• Title/Summary/Keyword: Image Superposition

Search Result 47, Processing Time 0.024 seconds

Elastic solutions for shallow tunnels excavated under non-axisymmetric displacement boundary conditions on a vertical surface

  • Wang, Ling;Zou, Jin-Feng;Yang, Tao;Wang, Feng
    • Geomechanics and Engineering
    • /
    • v.19 no.3
    • /
    • pp.201-215
    • /
    • 2019
  • A new approach of analyzing the displacements and stress of the surrounding rock for shallow tunnels excavated under non-axisymmetric displacement boundary conditions on a vertical surface is investigated in this study. In the proposed approach, by using a virtual image technique, the shear stress of the vertical ground surface is revised to be zero, and elastic solutions of the surrounding rock are obtained before stress revision. To revise the vertical normal stress and shear stress of horizontal ground surface generated by the combined action of the actual and image sinks, the harmonic functions and corresponding stress function solutions were adopted. Based on the Boussinesq's solutions and integral method, the horizontal normal stress of the vertical ground surface is revised to be zero. Based on the linear superposition principle, the final solution of the displacements and stress were proposed by superimposing the solutions obtained by the virtual image technique and the stress revision on the horizontal and vertical ground surfaces. Furthermore, the ground settlements and lateral displacements of the horizontal and vertical ground surfaces are derived by the proposed approach. The proposed approach was well verified by comparing with the numerical method. The discussion based on the proposed approach in the manuscript shows that smaller horizontal ground settlements will be induced by lower tunnel buried depths and smaller limb distances. The proposed approach for the displacement and stress of the surrounding rocks can provide some practical information about the surrounding rock stability analysis of shallow tunnels excavated under non-axisymmetric displacement boundary conditions on a vertical surface.

Trial of Computer Simulation of Image Reconstruction from Incomplete Data for New CT with Reduced Exposure

  • Hayakawa, Yoshinori;Furuya, Toshimitsu;Sakakibara, Norifumi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.382-384
    • /
    • 2002
  • Filtered-Back-Projection technique is used in X-ray CT image reconstruction. This requires X-ray transmission data from all directions. As the transverse cross-section of the body is approximately 50 cm, transmitted X-rays in this direction are strongly attenuated. If X-ray transmission data in this direction is avoided, exposure to the patients seems to be reduced one 20th of usual value. Some alternative method has to be found for clinically sufficient image quality. New methods are under development and tentative results are reported that utilizes the principle of superposition.

  • PDF

Determination and classification of intraoral phosphor storage plate artifacts and errors

  • Deniz, Yesim;Kaya, Seher
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.219-228
    • /
    • 2019
  • Purpose: The aim of this study was to determine the reasons and solutions for intraoral phosphor storage plate (PSP) image artifacts and errors, and to develop an appropriate classification of the artifacts. Materials and Methods: This study involved the retrospective examination of 5,000 intraoral images that had been obtained using a phosphor plate system. Image artifacts were examined on the radiographs and classified according to possible causative factors. Results: Artifacts were observed in 1,822 of the 5,000 images. After examination of the images, the errors were divided into 6 groups based on their causes, as follows: images with operator errors, superposition of undesirable structures, ambient light errors, plate artifacts (physical deformations and contamination), scanner artifacts, and software artifacts. The groups were then re-examined and divided into 45 subheadings. Conclusion: Identification of image artifacts can help to improve the quality of the radiographic image and control the radiation dose. Knowledge of the basic physics and technology of PSP systems could aid to reduce the need for repeated radiography.

The superposition of Science and Imagination (과학과 상상력의 중첩성)

  • HONG, Myung-Hee
    • Cross-Cultural Studies
    • /
    • v.34
    • /
    • pp.93-114
    • /
    • 2014
  • Gaston Bachelard had a revolutionary progress in the field of human understanding by proposing his theory of image and imagination. His theory of the new image was so powerful, almost all areas of human science, particularly that of literary criticism, were strongly influenced and this influence continues until today. Today almost everyone accepts his theory of the image without much objection, but not rarely asked where began his transfer from the philosophy of science to the images. We propose a hypothesis that the beginning of the new concept of Bachelard's image was inspired by studies of contemporary science, especially quantum mechanics. The Heisenberg's uncertainty principle was the core of quantum mechanics, and opens new perspectives on the material world. We could summarize the message of the uncertainty principle : the material world is made up of various layers, and the material can not be measured by the location and movement at the same time. So we must have a new point of view of another dimension to know this material world. Bachelard had accepted this view of Heisenberg and developed his own theory of epistemological rupture. What is revolutionary in the theory of Bachelard's image is the fact that he looked at the images with the new perspective. The human psyche is another world compared to the rational world that dominates our daily lives. Bachelard insists that the image can not be explained by the concept. The fantasy world is a totally different world to that of rationality. That is why it can not be explained by the language of rationality as the concept. The imaginary world exists independently of the real world, but it is superimposed on the real world. These two worlds are influencing each other, and it is between these two world where our daily lives continues. The declaration of Bachelard 'image is a specific reality' is never a metaphor or rhetorical expression. This is an ontological expression that must truthfully. The imaginary world is a world built on the image and it works according to its own law. It is not a representation or copy of the real world. But the world of imagination are not alone. It exists in the same time and space with the world of science. It is superimposed with the world of science. Both two world influence each other. Bachelard has made a revolutionary change by studying the images. He gave them their own place. It has changed the views on the images that were treated as mere representations of reality. Thanks to him, the image can have its own value, that of a factor that creates reality. Bachelard shows how we can go deep into the source of being and the universe if we look at the pictures with the eyes of other dimensions.

System Development and Fundamental Study of CCD Camera Based Electronic Portal Imaging Device (CCD Camera 기반 실시간 방사선치료조사면 검증 시스템 개발 및 화질개선을 위한 기초연구)

  • Jang, Gi-Won;Park, Ji-Koon;Lee, Dong-Gil;Kim, Jin-Yeong;Nam, Sang-Hee;Ha, Sung-Whan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.380-383
    • /
    • 2003
  • The purpose of this study is to develope prototype EPID system and improve image quality of radiation therapy field imaging system using CCD camera. For this research we used Linac(Clinac 4/100), Copper metal plate, $Gd_2O_2S_2$ phosphor and CCD camera(Photronic). In this study we find best thickness of buil-up metal plate and acquired projection image of humanoid head phantom. Also we enhanced raw image data using superposition and histogram stretching method. Through the thickness optimized of metal plate and image processing, we confirmed of an improved image quality of an EPID system using CCD camera. As result, highest quality image was acquired at 1mm thickness of Copper metal plate and improved image quality by image processing methods.

  • PDF

Depth sensitivity of stereoscopic displays

  • Choi, Byeong-Hwa;Choi, Dong-Wook;Lee, Ja-Eun;Lee, Seung-Bae;Kim, Sung-Chul
    • Journal of Information Display
    • /
    • v.13 no.1
    • /
    • pp.43-49
    • /
    • 2012
  • Depth sensitivity is considered one of the factors influencing 3D displays the most. In this paper, the perceptual 3D depth was quantitatively measured to compare the depth difference among the display devices. No difference was found in the typical display performance among the devices, but the subjective evaluation of the depth sensitivity where the disparity was varied showed that the organic light emitting diode (OLED) had the highest performance, mainly due to its almost 0% crosstalk, one of the features of OLED. Crosstalk is a form of image superposition that greatly affects the depth sensitivity. The experiment results showed that the quantitative depth sensitivity varies due to geometric factors such as disparity, viewing distance, and subjective sensitivity, depending on the display image characteristics, such as crosstalk and contrast.

EXAMINATION OF SPATIAL INTEGRATION METHOD FOR EXTRACTING THE RCS OF A CALIBRATION TARGET FROM SAR IMAGES

  • Na, Jae-Ho;Oh, Yi-Sok
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.254-257
    • /
    • 2007
  • This paper presents an examination of the spatial integration method for extracting the RCS of a trihedral corner reflector from SAR images for SAR external calibration. An exact external radiometric calibration technique is required for extracting an exact calibration constant. Therefore, we examine the accuracy of the spatial integration method, which is commonly used for the SAR external radiometric calibration. At first, an SAR image for a trihedral corner reflector is simulated with a high-resolution SAR impulse response with a known theoretical RCS of the reflector, and a background clutter image for the high resolution SAR system is also generated. Then, a SAR image in a high resolution is generated for a trihedral comer reflector located on a background clutter by superposition of the two SAR images. The radar cross section of a trihedral corner reflector in the SAR image is retrieved by integrating the radar signals of the pixels adjacent to the reflector for various size of the integration area. By comparison of the measured RCS by the integration method and the theoretical RCS of the reflector, the effect of the size of the integration area on the extraction of the calibration constant is examined.

  • PDF

The Enhancement of Inner-solid Image by the Bandwidth Increment of Vertically Spatial Frequency (축 방향 공간주파수 대역의 확장을 통한 고체 내부영상 개선)

  • Koo, Kil-Mo;Kim, Sang-Baik;Kim, Hyun;Jun, Kye-Suk
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.176-180
    • /
    • 2001
  • In this paper, we have studies the images have been reconstructed by using combination of images which has been acquired by the variation of operating frequency. When inner images has been reconstructed, inner image has been superposition by surface state effect. In this case, image enhancement the phase object and enhance the contrast of inner image. In the result of the specimen for the round defect with 2mm diameter, for the types of the depth are 1.5mm, 2mm, 2.5mm, and 3mm, it has been show that the shape of defect has better than before this processing and phase contrast grow large twice. And we have constructed the acoustic microscope by using quadrature detector that is able simultaneously to acquired the amplitude and phase of the reflected signal. Father more we have studied the reconstruction method of the amplitude and phase images and the enhancement method of the defect images' contrast.

  • PDF

Prediction of Cured Cross-sectional Image in Projection Microstereolithography (전사방식 마이크로광조형의 경화 단면형상 예측)

  • Kim, Sung-Hyun;Park, In-Baek;Ha, Young-Myoung;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.4
    • /
    • pp.102-108
    • /
    • 2010
  • Projection microstereolithography is a process of fabricating a micro-structure by using dynamic mask such as digital micromirror device(DMD). DMD shapes the beam into cross-sectional image of structure. Photocurable resin is cured by the beam and stacked layer on top of layer. It is difficult to deliver the beam from the DMD to the photocurable resin without any distortions. We assume that the beam exposed to the resin by 1 pixel of DMD has Gaussian distribution, so the shaped beam reflected by the DMD affects its neighboring area. Curing pattern corresponding to a cross-sectional images is predicted by superposition of pixels of Gaussian distribution and it is similar to cured shape.

Vibration Characteristic Analysis Of Gimbal Structure in Collection Equipment of Image Information (영상정보 수집 장치용 짐발 구조물의 진동특성해석)

  • Lee, Sang-Eun;Lee, Tac-Won
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.2
    • /
    • pp.20-25
    • /
    • 2010
  • A camera module is supported by a gimbal structure in collection equipment of image information. During flight, the gimbal system undergoes serious accelerations with wide frequencies. To get the correct images, the camera module must be stably vibrated under these conditions. If natural frequency unfortunately exists in a exciting frequency range, resonance occurs there. Hence, harmonic responses analysis is needed to know correct vibration characteristic of the gimbal system. Finite element analysis was performed to get an acceleration of the gimbal system by mode superposition after extracting mode shapes and natural frequencies. Considering damping ratio of 2%, the reponses of gimbal structure were calculated from excitations with a design frequency band. As results, a maximum acceleration transmissibility, which is the ratio of response to excitation, was obtained and it can be used to design the gimbal structure effectively.