• Title/Summary/Keyword: Image Quality Measure

Search Result 329, Processing Time 0.027 seconds

The Study on Blast Effects of Stemming Materials by Trauzl Lead Block Test and High Speed 3D-DIC Systems (트라우즐 연주시험 및 고속 3차원 이미지영상상관 기법을 이용한 전색재 별 발파효과에 대한 연구)

  • Ko, Younghun;Seo, Seunghwan;Kim, Sik;Chung, Youngjun;Chung, Moonkyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.10
    • /
    • pp.13-25
    • /
    • 2021
  • The most widely used method for determining the blast effects of explosives is the Trauzl test. This test is used to measure the explosive power (strength) of a substance by determining volume increase, which is produced by the detonation of a tested explosive charge in the cavity of a lead block with defined quality and size. In this paper, Trauzl lead block test and High speed 3D-DIC (Digital Image Correlation) system were conducted to evaluate the stemming effect of the blast hole. The effects of stemming materials can be expressed as the expansion of the cavity in a standard lead block through explosion of the explosives. The blasting experiment was conducted with emulsion explosives. The stemming material in the blast hole of lead block, which was adopted in this study, were using sand and stone chips. Results of blasting experiment and numerical analysis showed that the expansion rates of lead block were most affected by stone chips followed by sand. Also, as result of dynamic strain measurement on the lead block surface of High speed 3D-DIC system, the displacement and surface strain on the block were the highest in the experiment case of stone chips stemming.

D4AR - A 4-DIMENSIONAL AUGMENTED REALITY - MODEL FOR AUTOMATION AND VISUALIZATION OF CONSTRUCTION PROGRESS MONITORING

  • Mani Golparvar-Fard;Feniosky Pena-Mora
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.30-31
    • /
    • 2009
  • Early detection of schedule delay in field construction activities is vital to project management. It provides the opportunity to initiate remedial actions and increases the chance of controlling such overruns or minimizing their impacts. This entails project managers to design, implement, and maintain a systematic approach for progress monitoring to promptly identify, process and communicate discrepancies between actual and as-planned performances as early as possible. Despite importance, systematic implementation of progress monitoring is challenging: (1) Current progress monitoring is time-consuming as it needs extensive as-planned and as-built data collection; (2) The excessive amount of work required to be performed may cause human-errors and reduce the quality of manually collected data and since only an approximate visual inspection is usually performed, makes the collected data subjective; (3) Existing methods of progress monitoring are also non-systematic and may also create a time-lag between the time progress is reported and the time progress is actually accomplished; (4) Progress reports are visually complex, and do not reflect spatial aspects of construction; and (5) Current reporting methods increase the time required to describe and explain progress in coordination meetings and in turn could delay the decision making process. In summary, with current methods, it may be not be easy to understand the progress situation clearly and quickly. To overcome such inefficiencies, this research focuses on exploring application of unsorted daily progress photograph logs - available on any construction site - as well as IFC-based 4D models for progress monitoring. Our approach is based on computing, from the images themselves, the photographer's locations and orientations, along with a sparse 3D geometric representation of the as-built scene using daily progress photographs and superimposition of the reconstructed scene over the as-planned 4D model. Within such an environment, progress photographs are registered in the virtual as-planned environment, allowing a large unstructured collection of daily construction images to be interactively explored. In addition, sparse reconstructed scenes superimposed over 4D models allow site images to be geo-registered with the as-planned components and consequently, a location-based image processing technique to be implemented and progress data to be extracted automatically. The result of progress comparison study between as-planned and as-built performances can subsequently be visualized in the D4AR - 4D Augmented Reality - environment using a traffic light metaphor. In such an environment, project participants would be able to: 1) use the 4D as-planned model as a baseline for progress monitoring, compare it to daily construction photographs and study workspace logistics; 2) interactively and remotely explore registered construction photographs in a 3D environment; 3) analyze registered images and quantify as-built progress; 4) measure discrepancies between as-planned and as-built performances; and 5) visually represent progress discrepancies through superimposition of 4D as-planned models over progress photographs, make control decisions and effectively communicate those with project participants. We present our preliminary results on two ongoing construction projects and discuss implementation, perceived benefits and future potential enhancement of this new technology in construction, in all fronts of automatic data collection, processing and communication.

  • PDF

Performance Evaluation of Reconstruction Algorithms for DMIDR (DMIDR 장치의 재구성 알고리즘 별 성능 평가)

  • Kwak, In-Suk;Lee, Hyuk;Moon, Seung-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose DMIDR(Discovery Molecular Imaging Digital Ready, General Electric Healthcare, USA) is a PET/CT scanner designed to allow application of PSF(Point Spread Function), TOF(Time of Flight) and Q.Clear algorithm. Especially, Q.Clear is a reconstruction algorithm which can overcome the limitation of OSEM(Ordered Subset Expectation Maximization) and reduce the image noise based on voxel unit. The aim of this paper is to evaluate the performance of reconstruction algorithms and optimize the algorithm combination to improve the accurate SUV(Standardized Uptake Value) measurement and lesion detectability. Materials and Methods PET phantom was filled with $^{18}F-FDG$ radioactivity concentration ratio of hot to background was in a ratio of 2:1, 4:1 and 8:1. Scan was performed using the NEMA protocols. Scan data was reconstructed using combination of (1)VPFX(VUE point FX(TOF)), (2)VPHD-S(VUE Point HD+PSF), (3)VPFX-S (TOF+PSF), (4)QCHD-S-400((VUE Point HD+Q.Clear(${\beta}-strength$ 400)+PSF), (5)QCFX-S-400(TOF +Q.Clear(${\beta}-strength$ 400)+PSF), (6)QCHD-S-50(VUE Point HD+Q.Clear(${\beta}-strength$ 50)+PSF) and (7)QCFX-S-50(TOF+Q.Clear(${\beta}-strength$ 50)+PSF). CR(Contrast Recovery) and BV(Background Variability) were compared. Also, SNR(Signal to Noise Ratio) and RC(Recovery Coefficient) of counts and SUV were compared respectively. Results VPFX-S showed the highest CR value in sphere size of 10 and 13 mm, and QCFX-S-50 showed the highest value in spheres greater than 17 mm. In comparison of BV and SNR, QCFX-S-400 and QCHD-S-400 showed good results. The results of SUV measurement were proportional to the H/B ratio. RC for SUV is in inverse proportion to the H/B ratio and QCFX-S-50 showed highest value. In addition, reconstruction algorithm of Q.Clear using 400 of ${\beta}-strength$ showed lower value. Conclusion When higher ${\beta}-strength$ was applied Q.Clear showed better image quality by reducing the noise. On the contrary, lower ${\beta}-strength$ was applied Q.Clear showed that sharpness increase and PVE(Partial Volume Effect) decrease, so it is possible to measure SUV based on high RC comparing to conventional reconstruction conditions. An appropriate choice of these reconstruction algorithm can improve the accuracy and lesion detectability. In this reason, it is necessary to optimize the algorithm parameter according to the purpose.

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

Radiation Dose during Transmission Measurement in Whole Body PET/CT Scan (전신 PET/CT 영상 획득 시 투과 스캔에서의 방사선 선량)

  • Son Hye-Kyung;Lee Sang-Hoon;Nam So-Ra;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.89-95
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation doses during CT transmission scan by changing tube voltage and tube current, and to estimate the radiation dose during our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan. Radiation doses were evaluated for Philips GEMINI 16 slices PET/CT system. Radiation dose was measured with standard CTDI head and body phantoms in a variety of CT tube voltage and tube current. A pencil ionization chamber with an active length of 100 mm and electrometer were used for radiation dose measurement. The measurement is carried out at the free-in-air, at the center, and at the periphery. The averaged absorbed dose was calculated by the weighted CTDI ($CTDI_w=1/3CTDI_{100,c}+2/3CTDI_{100,p}$) and then equivalent dose were calculated with $CTDI_w$. Specific organ dose was measured with our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan using Alderson phantom and TLDs. The TLDs used for measurements were selected for an accuracy of ${\pm}5%$ and calibrated in 10 MeV X-ray radiation field. The organ or tissue was selected by the recommendations of ICRP 60. The radiation dose during CT scan is affected by the tube voltage and the tube current. The effective dose for $^{137}Cs$ transmission scan and high qualify CT scan are 0.14 mSv and 29.49 mSv, respectively. Radiation dose during transmission scan in the PET/CT system can measure using CTDI phantom with ionization chamber and anthropomorphic phantom with TLDs. further study need to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with same image qualify.

  • PDF

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

The Determination of Trust in Franchisor-Franchisee Relationships in China (중국 프랜차이즈 시스템에서의 본부와 가맹점간 신뢰의 영향요인)

  • Shin, Geon-Cheol;Ma, Yaokun
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.2
    • /
    • pp.65-88
    • /
    • 2008
  • Since the implementation of economic reforms in 1978, the Chinese economy grows rapidly at an average annul growth rate of 9% over the post two decades. Franchising has been widely recognized as an important source of entrepreneurial activity. Trust is important in that it facilitates relational exchanges by permits partners to transcend short-run inequities or risks to concentrate on long-term profits or gains. In the relationship between the franchisors and franchisees, trust has been described as an important source of competitive advantage. However, little research has been done on the factors affecting trust in Chinese franchisor-franchisee relationships. The purpose of this study is to investigate what factors affect the trust in the franchise system in China, and to provide guidelines and insights to franchisors which enter Chinese market. In this study, according to Morgan and Hunt (1994), trust is defined as the extending when one party has confidence in an exchange partner's reliability and integrity. We offered a conceptual model of the empirical study. The model shows that the factors affecting the trust include franchisor's supports, communication, satisfaction with previous outcome and conflict. We also suggested the franchisor's supports and communication like to enhance the franchisee's satisfaction with previous outcome, and the franchisor's supports, communication and he franchisee's satisfaction with previous outcome tend to decrease conflict. Before the formal study, a pretest involving exploratory interviews with owners from three franchisees was conducted to make sure the questionnaire was relevant and clear to the respondents. The data were collected using trained interviewers to carry out personal interviews with the aid of an unidentified, muti-page, structured questionnaire. The respondents comprised of owners, managers, and owner managers of franchisee-owned food service franchises located in Beijing, China. Even though a total of 256 potential franchises were initially contacted, the finally usable sample consisted of 125 respondents. As expected, the sampling method was successful in soliciting respondents with waried personal and firm characteristics. Self-administrated questionnaires were used for all measures. And established scales were used to measure the latent constructs in this study. The measures tapped the franchisees' perceptions of the relationship with the referent franchisor. Five-point Likert-type scales ranging from "strongly disagree" (=1) to "strongly agree" (=7) were used throughout the constructs (trust, eight items; support, five items; communication, four items; satisfaction, six items; conflict, three items). The reliability measurements traditionally employed, such as the Cronbach's alpha, were used. All the reliabilities were greater than.80. The proposed measurement model was estimated using SPSS 12.0 and AMOS 5.0 analysis package. We conducted A series of exploratory factor analyses and confirmatory factor analyses to assess the convergent validity, discriminant validity, and reliability. The results indicate reasonable overall fits between the model and the observed data. The overall fit of measurement model were $X^2$= 159.699, p=0.004, d.f. = 116, GFI =.879, NFI =.898, CFI =.969, IFI =.970, TLI =.959, RMR =.058. The results demonstrated that the data reasonably fitted the model. We also examined construct reliability and reliability and average variance extracted (AVE). The construct reliability of each construct was greater than.80 and the AVE of each construct was greater than.50. According to the analysis of Structure Equation Modeling (SEM), the results of path model indicated an adequate fit of the model: $X^2$= 142.126, p = 0.044, d.f. = 115, GFI =.892, NFI =.909, CFI =.981, IFI =.981, TLI =.974, RMR =.057. As hypothesized, the results showed that it is strategically important to establish trust in a franchise system, and the franchisor's supports, communication and satisfaction with previous outcome tend to reinforce franchisee's trust. The results also showed trust seems to decrease as the experience of conflict episodes increases. And we also noticed that franchisor's supports and communication tend to enhance the franchisee's satisfaction with previous outcome, and communication tend to decrease conflict. If the trust between the franchisor and franchisee can be established in a franchise system, franchising offers many benefits and reduces many costs. To manage a mutual trust of relationship with their franchisees, franchisor's should provide support effectively to their franchisees. Effective assistant services have direct effect on franchisees' satisfaction with previous outcome and trust in franchisor. Especially, franchise sales process, orientation, and training in the start-up period are key elements for success of the franchise system. Franchisor's support is an accumulated separate satisfaction evaluation with different kind of service provided by the franchisor. And providing support definitely can improve the trustworthy image of the franchisor. In the franchise system, conflicts of interests and exertions of different power sources are very common. The experience of conflict episodes seems to negatively relate to trust. Therefore, it is important to reduce the negative side of the relationship conflicts. Communication actually plays a broader role in reducing conflict and establish mutual trust in franchisor-franchisee relationship. And effective communication between franchisors and franchisees can improve franchisees' satisfaction toward the franchise system. As the diversification of Chinese markets, both franchisors and franchisees must keep the relevant, timely, and reliable communication. And it is very important to improve the quality of communication. Satisfaction with precious outcomes seems to positively relate to trust. Franchisors and franchisees that are highly satisfied with the previous outcomes that flow from their relationship will perceive their partner as advancing their goal achievement. Therefore, it is necessary for both franchisor and their franchisees to make the welfare of partner with effort. Little literature has focused on what factors affect the trust between franchisors and their franchisees in China. This study developed the hypotheses regarding the factors affecting trust in the transaction relationship. The results of data analysis supported the hypotheses strongly. There are certain limitations in this study. First, we may point out that some other factors missed in this study could be significantly important. Second, the context of this study, food service industry, limits its potential generalizability for all franchise systems. More studies in different categories of franchise system are needed to broaden its generalizability. Third, the model was tested empirically in a sample in Beijing, more empirical tests of the proposed model in other Chinese areas are needed. Finally, the analysis in this study was solely based on the perception of franchisees and the opinions of franchisors were not included.

  • PDF