• Title/Summary/Keyword: Illuminance Ratio

Search Result 76, Processing Time 0.023 seconds

실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석 (Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model)

  • 백승헌;김정태
    • KIEAE Journal
    • /
    • 제6권4호
    • /
    • pp.25-32
    • /
    • 2006
  • Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

해안 휴양지의 야간경관 개선을 위한 건축물의 조명환경 연구 - 경포도립공원을 중심으로 - (A Study on the Luminous Environments of Architectural Building for Improvement of Night-Scape in Coastal Resort - Focused on the Gyengpo Park -)

  • 조원석;김흥기
    • 한국농촌건축학회논문집
    • /
    • 제10권3호
    • /
    • pp.27-34
    • /
    • 2008
  • Recently, the outdoor lighting of architectural Facade has increased for the improvement of night-scape in urban and coastal resort. The purpose of this research is to analyze lighting characteristics; Luminance, Illuminance, Color Temperature, Chromaticity in Gyengpo Park of Eastern famous coastal resort. The result of this paper is as follows: 1) The Luminance ratio was measured that compare to the 1:10 criterion(IESNA) was in excess to the most building except "K". Because of these condition, Luminance environments was injurious to visual health the overuse of the outdoor lighting or glare to the eyes. 2) The level of vertical Illuminance value was insufficient 33.3% among the cases of survey with 4Lux standard of CIE. 3) The kinds of outdoor lighting of BLDG were increased lighting emitting diode(LED), metal halide(MH) instead of reduction trend of neon, fluorescent light, halogen. As the crisis of Energy resources we will be investigate adapt method of outdoor lighting, which design is based on economical efficiency by the use of optimum lighting.

  • PDF

광선추적기법을 활용한 곡면형 광선반시스템 설계 및 채광성능 평가 (Evaluation of Daylighting Performance and Design of a Curved-Lightshelf by the Ray Tracing Method)

  • 김동수;윤종호;신우철;이광호
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.136-141
    • /
    • 2011
  • The lightshelf system reduces intense illumination levels of indoor from direct sun light and reflect to lead diffused light into indoor deeply. This study aims to design acurved-lightshelf by a ray tracing method and evaluate the daylighting performance of window integrated with the curved-lightshelf by computer simulations. For this purpose, evaluation test model was designed for the experiments to validate the simulation model, and the curved-lightshelf was designed by the ray tracing method using Ecotect. After the office model was designed using 3D simulation, the average indoor illuminance, luminance and distribution of illuminance were evaluated by simulation which has a algorithm of Radiosity and Ray-Tracing method under four different cases(case1;no lightshelf, case2; Flat board, case3; tilted at $30^{\circ}$ angle, case4; the curved-lightshelf). As results, it turns out that case1 showed higher average illuminance and case4 was more uniformly distributed than case2 and case3, In addition average luminance of case1 was also lower. indicating that the curved-lightshelf would reduce the possibility of the glare, while maintaining the sufficient daylight level.

아파트의 지하주차장의 조명 운영개선 (Improvement of Underground Parking Garages Lighting in Residential Areas)

  • 장수정;최안섭;최성열
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.163-168
    • /
    • 2004
  • The improvement of perspectives on dark and limited underground space could be an important factor in successful underground space development. Current trend in the apartment underground parking lot requires not only quantitatively energy efficient design and operation, but also qualitative improvement of the space. For this, we need to consider two factors: Firstly, to understand the characteristics of the fluorescent lamp. Secondly, to improve the uniformity ratio of illuminance. In winter season, a way to keep the uniformity and a method not to lower the indoor illuminance level by cold ambient air. Therefore, a change in interval and arrangement of the lighting fixtures is required. Also, in their operation, current time-fixed control method needs to be changed into the control that method considers the use pattern.

  • PDF

학교 건물에서 외부 차양 장치 유형에 따른 일반교실 내 빛환경 특성에 관한 연구 (A Study on the Characteristics of Daylighting Environment in Classroom of an School Building Due to the External Shading Devices)

  • 임재한;정진주;이지영
    • 교육시설
    • /
    • 제15권2호
    • /
    • pp.4-15
    • /
    • 2008
  • The purpose of this study was to evaluate the characteristics of daylighting environment in classroom of an school building due to the external shading devices such as fixed louvers, light shelves and exterior venetian blinds. In this study, we have made a field research with regard to the facade design in classroom of an school building. And we have made a classification of external shading devices considering the design parameters. Finally, through RADIANCE simulation, we have calculated the spatial distribution of illuminance, uniformity ratio of illuminance and daylight factors. The results of this study will provide the building designer with the basic daylighting performance data at early design stages.

실내조명용 화이버 광학 집광기의 성능에 관한 실험적 평가 (Experimental Evaluation of a Fiber Optic Concentrator for Daylighting)

  • 한현주;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제28권3호
    • /
    • pp.27-34
    • /
    • 2008
  • A series of outdoor tests were conducted on a fiber optic solar concentrator system for its performance on daylighting. The system is comprised of four main components - a parabolic dish reflector, a convex mirror, a homogenizer tube and an optical fiber cable. Results show that the system could be successfully applied for indoor lighting if some improvements are made for light transmiting (optical) cables. A maximum concentration ratio of 90 was observed delivering the illuminance of 4,800 lux at a distance of 1.2m from the diffuser for the outdoor illuminance of 102,100 lux.

50W급 LED 보안등용 조명광학계 개발 (Development of Optical System for 50W LED Security Lamp)

  • 정병조;장성환;노용기
    • 한국산학기술학회논문지
    • /
    • 제13권1호
    • /
    • pp.296-305
    • /
    • 2012
  • 본 연구에서는 기존 LED 보안등의 LED 광원 직진성에 의한 눈부심 현상을 개선하고, 조도 균제도를 높게 유지하며, 회전 대칭이 아닌 편축으로 긴 배광 분포를 가지도록 하여 LED 보안등 간에 생기는 광 공핍현상을 해결할 수 있는 보안등용 LED 2차 렌즈를 개발하였다. 개발 광학계는 보안등용 조명 기준에 만족하도록 설계하였으며, 렌즈의 형태는 단일 렌즈로 조명 설계 및 해석 프로그램을 이용한 설계와 분석을 통해 최적화를 하였다. Mock-up을 제작하여 실제 측정을 통해 조도 측정 데이터와 조도 균제도 데이터를 확보하였다.

제주시 도로조명 실태조사 및 모델링 (Modeling and Actual Investigation of Roadway Lighting in Jejusi)

  • 오성보;김일환;이상근
    • 조명전기설비학회논문지
    • /
    • 제20권7호
    • /
    • pp.1-5
    • /
    • 2006
  • 도로조명은 차량 운전자와 보행자에게 장애물을 신속 정확히 그리고 편안하게 볼 수 있는 도로의 야간 주위환경을 제공한다. 또한 밤에 도로설비 이용을 원활하게 함은 물론 교통의 흐름을 향상시켜 교통안전을 증진시키는데 목적을 두고 있다. 이 논문은 제주시내 중심가 8개 도로의 등기구 설치현황을 실측조사 하였으며 조명기구 배열방식을 고려하여 4개 도로의 조도 실측을 통하여 수평면조도와 균제도를 기준치와 비교분석하였다. 이를 토대로 제주시 주요 도심지 상가 도로에 관한 시뮬레이션으로 도로조명의 적합한 모델을 제시하였다.

축소모형을 이용한 분할형 유리 투과체 창호시스템의 채광성능실험 (Scale Model Experiment on Daylighting of Differentiated Glazing System)

  • 정인영;김정태
    • KIEAE Journal
    • /
    • 제4권4호
    • /
    • pp.61-68
    • /
    • 2004
  • Daylight is a critical factor in architecture, as it helps enhance the working efficiency and pleasantness of the people working inside, in addition to reduce the power consumption in heating and cooling and make the interior space brighter. There are many kinds of glazing and daylighting systems. At present, research and efforts for their development are carried out, alongside quantitative evaluation. This study aims to present basic materials to be used to design proper glazing and daylighting systems in architecture based on a quantitative evaluation by scale models of existing office buildings. The result of the study can be summarized as follows. 1)As a result of the experiment, it appeared that the ratio of the interior illumination (i.e. at the working table, ceiling and wall) against the outdoor illumination increases at a constant rate, as the transmittance of the glazing goes up. 2) It was found that the SIR(Sunlight Illuminance Ratio) of a separated window system goes up by 20-50% at the rear part than in the case of an ordinary window system.

에너지 저감과 업무 효율성을 위한 LED 조명환경 평가에 대한 연구 (A Study on Evaluation of LED Lighting Environments for Energy Saving and Work Effectiveness)

  • 김형선;임재현;이기선;김길희;정희창;김진호
    • 감성과학
    • /
    • 제18권2호
    • /
    • pp.45-54
    • /
    • 2015
  • 본 연구에서는 LED 광원에 대하여 재실자의 업무 효율성과 에너지 저감 효과를 알아보기 위한 실험을 실시하였다. 이를 위해 LED 광원의 특성인 펄 스 폭변조(PWM, pulse width modulation)와 조도(lux)를 제어하여 총 9가지의 다양한 조명환경을 구성하였다. LED 조명의 펄스변조 비율은 각각 R:G:B=1:1:1, R:G:B=4:1:5, R:G:B=8:7:7으로 하였으며, 조도는 각각 400 lx, 700 lx, 1000 lx 으로 설정하였다. 또한, 실내환경은 온도 $20{\sim}24^{\circ}C$, 습도 50~60%, 착의량 1 clo 로 설정하였다. 각각의 주어진 9개의 조명환경에서 업무 효율성과 에너지 소비에 대해 분석하였다. 업무 효율성 분석을 위해 오류검색수정 작업을 실시하였으며, 에너지 소비 분석을 위해 각 조명환경에서 누적 소비전력을 측정하였다. 제안한 조명환경을 통해 실험한 결과, 업무 효율성은 400 lx 보다 700 lx 이상에서 정확도 및 소요시간의 효율이 좋았으며, 소요시간의 경우 제안한 펄스변조 R:G:B=8:7:7 에서 가장 좋은 효율을 나타냈다. 또한, 각각의 조도에 대한 소비전력은 펄스변조 R:G:B=8:7:7 > RGB=1:1:1 > R:G:B=4:1:5의 순으로 낮게 나타났다. 따라서, 본 논문에서 제안한 펄스 폭 변조 효과가 업무효율성 및 에너지 저감에 영향을 미치는 것을 확인할 수 있었다.