• 제목/요약/키워드: Image Tracing

검색결과 242건 처리시간 0.017초

치조골 폭경과 임플랜트 고정체의 직경에 따른 지지조직의 응력분포 (STRESS ANALYSIS OF SUPPORTING TISSUES ACCORDING TO IMPLANT FIXTURE DIAMETER AND RESIDUAL ALVEOLAR BONE WIDTH)

  • 한상운;방몽숙;양홍서;박상원;박하옥;임현필
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.506-521
    • /
    • 2007
  • Statement of problem: The cumulative success rate of wide implant is still controversial. Some previous reports have shown high success rate, and some other reports shown high failure rate. Purpose: The aim of this study was to analyze, and compare the biomechanics in wide implant system embeded in different width of crestal bone under different occlusal forces by finite element approach. Material and methods: Three-dimensional finite element models were created based on tracing of CT image of second premolar section of mandible with one implant embedded. One standard model (6mm-crestal bone width, 4.0mm implant diameter central position) was created. Varied crestal dimension(4, 6, 8 mm), different diameter of implants(3.3, 4.0, 5.5, 6.0mm), and buccal position implant models were generated. A 100-N vertical(L1) and 30 degree oblique load from lingual(L2) and buccal(L3) direction were applied to the occlusal surface of the crown. The analysis was performed for each load by means of the ANSYS V.9.0 program. Conclusion: 1. In all cases, maximum equivalent stress that applied $30^{\circ}$ oblique load around the alveolar bone crest was larger than that of the vertical load. Especially the equivalent stress that loaded obliquely in buccal side was larger. 2. In study of implant fixture diameter, stress around alveolar bone was decreased with the increase of implant diameter. In the vertical load, as the diameter of implant increased the equivalent stress decreased, but equivalent stress increased in case of the wide implant that have a little cortical bone in the buccal side. In the lateral oblique loading condition, the diameter of implant increased the equivalent stress decreased, but in the buccal oblique load, there was not significant difference between the 5.5mm and 6.0mm as the wide diameter implant. 3. In study of alveolar bone width, equivalent stress was decreased with the increase of alveolar bone width. In the vertical and oblique loading condition, the width of alveolar bone increased 6.0mm the equivalent stress decreased. But in the oblique loading condition, there was not a difference equivalent stress at more than 6.0mm of alveolar bone width. 4. In study of insertion position of implant fixture, even though the insertion position of implant fixture move there was not a difference equivalent stress, but in the case of little cortical bone in the buccal side, value of the equivalent stress was most unfavorable. 5. In all cases, it showed high stress around the top of fixture that contact cortical bone, but there was not a portion on the bottom of fixture that concentrate highly stress and play the role of stress dispersion. These results demonstrated that obtaining the more contact from the bucco-lingual cortical bone by installing wide diameter implant plays an important role in biomechanics.

다중 원격탐사 자료를 활용한 해양 오염 추적 모의 실험 방안에 대한 연구 (Simulation Approach for the Tracing the Marine Pollution Using Multi-Remote Sensing Data)

  • 김근용;김의현;최준명;신지선;김원국;이광재;손영백;유주형
    • 대한원격탐사학회지
    • /
    • 제36권2_2호
    • /
    • pp.249-261
    • /
    • 2020
  • 다중 플랫폼/센서를 활용한 연안 모니터링은 연안 해양환경 변화와 다양한 재해/재난을 높은 시공간 해상도로 정확하게 이해하기 위한 매우 중요한 수단이다. 하지만 다중 플랫폼과 센서를 복합적으로 이용한 통합 관측 연구는 미비한 실정이고, 통합 관측을 통한 효율성, 융합 한계성 등에 대해 평가된 바 없다. 본 연구에서는 다중 원격탐사 플랫폼/센서를 이용한 모의실험을 통해 통합 관측 방법을 제시하고, 그 효용성과 한계점을 진단하였다. 다양한 해양 재해, 재난을 모사하기 위하여 Rhodamine WT (RWT) 형광염료를 이용하여 통합 현장조사를 수행하였다. 2019년 9월 남해-여수 해역에 형광염료를 주입 후 위성(Kompsat-2/3/3A, Landsat-8 Operational Land Imager (OLI), Sentinel-3 Ocean and Land Colour Instrument (OLCI), GOCI), 무인항공기 (Mavic 2 pro, Inspire 2), 유인항공기 플랫폼을 이용하여 염료 패치의 분포와 이동을 탐지하였다. 형광염료 주입 초기 패치 규모는 2,600 ㎡ 이었고, 약 138분 후 62,000 ㎡ 규모까지 확산되었다. RWT 패치는 처음 주입된 지점으로 부터 점차 남서 방향으로 이동하였고, 이는 현장 모의 실험이 진행되는 동안 조위(고조: 7시 7분(286 cm), 저조: 13시 9분(73 cm))가 점차 낮아짐에 따라 조석이 남동 방향으로 흐르는 것과 유사하였다. 무인항공기 영상은 공간해상도와 시간해상도 측면에서 가장 높은 해상력을 보인 반면 탐지 영역이 가장 좁았다. 위성의 경우 탐지 영역은 넓었지만 재방문 주기가 길기 때문에 운용성 측면에서 타 플랫폼과 비교하여 다소 한계가 있었다. 또한 Sentinel-3 OLCI와 GOCI의 경우 분광해상도와 신호 대 잡음비(signal to noise ratio)가 가장 높았지만 소규모 형광염료 탐지에는 공간해상도 측면에서 제한적이었다. 유인항공기에 탑재된 초다분광 영상의 경우 분광해상도가 가장 높았지만 이 역시 운용성 측면에서 다소 제한적이었다. 다중 플랫폼 통합관측 연구를 통해 시간과 공간뿐만 아니라 분광 해상력 증가 향상을 확인 가능하였다. 향후 이 연구 결과가 연안 수치모델과 연계된다면 오염 물질의 이동확산 예측이 가능할 것으로 생각되고, 수치모델의 입력 및 검증 자료로 활용하여 모델 정확도 향상에 기여할 수 있을 것으로 기대된다.