• Title/Summary/Keyword: Image Artifact removal

Search Result 18, Processing Time 0.02 seconds

Simple image artifact removal technique for more accurate iris diagnosis

  • Kim, Jeong-lae;Kim, Soon Bae;Jung, Hae Ri;Lee, Woo-cheol;Jeong, Hyun-Woo
    • International journal of advanced smart convergence
    • /
    • v.7 no.4
    • /
    • pp.169-173
    • /
    • 2018
  • Iris diagnosis based on the color and texture information is one of a novel approach which can represent the current state of a certain organ inside body or the health condition of a person. In analysis of the iris images, there are critical image artifacts which can prevent of use interpretation of the iris textures on images. Here, we developed the iris diagnosis system based on a hand-held typed imaging probe which consists of a single camera sensor module with 8M pixels, two pairs of 400~700 nm LED, and a guide beam. Two original images with different light noise pattern were successively acquired in turns, and the light noise-free image was finally reconstructed and demonstrated by the proposed artifact removal approach.

Noise removal or video sequences with ,3-D anisotropic diffusion equation (3차원 이방성확산 방정식을 이용한 동영상의 영상잡음제거)

  • Lee, Seok-Ho;Choe, Eun-Cheol;Gang, Mun-Gi
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.2
    • /
    • pp.79-86
    • /
    • 2002
  • Nowadays there is a trend to apply the diffusion equation to image Processing. The anisotropic diffusion equation is highly favoured as a noise removal algorithm because it can remove noise while enhancing edges. However if the two dimensional anisotropic diffusion equation is applied to the noise removal of video sequences, flickering artifact due to the luminance difference between frames and ghost artifact due to the interfiltering between frames occur. In this paper the two dimensional anisotropic diffusion equation is extended to the sequence axis. The Proposed three dimensional anisotropic diffusion equation removes noise more efficiently than the two dimensional equation, and furthermore removes the flickering and ghost artifact as well.

The Removal of Trembling Artifacts for FORMOSAT-2

  • Chang Li-Hsueh;Wu Shun-Chi;Cheng Hsin-Huei;Chen Nai-Yu
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.142-145
    • /
    • 2005
  • Since the successful launch of FORMOSAT -2 satellite by National Space Organization of Taiwan in May 2004, the Remote Sensing Instrument (RSI) on- board the FORMOSAT -2 has continuously acquired images at one panchromatic and four multi-spectral bands (http://www.nspo.org.tw). In general, the RSI performs well and receives high quality images which proved to be very useful for various applications. However, some RSI panchromatic products exhibit obvious trembling artifact that must be removed. Preliminary study reveals that the trembling artifact is caused by the instability of the spacecraft attitude. Though the magnitude of this artifact is actually less than half of a pixel, it affects the applicability of panchromatic products. A procedure removing this artifact is therefore needed for providing image products of consistent quality. Due to the nature of trembling artifact, it is impossible to describe the trembling amount by employing an analytic model. Relied only on image itself, an algorithm determining trembling amount and removing accordingly the trembling artifact is proposed. The algorithm consists of 3 stages. First, a cross-correlation based scheme is used to measure the relative shift between adjacent scan lines. Follows, the trembling amount is estimated from the measured value. For this purpose, the Fourier transform is utilized to characterize random shifts in frequency domain. An adaptive estimation method is then applied to deduce the approximate trembling amount. In the subsequent stage, image re-sampling operation is applied to restore the trembling-free product. Experimental results show that by applying the proposed algorithm, the unpleasant trembling artifact is no longer evident.

  • PDF

Removal of Ring Artifact in Computed Tomography (전산화단층촬영장치에서 링 아티팩트 제거)

  • Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.403-408
    • /
    • 2015
  • Hard X-ray has been widely used in medical and industrial fields because it can be applied to observe the inside of a sample. Computed tomography provides sectional images of the sample through the reconstruction of the projection images. The quality of sectional images strongly depends on that of projection images. Ring artifact appeared on the seconal image can be made by the abnormal pixels of the detector used. In this study, we examine the ring artifact ratio in the circle phantom as a function of detection error of the detector used in computed tomography. The ring artifact increased with the increment of detection error under parallel and fan beam geometries and strongly increased near the center of rotation. The corrections, dead pixel and flat field corrections, for the images taken with the detector are required before the image reconstruction process to reduce the ring artifact in the computed tomography.

Ringing Artifact Removal in Image Restoration Using Wavelet Transform (웨이블릿 변환을 이용한 영상복원의 물결현상 제거 방법)

  • Youn, Jin-Young;Yoo, Yoon-Jong;Jun, Sin-Young;Shin, Jeong-Ho;Paik, Joon-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.6
    • /
    • pp.78-87
    • /
    • 2008
  • Digital image find own level core media in multimedia as image restoration technology fields, which remove degradation factor for image enhancement, have been growing. Linear space-invariant image restoration algorithm often introduce ringing artifacts near sharp intensity transition areas. This paper presents a new adaptive post-filtering algorithm for reducing ringing artifact. The proposed method extracts an edge map of the image using wavelet transform Based on the edge information, ringing artifacts are detected, and removed by an adaptive bilateral filter. Experimental results show that the proposed algorithm can efficiently remove ringing artifacts with edge preservation.

Metal Artifact Caused by Magnetic Field Strength and Sequence on T1WI-MRI (자기공명영상에서 자장세기와 시퀀스에 따른 아티팩트 변화)

  • Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.302-308
    • /
    • 2010
  • In MRI, the Ferromagnetic artifact is generated by the metalization within in which the before inspection removal is impossible and the distortion of an image is brought. The distortion measure according to the steel for each sequence of T1 image and magnetic field intensity are analyzed and minimized method is looked into. We used SIEMENS 1.5T and 3.0T MRI for experiment equipment. First, it places within the Phantom making a metalization(Ti+Al, Stainless, Nitinol) on 1.5T, 3.0T MRI and the T1 weighted image for each Sequence is acquired. The distortion of an image and about adjacent portion change of the metal material were compared through the obtained image, we analyzed. In all metalizations, a distortion was generated and a distortion was few in particularly, and Titanium-Aluminium alloy. And the extent of a distortion was worse image in the Turbo spin Echo. The use of the Titanium-Aluminium alloy the inserted in an internal material of the metalization is recommend. and, equipment of 1.5T the patient inserting a metal in an internal is used in an inspection than equipment of 3.0T. Also, the sequence is suitable when it obtains the optimum T1 weighted image of an impersonate to use the Turbo spin Echo.

Image Analysis of Micro Lesions According to Grid Frequency After Removal of Moire Artifact (Moire artifact 제거 후 그리드 주파수에 따른 미세병변의 영상분석)

  • Lee, Sang-Ho;Kim, Gyoo-Hyung;Yang, Oh-Nam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.463-469
    • /
    • 2018
  • Morphological information such as shape and margin of micro lesion is important information for diagnosis of disease in clinical imaging. In this study, we investigated the morphological changes of the micro lesions by comparing the contrast and area in grid suppressed DR images according to grid frequency. In the profile analysis of the image, the mass showed an average intensity variation of 8.6 ~ 72.4 after suppression, The higher the grid frequency, the more the contrast was increased. However, in the images obtained using 103 lp / inch, which is a grid frequency less than the sampling frequency, the contrast of the mass in the vertical direction decreased after suppression. In the binary image, the area change of the mass was also large. As a result, the shape, size, and margin of the mass changed. In the case of very small calcification, the higher the grid frequency is the larger the change in contrast, so that a clear image can be obtained in the post-suppression image. However, we could confirm that the margin of the lesion was blurred and the lesion was lost in some of the images using the 103 lp / inch grid. The higher the frequency of the grid, The change of the contrast of fiber occurred largely and clear boundary was confirmed. The decrease of the number of pixels was small and morphological change was small. In conclusion, when using a grid frequency that is not suitable for the sample frequency, morphological changes or lesion loss of micro lesions in the post- suppression image may give the possibility of misdiagnosis in diagnosis and differentiation of the image.

Cause Analysis and Removal of Boundary Artifacts in Image Deconvolution

  • Lee, Ji-Yeon;Lee, Nam-Yong
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.7
    • /
    • pp.838-848
    • /
    • 2014
  • In this paper, we conducted a cause analysis on boundary artifacts in image deconvolution. Results of the cause analysis show that boundary artifacts are caused not only by a misuse of boundary conditions but also by no use of the normalized backprojection. Results also showed that the correct use of boundary conditions does not necessarily remove boundary artifacts. Based on these observations, we suggest not to use any specific boundary conditions and to use the normalized backprojector for boundary artifact-free image deconvolution.

Wavelet based Image Reconstruction specific to Noisy X-ray Projections (잡음이 있는 X선 프로젝션에 적합한 웨이블렛 기반 영상재구성)

  • Lee, Nam-Yong;Moon, Jong-Ik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.4
    • /
    • pp.169-177
    • /
    • 2006
  • In this paper, we present an efficient image reconstruction method which is suited to remove various noise generated from measurement using X-ray attenuation. To be specific, we present a wavelet method to efficiently remove ring artifacts, which are caused by inevitable mechanical error in X-ray emitters and detectors. and streak artifacts, which are caused by general observation errors and Fourier transform-based reconstruction process. To remove ring artifacts related noise from projections, we suggest to estimate the noise intensity by using the fact that the noise related to ring artifacts has a strong correlation in the angle direction, and remove them by using wavelet shrinkage. We also suggest to use wavelet-vaguelette decomposition for general-purpose noise removal and image reconstruction. Through simulation studies. we show that the proposed method provides a better result in ring artifact removal and image reconstruction over the traditional Fourier transform-based methods.

  • PDF