• Title/Summary/Keyword: Image Compensation

Search Result 586, Processing Time 0.021 seconds

Design of an Endoscopic Microscope Objective Lens Composed of Flexible Fiber Bundle and Gradient-index with a High Resolution and a Minimally-Invasive Outer Diameter (광섬유 다발과 Gradient-index Lens가 결합된 고 분해능 및 최소침습 직경의 공초점 내시 현미경 대물렌즈의 설계)

  • Jang, Sun-Young;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.87-94
    • /
    • 2008
  • We present a new design for an endoscope objective lens composed of a lexible fiber bundle with 30,000 core, and a gradient-index (GRIN) objective lens with an optical adaptor. The characteristic of this objective lens is to be minimally-invasive to be able to insert easily in the internal organs of live animals. The GRIN lens has a small diameter and a very simple construction, which is selected with the diameter of 1.0 mm and numerical aperture of 0.5 to achieve a minimally-invasive outer diameter and a high resolution. The resultant designed lens shows the performance as follows; a lateral resolution of 1.63 um and diameters of 100% encircled energy of $0.3\;{\mu}m$ and $0.83\;{\mu}m$ for the on-axis and the off-axis image point, respectively. Also, we can present a cheap solution with a lateral resolution of 1.74 um and diameters of 100% encircled energy of $1.10\;{\mu}m$ and $2.84\;{\mu}m$ for the on-axis and the off-axis image point, respectively.

Effect of Calcium Chloride (CaCl2) on the Characteristics of Photosynthetic Apparatus, Stomatal Conductance, and Fluorescence Image of the Leaves of Cornus kousa (염화칼슘 처리가 산딸나무 잎의 광합성 기구, 기공전도도 및 형광이미지 특성에 미치는 영향)

  • Sung, Joo-Han;Je, Sun-Mi;Kim, Sun-Hee;Kim, Young-Kul
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.4
    • /
    • pp.143-150
    • /
    • 2009
  • Deicing salt is used to melt snow and ice on the road for traffic safety during the winter season, which accumulates in the roadside vegetation and induces visible injuries. The damage may accelerate particularly when it coincides with early spring leaf out. In order to better understand the response mechanisms, C. kousa (3-year-old) was irrigated twice prior to leaf bud in a rhizosphere with solutions of 0.5, 1.0, and 3.0% calcium chloride ($CaCl_2$) concentration, that were made by using an industrial $CaCl_2$ reagent practical deicing material in Seoul. Physiological traits of the mature leaves were progressively reduced by $CaCl_2$ treatment, resulting in reductions of total chlorophyll contents, chlorophyll a:b, photosynthetic rate, quantum yield, stomatal conductance, $F_V/F_M$, and NPQ. On the contrary, light compensation point and dark respiration were increased at high $CaCl_2$ concentration. A decrease in intercellular $CO_2$ concentration by stomatal closure first resulted in a reduced photosynthetic rate and then was accompanied by low substance metabolic rates and photochemical damage. Based on the reduction of physiological activities at all treatments ($CaCl_2$ 0.5%, 1.0%, and 3.0%), C. kousa was determined as one of the sensitive species to $CaCl_2$.

Analysis of Applicability of RPC Correction Using Deep Learning-Based Edge Information Algorithm (딥러닝 기반 윤곽정보 추출자를 활용한 RPC 보정 기술 적용성 분석)

  • Jaewon Hur;Changhui Lee;Doochun Seo;Jaehong Oh;Changno Lee;Youkyung Han
    • Korean Journal of Remote Sensing
    • /
    • v.40 no.4
    • /
    • pp.387-396
    • /
    • 2024
  • Most very high-resolution (VHR) satellite images provide rational polynomial coefficients (RPC) data to facilitate the transformation between ground coordinates and image coordinates. However, initial RPC often contains geometric errors, necessitating correction through matching with ground control points (GCPs). A GCP chip is a small image patch extracted from an orthorectified image together with height information of the center point, which can be directly used for geometric correction. Many studies have focused on area-based matching methods to accurately align GCP chips with VHR satellite images. In cases with seasonal differences or changed areas, edge-based algorithms are often used for matching due to the difficulty of relying solely on pixel values. However, traditional edge extraction algorithms,such as canny edge detectors, require appropriate threshold settings tailored to the spectral characteristics of satellite images. Therefore, this study utilizes deep learning-based edge information that is insensitive to the regional characteristics of satellite images for matching. Specifically,we use a pretrained pixel difference network (PiDiNet) to generate the edge maps for both satellite images and GCP chips. These edge maps are then used as input for normalized cross-correlation (NCC) and relative edge cross-correlation (RECC) to identify the peak points with the highest correlation between the two edge maps. To remove mismatched pairs and thus obtain the bias-compensated RPC, we iteratively apply the data snooping. Finally, we compare the results qualitatively and quantitatively with those obtained from traditional NCC and RECC methods. The PiDiNet network approach achieved high matching accuracy with root mean square error (RMSE) values ranging from 0.3 to 0.9 pixels. However, the PiDiNet-generated edges were thicker compared to those from the canny method, leading to slightly lower registration accuracy in some images. Nevertheless, PiDiNet consistently produced characteristic edge information, allowing for successful matching even in challenging regions. This study demonstrates that improving the robustness of edge-based registration methods can facilitate effective registration across diverse regions.

A Study on Compensation for Imaging Qualities Having Artifact with the Change of the Center Frequency Adjustment and Transmission Gain Values at 1.5 Tesla MRI (1.5 Tesla 기기에서 중심주파수 조정과 송 신호강도(Transmission Gain)값 변화에 따른 인공물이 있는 자기공명영상의 질 보상에 관한 연구)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Han-Joo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.244-252
    • /
    • 2009
  • The purpose of this study is to compensate for susceptibility and a ferromagnetic body artifact using CFA and TGV on MR Imaging. A total of 30 patients (15 men and 15 women, mean age: 45 years) were performed on head and neck diseases. MR Unit used a 1.5T superconducting magnet (GE medical system, High Density). This study have investigated by changing with CFA and TGV (70, 90, 110, 130, 150) searching for compensation values about susceptibility and a ferromagnetic body artifact in 60 kg standards of body weight (p<0.05). As a quality results, Image qualities were obtained at different score from CFA and TGV (70, 90, 110, 130, $150=3.23{\pm}0.35$, $4.31{\pm}0.02$ $4.23{\pm}0.21$, $5.12{\pm}0.25$, $7.13{\pm}0.72$, $8.31{\pm}0.01$, $5.21{\pm}0.15$, $6.14{\pm}0.08$, $5.23{\pm}0.72$, $5.91{\pm}0.06$, p<0.05). Absolute CNRs (TG, CNRpre, CNRpost) were acquired with (70:$-1.44{\pm}0.11$, $-2.7{\pm}0.04$, 90:$-2.18{\pm}0.42$, $-4.41{\pm}0.43$, 110:$-2.89{\pm}0.43$, $-5.23{\pm}0.02$, 130:$-2.34{\pm}0.05$, $-5.26{\pm}0.01$, 150: $-2.09{\pm}0.08$, $-3.87{\pm}0.12$, p<0.05). In conclusions, this study could be compensated for metal and flow artifacts surrounding the tissues having artifact by changing CFA and TGV.

  • PDF

New Prefiltering Methods based on a Histogram Matching to Compensate Luminance and Chrominance Mismatch for Multi-view Video (다시점 비디오의 휘도 및 색차 성분 불일치 보상을 위한 히스토그램 매칭 기반의 전처리 기법)

  • Lee, Dong-Seok;Yoo, Ji-Sang
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.6
    • /
    • pp.127-136
    • /
    • 2010
  • In multi-view video, illumination disharmony between neighboring views can occur on account of different location of each camera and imperfect camera calibration, and so on. Such discrepancy can be the cause of the performance decrease of multi-view video coding by mismatch of inter-view prediction which refer to the pictures obtained from the neighboring views at the same time. In this paper, we propose an efficient histogram-based prefiltering algorithm to compensate mismatches between the luminance and chrominance components in multi-view video for improving its coding efficiency. To compensate illumination variation efficiently, all camera frames of a multi-view sequence are adjusted to a predefined reference through the histogram matching. A Cosited filter that is used for chroma subsampling in many video encoding schemes is applied to each color component prior to histogram matching to improve its performance. The histogram matching is carried out in the RGB color space after color space converting from YCbCr color space. The effective color conversion skill that has respect to direction of edge and range of pixel value in an image is employed in the process. Experimental results show that the compression ratio for the proposed algorithm is improved comparing with other methods.

Spontaneous bone regeneration after surgical extraction of a horizontally impacted mandibular third molar: a retrospective panoramic radiograph analysis

  • Kim, Eugene;Eo, Mi Young;Nguyen, Truc Thi Hoang;Yang, Hoon Joo;Myoung, Hoon;Kim, Soung Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.4.1-4.10
    • /
    • 2019
  • Background: The mandibular third molar (M3) is typically the last permanent tooth to erupt because of insufficient space and thick soft tissues covering its surface. Problems such as alveolar bone loss, development of a periodontal pocket, exposure of cementum, gingival recession, and dental caries can be found in the adjacent second molars (M2) following M3 extraction. The specific aims of the study were to assess the amount and rate of bone regeneration on the distal surface of M2 and to evaluate the aspects of bone regeneration in terms of varying degree of impaction. Methods: Four series of panoramic radiographic images were obtained from the selected cases, including images from the first visit, immediately after extraction, 6 weeks, and 6 months after extraction. ImageJ software® (NIH, USA) was used to measure linear distance from the region of interest to the distal root of the adjacent M2. Radiographic infrabony defect (RID) values were calculated from the measured radiographic bone height and cementoenamel junction with distortion compensation. Repeated measures of analysis of variance and one-way analysis of variance were conducted to analyze the statistical significant difference between RID and time, and a Spearman correlation test was conducted to assess the relationship between Pederson's difficulty index (DI) and RID. Results: A large RID (> 6 mm) can be reduced gradually and consistently over time. More than half of the samples recovered nearly to their normal healthy condition (RID ≤ 3 mm) by the 6-month follow-up. DI affected the first 6 weeks of post-extraction period and only showed a significant positive correlation with respect to the difference between baseline and final RID. Conclusions: Additional treatments on M2 for a minimum of 6 months after an M3 extraction could be recommended. Although DI may affect bone regeneration during the early healing period, further study is required to elucidate any possible factors associated with the healing process. The DI does not cause any long-term adverse effects on bone regeneration after surgical extraction.

Developing a Portable Intelligent Projection System (휴대형 지능형 프로젝션 시스템 개발)

  • Park, Han-Hoon;Seo, Byung-Kuk;Jin, Yoon-Jong;Oh, Ji-Hyun;Park, Jong-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.26-34
    • /
    • 2007
  • Intelligent projection system indicates a system that displays desired images on an arbitrary screen in an arbitrary environment using projector without noticeable image distortion. In recent years, projectors have become widespread and ubiquitous due to their increasing capabilities and declining cost. Moreover, the size of projectors is getting smaller and handhold projectors are emerging. Thanks to these advances, the demand for intelligent projection system has been significantly increased and the demand has led to remarkable progress of the related techniques or technologies to intelligent projection system However, there are still some environments (or conditions, mainly dynamic ones) that intelligent projections systems cannot handle and they have limited the application area of intelligent projection systems. This paper exemplifies such environments (e.g. specular screen, dynamic screen) and propose effective solutions (i.e. multiple overlapping projectors, complementary pattern embedding) for thor And the usefulness of the solutions is verified through experimental results and user evaluation. Notice that the environments are considered not simultaneously but independently because it is impossible to consider them simultaneously by simply combining the solutions for each. Acually, a totally different solution would be necessary to consider them simultaneously. Therefore, we expect that the proposed methods would largely extend the application area of intelligent projection systems except for severely arbitrary environment.

B-site Cationic Ordering Structures of Donor-Doped Relaxor Ferroelectric $Pb({Mg_{1/3}}{Nb_{2/3})}O_3$ (전자 주게가 첨가된 완화형 강유전체 $Pb({Mg_{1/3}}{Nb_{2/3})}O_2$의 B자리 양이온 질서배열구조)

  • Cha, Seok-Bae;Kim, Byeong-Guk;Je, Hae-Jun
    • Korean Journal of Materials Research
    • /
    • v.10 no.7
    • /
    • pp.478-481
    • /
    • 2000
  • Single phase $Pb(Mg_{1/3}Nb_{2/3})O_3$ ceramics doped by 10 mol% of electron donors such as $La^3,\; Pr^{3+,4+},\; Nd^{3+},\; Sm^{3+}$, were synthesized and their B-site cationic ordering structures were investigated by XRD and TEM. In the XRD patterns, only fundamental reflections were observed for the undoped $Pb(Mg_{1/3}Nb_{2/3})O_3$, while the (h/2 $\textsc{k}$/2ι/2)(h,$\textsc{k}$,ι all odd) superlattice reflections resulting from the 1:1 ordering induced unit cell doubling were also observed for the donor-doped $Pb(Mg_{1/3}Nb_{2/3})O_3$. In the TEM selected area diffraction patterns, the (h/2 k/2 l/2)(h,k,l all odd) superlattice reflection spots as well as the fundamental reflection spots were observed for all the samples, but the relative intensities of the superlattice reflection spots to the fundamental reflection spots were significantly enhanced by the donor-doping. In the TEM dark-field images, antiphase boundaries were observed only for the donor-doped $Pb(Mg_{1/3}Nb_{2/3})O_3$. It was therefore experimentally verified that doping by electron donors such as $La^3,\; Pr^{3+,4+},\; Nd^{3+},\; Sm^{3+}$, enhances the B-site cationic 1:1 ordering in $Pb(Mg_{1/3}Nb_{2/3})O_3$. These experimental results were interpreted in terms of the charge compensation mechanism.

  • PDF

A Study on the Health Status of Korean Vietnam Veterans' Children - A Result of Questionnaire Survey on Vietnam Veterans of Pusan Area Who Diagnosed as Cases by Korean Veteran's Hospital Diagnostic Criteria - (베트남전 참전자 2세의 건강상태에 관한 조사 - 부산지역 고엽제 위해증 환자를 대상으로 한 설문조사 결과 -)

  • Kim, Hak-Joon;Sohn, Hae-Sook;Urm, Sang-Hwa;Park, Soo-Kyung;Yu, Byung-Chul;Lee, Jong-Tae;Chun, Jin-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.1
    • /
    • pp.17-24
    • /
    • 2000
  • Objectives : To propose the referential data to evaluate the health impacts of Vietnam veterans' children whose father were exposed to herbicides in Vietnam War. Methods : Vietnam veterans who visited to Pusan Veteran Hospital for medical care were recruited from April to October, 1998. They were 71 and asked about their own combat history, symptoms and illness, and health status of their 182 children. The informations were collected by direct and phone interview. Exposure estimation was also performed as exposure score depending on year and unit of participation, and personal episodes related to exposure to herbicide in the war. It classified into three groups; lower(<18.0), moderate(18-53), high$(\geq53)$ exposure group. Results : The mean age and the period into the combat of the veterans were 52.8 years and 15.0 months. The mean exposure score was $18.1{\pm}9.9$, and mainly distributed in lower (46.5%) and moderate(52.1%) exposure group. Most(90.1%) of them were diagnosed as sequelae(21 cases) and suspected sequelae(43 cases) of the herbicides by Korean veteran's hospital diagnostic criteria. The major sequelae was peripheral neuropathy 13 cases, chloracne 5 cases, and the major suspected sequelae was hypertension 20 cases, diabetes mellitus 18 cases, liver disease 12 cases, central neuropathy 11 cases, etc. About birth, 42.2% and 16.9% experienced spontaneous abortion and stillbirth, respectively. The mean exposure score was higher in stillbirth experience group(p<0.05). About half of the children(90 cases, 49.5%) hold the abnormal health status: those were skin pigmentation 38 cases, rash 23 cases, congenital anomaly 15 cases, general weakness 12 cases, purpura 8 cases, visual disturbance 8 cases, etc. These health problems had no association with father's exposure level(p>0.05). Conclusions : These results were depend on their own answers, and expectation for compensation did not excluded, therefore, this study may have limitations: inaccuracy of informations due to recall bias and response bias. Nevertheless, through this study, we could image the fundamental aspect for health impacts of Vietnam veterans' children for preparing the national control program and policy. A large scale epidemiologic study with valid exposure assessment on the health impacts of Vietnam veterans' children is recommneded.

  • PDF

Research and development on image luminance meter of road tunnel internal and external (도로터널 내/외부의 영상휘도 측정기 연구개발)

  • Jang, Soon-Chul;Park, Sung-Lim;Ko, Seok-Yong;Lee, Mi-Ae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • This paper introduces the development of imaging luminance meter which measures the luminances of external/internal road tunnel. The developed imaging luminance meter complies with both L20 method and Veiling luminance method of the international standards, CIE88. In this paper the L20 method is mainly presented because most of tunnels currently adapt L20 method. The developed system has an embedded computer to operate at stand-alone. The system has a ethernet port, a heater, a fan, a defroster, a wiper and sun shielder. Compensation algorithm is applied for correcting non-linear responses to the luminance and integration time. The accuracy of measurement is less than 1% when it calibrated at the public certification institute. The developed system was also tested at the real field, road tunnel. The test results were very similar with the reference luminance meter and showed that the developed system operates well at the real field. Partial sensor saturations were happened to show the less luminance, because there were the high reflecting objects in the real field. Further study should be followed for high luminance measurement.