In this paper, the recirculation flow motion and mixing characteristics driven by air bubble stream in a rectangular water tank is studied. The time-resolved PIV technique is adopted for the quantitative visualization and analysis. 488 nm Ar-ion CW laser is used for illumination and orange fluorescent ($\lambda_{ex}=540nm,\;\lambda_{em}=560nm$) particle images are acquired by a PCO 10bit high-speed CCD camera (1280$\times$1024). To obtain clean particle images, 545 nm long pass optical filter and an image intensifier are employed and the flow rates of compressed air is 3 l/min at 0.5 MPa. The recirculation and mixing flow field is further investigated by time-resolved POD analysis technique. It is observed that the large scale recirculation resulting from the interaction between rising bubble stream and side wall is the most dominant flow structure and there are small scale vortex structures moving along with large scale recirculation flow. It is also verified that the sum of 20 modes of velocity field has about 67.4% of total turbulent energy.
성능이 저하된 IVR 장치의 지속적 사용은 환자 및 시술자의 방사선 피폭을 증가시킬 뿐 아니라, 잘못된 영상정보를 제공함으로써 환자에게 심각한 영향을 끼칠 수 있다. 따라서 이번 연구에서는 IVR장치의 성능평가를 위한 적절한 시험방법 및 검사기준을 마련하고자 하였다. IVR장치의 국내현황 및 규격을 조사하였으며, 표준팬텀을 이용하여 국내 IVR장치의 성능을 현장 측정함으로써, 국내 실정에 맞는 적절한 IVR 장치의 화질 및 성능평가 기준을 설정하였다. 장치의 기본적 성능에 관한 검사를 위해 관전압시험, 관전류 시험, 반가층 시험을 실시하며, NEMA stndard XR-21 Phantom을 표준팬텀으로 사용하여 화질 및 선량 평가를 하도록 하였다. 표준팬텀을 이용한 검사항목은 image-field geometry, spatial resolution, low-contrast iodine detectability, wire resolution, phantom entrance dose이다. 또한 매일, 매주, 1개월, 3개월, 6개월 및 1년 주기의 평가항목을 설정하였다. 장치의 성능기준은 진단용방사선안전관리 규정을 준용하여 kVp시험은 평균오차 ${\pm}10%$, mA시험은 평균오차 ${\pm}15%$, 반가층시험은 80kVp에서 최소 2.3mmAl으로 설정하였다. 표준팬텀의 검사기준은 image-field geometry에서 최소 acceptable이 나와야 하며, spatial resolution은 Image Intensifier 나 detector 크기기준으로 34-40cm은 0.8 lp/mm, 28-33cm은 1.0lp/mm, 22-27cm은 1.2 lp/mm이상이 나와야 한다. low contrast iodine detectability는 최소농도 200mg/cc 이상 보여야 하며, phantom entrance dose는 10R/min을 초과해서는 안 된다. Wire resolution은 정지 상태에서 최소 0.012인치까지 보여야 하며, 움직일 때 최소 0.022인치까지 보여야 한다.
현재 임상에서 사용중인 국산 30 kHz 용량의 PWM방식의 인버터식 X선 장치의 성능을 장치의 출력정확도, 출력파형의 변화 및 영상증배관의 변환계수 등을 평가하여 그 유용성을 알아보았다. 그 결과 촬영용 장치의 관전류, 관전압, 단시간 특성은 KS규정에 대해 매우 양호한 정확도를 유지했고 출력파형도 양호한 특성을 나타내었다. 또한 촬영시 X선 장치의 출력은 단상대비 약 1.7배 정도 많게 나타났다. 투시장치의 성능에서도 관전류, 관전압 및 sopt촬영 관전류, 관전압 모두 최고 5.8% 이하의 양호한 결과를 나타내었으며, 영상증배관의 변환계수는 2년여 사용한 것을 고려할 때 75kV에서 310으로 상당히 높았다. 국내기술로 개발된 고주파식 X선 장치가 성능의 실용적 단계를 넘는 것으로 나타나 앞으로 고주파식 X선 장치가 국내, 외에 많이 보급되고 이용될 것으로 사료된다.
Purpose: The purpose of this study is to analyze the measurement differences of simple radiographs according to radiation projection angle using a phantom and to propose methods for objective analysis of simple radiographs. Materials and Methods: We took simple radiographs with different projection angles using a C-arm image intensifier and measured five parameters of the foot on the simple radiographic images. Five parameters include lateral tibiocalcaneal angle, lateral talocalcaneal angle, naviculocuboid overlap, lateral talo-first metatarsal angle, and lateral calcaneo-first metatarsal angle. Intraobserver and interobserver reliability were verified, and then intraclass correlations of parameters were analyzed. Results: Radiographic parameters of the foot showed high intraobserver and interobserver reliability. Lateral tibiocalcaneal angle has a strong negative linear relationship with rotation and a moderate negative linear relationship with tilt. Lateral talocalcaneal angle has a moderate positive linear relationship with rotation and a strong positive linear relationship with tilt. Naviculocuboid overlap has a strong positive linear relationship with rotation and a moderate positive linear relationship with tilt. Lateral talo-first metatarsal angle does not have a linear relationship with rotation and a moderate negative linear relationship with tilt. Lateral calcaneo-first metatarsal angle has a moderate positive linear relationship with rotation and tilt. Conclusion: More precise evaluation of the foot with a simple radiograph can be performed by understanding the changes of radiographic parameters according to radiation projection angle.
본 연구의 목적은 디지털 혈관 조영 촬영장치를 이용한 검사 시 X선관, 환자 테이블, 검출기 또는 환자 등의 기하학적 특성에 따라 실무자가 수시로 변화시켜 적용할 수 있는 매개변수에 대해 알아보고 이에 따른 환자 및 의료진의 방사선 피폭선량을 감소시키는 방안에 대해 알아보고자 하였다. 기하학적 특성들에 따라 각각 fluoroscopy mode와 Digital subtraction angiography로 촬영하고 유효 선량으로 환산한 값을 비교하였다. 연구결과 FPS mode에 따른 선량은 FPS mode를 낮게 설정할수록 선량이 30-40%까지 감소하였다. X선관 각도에 따른 선량은 AP View에서 가장 높게 측정되었고 머리 방향으로 각도가 들어갈수록 선량이 낮게 측정되었다. FOV가 확대될수록 선량이 1.2-1.6배 증가하였고 X선관과 테이블의 거리가 가까워질수록 약 10% 증가하였다. X선관과 평판형 검출기의 거리가 100 mm 멀어질수록 선량이 20-30% 증가하였다. 결론적으로 혈관 조영검사 시 다양한 기하학적 특성들은 실무자가 수시로 변화시켜 적용할 수 있는 매개변수이며 다양한 상황에서 적합한 기하학적 특성들을 고려하여 적용함으로써 적절한 선량 감소 효과를 기대할 수 있다.
Background: The common causes of lower back pain with or without leg pain includes disk disease and spinal stenosis. A definitive diagnosis is usually made by means of magnetic resonance imaging (MRI), but treatment is often difficult because the MRI findings are not consistent with the symptoms of the patient in many cases. The objective of this study was to observe the correlation between the patterns of epidurography performed in patients having lower back pain with or without leg pain and the position or severity of the pain as subjectively described by the patients. Methods: The subjects of this study were 69 outpatients with lower back pain with or without leg pain who visited our clinic and complained of predominant pain on one side. We performed caudal epidural block using an image intensifier. A mixture of the therapeutic drug and the contrast agent (10 ml) was injected to observe the contrast flow pattern. The patients who complained of predominant pain on one side were divided into the left side group and the right side group. A judgment of inconsistency was made if the contrast agent flowed to the side of the pain, while a judgment of consistency was made if the contrast agent flowed to the opposite side of the pain. The degree of the drug distribution was evaluated by counting the number of cells to which the contrast agent's flowed for evaluating the correlation between the contrasted cell and the severity of pain (one group ${\leq}$ VAS 7, the other group ${\geq}$ VAS 8) the degree of the contrast agent's contrast was evaluated by dividing and counting an image into 15 cells (the left, right, and middle sections at each level of L4, L5, S1, S2, and S3). Results: Thirty out of the 69 patients who had laterality in pain, that is, those who complained of predominant pain on one side, showed that the laterality of the pain and the contrast agent flow was consistent, while 39 patients showed that the laterality was inconsistent (P: 0.137). The evaluation of the correlation between the pain and the contrast agent flow showed that the mean number of contrasted cells was $9.0{\pm}2.2$ for the 46 patients in the group with a VAS of 7 or lower and $6.5{\pm}2.0$ for the 23 patients in the group with a VAS of 8 or higher, indicating that the former group showed a significantly greater number of contrasted cells (P < 0.001). Conclusions: This study, conducted with patients having lower back pain with or without leg pain, showed that the contrast flow pattern of caudal epidurography had a significant correlation with the severity of the pain but not with the laterality of the pain.
Purpose: To analyze the result of the accurate open reduction of acromioclavicular (AC) joint and pin fixation, coracoclavicular (CC) screw fixation without CC ligament repair for AC joint injuries. Materials and Methods: Between January 2000 and December 2003, seventeen cases with at least one year follow-up among twenty-one cases underwent operation for AC-CC ligament injuries. A transverse incision approximately 5 cm in length was made over the clavicle, and the AC joint was reduced accurately. Under the image intensifier, a cannulated screw and washer were inserted for the CC ligament. Two Steinman pins were inserted for the AC joint and the AC ligament was repaired with nonabsorbable suture. Gentle passive range of motion was begun postoperative 2 weeks. The pins were removed at $6{\sim}8$ weeks and the screw was removed at $10{\sim}12$ weeks. The results were evaluated by a distance between AC and CC joints on plain films and ASES score at last follow-up. Results: At the last follow-up, there was no limitation of motion and average ASES score was 96($86{\sim}100$ points). There was no failure showing over 5 mm difference of distance compared to opposite side on the plain films. Seven cases had the skin damages and local infection due to pin migration and three cases showed the loosening of CC screw. Conclusion: We could have satisfactory results by accurate reduction of AC joint and simple pins and screw fixation for AC-CC ligament injuries.
본 영남대학교 의과대학 부속병원 정형외과에서는 1986년 12월에서 1991년 11월까지 경부 간부 골절 31례에 대하여 Ender nail을 시행하여 다음과 같은 결과를 얻었다. 1. 환자의 평균연령은 37.3세였고, 남자에게서 3배가 많았으며, 교통사고가 가장 많은 원인이었다(67%). 2. 폐쇄성 골절이 20례, 개방성 골절이 11례였으며, 분쇄골절과 분절골절이 18례(57.7%)였고, 중간부 골절이 16례로 가장 많았다. 3. 동반손상이 19례에서 있었고, 수상후 수술까지의 기간은 평균 7.6일이었다. 4. 평균 골유합 기간은 18.9주였으며, 2례에서 지연유합을 보였다. 5. 합병증으로 하지 단축이 2례, 각형성 변형이 3례, 관절 운동 제한 2례, 감염이 연부조직에 1례 있었다. 이상 경골 간부골절 치료에 사용한 Ender nail은 시술의 간편성, 적절한 고정성과 운동성, 비교적 폭넓은 적용 범위등으로 좋은 치료 결과를 기대할 수 있는 방법으로 사료된다.
목적: 경골과 골절과 동반된 외측 반월상 연골 손상에서 봉합술 및 부분 절제술 후 치료 결과를 분석 하고자 하였다. 대상 및 방법: 1953년 2월부터 2004년 8월까지 경골과 골절로 치료 한 23명, 24예의 외측 반월상 연골 파열을 대상으로 하였다. 파열의 형태는 반월상 연골-관절낭 경계부의 종 파열 (14예, 66.7%)이 가장 많았다. 모든 골절은 관절경과 영상 증폭기의 감시하에 정복을 하였으며 반월상 연골 종 파열은 관절경하 수직 봉합술을, 나머지는 부분 절제술로 치료 하였다. 임상적 결과를 Ikeuchi의 평가 기준에 따라 분류하고 수술 전과 후의 Lysholm 점수를 비교 하였다(paired t-test). 결과: Ikeuchi 평가 기준에 따른 결과는 봉합술을 시행한 14예중 우수 12예 (85.7%), 양호 12예 (7.1%), 보통1예 (7.1%)였으며, 부분 절제술을 시행한 6예 중 우수는 4예 (66.7%), 양호는 2예(33.3%)를 보였다. Lysholm 점수는 수술 전 평균 56.6점에서 수술 후 92.3점으로 증가 하였다(p<0.0001, paired t-test). 결론: 경골과 골절은 외측 반월상 연골의 봉합술이나 부분 제거술의 결과에 나쁜 영향을 끼치지 않는 것으로 사료된다.
목적 : 선형가속기를 이용한 방사선 치료시 치료부위의 확인을 위한 하나의 방법으로 port film이 사용되고 있다 서울대학병원에서는 port film 촬영 시 기계적 변수를 port film상에 나타내기 위하여 방향성 표시기(orientation marker)를 갖는 fiduciary plate를 개발하였다. 대상 및 방법 : Fiduciary plate의 제작에는 아크릴 plate와 cerrobend, 수은이 사용되었다. 아크릴 plate의 크기는 $1\;cm{\times}25\;cm{\times}25\;cm$로 그 내부에 두 개의 방향성 표시기가 내재되었고, 선형가속기의 blocking tray slot에 삽입이 가능하도록 제작되었다. Plate 내부에는 2 cm 간격으로 2 mm 두께의 수평과 수직으로 만들어진 cerrobend line이 위치해 있고, 방향성 표시기 내부에는 수은으로 채워져 있다. 결과 : 아크릴 plate의 cerrobend line은 simulation films과 port films간의 치료 영역의 비교를 용이하게 한다. 수은을 이용하여 만들어진 방향성 표시기는 납으로 만들어진 일반적인 표시기가 없이도 전후좌우와 다양한 각도로 경사진 방향을 구분할 수 있게 한다. 또한 방향성 표시기는 film/cassette holder에 부착함으로써 simulation 시에도 이용될 수 있다. 결론: Fiduciary plate는 치료 영역 확인에 유용하고, 수은을 이용한 방향성 표시기내의 혼합액의 기하학적인 모양에 따라 port film의 촬영 parameter를 용이하게 파악할 수 있어 치료과정에서 촬영한 port film 간의 임상정도관리에 유용한 방법이 될 수 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.