• 제목/요약/키워드: Illumination measurement

검색결과 234건 처리시간 0.027초

데오도라이트 시스템의 측정 오차 요인에 대한 연구 (A Study on Measurement Error Factors of Theodolite System)

  • 윤용식;이동주
    • 한국공작기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.36-42
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is ${\pm}0.5mm$or better for distance 0~100m. And the system is used for the measurement of a product of middle and large scale. This study is performed for the measurement error factors of the system. We could know that the main measurement error factors are temperature, illumination and skill. Also, we performed the study for the effect according to the height difference of scale bar.

마이크로 레이저 평면빔을 이용한 마이크로채널 내에서의 Micro-LIF 측정 (Micro-LIF Measurement in a Micro-channel Using an Micro Laser Light Sheet)

  • 윤상열;김재민;김수헌;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1540-1545
    • /
    • 2004
  • Measurement of concentration fields in a micro-channel is the crucial technology in the area of Lab-on-a-chip to be used for various bio-chemical applications. It is wel-known that the only possible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been made so far due to the limit of light illumination. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having 5 microns thickness by a micro focus laser line generator. Nile Blue A was used as fluorescent dye for LIF measurement. The laser sheet beam illuminates an exact plane of concentration measurement in the micro-channel to increase the signal to noise ratio and reduce the depth uncertainty considerably.

  • PDF

데오도라이트 시스템의 측정 불확도 연구 (A Study on Measurement Uncertainty of Theodolite System)

  • 이건탁;이동주;박흥철;오재명
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.229-233
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is 0.5 mm or better for distance 0 ~ 100m. And the system is used for a product of middle and large scale. This study is performed for the measurement uncertainty of the system. We could know that the main uncertainty factors are temperature, illumination and skill. And, we perform the study for the effect according to the height difference of scale bar. And, we calculated the measurement uncertainty with those factors.

  • PDF

보광용 LED의 광특성과 광자속밀도 특성 (A Study on the Lighting and the Photosynthetic Photon Flux Density with LED for Light Reinforcement)

  • 이붕주
    • 한국산학기술학회논문지
    • /
    • 제22권3호
    • /
    • pp.333-338
    • /
    • 2021
  • 본 연구에서는 식물생장에 필요한 빛의 파장과 세기, 광합성 광자속밀도에 대한 정확한 이해를 위해 LED의 광변화를 통해 단색광과 혼합광에 조건변화에 따른 광합성 광량자자속밀도와 조도특성 파악하였다. LED의 조도와 광합성 광자속밀도의 특성을 파악하여 LED 조명설계시 도움을 주고자 한다. 조도와 광합성 광자속밀도는 거리에 반비례하는 특성을 보이며, 조도의 특성을 기준할 때는 Green광이 중요하며, 광합성을 위한 광합성 광자속밀도는 Blue광이 중요함을 알게 되었다. 식물의 광합성 특성만을 고려할 때, 영향도는 Blue > Red > white > Green 순서로 나타내었으며, 측정거리 30[cm]을 기준으로 60[cm], 90[cm], 120[cm]의 감소수준은 각각 약 36[%], 18[%], 10[%]의 수준으로 감소됨을 알았다. Red:Blue광원의 혼합광원의 특성을 본 결과, 혼합 Red;Blue) LED 광원 비율(2:1, 3:1, 4:1)과 측정거리에 따른 값은 30[cm]에서의 측정값을 100%라 가정할 때 120[cm]에서의 측정값은 10~11[%]수준임을 확인하였다. 얻어진 결과를 통해 실내 온실의 광효율 극대화를 위한 최적 구조를 제안하고 향후 연구의 진행 방향 설정에 기여하고자 하였다.

내장형 분광광도시스템 구성에 따른 조명 영향 평가 (Evaluation of illumination effect for on-board spectrometer system)

  • 이상식;이충호
    • 한국정보전자통신기술학회논문지
    • /
    • 제3권2호
    • /
    • pp.18-24
    • /
    • 2010
  • 본 연구에서는 표준 색차계와의 비교와 색상정보 좌표계 분석법을 이용하여, 비접촉 및 비파괴 측정 장치로 많은 분야에서 사용하고 있는 내장형 분광광도계의 조명 영향을 평가하였다. 본 연구에서 사용한 색상지는 표준 반사물질과 만셀 표준 색상인 빨강, 노랑, 초록, 파랑 색상지를 사용하였다. 표준 색차계 시스템 및 내장형 분광광도계 시스템을 비교 분석하기 위하여, 실험 재료 색상지를 색상지별 20번 측정하였다. 본 연구에서는 비접촉 및 비파괴 검사 장치에 내장형 분광광도계 응용에서 조명을 일정하게 공급하고 캘리브레이션을 정확하게 수행한다면, 조명의 영향을 거의 받지 않는 시스템을 구성할 수가 있을 것으로 판단되었다.

  • PDF

The metameric effect of monolithic zirconias with varying yttrium ratios

  • Mehmet Ejder Guven;Ozlem Kara
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권1호
    • /
    • pp.48-56
    • /
    • 2024
  • PURPOSE. To evaluate the metameric disparities among monolithic zirconia materials with differing yttrium compositions across various lighting conditions. MATERIALS AND METHODS. Thirty-six square-shaped zirconia samples measuring 10 × 10 × 0.5 mm were prepared from monolithic zirconia materials with three different yttrium contents. A 0.2 mm thick layer of polymerized dual-polymerizable self-adhesive resin cement was created using a silicone mold with the same dimensions as the prepared zirconia specimens. To evaluate metamerism, color measurements were conducted using a spectrophotometer device on a neutral gray background in a color measurement cabinet that offers four different illumination environments. All samples underwent aging by subjecting them to 10000 thermal cycles using a thermal cycle tester. Following thermal aging, color measurements were taken once more, and the data were recorded using the CIE L*, a*, b* color system. Two-way ANOVA and Post-hoc Bonferroni tests were employed to analyze the data. RESULTS. It was observed that there was no statistical difference among the color measurements made in different illumination environments of the monolithic zirconia ceramics used to evaluate metamerism (P > .05). This observation remained consistent both before and after thermal aging. After thermal aging, the color of monolithic zirconia materials exhibited a tendency towards red and yellow hues, accompanied by a decrease in brightness levels. CONCLUSION. It can be stated that different illumination conditions did not affect the metamerism of monolithic zirconia materials, but there was a color change in monolithic zirconia materials after a thermal aging period equivalent to one year.

고출력 LED의 접합온도 측정회로 설계 및 구현 (Design and Implementation of High Power LED Junction Temperature Measurement Circuit)

  • 박종연;유진완
    • 산업기술연구
    • /
    • 제30권A호
    • /
    • pp.83-88
    • /
    • 2010
  • Recently, the LED lighting is widely used to illumination purpose due to its high luminous efficiency and the long life time. However, the light power and lifetime is reduced by junction temperature increment of LED. So it is important to measure the junction temperature accurately. In this paper, we proposed a new design and implementation method of high power LED junction temperature measurement circuit. The proposed circuit has two current sources which are a driving current source and a measurement is verified by experiment, and the result shows that the proposed circuit is appropriate to practical use.

  • PDF

공작기계 상에서 마이크로드릴 공정의 머신비전 검사시스템 (Machine Vision Inspection System of Micro-Drilling Processes On the Machine Tool)

  • 윤혁상;정성종
    • 대한기계학회논문집A
    • /
    • 제28권6호
    • /
    • pp.867-875
    • /
    • 2004
  • In order to inspect burr geometry and hole quality in micro-drilling processes, a cost-effective method using an image processing and shape from focus (SFF) methods on the machine tool is proposed. A CCD camera with a zoom lens and a novel illumination unit is used in this paper. Since the on-machine vision unit is incorporated with the CNC function of the machine tool, direct measurement and condition monitoring of micro-drilling processes are conducted between drilling processes on the machine tool. Stainless steel and hardened tool steel are used as specimens, as well as twist drills made of carbide are used in experiments. Validity of the developed system is confirmed through experiments.

구조물의 진동 해석을 위한 비접촉 레이저 계측 시스템 개발 (Development Non-contact Laser Measuring System for Vibration Analysis of Structures)

  • 정현철;김경석;최정석;김성식;강기수;정승택;최태호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.911-914
    • /
    • 2003
  • The non-contact laser measurement system what can be used for the vibration analysis of structures is discussed. There are few systems using laser speckle interferometer for vibration analysis. One of these systems is the Electronic Speckle Pattern Interferometer (ESPI). With ESPI system, one can obtain the vibration mode shape qualitatively and the maximum vibration amplitude quantitatively of the structure at each resonance frequency. In this paper, the phase-shifting ESPI system with stroboscopic illumination for measuring vibration mode shapes is constructed and the operating software is programmed. The results are compared with that of commercial ESPI system.

  • PDF

Gabor wavelet과 신경망의 영역별 적용을 통한 얼굴 인식 (Face Recognition using Regional Gabor Wavelet and Neural Networks)

  • 최용준;이상현;정종률;최병욱
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.2020-2023
    • /
    • 2003
  • In this paper, our proposed system uses the regional Gabor wavelet and Neural Network to implement face recognition similar to human face recognition system, because the Gator wavelet expresses visual recognition system of human mathematically and the regional Neural Network is robust to white noise and partial illumination. This system consists of two stages of building database and recognizing face. One is composed by using the supervised learning of Neural Network. At this time, the Neural Network is applied to the upper and the lower part of face images respectively. The Backpropagation algorithm is used to learn Neural Network. Another consists of calibration of slope of face image, measurement of illumination variant using deviation with average face image and similarity comparison using Euclidean distance measure.

  • PDF