• Title/Summary/Keyword: Illuminance Ratio

Search Result 76, Processing Time 0.025 seconds

Effect of LED Irradiation on Growth Characteristids of Ginseng Cultivated in Plastic Film House

  • Seo, Sang Young;Cho, Jong hyeon;Kim, Chang Su;Kim, Hyo Jin;Kim, Dong Won;An, Min Sil;Yoon, Du Hyeon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.10a
    • /
    • pp.45-45
    • /
    • 2019
  • This experiment was carried out using artificial clay and LED in the plastic film house (irradiation time: 08:00~18:00/day). Seedlings (n = 63 per $3.3m^2$) of ginseng was planted on May 17, 2018. LED was combined with red and blue light in a 3:1 ratio and irradiated with different light intensity. The average air temperature from April to September was $12.3^{\circ}C$ $-26.0^{\circ}C$ and it was the the highest at $26.0^{\circ}C$ in August. The test area where fluorescent lamp was irradiated tended to be somewhat higher than the LED irradiation area. The chemical properties of the test soil are as follows. pH levels was 5.3~5.5, EC levels 0.45~0.52 dS/m and OM levels 33~37%. The total nitrogen content was 0.35~0.47% and the available $P_2O_5$ contents was 13.7~16.0 mg/kg, which was lower than the suitable level of 70~200 mg/kg. Exchangeable cations K and Mg contents were within acceptable ranges, but the Ca contents was $28{\sim}38cmol^+/kg$ levels higher than the permissible level ($2{\sim}6cmol^+/kg$). Germination of ginseng leaves took 8~9 days and the overall germination rate was 70~75%. The photometric characteristics of LED light intensity are as follows. The greater the light intensity, the higher the PAR (Photosynthetic Action Radiation) value, illuminance and solar irradiation. Photosynthetic rate was also increased with higher light intensity was investigated at $1.7{\sim}3.2{\mu}mol\;CO_2/m^2/s$. Leaf temperature ($23.7{\sim}24.8^{\circ}C$) by light intensity was the same trend. The growth of aerial parts (plant height etc.) were generally excellent when irradiated with 3 times the light intensity, the growth of the ginseng aerial parts were excellent as follows. The plant height was 42.6 cm, stem length was 25.2 cm, leaf length was 9.6 cm and stem diameter was 5.0 mm. The growth of underground part (root length etc.) was the same, and the root length was 24.4 cm, the tap root length was 6.0 cm, diameter of taproot was 18.2 mm and the fresh root weight was 17.2 g. There were no disease incidence such as Alternaria blight, Gray mold and Anthracnose. Disease of Damping off occurred 2.2~3.6% and incidence ratio of rusty root ginseng was 14.6~20.7%. Leaf discoloration rate was 13.7~48.9% and increased with increasing light intensity. Ginsenoside content of ginseng by light intensity is under analysis.

  • PDF

Actual Conditions on the Illumination Environment of the Elderly House (고령자주택의 조명환경 실태조사)

  • An, Ok-Hee;Choi, Mi-Hyang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • This research surveys actual conditions in order to examine the lighting environments of the elderly's residential 50 households. The results is as following. First, The elderly indicated that they felt the living room and the kitchen are usual degree, dark only in bedrooms and rest rooms of brightness. And about satisfactory degree of residential illumination is being above of usual Satisfaction. Second, Problems of lighting environments of elderly's houses were brightness and management, when lighting environmental reconstruct, considered brightness and equipment superannuation, and they want the focus on brightness in the reconstruction. Third. Operating method of lighting was used almost overall lighting in bedroom and bathroom, overall lighting and part lighting are used together in kitchens. The living room has a lot of cases which uses only a general illumination, but the cases which overall lighting and part lighting are used together has occupied 40[%]. Fourth, An average Illuminance of the bedroom is 104.17[lx], an average unifonnity ratio is 60.22[%]. The livingroom's average is 116.15[lx], 51.48[%]. The sink's average is 236.40[lx], the table average is 160.73[lx] in the kitchen. The washstand's average is 109.81[lx], the chamber's average pot is 74.33[lx] in the bathroom. These results are generally darker than the standard.

Development of detachable air-cap module for improving the performance of windows (창호 성능 개선을 위한 에어캡 탈부착형 모듈 개발)

  • Seo, Beomdong;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.63-68
    • /
    • 2017
  • Purpose: Various studies to solve the problem of increased energy consumption in the buildings are being carried out recently. Especially, the economic feasibility and insulation performance of the air-cap have been verified so that various studies regarding the reduction of building energy consumption have been carried out. However, previous studies regarding the air-cap were only carried out based on the verification of its insulation performance according to the size and attachment position of the air-cap. Therefore, the purpose of this study is to suggest a detachable air-cap module for improving the performance of the windows, evaluate the performance based on cooling, heating and light environments and verify its effectiveness through a real-scale testbed. Method: In this study, the energy saving performance in the circumstance where there is no attachment of an air-cap (Case 1), the circumstance where there is the attachment of air-cap on the glass surface of window (Case 2) and the circumstance where there is the attachment of an air-cap on the window frame (Case 3) were compared in order to verify the performance of the detachable air-cap module (Case 4), and the electricity consumption of cooling, heating and lighting equipment to maintain the appropriate indoor temperature and Illuminance for each case was calculated and utilized as indicators for the performance evaluation. Result: The result of this study is as follows. 1) In this study, the detachable air-cap module which was easily detachable through the principle of the magnet was suggested. 2) When Case 4 is applied, the electricity consumption of cooling and heating equipment can be reduced by 27.5%, 13.2% and 3.4% in comparison with Case 1, Case 2 and Case 3 respectively. 3) When the air-cap is applied to the window, the lighting energy consumption increases by 4 % in comparison to the non application of the air-cap, and this factor or aspect should be considered when applying the air-cap. 4) According to the performance evaluation result in consideration of cooling, heating and light environments, Case 4 demonstrates an energy saving ratio of 22.6%, 10.6% and 2.7% in comparison to Case 1, Case 2 and Case 3 respectively, indicating that it is effective for improving the performance of windows.

A Design and Performance Evaluation of Differentiated Daylight-Glazing Systems (가변 투과시스템의 광제어 특성을 고려한 통합 채광시스템의 적용성 평가에 관한 연구)

  • Kim, Gon;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.13-22
    • /
    • 2005
  • This research aimed to generate two points of daylighting application as follows: 1) providing daylight performance data with a variety of glazing materials for a large window and 2) designing and evaluating an experimental type of differentiated window. For this purpose, we compared the daylight and distribution performance of new defined type of window configuration to the conventional window counterpart with a variety of glazing materials. The comparison was made for a deep, south-facing perimeter zone with large window, without any interior obstruction. The conventional window is the base single homogeneous glass pane, where as the differentiated window uses of two different glazings; an upper daylight glazing with high visible transmission and lower view window with lower transmittal glass. The daylight performance data was translated into a ratio between outdoor illuminance and the interiors. The simulated analysis of the conventional window indicates that the interior light levels have been changed proportionally dependent on the transmittance of the applied glass. The comparison of daylight distribution analysis showed that the differentiated window has lots of photometric advantage by the optical function of upper daylight window. In particular, the contribution of higher daylight window into deep rear space must be stressed for daylighting application.

Effect of Photoperiod Considering Animal Welfare for Growth Ability and Blood Properties in Broiler Chicks (동물복지를 고려한 점등시간이 육계 병아리의 성장 능력 및 혈액 성상에 미치는 영향)

  • Kim, Hee-Jin;Son, Jiseon;Jeon, Jin-Joo;Kim, Hyun-Soo;Kang, Hwan-Ku;Lee, Woo-Do;Yun, Yeon-Seo;Hong, Eui-Chul
    • Korean Journal of Poultry Science
    • /
    • v.49 no.3
    • /
    • pp.139-144
    • /
    • 2022
  • This study was conducted to investigate the effect of three different photoperiods on growth performance, blood properties, and stress indicators in broiler chicks between 1-7 days after hatching. Two hundred and fifty-two 1-day-old male broiler chicks (57.0±0.12 g) were divided into three treatments, with 4 replicates per treatment and 22 birds per replicate subjected to three different photoperiods of 24L, 22L/2D and 18L/6D. A light-emitting diode bulb served as the light source, with an illuminance of 30 lx. As an experimental diet, a commercial feed based on a corn-soybean meal, with 22% CP and 3,150 kcal/kg ME diet, and water were fed ad libitum. Body weight gain, feed conversion ratio, and liver weight ratio showed a statistically significant difference between the 18L/6D and 24L treatments (P<0.05), but with no significant difference between the 22L/2D treatment and either the 24L or 18L/6D treatment. The breast meat ratio was 5.59% in the 18L/6D treatment group, which was lower than that of other treatment groups (P<0.05). The triglyceride levels were highest (P<0.05) in the 18L/6D treatment among treatments, but alanine aminotransferase levels were significantly higher (P<0.05) in the 22L/2D treatment than in the 24L treatment. Levels of cytokines, i.e., Interleukin-6 and Tumor Necrosis Factor-α did not show a significant difference among the treatments, but corticosterone content was significantly higher (P<0.05) in the 24L treatment than in the 18L/6D treatment. In conclusion, 22 hours of lighting is appropriate between 1~7 days after hatching, considering growth performance and the overall health of broiler chicks.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF