A Study of the Effect of Model Characteristics on Purchasing intentions and Brand Attitudes (광고모델 특성이 구매의도와 브랜드태도에 미치는 영향)

  • Kim, Sung-Duck;Youn, Myoung-Kil;Kim, Ki-Soo
    • Journal of Distribution Science
    • /
    • v.10 no.4
    • /
    • pp.47-53
    • /
    • 2012
  • Businesses make use of advertising strategy using models to give consumers efficient product information. Modern advertisements often make use of models for greater reminiscence to create messages and remind viewers of the product. The purpose of this study was to examine the characteristics of each type of model. The subjects were 230 college students in their twenties or older, and the material was collected from October 20, 2011 to November 5, 2011 to examine the effects of model characteristics on buying intention as well as attitude toward a brand. A questionnaire survey was used; investigators gave one copy to each interviewee. The study investigated the characteristics of each model using a questionnaire of each 40 copies with five kinds of photographs. The characteristics of models had great influence on buying intention and attitude toward the brand: First, factor 2 (being honest and virtuous and having good credit and a good press assessment) and factor 3 (being interesting and a good communicator and creating good memories) had great influence on buying intention. Factor 2 was explained by reliability, and factor 3 by the efficiency of the model in creating a feeling. Second, factors 1 (being attractive, smart, unique, friendly, loved by others, and popular), 2, and 3 influenced attitude toward brand. Factor 1 encapsulated the outgoing characteristics of a model, factor 2 was based on reliability, and factor 3 was based on the efficiency of the model in creating a feeling. The model's positive effects on buying intention and attitudes toward brand shall be examined. For their positive influence on buying intention, reliability and efficiency shall be given attention. For their positive influence on attitude toward brand, creating a good impression, having outgoing characteristics, being reliable, and efficiency shall be given attention. The findings were as follows: Model characteristics influencing buying intention were similar to those influencing attitude toward brand. The differences were as follows. First, reliability and efficiency influenced buying intention. When customers were asked to consider the influence on buying intention of an advertisement, regardless of the strength of the buying intention, they considered these two characteristics. Customers decided to buy based not only on the credibility of the product as presented in the advertisement but also the transmission of the contents of the advertisement. Second, outgoing characteristics, reliability, and efficiency influenced attitude toward a brand. The attitude toward a brand was said to be the attitude toward the business. The attitude is produced even after buying, so businesses view it as very important. The attitude might vary depending upon the model used rather than the brand. Therefore, a model with outgoing characteristics was thought to be important. Therefore, attitude toward a brand whose model influenced buying intention as well as attitude toward brand had outgoing characteristics. The result is that an image the model was related to attitude toward the brand. As such, customers would buy the goods advertised. However, an outgoing image of a model was also important to create a positive attitude toward a business brand. For instance, talent Park Gyeong-Rim's photo was used to promote cosmetics about 10 years ago. When she worked as a model of cosmetics products, she had to make compensation for losses and damages because she made a mistake on a talk show program. At that time, customers who had bought the cosmetics product asked for refunds of several billion won. As such, models who are said to be the face of the businesses they represent can play an important role. To advertise in the most attractive and effective way, the current image of a model should be investigated by examining current activities and news articles after selecting the model, and the model's efficiency and attitude toward the brand should be examined. Factors that stimulate customers' buying decisions can be used to plan advertisement that have positive influence on a brand. This study had the limitation of investigating mainly college students and there were insufficient copies of the questionnaire. The investigation was not done widely but in detail so that a concrete investigation could not be done. Further studies shall supplement these shortcomings and discuss new directions.

  • PDF

Consumer's Negative Brand Rumor Acceptance and Rumor Diffusion (소비자의 부정적 브랜드 루머의 수용과 확산)

  • Lee, Won-jun;Lee, Han-Suk
    • Asia Marketing Journal
    • /
    • v.14 no.2
    • /
    • pp.65-96
    • /
    • 2012
  • Brand has received much attention from considerable marketing research. When consumers consume product or services, they are exposed to a lot of brand related stimuli. These contain brand personality, brand experience, brand identity, brand communications and so on. A special kind of new crisis occasionally confronting companies' brand management today is the brand related rumor. An important influence on consumers' purchase decision making is the word-of-mouth spread by other consumers and most decisions are influenced by other's recommendations. In light of this influence, firms have reasonable reason to study and understand consumer-to-consumer communication such as brand rumor. The importance of brand rumor to marketers is increasing as the number of internet user and SNS(social network service) site grows. Due to the development of internet technology, people can spread rumors without the limitation of time, space and place. However relatively few studies have been published in marketing journals and little is known about brand rumors in the marketplace. The study of rumor has a long history in all major social science. But very few studies have dealt with the antecedents and consequences of any kind of brand rumor. Rumor has been generally described as a story or statement in general circulation without proper confirmation or certainty as to fact. And it also can be defined as an unconfirmed proposition, passed along from people to people. Rosnow(1991) claimed that rumors were transmitted because people needed to explain ambiguous and uncertain events and talking about them reduced associated anxiety. Especially negative rumors are believed to have the potential to devastate a company's reputation and relations with customers. From the perspective of marketer, negative rumors are considered harmful and extremely difficult to control in general. It is becoming a threat to a company's sustainability and sometimes leads to negative brand image and loss of customers. Thus there is a growing concern that these negative rumors can damage brands' reputations and lead them to financial disaster too. In this study we aimed to distinguish antecedents of brand rumor transmission and investigate the effects of brand rumor characteristics on rumor spread intention. We also found key components in personal acceptance of brand rumor. In contextualist perspective, we tried to unify the traditional psychological and sociological views. In this unified research approach we defined brand rumor's characteristics based on five major variables that had been found to influence the process of rumor spread intention. The five factors of usefulness, source credibility, message credibility, worry, and vividness, encompass multi level elements of brand rumor. We also selected product involvement as a control variable. To perform the empirical research, imaginary Korean 'Kimch' brand and related contamination rumor was created and proposed. Questionnaires were collected from 178 Korean samples. Data were collected from college students who have been experienced the focal product. College students were regarded as good subjects because they have a tendency to express their opinions in detail. PLS(partial least square) method was adopted to analyze the relations between variables in the equation model. The most widely adopted causal modeling method is LISREL. However it is poorly suited to deal with relatively small data samples and can yield not proper solutions in some cases. PLS has been developed to avoid some of these limitations and provide more reliable results. To test the reliability using SPSS 16 s/w, Cronbach alpha was examined and all the values were appropriate showing alpha values between .802 and .953. Subsequently, confirmatory factor analysis was conducted successfully. And structural equation modeling has been used to analyze the research model using smartPLS(ver. 2.0) s/w. Overall, R2 of adoption of rumor is .476 and R2 of intention of rumor transmission is .218. The overall model showed a satisfactory fit. The empirical results can be summarized as follows. According to the results, the variables of brand rumor characteristic such as source credibility, message credibility, worry, and vividness affect argument strength of rumor. And argument strength of rumor also affects rumor intention. On the other hand, the relationship between perceived usefulness and argument strength of rumor is not significant. The moderating effect of product involvement on the relations between argument strength of rumor and rumor W.O.M intention is not supported neither. Consequently this study suggests some managerial and academic implications. We consider some implications for corporate crisis management planning, PR and brand management. This results show marketers that rumor is a critical factor for managing strong brand assets. Also for researchers, brand rumor should become an important thesis of their interests to understand the relationship between consumer and brand. Recently many brand managers and marketers have focused on the short-term view. They just focused on strengthen the positive brand image. According to this study we suggested that effective brand management requires managing negative brand rumors with a long-term view of marketing decisions.

  • PDF

The Evaluation of Reconstruction Method Using Attenuation Correction Position Shifting in 3D PET/CT (PET/CT 3D 영상에서 감쇠보정 위치 변화 방법을 이용한 영상 재구성법의 평가)

  • Hong, Gun-Chul;Park, Sun-Myung;Jung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.172-176
    • /
    • 2010
  • Purpose: The patients' moves occurred at PET/CT scan will cause the decline of correctness in results by resulting in inconsistency of Attenuation Correction (AC) and effecting on quantitative evaluation. This study has evaluated the utility of reconstruction method using AC position changing method when having inconsistency of AC depending on the position change of emission scan after transmission scan in obtaining PET/CT 3D image. Materials and Methods: We created 1 mL syringe injection space up to ${\pm}2$, 6, 10 cm toward x and y axis based on central point of polystyrene ($20{\times}20110$ cm) into GE Discovery STE16 equipment. After projection of syringe with $^{18}F$-FDG 5 kBq/mL, made an emission by changing the position and obtained the image by using AC depending on the position change. Reconstruction method is an iteration reconstruction method and is applied two times of iteration and 20 of subset, and for every emission data, decay correction depending on time pass is applied. Also, after setting ROI to the position of syringe, compared %Difference (%D) at each position to radioactivity concentrations (kBq/mL) and central point. Results: Radioactivity concentrations of central point of emission scan is 2.30 kBq/mL and is indicated as 1.95, 1.82 and 1.75 kBq/mL, relatively for +x axis, as 2.07, 1.75 and 1.65 kBq/mL for -x axis, as 2.07, 1.87 and 1.90 kBq/mL for +y axis and as 2.17, 1.85 and 1.67 kBq/mL for -y axis. Also, %D is yield as 15, 20, 23% for +x axis, as 9, 23, 28% for -x axis, as 12, 21, 20% for +y axis and as 8, 22, 29% for -y axis. When using AC position changing method, it is indicated as 2.00, 1.95 and 1.80 kBq/mL, relatively for +x axis, as 2.25, 2.15 and 1.90 kBq/mL for -x axis, as 2.07, 1.90 and 1.90 kBq/mL for +y axis, and as 2.10, 2.02, and 1.72 kBq/mL for -y axis. Also, %D is yield as 13, 15, 21% for +x axis, as 2, 6, 17% for -x axis, as 9, 17, 17% for +y axis, and as 8, 12, 25% for -y axis. Conclusion: When in inconsistency of AC, radioactivity concentrations for using AC position changing method increased average of 0.14, 0.03 kBq/mL at x, y axis and %D was improved 6.1, 4.2%. Also, it is indicated that the more far from the central point and the further position from the central point under the features that spatial resolution is lowered, the higher in lowering of radioactivity concentrations. However, since in actual clinic, attenuation degree increases more, it is considered that when in inconsistency, such tolerance will be increased. Therefore, at the lesion of the part where AC is not inconsistent, the tolerance of radioactivity concentrations will be reduced by applying AC position changing method.

  • PDF

Efficient Red-Color Emission of InGaN/GaN Double Hetero-Structure Formed on Nano-Pyramid Structure

  • Go, Yeong-Ho;Kim, Je-Hyeong;Gong, Su-Hyeon;Kim, Ju-Seong;Kim, Taek;Jo, Yong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.174-175
    • /
    • 2012
  • (In, Ga) N-based III-nitride semiconductor materials have been viewed as the most promising materials for the applications of blue and green light emitting devices such as light-emitting diodes (LEDs) and laser diodes. Although the InGaN alloy can have wide range of visible wavelength by changing the In composition, it is very hard to grow high quality epilayers of In-rich InGaN because of the thermal instability as well as the large lattice and thermal mismatches. In order to avoid phase separation of InGaN, various kinds of structures of InGaN have been studied. If high-quality In-rich InGaN/GaN multiple quantum well (MQW) structures are available, it is expected to achieve highly efficient phosphor-free white LEDs. In this study, we proposed a novel InGaN double hetero-structure grown on GaN nano-pyramids to generate broad-band red-color emission with high quantum efficiency. In this work, we systematically studied the optical properties of the InGaN pyramid structures. The nano-sized hexagonal pyramid structures were grown on the n-type GaN template by metalorganic chemical vapor deposition. SiNx mask was formed on the n-type GaN template with uniformly patterned circle pattern by laser holography. GaN pyramid structures were selectively grown on the opening area of mask by lateral over-growth followed by growth of InGaN/GaN double hetero-structure. The bird's eye-view scanning electron microscope (SEM) image shows that uniform hexagonal pyramid structures are well arranged. We showed that the pyramid structures have high crystal quality and the thickness of InGaN is varied along the height of pyramids via transmission electron microscope. Because the InGaN/GaN double hetero-structure was grown on the nano-pyramid GaN and on the planar GaN, simultaneously, we investigated the comparative study of the optical properties. Photoluminescence (PL) spectra of nano-pyramid sample and planar sample measured at 10 K. Although the growth condition were exactly the same for two samples, the nano-pyramid sample have much lower energy emission centered at 615 nm, compared to 438 nm for planar sample. Moreover, nano-pyramid sample shows broad-band spectrum, which is originate from structural properties of nano-pyramid structure. To study thermal activation energy and potential fluctuation, we measured PL with changing temperature from 10 K to 300 K. We also measured PL with changing the excitation power from 48 ${\mu}W$ to 48 mW. We can discriminate the origin of the broad-band spectra from the defect-related yellow luminescence of GaN by carrying out PL excitation experiments. The nano-pyramid structure provided highly efficient broad-band red-color emission for the future applications of phosphor-free white LEDs.

  • PDF

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

The Usefulness of F-18 FDG Whole Body PET in the Evaluation of Postoperative Recurrence of Cancer (수술 후 암 재발 판정에 있어서 전신 F-18 FDG-PET의 유용성)

  • Kang, Won-Jun;So, Young;Jeong, Jae-Min;Kwark, Cheol-Eun;Lee, Dong-Soo;Kang, Soon-Bem;Jung, Hee-Won;Kim, Kwang-Hyun;Park, Jae-Gahb;Lee, Myung-Chul;Koh, Chang-Soon;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.372-380
    • /
    • 1997
  • The purpose of this study was to evaluate the usefulness of whole body F-18 FDG PET scan for detecting postoperative recurrence of cancer. One hundred four cancer patients after operation were enrolled(14 brain tumor, 15 head and neck cancer, 23 gynecologic cancer, 16 gastrointestinal cancer, 16 thyroid cancer, and 20 other cancers). Besides conventional images(CI) including CT and MRI, F-18 FDG PET scan was obtained on ECAT EXACT 47 scanner(Siemens-CTI), beginning 60 minutes after injection of 370MBq(10mCi) of F-18 FDG. Regional scan was also obtained with emission image. Transmission images using Ge-68 were carried out for attenuation correction in both whole body and regional images. Findings of PET, and CI were confirmed by pathology or clinical follow up. The sensitivity and specificity of PET for detecting recurrence were 94% and 92%, respectively. Contrarily, the sensitivity and specificity of CI were 78% and 68%. CI results were negative and PET results were positive in 11 cases. The biopsy or clinical follow-up of those cases confirmed recurrence of tumor. False negative cases of CI were frequent in patients with gynecologic cancers. Also we measured the serum concentration of tumor markers in patients with gynecologic cancer(CA125), thyroid cancer(thyroglobulin), and colorectal cancer(CEA). The sensitivity and specificity of tumor markers were 71% and 84%, respectively, We conclude that F-18 FDG PET can be used valuably in detecting recurrent foci of a wide variety of malignancy compared to conventional diagnostic methods.

  • PDF

A Study on GPU-based Iterative ML-EM Reconstruction Algorithm for Emission Computed Tomographic Imaging Systems (방출단층촬영 시스템을 위한 GPU 기반 반복적 기댓값 최대화 재구성 알고리즘 연구)

  • Ha, Woo-Seok;Kim, Soo-Mee;Park, Min-Jae;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.459-467
    • /
    • 2009
  • Purpose: The maximum likelihood-expectation maximization (ML-EM) is the statistical reconstruction algorithm derived from probabilistic model of the emission and detection processes. Although the ML-EM has many advantages in accuracy and utility, the use of the ML-EM is limited due to the computational burden of iterating processing on a CPU (central processing unit). In this study, we developed a parallel computing technique on GPU (graphic processing unit) for ML-EM algorithm. Materials and Methods: Using Geforce 9800 GTX+ graphic card and CUDA (compute unified device architecture) the projection and backprojection in ML-EM algorithm were parallelized by NVIDIA's technology. The time delay on computations for projection, errors between measured and estimated data and backprojection in an iteration were measured. Total time included the latency in data transmission between RAM and GPU memory. Results: The total computation time of the CPU- and GPU-based ML-EM with 32 iterations were 3.83 and 0.26 see, respectively. In this case, the computing speed was improved about 15 times on GPU. When the number of iterations increased into 1024, the CPU- and GPU-based computing took totally 18 min and 8 see, respectively. The improvement was about 135 times and was caused by delay on CPU-based computing after certain iterations. On the other hand, the GPU-based computation provided very small variation on time delay per iteration due to use of shared memory. Conclusion: The GPU-based parallel computation for ML-EM improved significantly the computing speed and stability. The developed GPU-based ML-EM algorithm could be easily modified for some other imaging geometries.

ULTRASTRUCTURAL ANALYSIS OF TOOTH PULP AFFERENTS TERMINALS IN THE MEDULLARY DORSAL HORN OF THE RAT (치수유래 구심성 신경섬유의 삼차신경 감각핵군에서의 연접특성)

  • Bae, Yong-Chul;Lee, Eun-Hee;Choy, Min-Ki;Hong, Su-Hyung;Kim, Hyun-Jung;Na, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.2
    • /
    • pp.219-227
    • /
    • 2001
  • Little is known about processing mechanism of pain sensation of the oral cavity at the 1st synapse of trigeminal sensory nuclei. Serial ultrathin sections of tooth pulp afferent terminals, identified by the transganglionic transport of 1% wheatgerm agglutinin conjugated horseradish peroxidase, were investigated with electron microscope. Quantitative ultrastructural analysis was performed on digitizing tablet connected to Macintoshi personal computer (software; NIH Image 1.60, NIH, Bethesda, MD). Labeled boutons could be classified into two types by the shapes of containing vesicles : S bouton, which contained mainly spherical vesicles (Dia. 45-55 nm) and few large dense cored vesicles (Dia, 80-120nm), and LDCV bouton, which contained spherical vesicles as well as large number of large dense cored vesicles. Most of the parameters on the ultrastructural characteristic and synaptic organization of labeled boutons were similar between S and LDCV boutons, except shapes of containing vesicles. Majority of the labeled boutons showed simple synaptic arrangement. The labeled boutons were frequency presynaptic to dendritic spine, and to a lesser extent, dendritic shaft. They rarely synapsed with soma and adjacent proximal dendrite. A small proportion of labeled boutons made synaptic contacts with presynaptic, pleomorphic vesicles containing endings and synaptic triad. Morphometric parameters of labeled boutons including volume and surface area, total apposed area, mitochondrial volume, active zone area, vesicle number and density showed wide variation and these were not significantly different between S and LDCV boutons. The present study revealed characteristic features on ultrastructure and synaptic connection of pulpal afferents which may involved in transmission of oral pain sensation.

  • PDF

'The Same Scenery' and 'a Different Landscape' Included in "Real-Scenery Landscape Painting", an Essay to Determine Meaning - Centering around Paintings of Chong Seok Jeong in the 18th-19th Centuries - (실경산수화에 담긴 '같은 경관' 그러나 '다른 풍경', 그 의미 찾기 - 18.19C 총석정 그림을 중심으로 -)

  • Rho, Jae-Hyun;Jang, Il-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.5
    • /
    • pp.82-93
    • /
    • 2008
  • This research focused on the process in which 'the same scenery' is recognized and represented as 'a different landscape' to determine the symbols and meaning of the scenery and landscape included in real-scenery landscape paintings of the 18th-19th centuries. As a result of analyzing the visual points, the content and expressions of 25 real-scenery landscape paintings of Chong Seok Jeong(叢石亭), it can be seen that the transmission of a kind of semiotic landscape on the basis of a specific symbol was accomplished naturally through imitation and representation for the purpose of the expression of Chong Seok Jeong-like idealized scenery. This shows that the unique images of Chong Seok Jeong have long been passed down after taking root as a unique benchmark The meaningful symbol of 'a strange Saseonbong(四仙峰)', which is broken by the spray after rising high, and 'a pine forest' have both been transmitted as being in the manner of Chong Seok Jeong. This has been equipped with the stereo-type scene by being a collective symbolization as the psycho-scenes in memory element of Chong Seok Jeong. Through the pictures of both Gyeomjae(謙齋) and Danweon(檀園), the process by which a specific painter's pictures become acculturated is highly interesting. The scenery expressed in these pictures was clearly that of a landscape of which its particularly emotions and remembrances were repainted through the experience of several places and original sketches. This can be explained as the concept in which the image from 'a specific scenery' gained through actual experience, that is, a personal feeling, has been expressed. The picture that was expressed as a different figure even at the same visual point for the same scenery is the result that was redefined through the scenery subject's recognition. Also, the modification of the scenery object can be colorful through meditation and Sachu(邪推: guessing with wicked doubt). The scenery recognized newly through adoption, omission and emphasis, it is 'the specific scenery' in the heart and is a figure having been more similar to 'a landscape' if the objective life reproduction before being acculturated is a figure similar to the scenery. So, the concept looks like being very persuasive that 'the nature with objectivity captured sensuously' simply is the scenery, and that 'the subjective phenomenon having acquired the cultural nature by being introspected in the method of aesthetic nostalgia is a landscape'.

Assessment of Attenuation Correction Techniques with a $^{137}Cs$ Point Source ($^{137}Cs$ 점선원을 이용한 감쇠 보정기법들의 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyoung;Park, Yun-Young;Park, Hae-Joung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.57-68
    • /
    • 2005
  • Purpose: The objective of this study was to assess attenuation correction algorithms with the $^{137}Cs$ point source for the brain positron omission tomography (PET) imaging process. Materials & Methods: Four different types of phantoms were used in this study for testing various types of the attenuation correction techniques. Transmission data of a $^{137}Cs$ point source were acquired after infusing the emission source into phantoms and then the emission data were subsequently acquired in 3D acquisition mode. Scatter corrections were performed with a background tail-fitting algorithm. Emission data were then reconstructed using iterative reconstruction method with a measured (MAC), elliptical (ELAC), segmented (SAC) and remapping (RAC) attenuation correction, respectively. Reconstructed images were then both qualitatively and quantitatively assessed. In addition, reconstructed images of a normal subject were assessed by nuclear medicine physicians. Subtracted images were also compared. Results: ELEC, SAC, and RAC provided a uniform phantom image with less noise for a cylindrical phantom. In contrast, a decrease in intensity at the central portion of the attenuation map was noticed at the result of the MAC. Reconstructed images of Jaszack and Hoffan phantoms presented better quality with RAC and SAC. The attenuation of a skull on images of the normal subject was clearly noticed and the attenuation correction without considering the attenuation of the skull resulted in artificial defects on images of the brain. Conclusion: the complicated and improved attenuation correction methods were needed to obtain the better accuracy of the quantitative brain PET images.