Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.

Usefulness of inverter type REX-650 R/F X-ray equipments (REX-650 RF 인버터장치의 성능평가)

  • Kim, Jung-Min;Oh, Jung-Hwan
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.31-37
    • /
    • 2003
  • The conclusions after appraisal usefulness of korean 30 kHz inverter type X-ray equipments which are currently used in the clinics are like those followings. 1. The specific characters of mA, kVp, msec in the radiography keep very good accuracy and showed good waveform also under KS regulations. 2. The output of the X-ray equipment is showed 1.7 times higher than single-phase. 3. mA, kVp of the fluoroscopy and Sopt film exposure mA, kVp showed appropriated results under the regulations. 4. As we consider the conversion factor of image intensifier tube used for two years, it showed pretty high results, 310 at 75 kV, and knew that the conversion factor which followed by increasing kVp increased its computations like Kim's experimentation. Those X-ray equipment showed excellent results in the appraisal while those were operating so we think that those X-ray equipments will be substitute for expensive foreign equipment in korean domestic medical equipment in the future.

  • PDF

Change of Radiologic Index of Foot according to Radiation Projection Angle: A Study Using Phantom Foot (방사선 투과 각도에 따른 족부 방사선 지표의 변화: Phantom Foot을 이용한 연구)

  • Kim, Eo Jin;Seo, Sang Gyo;Lee, Dong Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.4
    • /
    • pp.165-170
    • /
    • 2015
  • Purpose: The purpose of this study is to analyze the measurement differences of simple radiographs according to radiation projection angle using a phantom and to propose methods for objective analysis of simple radiographs. Materials and Methods: We took simple radiographs with different projection angles using a C-arm image intensifier and measured five parameters of the foot on the simple radiographic images. Five parameters include lateral tibiocalcaneal angle, lateral talocalcaneal angle, naviculocuboid overlap, lateral talo-first metatarsal angle, and lateral calcaneo-first metatarsal angle. Intraobserver and interobserver reliability were verified, and then intraclass correlations of parameters were analyzed. Results: Radiographic parameters of the foot showed high intraobserver and interobserver reliability. Lateral tibiocalcaneal angle has a strong negative linear relationship with rotation and a moderate negative linear relationship with tilt. Lateral talocalcaneal angle has a moderate positive linear relationship with rotation and a strong positive linear relationship with tilt. Naviculocuboid overlap has a strong positive linear relationship with rotation and a moderate positive linear relationship with tilt. Lateral talo-first metatarsal angle does not have a linear relationship with rotation and a moderate negative linear relationship with tilt. Lateral calcaneo-first metatarsal angle has a moderate positive linear relationship with rotation and tilt. Conclusion: More precise evaluation of the foot with a simple radiograph can be performed by understanding the changes of radiographic parameters according to radiation projection angle.

Dose Reduction According to Geometric Parameters of Digital Cerebral Angiography (두개부 혈관 조영검사 시 기하학적 특성에 따른 선량 감소 방안)

  • Park, Chan Woo;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.399-406
    • /
    • 2019
  • This study aims to find geometric parameters that the radiologist can change from time to time to reduce dose in angiography examinations. Depending on the geometric characteristics, the values calculated by effective dose were compared, while filming in fluoroscopy mode and Digital subtraction angiography, respectively. The study found that the lower the dose was in FPS mode, the lower the dose was reduced to 30-40%. Doses according to the X-ray angle were measured highest in AP View and lower as the angle went in the head direction. The greater the FOV, the higher the dose was 1.2-1.6 times, and the closer the distance between the X-ray tube and the table, the greater the dose was about 10%. Source-image intensifier distance (SID) get longer to 100 mm, dose of each fluoroscopy and Digital subtraction angiography increase up to 25-30%. In conclusion, various geometric characteristics in angiography examinations are parameters that can be applied by radiographers as frequently as possible, and appropriate geometric properties can be considered and applied in various situations, resulting in appropriate dose reduction.

The Correlation between Caudal Epidurogram and Low Back Pain

  • Jo, Dae-Hyun;Jang, Sul
    • The Korean Journal of Pain
    • /
    • v.25 no.1
    • /
    • pp.22-27
    • /
    • 2012
  • Background: The common causes of lower back pain with or without leg pain includes disk disease and spinal stenosis. A definitive diagnosis is usually made by means of magnetic resonance imaging (MRI), but treatment is often difficult because the MRI findings are not consistent with the symptoms of the patient in many cases. The objective of this study was to observe the correlation between the patterns of epidurography performed in patients having lower back pain with or without leg pain and the position or severity of the pain as subjectively described by the patients. Methods: The subjects of this study were 69 outpatients with lower back pain with or without leg pain who visited our clinic and complained of predominant pain on one side. We performed caudal epidural block using an image intensifier. A mixture of the therapeutic drug and the contrast agent (10 ml) was injected to observe the contrast flow pattern. The patients who complained of predominant pain on one side were divided into the left side group and the right side group. A judgment of inconsistency was made if the contrast agent flowed to the side of the pain, while a judgment of consistency was made if the contrast agent flowed to the opposite side of the pain. The degree of the drug distribution was evaluated by counting the number of cells to which the contrast agent's flowed for evaluating the correlation between the contrasted cell and the severity of pain (one group ${\leq}$ VAS 7, the other group ${\geq}$ VAS 8) the degree of the contrast agent's contrast was evaluated by dividing and counting an image into 15 cells (the left, right, and middle sections at each level of L4, L5, S1, S2, and S3). Results: Thirty out of the 69 patients who had laterality in pain, that is, those who complained of predominant pain on one side, showed that the laterality of the pain and the contrast agent flow was consistent, while 39 patients showed that the laterality was inconsistent (P: 0.137). The evaluation of the correlation between the pain and the contrast agent flow showed that the mean number of contrasted cells was $9.0{\pm}2.2$ for the 46 patients in the group with a VAS of 7 or lower and $6.5{\pm}2.0$ for the 23 patients in the group with a VAS of 8 or higher, indicating that the former group showed a significantly greater number of contrasted cells (P < 0.001). Conclusions: This study, conducted with patients having lower back pain with or without leg pain, showed that the contrast flow pattern of caudal epidurography had a significant correlation with the severity of the pain but not with the laterality of the pain.

Open Reduction of Acromioclavicular Joint for the Acromioclavicular Joint Dislocations (견봉 쇄골 관절 탈구에 대한 견봉 쇄골 관절의 관혈적 정복술)

  • Song, Hyun-Seok;Choi, Nam-Yong;Han, Suk-Ku;Nah, Ki-Ho;Nam, Won-Sik;Yang, Hyuk-Jae;Park, Sung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.189-195
    • /
    • 2006
  • Purpose: To analyze the result of the accurate open reduction of acromioclavicular (AC) joint and pin fixation, coracoclavicular (CC) screw fixation without CC ligament repair for AC joint injuries. Materials and Methods: Between January 2000 and December 2003, seventeen cases with at least one year follow-up among twenty-one cases underwent operation for AC-CC ligament injuries. A transverse incision approximately 5 cm in length was made over the clavicle, and the AC joint was reduced accurately. Under the image intensifier, a cannulated screw and washer were inserted for the CC ligament. Two Steinman pins were inserted for the AC joint and the AC ligament was repaired with nonabsorbable suture. Gentle passive range of motion was begun postoperative 2 weeks. The pins were removed at $6{\sim}8$ weeks and the screw was removed at $10{\sim}12$ weeks. The results were evaluated by a distance between AC and CC joints on plain films and ASES score at last follow-up. Results: At the last follow-up, there was no limitation of motion and average ASES score was 96($86{\sim}100$ points). There was no failure showing over 5 mm difference of distance compared to opposite side on the plain films. Seven cases had the skin damages and local infection due to pin migration and three cases showed the loosening of CC screw. Conclusion: We could have satisfactory results by accurate reduction of AC joint and simple pins and screw fixation for AC-CC ligament injuries.

Treatment of the Tibia Shaft Fractures with Ender Nails (Ender Nail을 이용한 경골간부 골절의 치료)

  • Kim, In-Ki;Lee, Dong-Chul;Seo, Jae-Sung;Ahn, Myun-Whan;Kim, Se-Dong;Ahn, Jong-Chul
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.1
    • /
    • pp.130-136
    • /
    • 1992
  • Fractures of the tibial shaft are the most common among the long bone fractures, and have much difficulty in treatment due to their enumerous complications. Thirty patients with fractures of the tibial shaft were treated with Ender nails under the image intensifier at the Department of Orthopedic Surgery, Yeungnam University Hospital from December 1986 to November 1991. The following results were observed. 1. The average age was 37.3 years and the number of male was three times of the female. The most common cause was traffic accident. 2. Twenty cases out of thirty one were closed fractrure and the remaining 11 were open. The comminuted and segmental fractures were 18(57.7%) in number and the most common fracture site was the middle one third(53%). 3. Average interval from injury to operation was 7.6 days and 19 cases showed associated injuries. 4. The mean duration of the bone union was 18.9 weeks and 2 cases showed the delayed union. 5. Twelve complications were noted such as shortening, varus deformity, delayed union, ankle motion limitation, nail irritation, and soft tissue infection.

  • PDF

The Results of Treatment of Lateral Meniscus Tear in Tibial Plateau Fracture (경골과 골절과 동반된 외측 반월상 연골 파열의 치료 결과)

  • Kim, Jung-Man;Kwon, Yong-Jin;Choi, Kwang-Chun;Choi, Seong-Pil;Yoo, Ju-Seok
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.2
    • /
    • pp.155-160
    • /
    • 2006
  • Purpose: To evaluate the results of meniscal repair and partial meniscectomy of lateral meniscus injury associated with tibial plateau fracture. Materials and Methods: Between February 1993 and August 2004, 24 cases (23 patients) of lateral meniscus tear with tibial plateau fracture were evaluated retrospectively. The most frequent type of tear was the longitudinal tear of the meniscocapsular junction (14 cases, 66.7%). All fractures were reduced under the control of arthroscopic and image intensifier. Arthroscopic repair of the longitudinal tear of the lateral meniscus or arthroscopic partial meniscectomy was performed. The final results were evaluated with the Ikeuchi criteria and Lysholm score. Results: At the final follow-up, the outcome was excellent in 12 cases (85.7%), good in 1 case (7.1%) and fair in 1 case (7.1%) among 14 cases of meniscal repair, and the excellent in 4 cases (66.7%) and good in 2 cases (33.3%) among 6 cases of partial meniscectomy according to the Ikeuchi criteria, There was a significant improvement of Lysholm score after surgery, 92.3 postoperatively compared with 56.6 preoperatively (p<0.0001, paired t-test). Conclusion: The fracture of the lateral tibial plateau did not seem to affect on the healing of the meniscus repair and partial meniscectomy.

  • PDF

New Fiduciary Plate and Orientation Marker for High Energy Radiation Therapy (고에너지 방사선치료의 정도관리를 위한 Fiduciary Plate 및 Orientation Marker의 개발)

  • Wu Hong-Gyun;Huh Sun Nyung;Kim Hak Jae
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.69-75
    • /
    • 2004
  • Purpose : A new fiduciary plate and orientation marker have been devised to assist the quality assurance (QA) procedures for port films in radiation therapy department. The plate is used in conjunction with the film/cassette combination during weekly QA procedures, at Seoul National University Hospital (SNUH), in order to verify treatment fields in high radiation therapy. Materials and Methods : A new fiduciary plate was fabricated using an acrylic plate, cerrobend, standard blocking tray and mercury. The acrylic plate had the dimension of $1{\times}25{\times}25$ cm, with two fiduciary markers. The plate was rigidly attached onto the standard blocking tray, thus making it easier to set the fiduciary plate to the center on the radiation field on the linear accelerator. The plate had two 2-mm vertical and horizontal lines, with the minor scales in 2-cm steps. The orientation marker was a small mercury filled disk, which was inserted into the plate. Results : The geometrical structure of the lines in the plate makes it easier to correlate two different images between the simulation and port films. The marker clearly indicated the orientation of the film, for example, the anterior, posterior, left, right and various oblique orientations, without the placement of a conventional orientation marker. Also, the new orientation marker could easily be applied to the simulator by placing the small orientation marker onto the image intensifier or in front of the film/cassette holder. Conclusions : The new fiduciary plate appears to be useful in verifying the treatment fields, and the new orientation marker makes the film orientation simple, which is expected to lower the block fabrication errors.

The Radiological Findings of the Catheters Inserted 10cm Cephaladly in Epidural Space (경막외강내 두측으로 10cm 삽입한 카테터의 X-선상 소견)

  • Chung, So-Young;Lee, Hyo-Keun;Chae, Jin-Ho;Lee, Chul-Seung;Lee, Chul;Kim, Chan;Kim, Soon-Yul
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.298-303
    • /
    • 1995
  • We have inserted epidural catheter for single or continuous injection of a drug for epidural analgesia. It is important to localize the tip of epidural catheter in appropriate site to acquire the most effective analgesia. In epidural block, we observed course and location of the tip of epidural catheter. Subject: 70 patients were divided into group I(non-injection of saline group during catheter insertion) and group II(injection group during catheter insertion). Group I included cervical(n=20), thoracic(n=10), and lumbar(n=20) epidural group. Group II, cervical(n=10), and lumbar(n=10) epidural group. Method: 19G FlexTip $Plus^{TM}$ Epidural Catheter ($Arrow^{(R)}$) was inserted 10cm cephaladly in epidural space with(group II) or without(group I) saline flushing. We observed course and location of the tip of epidural catheter by C-arm image intensifier during injection of contrast media ($Omnipaque^{(R)}$). Result: In group I, the number of tips of epidural catheters located within 2 cm from inserted site were: cervical 14/20(70%), thoracic 2/10(20%). lumbar 16/20(80%). In thoracic epidural blocks, tips of epidural catheters were more cephaladly located than with cervical and lumbar epidural blocks. With cervical epidural blocks, the number of tips of epidural catheters located within 2 cm from insertion site were less in group II than group I (20% vs. 70%). But no significant differences were noted between group I and group II with lumbar epidural block(90% vs. 80%). The number of tips of epidural catheters located around a predicted site were: cervical 2/20(10%), thoracic 4/10(40%), lumbar 0/20(0%) in group I, and cervical 2/10(20%), lumbar 1/10(10%) in group II. Conclusion: It was impossible to predict the exact location of tips of epidural catheters by measuring the inserted length without epidurogram. With many cases, tips of epidural catheters were located around the insertion site in lumbar epidural blocks, and in some cases around the predicted site in thoracic epidural blocks. The results suggests that epidural block should be done at a point near the required band of analgesia.

  • PDF