the development on permanent magnets and magnet arrays for MRI. Perspectives on and challenges of using a permanent magnet/magnet array to supply a patterned static magnetic field, which does not have spatial linearity nor high field homogeneity, for image reconstruction in a portable setup are discussed.

Definition of Tumor Volume Based on 18F-Fludeoxyglucose Positron Emission Tomography in Radiation Therapy for Liver Metastases: An Relational Analysis Study between Image Parameters and Image Segmentation Methods (간 전이 암 환자의 18F-FDG PET 기반 종양 영역 정의: 영상 인자와 자동 영상 분할 기법 간의 관계분석)

  • Kim, Heejin;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Ji, Young Hoon;Yi, Chul-Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.99-107
    • /
    • 2013
  • The surgical resection was occurred mainly in liver metastasis before the development of radiation therapy techniques. Recently, Radiation therapy is increased gradually due to the development of radiation dose delivery techniques. 18F-FDG PET image showed better sensitivity and specificity in liver metastasis detection. This image modality is important in the radiation treatment with planning CT for tumor delineation. In this study, we applied automatic image segmentation methods on PET image of liver metastasis and examined the impact of image factors on these methods. We selected the patients who were received the radiation therapy and 18F-FDG PET/CT in Korea Cancer Center Hospital from 2009 to 2012. Then, three kinds of image segmentation methods had been applied; The relative threshold method, the Gradient method and the region growing method. Based on these results, we performed statistical analysis in two directions. 1. comparison of GTV and image segmentation results. 2. performance of regression analysis for relation between image factor affecting image segmentation techniques. The mean volume of GTV was $60.9{\pm}65.9$ cc and the $GTV_{40%}$ was $22.43{\pm}35.27$ cc, and the $GTV_{50%}$ was $10.11{\pm}17.92$ cc, the $GTV_{RG}$ was $32.89{\pm}36.8$4 cc, the $GTV_{GD}$ was $30.34{\pm}35.77$ cc, respectively. The most similar segmentation method with the GTV result was the region growing method. For the quantitative analysis of the image factors which influenced on the region growing method, we used the standardized coefficient ${\beta}$, factors affecting the region growing method show GTV, $TumorSUV_{MAX/MIN}$, $SUV_{max}$, TBR in order. The result of the region growing (automatic segmentation) method showed the most similar result with the CT based GTV and the region growing method was affected by image factors. If we define the tumor volume by the auto image segmentation method which reflect the PET image parameters, more accurate and consistent tumor contouring can be done. And we can irradiate the optimized radiation dose to the cancer, ultimately.

Melanoma Classification Algorithm using Gray-level Conversion Matrix Feature and Support Vector Machine (회색도 변환 행렬 특징과 SVM을 이용한 흑색종 분류 알고리즘)

  • Koo, Jung Mo;Na, Sung Dae;Cho, Jin-Ho;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.2
    • /
    • pp.130-137
    • /
    • 2018
  • Recently, human life is getting longer due to change of living environment and development of medical technology, and silver medical technology has been in the limelight. Geriatric skin disease is difficult to detect early, and when it is missed, it becomes a malignant disease and is difficult to treatment. Melanoma is one of the most common diseases of geriatric skin disease and initially has a similar modality with the nevus. In order to overcome this problem, we attempted to perform a feature analysis in order to attempt automatic detection of melanoma-like lesions. In this paper, one is first order analysis using information of pixels in radiomic feature. The other is a gray-level co-occurrence matrix and a gray level run length matrix, which are feature extraction methods for converting image information into a matrix. The features were extracted through these analyses. And classification is implemented by SVM.

CT Guided Cervical Transforaminal Steroid Injection: 2 Months Follow-up (CT 유도하 경추부위 경추간공 경막외 스테로이드주입술: 2개월 경과관찰)

  • Kim, Hoondo;Lee, Sang Ho;Kim, Myung-Ho
    • The Korean Journal of Pain
    • /
    • v.19 no.1
    • /
    • pp.51-55
    • /
    • 2006
  • Background: A cervical transforaminal steroid injection is an effective therapeutic modality for radiculopathy of a herniated cervical disc or a cervical foraminal stenosis. However, there is some debate regarding the safety of the transforaminal approach under C-arm guidance compared with the posterior interlaminar approach. We report a new technique for cervical transforaminal steroid injection guided by MDCT. Methods: Patients presenting with radiating pain on their shoulder or arm were diagnosed using CT or MRI of a cervical herniated disc or a foraminal stenosis. Each patient whose symptoms were compatible with the image scan was enrolled in this study. They received a cervical transforaminal steroid injection under CT guidance, and the effectiveness and complications of this technique were evaluated over a 2-month period. Results: According to the CT scan, none of the participants had an internal jugular vein or a carotid artery invasion during the procedure. No vertebral artery injection was noted, and no patient developed a hematoma after the injection. The VAS score had improved significantly by 2, 4 and 8 weeks after the injection. Conclusions: While a conventional C-arm guided cervical transforaminal steroid injection does not appear to differentiate between the major vessels and structures in images, a CT guided approach is a more useful and safer technique for the precise placement of a needle.

Performance Analysis of the Inversion Schemes in the Spotlight-mode SAR(Synthetic Aperture Radar) (Spotlight-mode SAR(Synthetic Aperture Radar)에서의 Inversion 기법 성능 분석)

  • 최정희
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.1
    • /
    • pp.130-138
    • /
    • 2003
  • The classical image reconstruction for stripmap-mode Synthetic Aperture Radar is the Range-Doppler algorithm. When the spotlight-mode SAR system was envisioned, Range-Doppler algorithm turned out to fail rapidly in this SAR imaging modality. Thus, what is referred to as Polar format algorithm, which is based on the Plane wave approximation, was introduced for imaging from spotlight-mode SAR raw- data. In this paper, we have studied for the raw data processing schemes in the spotlight-mode Synthetic Aperture Radar. We apply the Wavefront Reconstruction scheme that does not utilize the approximation in spotlight-mode SAR imaging modelity, and compare the performance of target imaging with the Polar format inversion scheme.

F-18 FDG PET/Cl Findings of Subcutaneous Panniculitis - like T- Cell lymphoma: A Case Report (피하 지방층염양 T-세포 림프종의 F-18 FDG PET/CT 소견)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Bae, Yeung-Kyung;Choi, Joon-Hyuk;Hyun, Myung-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.3
    • /
    • pp.240-244
    • /
    • 2009
  • F-18 FDG PET is a metabolic imaging modality that is efficacious in staging and assessment of treatment response for variety of lymphomas. We report usefulness of F-18 FOG PET/Cl in evaluating severity of the disease and response to therapy in a patient with subcutaneous panniculitis- like T-cell lymphoma (SPTCL). Here we describe a case of SPTCL in 24-year-old man who had wide spread firm and tender nodular lesions with increased F-18 FOG uptake. After chemotherapy follow up F-18 FDG PET/CT image shows disseminated malignancy and then the patient died with hemophagocytic syndrome. This report suggests that F-18 FDG PET/CT may be useful in determining disease activity at the time of initial diagnosis, after treatment, and evaluating a suspected outcome of SPTCL.