  • Pregnancy is a unique event in which a fetus develops in the uterus despite being genetically and immunologically different from the mother, and the underlying mechanisms remain poorly understood. To analyze the differential gene expression profiles in nonpregnant and 7 days post coitus (dpc) pregnant uterus of mice, we performed a global proteomic study by 2-D gel electrophoresis (2-DE) and MALDI-TOF-MS. The uterine proteins were separated using 2-DE, Approximately 1,000 spots were detected on staining with Coomassie brilliant blue. An image analysis using Melanie III (Swiss Institute for Bioinformatics) was performed to detect variations in protein spots between pregnant and nonpregnant uterus. Twenty-one spots were identified as differentially expressed proteins, of which 10 were up-regulated proteins such as alpha-fetoprotein, chloride intracellular channel 1, transgelin, heat-shock protein beta-1, and carbonic anhydrase II, while 11 were down-regulated proteins such as X-box binding protein, glutathione S-transferase omega 1, olfactory receptor Olfr204, and metalloproteinase-disintegrin domain containing protein TECADAM. Most of the identified proteins appeared to be related with catabolism, cell growth, metabolism, regulation, cell protection, protein repair, or protection. Our results uncovered key proteins of mouse uterus involved in pregnancy.

The Comparison of Electric Characteristics of Radiation Detective Sensor(a-Se) with changing composition ratio of Arsenic (Arsenic의 첨가량에 따른 방사선 검출센서 (a-Se)의 전기적 특성 비교)

  • Seok, Dae-Woo;Kang, Sang-Sik;Lee, Dong-Gil;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.391-394
    • /
    • 2002
  • There has recently been much interest and research in developing digital x-ray systems based on using amorphous selenium(a-Se) photoconductors as the image receptor. The amorphous selenium layer that is currently being studied for use as an x-ray photoconductor is not pure a-Se but rather amorphous selenium alloyed with arsenic. We fabricated samples using the selenium and arsenic alloy with various concentrations of the arsenic. In this work, x-ray photoconductor using amorphous selenium alloyed with arsenic were fabricated with different concentrations of the arsenic (0.1 wt.%, 0.3wt.%, 0.5wt.%, 1wt.%, 1.5wt.%, 3wt.%, 5wt.%). The seven kind of samples was fabricated with a-Se alloyed with arsenic through vacuum thermal evaporation. We also investigate the arsenic concentration dependence on the device performance in radiation detector. The electric characteristics of radiation detector devices with changing additive ratio of the arsenic is performed by measuring the x-ray induced photocurrent and integrating it over time to find the total charge. The thickness of a-Se is $100{\mu}m$. Bias voltages $3V/{\mu}m$, $6V/{\mu}m$$9V/{\mu}m$ are applied at the samples. As results, the net charge of a-Se 0.3% As sample is $526.0pC/mR/cm^2$ at $9V/{\mu}m$ bias. The net charge is decreased as with the increasing additive ratio of arsenic.

  • PDF

The Effect of Growth Condition on a Soluble Expression of Anti-EGFRvIII Single-chain Antibody in Escherichia coli NiCo21(DE3)

  • Dewi, Kartika Sari;Utami, Ratna Annisa;Hariyatun, Hariyatun;Pratiwi, Riyona Desvy;Agustiyanti, Dian Fitria;Fuad, Asrul Muhamad
    • Microbiology and Biotechnology Letters
    • /
    • v.49 no.2
    • /
    • pp.148-156
    • /
    • 2021
  • Single-chain antibodies against epidermal growth factor receptor variant III (EGFRvIII) are potentially promising agents for developing antibody-based cancer treatment strategies. We described in our previous study the successful expression of an anti-EGFRvIII scFv antibody in Escherichia coli. However, we could also observe the formation of insoluble aggregates in the periplasmic space, limiting the production yield of the active product. In the present study, we investigated the mechanisms by which growth conditions could affect the expression of the soluble anti-EGFRvIII scFv antibody in small-scale E. coli NiCo21(DE3) cultures, attempting to maximize production. The secreted scFv molecules were purified using Ni-NTA magnetic beads and protein characterization was performed using SDS-PAGE and western blot analyses. We used the ImageJ software for protein quantification and determined the antigen-binding activity of the scFv antibody against the EGFRvIII protein. Our results showed that the highest percentage of soluble scFv expression could be achieved under culture conditions that combined low IPTG concentration (0.1 mM), low growth temperature (18℃), and large culture dish surface area. We found moderate-yield soluble scFv production in the culture medium after lactose-mediated induction, which was also beneficial for downstream protein processing. These findings were confirmed by conducting western blot analysis, indicating that the soluble, approximately 30-kDa scFv molecule was localized in the periplasm and the extracellular space. Moreover, the antigen-binding assay confirmed the scFv affinity against the EGFRvIII antigen. In conclusion, our study reveals that low-speed protein expression is preferable to obtain more soluble anti-EGFRvIII scFv protein in an E. coli expression system.

Error Analysis of General X-ray Examination by Using Simulation Training (시뮬레이션 교육을 통한 일반 X선 검사의 오류 분석)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.919-927
    • /
    • 2018
  • The purpose of this study was to present simulation training model for general X-ray examinations and to analyze the errors that occur during the simulation training. From 2012 to 2018, a total of 183 students (77 men and 106 women) participated. The simulated X-ray system used computed radiography (CR) system. The contents of simulation training were patient's care, X-ray examinations accuracy, images stability, etc. As a result, it were found that the patient's position setting error, the accuracy error of the X-ray beam central ray, the image receptor's size and setting error, the error of the grid use, the marking error, and the error of X-ray exposure technical factors. It is expected that improved practical general X-ray examinations training of radiographer will be needed, focusing on these errors, so that we could contribute to the health care of the people by providing precise examinations and high quality medical service.

Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination (노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가)

  • Park, Hyemin;Yoon, Yongsu;Kim, Jungsu;Jeong, Hoiwoun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.

A Study on Establishment of the Optimal Target Exposure Index for Skull Radiography Based on Diagnostic Reference Level (진단참고수준 기반 두부 방사선검사의 최적 목표노출지수 설정에 관한 연구)

  • Park, Hye-Min;Yoon, Yong-Su;Kim, Eun-Hye;Jeong, Hoi-Woun;Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.599-605
    • /
    • 2021
  • The International Electrotechnical Commission (IEC) 62494-1 has defined the exposure index (EI) that have a proportional relationship with the dose incident on the image receptor, and target exposure index (EIT), deviation index (DI). In this study, an appropriate EIT for skull radiography was established through the diagnostic reference level (DRL) and changes in DI were confirmed. Entrance surface dose (ESD) and EI were obtained using the computed radiography system displayed the EI as per IEC on console and skull phantom by experiment based on the national average exposure conditions announced in 2012 and 2019. And appropriate EIT was established by applying the DRL in 2012 and 2019. As a results, the EIT is changed according to the change in the DRL, and the exposure condition that becomes the ideal DI according to the change in the EIT also has a difference of about 1.41 times. DRL is recommended to optimize the patient dose, however it is difficult to measure in real time at medical institutions whereas EI and DI are displayed on the console at the same time as exposure. When the EIT is set based on the DRL and the DI is closed to an ideal value, it is useful as a patient dose management tool. Therefore, when the EIT is periodically managed along with the revision of the DRLs, the patient dose can be optimized through the EI, EIT and DI.

The Role of Neutrophils and Epidermal Growth Factor Receptors in Lipopolysaccharide-Induced Mucus Hypersecretion (리포다당질 (lipopolysaccharide)에 의한 기관지 점액 생성 기전에서 호중구와 상피세포 성장인자 수용체 (epidermal growth factor receptor)의 역할)

  • Bak, Sang Myeon;Park, Soo Yeon;Hur, Gyu Young;Lee, Seung Heon;Kim, Je Hyeong;Lee, Sang Yeub;Shin, Chol;Shim, Jae Jeong;In, Kwang Ho;Kang, Kyung Ho;Yoo, Se Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.1
    • /
    • pp.80-90
    • /
    • 2003
  • Background : Goblet cell hyperplasia is a critical pathological feature in hypersecretory diseases of the airways. A bacterial infection of the lung is also known to induce inflammatory responses, which can lead to the overproduction of mucus. Recently, mucin synthesis in the airways has been reported to be regulated by neutrophilic inflammation-induced epidermal growth factor receptor (EGFR) expression and activation. In addition, it was reported that migration of the activated neutrophils is dependent on the matrix metalloproteinases (MMPs), especially MMP-9. In this study, bacterial lipopolysaccharide (LPS)-induced goblet cell hyperplasia and mucus hypersecretion by EGFR cascade, resulting from the MMPs-dependent neutrophilic inflammation were investigated in the rat airways. Methods : Pathogen-free Sprague-Dawley rats were studied in vivo. Various concentrations of LPS were instilled into the trachea in $300{\mu}{\ell}$ PBS (LPS group). Sterile PBS ($300{\mu}{\ell}$) was instilled into the trachea of the control animals (control group). The airways were examined on different days after instilling LPS. For an examination of the relationship between the LPS-induced goblet cell hyperplasia and MMPs, the animals were pretreated 3 days prior to the LPS instillation and daily thereafter with the matrix metalloproteinase inhibitor (MMPI; 20 mg/Kg/day of CMT-3; Collagenex Pharmaceuticals, USA). The neutrophilic infiltration was quantified as a number in five high power fields (HPF). The alcian blue/periodic acid-Schiff (AB/PAS) stain were performed for the mucus glycoconjugates and the immunohistochemical stains were performed for MUC5AC, EGFR and MMP-9. Their expressions were quantified by an image analysis program and were expressed by the percentage of the total bronchial epithelial area. Results : The instillation of LPS induced AB/PAS and MUC5AC staining in the airway epithelium in a time- and dose-dependent manner. Treatment with the MMPI prevented the LPS-induced goblet cell hyperplasia significantly. The instillation of LPS into the trachea induced also EGFR expression in the airway epithelium. The control airway epithelium contained few leukocytes, but the intratracheal instillation of LPS resulted in a neutrophilic recruitment. A pretreatment with MMPI prevented neutrophilic recruitment, EGFR expression, and goblet cell hyperplasia in the LPS-instilled airway epithelium. Conclusion : Matrix metalloproteinase is involved in LPS-induced mucus hypersecretion, resulting from a neutrophilic inflammation and EGFR cascade. These results suggest a potential therapeutic role of MMPI in the treatment of mucus hypersecretion that were associated with a bacterial infection of the airways.

Performance Evaluation of Aprons according to Lead Equivalent and Form Types (방사선 방어용 앞치마의 납당량, 형태에 따른 성능 평가)

  • Kim, Ki-Won;Choi, Sung-Hyun;Kim, Ki-Yeol;Lee, Ik-Pyo;Hwang, Sun-Gwang;Dong, Kyung-Rae
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.219-225
    • /
    • 2016
  • The apron is one of the essential protectors to reduce the exposure dose of radiological technologists. This study is to provide a guideline for purchasing the aprons with excellent performance and to help reducing the exposure dose by measuring the shielding ration and uniformity of aprons according to lead equivalent and form types. The shielding ratio of aprons were measured by using radiation generator and dosimeter. Exposure conditions were 81 kVp, 25 mAs, source to image receptor distance (SID) 100 cm and field of view (FOV) $17^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$. Exposure areas for front type and around type aprons were divided into 9 areas and for 2 pieces type aprons were divided into 3 areas of top and 4 areas of skirt. The uniformity of aprons were measured by using fluoroscopy and Image J. The 4 regions of interest (ROI) were set into acquired images and measured uniformity by measuring the standard deviation of pixel intensity in ROIs. In continuous shielding ration measurement of aprons according to exposure area, there was not statistical significance (P>0.05). In ANOVA test of aprons, there was statistical significance (P<0.01). In the results of sheilding ratio, although the aprons had equal lead equivalent, there were difference in shielding ratio from 83.59% to 98.15%. In the results of uniformity, the front type aprons with equal lead equivalent indicated the similar uniformity. However, the around type and 2 pieces type apron with equal lead equivalent indicated the different uniformity each other, from 1.8 to 22.2. If the performance evaluation in this study were conducted regularly before and after purchase the aprons, the exposure does to patients and radiological technologists could be reduced.

Effects of Tube Voltage and Tube Current on Exposure Index : Focused on Radiographic Images of Cone Pyramid Phantom (관전압과 관전류량이 노출 지수에 미치는 영향 : 원뿔형 피라미드 팬텀 방사선영상 중심으로)

  • Seoung, You-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.749-755
    • /
    • 2019
  • In this study, we investigated the effects of tube voltage (kVp) and tube current (mAs) on an exposure index (EI) applied to a digital radiography. There used an inverter type digital X-ray generator and an image receptor (IR) utilized a portable wireless detector without a grid. Radiographic images were acquired using a cone pyramid phantom produced using a 3D printer. The X-ray tube voltage was increased from 40 kVp to 120 kVp with 10 kVp increment, and the tube current was increased from 1 mAs to 128 mAs with the twice increment. As a result, kVp had logarithmic relationship with the EI as high $R^2$ value, and mAs had a very high linear relationship too. Also, there was a high correlation between the area dose and the EI of the IR, with the $R^2$ value being 0.76 or more. In conclusion, it had showed that mAs affected the EI linearly, and that it could be advantageous to adjust the easy-to-predict mAs to maintain proper image qualities.

Factors Affecting Breast Cancer Detectability on Digital Breast Tomosynthesis and Two-Dimensional Digital Mammography in Patients with Dense Breasts

  • Soo Hyun Lee;Mi Jung Jang;Sun Mi Kim;Bo La Yun;Jiwon Rim;Jung Min Chang;Bohyoung Kim;Hye Young Choi
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.58-68
    • /
    • 2019
  • Objective: To compare digital breast tomosynthesis (DBT) and conventional full-field digital mammography (FFDM) in the detectability of breast cancers in patients with dense breast tissue, and to determine the influencing factors in the detection of breast cancers using the two techniques. Materials and Methods: Three blinded radiologists independently graded cancer detectability of 300 breast cancers (288 women with dense breasts) on DBT and conventional FFDM images, retrospectively. Hormone status, histologic grade, T stage, and breast cancer subtype were recorded to identify factors affecting cancer detectability. The Wilcoxon signed-rank test was used to compare cancer detectability by DBT and conventional FFDM. Fisher's exact tests were used to determine differences in cancer characteristics between detectability groups. Kruskal-Wallis tests were used to determine whether the detectability score differed according to cancer characteristics. Results: Forty breast cancers (13.3%) were detectable only with DBT; 191 (63.7%) breast cancers were detected with both FFDM and DBT, and 69 (23%) were not detected with either. Cancer detectability scores were significantly higher for DBT than for conventional FFDM (median score, 6; range, 0-6; p < 0.001). The DBT-only cancer group had more invasive lobular-type breast cancers (22.5%) than the other two groups (i.e., cancer detected on both types of image [both-detected group], 5.2%; cancer not detected on either type of image [both-non-detected group], 7.3%), and less detectability of ductal carcinoma in situ (5% vs. 16.8% [both-detected group] vs. 27.5% [both-non-detected group]). Low-grade cancers were more often detected in the DBT-only group than in the both-detected group (22.5% vs. 10%, p = 0.026). Human epidermal growth factor receptor-2 (HER-2)-negative cancers were more often detected in the DBT-only group than in the both-detected group (92.3% vs. 70.5%, p = 0.004). Cancers surrounded by mostly glandular tissue were detected less often in the DBT only group than in the both-non-detected group (10% vs. 31.9%, p = 0.016). DBT cancer detectability scores were significantly associated with cancer type (p = 0.012), histologic grade (p = 0.013), T and N stage (p = 0.001, p = 0.024), proportion of glandular tissue surrounding lesions (p = 0.013), and lesion type (p < 0.001). Conclusion: Invasive lobular, low-grade, or HER-2-negative cancer is more detectable with DBT than with conventional FFDM in patients with dense breasts, but cancers surrounded by mostly glandular tissue might be missed with both techniques.