• Title/Summary/Keyword: Illumination efficiency

Search Result 349, Processing Time 0.029 seconds

Design and Analysis of Diffractive Grating Imprinted Light-guide Plate for LCD Illumination

  • Choi, Hwan-Young;Park, Young-Pil
    • Journal of Information Display
    • /
    • v.5 no.1
    • /
    • pp.7-15
    • /
    • 2004
  • A highly simplified backlight unit mainly composed of diffractive grating in sub-micron order imprinted light-guide plate (LGP) is proposed for edge-lit backlight unit. Optical characteristics of the imprinted LGP are examined by RCWA and the performance is verified through Monte Carlo simulation. Results show that the diffraction efficiency, luminous flux and its uniformity over the area are significantly affected by the angle of incident ray. Consequently couples of design considerations are additionally proposed to enhance luminous flux. In terms of peak luminance and out-coupling luminous flux, the experimental results are agreed well with the performance simulation. Finally, compared with optical characteristics of conventional backlight unit, we could conclude that the proposed simplified backlight unit made of diffractive grating imprinted light-guide plate is a good substitute for the conventional backlight unit.

Characteristics of Polymer Solar Cells Depending on the Thickness of Active Layer

  • Lee, Dong-Gu;Noh, Seung-Uk;Suman, C.K.;Kim, Jun-Young;Lee, Seong-Hoon;Lee, Chang-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1204-1207
    • /
    • 2009
  • We investigated the device performance of bulk heterojunction solar cells depending on the active layer thickness. For the systematic comparison, the polymer solar cells comprising RR-P3HT:PCBM (1:0.8 (wt%:wt%)) blend films with different thickness were characterized by impedance spectroscopy, and J-V measurement in dark and solar simulated illumination. The device with 120 nm thickness of active layer exhibited maximum power conversion efficiency of 3.5 % under AM 1.5 100mW/$cm^2$ illumination condition.

  • PDF

The Development of Average illumination Calculation Software (ZCM에 의한 평균조도 계산용 Software개발)

  • Yun, Mee-Rim;Sim, Sang-Man;Hur, Nam-Don;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.1-9
    • /
    • 2001
  • At the beginning of the lighting design, the improvement of lighting design method and standardization of the lighting design needed for saving lighting energy in the building design that can help to choose a high efficiency luminaire and it can calculate LLF(light loss factor). for that reason Average Illumination Calculation Software using ZCM for lighting designer was developed.

  • PDF

JND based Illumination and Color Restoration Using Edge-preserving Filter (JND와 경계 보호 평탄화 필터를 이용한 휘도 및 색상 복원)

  • Han, Hee-Chul;Sohn, Kwan-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.6
    • /
    • pp.132-145
    • /
    • 2009
  • We present the framework for JND based Illumination and Color Restoration Using Edge-preserving filter for restoring distorted images taken under the arbitrary lighting conditions. The proposed method is effective for appropriate illumination compensation, vivid color restoration, artifacts suppression, automatic parameter estimation, and low computation cost for HW implementation. We show the efficiency of the mean shift filter and sigma filter for illumination compensation with small spread parameter while considering the processing time and removing the artifacts such as HALO and noise amplification. The suggested CRF (color restoration filter) can restore the natural color and correct color distortion artifact more perceptually compared with current solutions. For the automatic processing, the image statistics analysis finds suitable parameter using JND and all constants are pre-defined. We also introduce the ROI-based parameter estimation dealing with small shadow area against spacious well-exposed background in an image for the touch-screen camera. The object evaluation is performed by CMC, CIEde2000, PSNR, SSIM, and 3D CIELAB gamut with state-of-the-art research and existing commercial solutions.

Design of Illumination Control System Using Microwave Sensors and Dimming Control (마이크로웨이브센서와 디밍제어를 활용한 조명제어시스템 설계 및 구현)

  • Song, Eun-Seong;Min, Byoung-Won;Oh, Yong-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.19-26
    • /
    • 2013
  • In this paper, we present a novel illumination system for parking lots constructed underground. We design and implement this system using microwave sensors and dimming control of LED fluorescent lamps so that we can obtain lighting efficiency of the illumination scheme. We construct an effective illumination system in the aspects of performance and cost, resulting in energy-saving and electricity reduction. Recently conventional energy-saving method applied to old underground parking lots mainly relies upon turning off the half of total number of lamps installed in the parking lot. Sometimes there are some lots that have infrared sensor to be used to turn on/off the fluorescent lamps to realize these operations smoothing. The other schemes utilize timer to control lighting time of the fluorescent lamps. These conventional schemes are forcing to turn off a part of lamps installed so that we cannot apply them in a systematic way. Moreover they will be most inefficient when we leave them alone to be continuous consumers. The lighting control system proposed in this paper can recognize objects through microwave sensors and inform the appropriate lighting time, furthermore we can adjust brightness of LED lamps following the surroundings using dimming control scheme so that we can epochally improve the illumination system for underground parking lots. According to our sophisticated test experiments, we can maximally obtain 81.9% of energy-saving effectiveness using the system proposed in this paper.

Effects of reversible metastable defect induced by illumination on Cu(In,Ga)Se2 solar cell with CBD-ZnS buffer layer

  • Lee, Woo-Jung;Yu, Hye-Jung;Cho, Dae-Hyung;Wi, Jae-Hyung;Han, Won-Seok;Yoo, Jisu;Yi, Yeonjin;Song, Jung-Hoon;Chung, Yong-Duck
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.431-431
    • /
    • 2016
  • Typical Cu(In,Ga)Se2 (CIGS)-based solar cells have a buffer layer between CIGS absorber layer and transparent ZnO front electrode, which plays an important role in improving the cell performance. Among various buffer materials, chemical bath deposition (CBD)-ZnS is being steadily studied to alternative to conventional CdS and the efficiency of CBD-ZnS/CIGS solar cell shows the comparable values with that of CdS/CIGS solar cell. The intriguing thing is that reversible changes occur after exposure to illumination due to the metastable defect states in completed ZnS/CIGS solar cell, which induces an improvement of solar cell performance. Thus, it implies that the understanding of metastable defects in CBD-ZnS/CIGS solar cell is important issue. In this study, we fabricate the ITO/i-ZnO/CBD-ZnS/CIGS/Mo/SLG solar cells by controlling the NH4OH mole concentration (from 2 M to 3.5 M) of CBD-ZnS buffer layer and observe their conversion efficiency with and without light soaking for 1 hr. From the results, NH4OH mole concentration and light exposure can significantly affect the CBD-ZnS/CIGS solar cell performance. In order to investigate that which layer can contain metastable defect states to influence on solar cell performance, impedance spectroscopy and capacitance profiling technique with exposure to illumination have been applied to CBD-ZnS/CIGS solar cell. These techniques give a very useful information on the density of states within the bandgap of CIGS, free carriers density, and light-induced metastable effects. Here, we present the rearranged charge distribution after exposure to illumination and suggest the origin of the metastable defect states in CBD-ZnS/CIGS solar cell.

  • PDF

A Study of Fabrication of RF Control System for Building Sunshade (건물 차양을 위한 RF제어 시스템 제작에 관한 연구)

  • Park, Jung-Cheul;Chu, Soon-Nam
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.149-157
    • /
    • 2014
  • This paper is based on the fabrication of wireless control system for the building shading device. RF Module was controlled by UHF wireless CC1020 chip which has low electrical power and low electrical voltage. Also 447.8625~447.9875 frequency, 4800Baud data rate and 12.5 kHz channel spacing was controlled by the use of SPDT switch and with Microcontroller program. Furthermore, the helical antenna was used. The starting production of 447.8625~447.9875 kHz wireless electrical power was used. As the result, it did not exceed 10dBm which is the standard of low power wireless system. Shading efficiency was measured at 25%, 50%, 75% direction with controlling the interior temperature and the intensity of illumination at the rate of 1 hour. As the result, the intensity of illumination was lowered to 82~87% at 25% direction with $0.6{\sim}1.4^{\circ}C$ lowered temperature. At 50% direction, the intensity of illumination was lowered to 60~68% with $2.3{\sim}4.1^{\circ}C$ lowered temperature. And at 75% direction, the intensity of illumination was lowered to 41~47% with $3.4{\sim}5.1^{\circ}C$ lowered temperature.

Photosynthetic Characteristics of Sedum takevimense on Various Moisture Conditions in a Green Roof System (옥상녹화시스템에서 수분 조건에 따른 섬기린초의 광합성 특성)

  • Li, Hong;Kang, Tai-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.140-146
    • /
    • 2013
  • This experiment was conducted in order to study the physiological characteristics of Sedum takevimense in different moisture conditions. The photosynthetic rate, water use efficiency and the respiratory rate were determined by using a photable photosynthesis system. According to the results, the best illumination range and moisture range were explicitly selected. The highest photosynthetic rate was at $600{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and after this value, the trend showed a reduction. When the moisture was 11.31%, the photosynthetic capacity and water use efficiency reached maximum value, but the respiratory rate reached maximum value at 7.91%. According to the measured values, the best illumination range was $600{\sim}1,200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and the best moisture range was 7.09~11.31%.

Evaluation Study of a Double Blind Light Pipe Daylighting System Efficiency and an Illumination Energy Reduction (이중 블라인드 광파이프 주광 조명시스템 효율 및 조명에너지 절감량 평가 연구)

  • Kang, Eun-Chul;Yoo, Seong-Yeon;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.89-95
    • /
    • 2013
  • A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide ${\times}$ 2.4 m height ${\times}$ 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.

LED color control using Arduino and Human motion sensors (아두이노와 인체감지 센서를 이용한 LED 컬러 제어)

  • Kim, Sang Ki;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.69-73
    • /
    • 2014
  • Recent interest in the worldwide energy to increase, and energy savings of the energy for effective operation of the IT technology there is a demand. By using a low-power LED energy efficient energy use worldwide for a variety of studies have been conducted. In Korea, 20-30% of the domestic electricity consumption corresponding to the illumination in order to conserve energy used by various sensors associated with illumination control studies are underway. That is the next generation of energy began to pay attention to the LED light source, LED and Arduino In this paper, an ultrasonic sensor to control and want to maximize the energy efficiency of the management. Paper, the user is directly operating the separate controller that controls the LED light, instead of being recognized through human body detection LED light on / off to control the experiment and study verified. In this paper, we develop an interface that also allows them to maximize the efficiency of energy management and efficiency, accompanied by expansion of commercialization can be achieved.